Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2007; 50:877-883, doi:10.1016/j.jacc.2007.04.081 (Published online 10 August 2007).
© 2007 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2007.04.081v1
50/9/877    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, K. L.
Right arrow Articles by Hood, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lee, K. L.
Right arrow Articles by Hood, M.

CLINICAL RESEARCH

First Human Demonstration of Cardiac Stimulation With Transcutaneous Ultrasound Energy Delivery

Implications for Wireless Pacing With Implantable Devices

Kathy L. Lee, MBBS, FACC*,*, Chu-Pak Lau, MD, FACC*, Hung-Fat Tse, MD, FACC*, Debra S. Echt, MD, FACC{dagger}, David Heaven, MBChB{ddagger}, Warren Smith, MBChB{ddagger} and Margaret Hood, MBChB{ddagger}

* Cardiology Division, Department of Medicine, University of Hong Kong, Hong Kong SAR, China
{dagger} EBR Systems, Inc., Sunnyvale, California
{ddagger} Cardiology Division, Greenlane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand

Manuscript received October 16, 2006; revised manuscript received March 22, 2007, accepted April 18, 2007.

* Reprint requests and correspondence: Dr. Kathy L. Lee, Cardiology Division, Department of Medicine, Queen Mary Hospital, 102, Pokfulam Road, Hong Kong SAR, China. (Email: klflee{at}hku.hk).

Objectives: The purpose of this study was to evaluate the feasibility and safety of a novel technology that uses energy transfer from an ultrasound transmitter to achieve cardiac stimulation without the use of a pacing lead in humans.

Background: To overcome the limitations of pacemaker leads, a new technology enabling stimulation without the use of a lead is desirable.

Methods: A steerable bipolar electrophysiology catheter incorporating a receiver electrode into the tip and circuitry to convert ultrasound energy to electrical energy was inserted transvenously into the heart. An ultrasound transmitting transducer was placed on the chest wall with ultrasound gel. Ultrasound energy was amplitude-adjusted and transmitted at 313 to 385 kHz. The output waveform of the receiver electrode was monitored while the transmitter was moved on the chest wall to target the receiver. The ultrasound transmission amplitude was limited to a mechanical index of 1.9, the maximum allowed for ultrasound imaging systems. Ultrasound-mediated pacing with minimum voltage but consistent capture was obtained for 12 s.

Results: Twenty-four patients (48 ± 12 years) were tested during or after completion of clinical electrophysiology procedures. A total of 80 pacing sites were tested (mean 3.3 sites/patient): 12 right atrial, 35 right ventricular, and 33 left ventricular (31 endocardial) sites. The transmit-to-receive distance was 11.3 ± 3.2 cm (range 5.3 to 22.5 cm). Ultrasound-mediated pacing was achieved at all 80 test sites, with consistent capture at 77 sites. The mechanical index during pacing was 0.5 ± 0.3 (range 0.1 to 1.5). The mean ultrasound-mediated capture threshold was 1.01 ± 0.64 V. There was no adverse event related to ultrasound pacing. No patient experienced discomfort during pacing.

Conclusions: The feasibility and safety of pacing usng ultrasound energy has been shown acutely.

Abbreviations and Acronyms
  CPK = creatine phosphokinase
  CRT = cardiac resynchronization therapy
  CS = coronary sinus
  CV = coronary vein
  ECG = electrocardiogram
  ISPPA = spatial peak pulse average intensity
  ISPTA = spatial peak temporal average intensity
  LV = left ventricle
  MI = mechanical index
  RA = right atrium
  RV = right ventricle
  TI = thermal index




This article has been cited by other articles:


Home page
Circ Arrhythm ElectrophysiolHome page
C. van Deursen, I. E. van Geldorp, L. M. Rademakers, A. van Hunnik, M. Kuiper, C. Klersy, A. Auricchio, and F. W. Prinzen
Left Ventricular Endocardial Pacing Improves Resynchronization Therapy in Canine Left Bundle-Branch Hearts
Circ Arrhythm Electrophysiol, October 1, 2009; 2(5): 580 - 587.
[Abstract] [Full Text] [PDF]


Home page
ESC Textbook of Cardiovascular MedicineHome page
P. E. Vardas, H. E. Mavrakis, and W. D. Toff
CHAPTER 27 Bradycardia
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement