Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2006; 48:532-537, doi:10.1016/j.jacc.2006.03.046 (Published online 11 July 2006).
© 2006 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.03.046v1
48/3/532    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Iida, K.
Right arrow Articles by Siegel, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Iida, K.
Right arrow Articles by Siegel, R. J.

CLINICAL RESEARCH: ULTRASOUND AND VASCULAR FUNCTION

Noninvasive Low-Frequency Ultrasound Energy Causes Vasodilation in Humans

Kiyoshi Iida, MD, Huai Luo, MD, Kohsuke Hagisawa, MD, Takashi Akima, MD, Prediman K. Shah, MD, FACC, Tasneem Z. Naqvi, MD, FACC and Robert J. Siegel, MD, FACC*

Division of Cardiology, Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California

Manuscript received January 23, 2006; revised manuscript received March 10, 2006, accepted March 16, 2006.

* Reprint requests and correspondence: Dr. Robert J. Siegel, Division of Cardiology, Room 5623, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, California 90048 (Email: siegel{at}cshs.org).

OBJECTIVES: We evaluated the potential vasodilator effects of transcutaneous low-frequency ultrasound (US) in human brachial arteries.

BACKGROUND: Recent data show that transthoracic low-frequency US energy results in canine coronary artery vasodilation.

METHODS: Brachial artery diameters were measured before and after low-frequency US (29 kHz, 1.4 W/cm2) exposure using US imaging with a linear-array transducer. We assessed the time course of diameter changes after US in 20 subjects. In 10 of 20 subjects, brachial artery flow-mediated vasodilation (FMD) was measured to compare the effect of US to a standard method of evaluating endothelial function.

RESULTS: Significant vasodilation was seen after 2 min of US compared with baseline values. At 5 min of US, the brachial artery diameter increased by 4.1%. In addition, the arteries continued to dilate after US exposure. At 3 min after US there was a 5.4%, and at 5 min after US a 6.0% increase in vessel diameter (p < 0.001). These diameters returned to baseline dimensions about 20 min after stopping US. Ultrasound-mediated vasodilation and percentage FMD showed good correlation (r = 0.87; p < 0.001).

CONCLUSIONS: This is the first study to demonstrate that noninvasive transcutaneous low-frequency US energy dilates human brachial arteries. This arterial vasodilator effect has a rapid onset (within 2 min), lasts about 20 min, and is similar in magnitude to that of FMD. The vasodilator effect of US may have diagnostic and therapeutic potential in patients with or at risk for vascular disease.

Abbreviations and Acronyms
  NO = nitric oxide
  FMD = flow-mediated vasodilation
  UMD = ultrasound-mediated vasodilation
  US = ultrasound
  VTI = velocity-time integral




This article has been cited by other articles:


Home page
CirculationHome page
S. Kaul
Sonothrombolysis: A Universally Applicable and Better Way to Treat Acute Myocardial Infarction and Stroke? Who Is Going to Fund the Research?
Circulation, March 17, 2009; 119(10): 1358 - 1360.
[Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement