CLINICAL RESEARCH: INTERVENTIONAL CARDIOLOGY
Slow-Flow Phenomenon During Carotid Artery Intervention With Embolic Protection Devices
Predictors and Clinical Outcome
Ivan P. Casserly, MB, BCh*,
Alex Abou-Chebl, MD ,
Robert B. Fathi, MD, PhD ,
David S. Lee, MD ,
Jacqueline Saw, MD ,
Jose E. Exaire, MD ,
Samir R. Kapadia, MD ,
Christopher T. Bajzer, MD and
Jay S. Yadav, MD ,*
* Denver Veterans Affairs Medical Center and University of Colorado Health Sciences Center, Denver, Colorado
Department of Cardiovascular Medicine, Cleveland Clinic Foundation, Cleveland, Ohio
Vancouver General Hospital, Vancouver, Canada
National Institute of Health, Mexico City, Mexico
Manuscript received January 26, 2005;
revised manuscript received May 18, 2005,
accepted May 31, 2005.
* Reprint requests and correspondence: Dr. Jay S. Yadav, Department of Cardiovascular Medicine, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Desk F25, Cleveland, Ohio, 44195 (Email: yadavj{at}ccf.org).
OBJECTIVES: The purpose of this research was to define the predictors of the "slow-reflow" phenomenon during carotid artery intervention with filter-type embolic protection devices (EPDs) and to determine its prognostic significance.
BACKGROUND: During carotid artery intervention using filter-type EPDs, we have observed cases in which there is angiographic evidence of a significant reduction in antegrade flow in the internal carotid artery proximal to the filter device, termed "slow-flow." The predictors of this phenomenon and its prognostic significance are unknown.
METHODS: Using a single-center prospective carotid intervention registry, patients with slow-flow were compared to patients with normal flow during carotid intervention with respect to clinical, procedural, and lesion characteristics, and the 30-day incidence of death and stroke.
RESULTS: A total of 414 patients underwent 453 carotid artery interventions using EPDs. Slow-flow occurred in 42 patients (10.1%) undergoing 42 carotid interventions (9.3%), and most commonly occurred after post-stent balloon dilatation (71.4%). Multivariate logistic regression analysis identified the following predictors of slow-flow: recent history (<6 months) of stroke or transient ischemic attack (odds ratio [OR] 2.8, 95% confidence interval [CI] 1.4 to 5.6, p = 0.004), increased stent diameter (OR 1.4, 95% CI 1.02 to 1.94, p = 0.044), and increased patient age (OR 1.05, 95% CI 1.01 to 1.09, p = 0.025). Among patients with slow-flow, the 30-day incidence of stroke or death was 9.5% compared to 2.9% in patients with normal flow (chi-square = 4.73, p = 0.03). This difference was driven by the disparity in the 30-day incidence of stroke (9.5% vs. 1.7%).
CONCLUSIONS: Slow-flow during carotid intervention with EPDs is a frequent event that is associated with an excess risk of periprocedural stroke. The association of the phenomenon with clinically symptomatic carotid lesions and use of larger stent diameters suggests that embolization of vulnerable plaque elements may play a pathogenic role.
|
Abbreviations and Acronyms
| | ACT = activated clotting time | | EPD = embolic protection device | | ICA = internal carotid artery | | TIA = transient ischemic attack |
|
This article has been cited by other articles:

|
 |

|
 |
 
K. Bijuklic, A. Wandler, F. Hazizi, and J. Schofer
The PROFI Study (Prevention of Cerebral Embolization by Proximal Balloon Occlusion Compared to Filter Protection During Carotid Artery Stenting): A Prospective Randomized Trial
J. Am. Coll. Cardiol.,
January 25, 2012;
(2012)
j.jacc.2011.11.035v1.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Iwata, T. Mori, H. Tajiri, Y. Miyazaki, and M. Nakazaki
Safety and effectiveness of emergency carotid artery stenting for a high-grade carotid stenosis with intraluminal thrombus under proximal flow control in hyperacute and acute stroke
JNIS,
December 14, 2011;
(2011)
neurintsurg-2011-010147v1.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
T. Sorimachi, K. Nishino, K. Morita, S. Takeuchi, Y. Ito, and Y. Fujii
Blood Flow Changes Caused by Distal Filter Protection and Catheter Aspiration in the Internal Carotid Artery during Carotid Stenting: Evaluation Using Carotid Doppler Sonography
AJNR Am. J. Neuroradiol.,
February 1, 2011;
32(2):
288 - 293.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. L. Keldahl, S. V. Phade, and M. K. Eskandari
Carotid Artery Stenting Using Proximal Balloon Occlusion Embolic Protection
Perspectives in Vascular Surgery and Endovascular Therapy,
September 1, 2010;
22(3):
187 - 193.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
S. R. Dixon, C. L. Grines, and W. W. O'Neill
The Year in Interventional Cardiology
J. Am. Coll. Cardiol.,
April 18, 2006;
47(8):
1689 - 1706.
[Full Text]
[PDF]
|
 |
|
|