CLINICAL RESEARCH: HEART RHYTHM DISORDER
First Human Demonstration of Cardiac Stimulation With Transcutaneous Ultrasound Energy DeliveryImplications for Wireless Pacing With Implantable Devices
Kathy L. Lee, MBBS, FACC*,*,
Chu-Pak Lau, MD, FACC*,
Hung-Fat Tse, MD, FACC*,
Debra S. Echt, MD, FACC ,1,
David Heaven, MBChB ,
Warren Smith, MBChB and
Margaret Hood, MBChB
* Cardiology Division, Department of Medicine, University of Hong Kong, Hong Kong SAR, China
EBR Systems, Inc., Sunnyvale, California
Cardiology Division, Greenlane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand.
Manuscript received October 16, 2006;
revised manuscript received March 22, 2007,
accepted April 18, 2007.
* Reprint requests and correspondence: Dr. Kathy L. Lee, Cardiology Division, Department of Medicine, Queen Mary Hospital, 102, Pokfulam Road, Hong Kong SAR, China. (Email: klflee{at}hku.hk).
Objectives: The purpose of this study was to evaluate the feasibility and safety of a novel technology that uses energy transfer from an ultrasound transmitter to achieve cardiac stimulation without the use of a pacing lead in humans.
Background: To overcome the limitations of pacemaker leads, a new technology enabling stimulation without the use of a lead is desirable.
Methods: A steerable bipolar electrophysiology catheter incorporating a receiver electrode into the tip and circuitry to convert ultrasound energy to electrical energy was inserted transvenously into the heart. An ultrasound transmitting transducer was placed on the chest wall with ultrasound gel. Ultrasound energy was amplitude-adjusted and transmitted at 313 to 385 kHz. The output waveform of the receiver electrode was monitored while the transmitter was moved on the chest wall to target the receiver. The ultrasound transmission amplitude was limited to a mechanical index of 1.9, the maximum allowed for ultrasound imaging systems. Ultrasound-mediated pacing with minimum voltage but consistent capture was obtained for 12 s.
Results: Twenty-four patients (48 ± 12 years) were tested during or after completion of clinical electrophysiology procedures. A total of 80 pacing sites were tested (mean 3.3 sites/patient): 12 right atrial, 35 right ventricular, and 33 left ventricular (31 endocardial) sites. The transmit-to-receive distance was 11.3 ± 3.2 cm (range 5.3 to 22.5 cm). Ultrasound-mediated pacing was achieved at all 80 test sites, with consistent capture at 77 sites. The mechanical index during pacing was 0.5 ± 0.3 (range 0.1 to 1.5). The mean ultrasound-mediated capture threshold was 1.01 ± 0.64 V. There was no adverse event related to ultrasound pacing. No patient experienced discomfort during pacing.
Conclusions: The feasibility and safety of pacing usng ultrasound energy has been shown acutely.
|
Abbreviations and Acronyms
| | CPK = creatine phosphokinase | | CRT = cardiac resynchronization therapy | | CS = coronary sinus | | CV = coronary vein | | ECG = electrocardiogram | | ISPPA = spatial peak pulse average intensity | | ISPTA = spatial peak temporal average intensity | | LV = left ventricle | | MI = mechanical index | | RA = right atrium | | RV = right ventricle | | TI = thermal index |
|
This article has been cited by other articles:

|
 |

|
 |
 
D. DeFaria Yeh, K. Lease Lonergan, D. Fu, R. W. Yeh, D. S. Echt, and E. Foster
Clinical factors and echocardiographic techniques related to the presence, size, and location of acoustic windows for leadless cardiac pacing
Europace,
December 1, 2011;
13(12):
1760 - 1765.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. van Deursen, I. E. van Geldorp, L. M. Rademakers, A. van Hunnik, M. Kuiper, C. Klersy, A. Auricchio, and F. W. Prinzen
Left Ventricular Endocardial Pacing Improves Resynchronization Therapy in Canine Left Bundle-Branch Hearts
Circ Arrhythm Electrophysiol,
October 1, 2009;
2(5):
580 - 587.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. E. Vardas, H. E. Mavrakis, and W. D. Toff
CHAPTER 27 Bradycardia
ESC Textbook of Cardiovascular Medicine,
January 1, 2009;
2(1):
med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|