CLINICAL RESEARCH: HEART RHYTHM DISORDER
"Indeterminate" Microvolt T-Wave Alternans Tests Predict High Risk of Death or Sustained Ventricular Arrhythmias in Patients With Left Ventricular Dysfunction
Elizabeth S. Kaufman, MD, FACC*,*,
Daniel M. Bloomfield, MD, FACC ,
Richard C. Steinman, AB ,
Pearila B. Namerow, PhD ,
Ottorino Costantini, MD*,
Richard J. Cohen, MD, PhD and
J. Thomas Bigger, Jr, MD
* Heart and Vascular Research Center, MetroHealth Campus of Case Western Reserve University, Cleveland, Ohio
Columbia University, New York, New York
Massachusetts Institute of Technology, Cambridge, Massachusetts.
Manuscript received January 5, 2006;
revised manuscript received May 30, 2006,
accepted June 5, 2006.
* Reprint requests and correspondence: Dr. Elizabeth S. Kaufman, Heart and Vascular Research Center, Hamann 3rd Floor, MetroHealth Campus, Case Western Reserve University, 2500 MetroHealth Drive, Cleveland, Ohio 44109-1998. (Email: ekaufman{at}metrohealth.org).
OBJECTIVES: This study tested the hypothesis that an "indeterminate" microvolt T-wave alternans (MTWA) test, when due to ectopy, unsustained MTWA, or low exercise heart rate (HR), has prognostic significance similar to a positive MTWA test.
BACKGROUND: MTWA testing, used to stratify risk of sudden or total mortality in patients with structural heart disease, has been limited by a substantial number of "indeterminate" tests. Indeterminate tests are due to patient factorsexcessive ventricular ectopy during exercise, unsustained MTWA, or failure to achieve a HR of 105 beats/min for 1 minor technical factors such as a noisy recording or an exercise protocol that causes an excessively rapid rise in HR.
METHODS: Patients in sinus rhythm with left ventricular ejection fraction 0.40 underwent MTWA exercise tests, analyzed with the spectral method and classified by a computerized interpretation algorithm. The primary end point was all-cause mortality or documented non-fatal sustained ventricular arrhythmia (SVA). "Indeterminate" tests were reviewed jointly by 2 readers blinded to subsequent events to determine the primary reason for indeterminacy.
RESULTS: Participants (N = 549) were 56 ± 13 years and 71% male; 49% had ischemic cardiomyopathy. There were 40 deaths and 11 non-fatal SVA. Most (94%) indeterminate results were due to patient factors. The 2-year rate for death or SVA was 17.8% in patients with an "indeterminate" MTWA test compared with 12.3% in those with a positive test.
CONCLUSIONS: In patients with left ventricular dysfunction, an "indeterminate" MTWA test due to patient factors predicted death or SVA at least as well as a positive test.
|
Abbreviations and Acronyms
| | ACE = angiotensin-converting enzyme | | ARB = angiotensin receptor blocker | | CI = confidence interval | | HR = heart rate | | ICD = implantable cardioverter-defibrillator | | LVEF = left ventricular ejection fraction | | MI = myocardial infarction | | MTWA = microvolt T-wave alternans | | SVA = sustained ventricular arrhythmia |
|
This article has been cited by other articles:

|
 |

|
 |
 
K. Kraaier, P. M.J. Verhorst, J. van der Palen, P. F.H.M. van Dessel, A. A.M. Wilde, and M. F. Scholten
Microvolt T-wave alternans during exercise and pacing are not comparable
Europace,
October 1, 2009;
11(10):
1375 - 1380.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. J. Rashba
Anger management may save your life new insights into emotional precipitants of ventricular arrhythmias.
J. Am. Coll. Cardiol.,
March 3, 2009;
53(9):
779 - 781.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
O. Costantini, S. H. Hohnloser, M. M. Kirk, B. B. Lerman, J. H. Baker II, B. Sethuraman, M. M. Dettmer, D. S. Rosenbaum, and for the ABCD Trial Investigators
The ABCD (Alternans Before Cardioverter Defibrillator) Trial: strategies using T-wave alternans to improve efficiency of sudden cardiac death prevention.
J. Am. Coll. Cardiol.,
February 10, 2009;
53(6):
471 - 479.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. K. Feld and P. Clopton
Comparability of noninvasive microvolt T-wave alternans versus invasive ventricular programmed stimulation to guide implantable cardioverter-defibrillator implantation in patients at risk of sudden death.
J. Am. Coll. Cardiol.,
February 10, 2009;
53(6):
480 - 482.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Chow, D. J. Kereiakes, J. Onufer, A. Woelfel, S. Gursoy, B. J. Peterson, M. L. Brown, W. Pu, D. G. Benditt, and on behalf of the MASTER Trial Investigators
Does Microvolt T-Wave Alternans Testing Predict Ventricular Tachyarrhythmias in Patients With Ischemic Cardiomyopathy and Prophylactic Defibrillators?: The MASTER (Microvolt T Wave Alternans Testing for Risk Stratification of Post-Myocardial Infarction Patients) Trial
J. Am. Coll. Cardiol.,
November 11, 2008;
52(20):
1607 - 1615.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. R. Gold, J. H. Ip, O. Costantini, J. E. Poole, S. McNulty, D. B. Mark, K. L. Lee, and G. H. Bardy
Role of Microvolt T-Wave Alternans in Assessment of Arrhythmia Vulnerability Among Patients With Heart Failure and Systolic Dysfunction: Primary Results From the T-Wave Alternans Sudden Cardiac Death in Heart Failure Trial Substudy
Circulation,
November 11, 2008;
118(20):
2022 - 2028.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. C. Myles, C. E. Jackson, I. Tsorlalis, M. C. Petrie, J. J. V. McMurray, and S. M. Cobbe
Is Microvolt T-Wave Alternans the Answer to Risk Stratification in Heart Failure?
Circulation,
December 18, 2007;
116(25):
2984 - 2991.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. A. Salerno-Uriarte, G. M. De Ferrari, C. Klersy, R. F.E. Pedretti, M. Tritto, L. Sallusti, L. Libero, G. Pettinati, G. Molon, A. Curnis, et al.
Prognostic Value of T-Wave Alternans in Patients With Heart Failure Due to Nonischemic Cardiomyopathy: Results of the ALPHA Study
J. Am. Coll. Cardiol.,
November 6, 2007;
50(19):
1896 - 1904.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. P. Anderson
Risk Assessment for Defibrillator Therapy: Il Trittico
J. Am. Coll. Cardiol.,
September 18, 2007;
50(12):
1158 - 1160.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. J. Cantillon, K. M. Stein, S. M. Markowitz, S. Mittal, B. K. Shah, D. P. Morin, E. S. Zacks, M. Janik, S. Ageno, A. C. Mauer, et al.
Predictive Value of Microvolt T-Wave Alternans in Patients With Left Ventricular Dysfunction
J. Am. Coll. Cardiol.,
July 10, 2007;
50(2):
166 - 173.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. M. Scheinman and E. Keung
The Year in Clinical Cardiac Electrophysiology
J. Am. Coll. Cardiol.,
May 22, 2007;
49(20):
2061 - 2069.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. N. DeMaria, O. Ben-Yehuda, G. K. Feld, G. S. Ginsburg, B. H. Greenberg, W. Y.W. Lew, J. A.C. Lima, A. S. Maisel, J. Narula, D. J. Sahn, et al.
Highlights of the Year in JACC 2006
J. Am. Coll. Cardiol.,
January 30, 2007;
49(4):
509 - 527.
[Full Text]
[PDF]
|
 |
|
|