Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2006; 48:805-811, doi:10.1016/j.jacc.2006.03.055 (Published online 24 July 2006).
© 2006 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.03.055v1
48/4/805    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (25)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lakkireddy, D.
Right arrow Articles by Tchou, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lakkireddy, D.
Right arrow Articles by Tchou, P. J.

CLINICAL RESEARCH: CARDIOVASCULAR CONSEQUENCES OF STUN GUN

Effects of Cocaine Intoxication on the Threshold for Stun Gun Induction of Ventricular Fibrillation

Dhanunjaya Lakkireddy, MD*, Donald Wallick, PhD*, Kay Ryschon, MS*, Mina K. Chung, MD, FACC*, Jagdish Butany, MD{dagger}, David Martin, MD*, Walid Saliba, MD, FACC*, William Kowalewski, BS*, Andrea Natale, MD, FACC* and Patrick J. Tchou, MD, FACC*,*

* Cleveland Clinic Foundation, Cleveland, Ohio
{dagger} Toronto General Hospital, Toronto, Ontario, Canada.

Manuscript received January 17, 2006; revised manuscript received March 5, 2006, accepted March 20, 2006.

* Reprint requests and correspondence: Dr. Patrick J. Tchou, Section of Cardiac Pacing and Electrophysiology, Department of Cardiovascular Medicine/F15, 9500 Euclid Avenue, Cleveland, Ohio 44195. (Email: tchoup{at}ccf.org).

OBJECTIVES: This study sought to assess cocaine’s effects on Taser-induced ventricular fibrillation (VF) threshold in a pig model.

BACKGROUND: Stun guns are increasingly used by law enforcement officials to restrain violent subjects, who are frequently intoxicated with cocaine and other drugs of abuse. The interaction of cocaine and the stun gun on VF induction is unknown.

METHODS: We tested five adult pigs using a custom device built to deliver multiples of standard neuromuscular incapacitating (NMI) discharge that matched the waveform of a commercially available electrical stun gun (Taser X-26, Taser International, Scottsdale, Arizona). The NMI discharges were applied in a step-up and step-down fashion at 5 body locations. End points included determination of maximum safe multiple, minimum VF-inducing multiple, and ventricular fibrillation threshold (VFT) before and after cocaine infusion.

RESULTS: Standard NMI discharges (x1) did not cause VF at any of the 5 locations before or after cocaine infusion. The maximum safe multiple, minimum VF-inducing multiple, and VFT of NMI application increased with increasing electrode distance from the heart. There was a 1.5- to 2-fold increase in these values at each position after cocaine infusion, suggesting decreased cardiac vulnerability for VF. Cocaine increased the required strength of NMI discharge that caused 2:1 or 3:1 ventricular capture ratios at all of the positions. No significant changes in creatine kinase-MB and troponin-I were seen.

CONCLUSIONS: Cocaine increased the VFT of NMI discharges at all dart locations tested and reduced cardiac vulnerability to VF. The application of cocaine increased the safety margin by 50% to 100% above the baseline safety margin.

Abbreviations and Acronyms
  CK = creatine kinase
  ECG = electrocardiogram
  maxSM = maximum safe multiple
  minVFIM = minimum ventricular fibrillation-inducing multiple
  NMI = neuromuscular incapacitating
  PMI = point of maximum impulse
  SN = sternal notch
  VF = ventricular fibrillation
  VFT = ventricular fibrillation threshold




This article has been cited by other articles:


Home page
Emerg. Med. J.Home page
W P Bozeman, D G Barnes Jr, J E Winslow III, J C Johnson III, C H Phillips, and R Alson
Immediate cardiovascular effects of the Taser X26 conducted electrical weapon
Emerg. Med. J., August 1, 2009; 26(8): 567 - 570.
[Abstract] [Full Text] [PDF]


Home page
CMAJHome page
M. W. Kroll PhD, H. Calkins MD, R. M. Luceri MD, M. A. Graham MD, and W. G. Heegaard MD MPH
TASER safety
Can. Med. Assoc. J., September 23, 2008; 179(7): 677 - 678.
[Full Text] [PDF]


Home page
CMAJHome page
K. Nanthakumar MD, S. Masse PEng MASc, K. Umapathy PhD, P. Dorian MD, E. Sevaptsidis, and M. Waxman MD
Cardiac stimulation with high voltage discharge from stun guns
Can. Med. Assoc. J., May 20, 2008; 178(11): 1451 - 1457.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. Lakkireddy, A. Khasnis, J. Antenacci, K. Ryshcon, M. K. Chung, D. Wallick, W. Kowalewski, D. Patel, H. Mlcochova, A. Kondur, et al.
Do electrical stun guns (TASER-X26(R)) affect the functional integrity of implantable pacemakers and defibrillators?
Europace, July 1, 2007; 9(7): 551 - 556.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. J. Tchou
Reply
J. Am. Coll. Cardiol., February 13, 2007; 49(6): 733 - 733.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. J. Pippin
Taser Research in Pigs Not Helpful
J. Am. Coll. Cardiol., February 13, 2007; 49(6): 731 - 732.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. W. Kroll, H. Calkins, and R. M. Luceri
Electronic Control Devices and the Clinical Milieu
J. Am. Coll. Cardiol., February 13, 2007; 49(6): 732 - 732.
[Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement