CLINICAL RESEARCH: CARDIOVASCULAR CONSEQUENCES OF STUN GUN
Effects of Cocaine Intoxication on the Threshold for Stun Gun Induction of Ventricular Fibrillation
Dhanunjaya Lakkireddy, MD*,
Donald Wallick, PhD*,
Kay Ryschon, MS*,
Mina K. Chung, MD, FACC*,
Jagdish Butany, MD ,
David Martin, MD*,
Walid Saliba, MD, FACC*,
William Kowalewski, BS*,
Andrea Natale, MD, FACC* and
Patrick J. Tchou, MD, FACC*,*
* Cleveland Clinic Foundation, Cleveland, Ohio
Toronto General Hospital, Toronto, Ontario, Canada.
Manuscript received January 17, 2006;
revised manuscript received March 5, 2006,
accepted March 20, 2006.
* Reprint requests and correspondence: Dr. Patrick J. Tchou, Section of Cardiac Pacing and Electrophysiology, Department of Cardiovascular Medicine/F15, 9500 Euclid Avenue, Cleveland, Ohio 44195. (Email: tchoup{at}ccf.org).
OBJECTIVES: This study sought to assess cocaines effects on Taser-induced ventricular fibrillation (VF) threshold in a pig model.
BACKGROUND: Stun guns are increasingly used by law enforcement officials to restrain violent subjects, who are frequently intoxicated with cocaine and other drugs of abuse. The interaction of cocaine and the stun gun on VF induction is unknown.
METHODS: We tested five adult pigs using a custom device built to deliver multiples of standard neuromuscular incapacitating (NMI) discharge that matched the waveform of a commercially available electrical stun gun (Taser X-26, Taser International, Scottsdale, Arizona). The NMI discharges were applied in a step-up and step-down fashion at 5 body locations. End points included determination of maximum safe multiple, minimum VF-inducing multiple, and ventricular fibrillation threshold (VFT) before and after cocaine infusion.
RESULTS: Standard NMI discharges (x1) did not cause VF at any of the 5 locations before or after cocaine infusion. The maximum safe multiple, minimum VF-inducing multiple, and VFT of NMI application increased with increasing electrode distance from the heart. There was a 1.5- to 2-fold increase in these values at each position after cocaine infusion, suggesting decreased cardiac vulnerability for VF. Cocaine increased the required strength of NMI discharge that caused 2:1 or 3:1 ventricular capture ratios at all of the positions. No significant changes in creatine kinase-MB and troponin-I were seen.
CONCLUSIONS: Cocaine increased the VFT of NMI discharges at all dart locations tested and reduced cardiac vulnerability to VF. The application of cocaine increased the safety margin by 50% to 100% above the baseline safety margin.
|
Abbreviations and Acronyms
| | CK = creatine kinase | | ECG = electrocardiogram | | maxSM = maximum safe multiple | | minVFIM = minimum ventricular fibrillation-inducing multiple | | NMI = neuromuscular incapacitating | | PMI = point of maximum impulse | | SN = sternal notch | | VF = ventricular fibrillation | | VFT = ventricular fibrillation threshold |
|
This article has been cited by other articles:

|
 |

|
 |
 
W P Bozeman, D G Barnes Jr, J E Winslow III, J C Johnson III, C H Phillips, and R Alson
Immediate cardiovascular effects of the Taser X26 conducted electrical weapon
Emerg. Med. J.,
August 1, 2009;
26(8):
567 - 570.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. W. Kroll PhD, H. Calkins MD, R. M. Luceri MD, M. A. Graham MD, and W. G. Heegaard MD MPH
TASER safety
Can. Med. Assoc. J.,
September 23, 2008;
179(7):
677 - 678.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Nanthakumar MD, S. Masse PEng MASc, K. Umapathy PhD, P. Dorian MD, E. Sevaptsidis, and M. Waxman MD
Cardiac stimulation with high voltage discharge from stun guns
Can. Med. Assoc. J.,
May 20, 2008;
178(11):
1451 - 1457.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Lakkireddy, A. Khasnis, J. Antenacci, K. Ryshcon, M. K. Chung, D. Wallick, W. Kowalewski, D. Patel, H. Mlcochova, A. Kondur, et al.
Do electrical stun guns (TASER-X26(R)) affect the functional integrity of implantable pacemakers and defibrillators?
Europace,
July 1, 2007;
9(7):
551 - 556.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. J. Tchou
Reply
J. Am. Coll. Cardiol.,
February 13, 2007;
49(6):
733 - 733.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. J. Pippin
Taser Research in Pigs Not Helpful
J. Am. Coll. Cardiol.,
February 13, 2007;
49(6):
731 - 732.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. W. Kroll, H. Calkins, and R. M. Luceri
Electronic Control Devices and the Clinical Milieu
J. Am. Coll. Cardiol.,
February 13, 2007;
49(6):
732 - 732.
[Full Text]
[PDF]
|
 |
|
|