cardiology careers collections past issues search home
     

J Am Coll Cardiol, 2006; 47:2172-2179, doi:10.1016/j.jacc.2006.01.063 (Published online 12 May 2006).
© 2006 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.01.063v1
47/11/2172    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jiménez-Quevedo, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jiménez-Quevedo, P.

CLINICAL RESEARCH: INTERVENTIONAL CARDIOLOGY

Vascular Effects of Sirolimus-Eluting Versus Bare-Metal Stents in Diabetic Patients

Three-Dimensional Ultrasound Results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial

Pilar Jiménez-Quevedo, MD*,1, Manel Sabaté, MD, PhD*,*, Dominick J. Angiolillo, MD{dagger}, Marco A. Costa, MD, PhD{dagger}, Fernando Alfonso, MD, PhD*, Joan Antoni Gómez-Hospital, MD, PhD{ddagger}, Rosana Hernández-Antolín, MD, PhD*, Camino Bañuelos, MD*, Javier Goicolea, MD, PhD§, Francisco Fernández-Avilés, MD, PhD||, Theodore Bass, MD*,{dagger},{ddagger},§,||, Javier Escaned, MD, PhD*, Raul Moreno, MD*, Cristina Fernández, MD, PhD*, Carlos Macaya, MD, PhD* for the DIABETES Investigators

* San Carlos University Hospital, Madrid, Spain
{dagger} University of Florida Cardiovascular Imaging Core Laboratories, Jacksonville, Florida
{ddagger} "Prínceps d’Espanya" University Hospital, Barcelona, Spain
§ "Do Meixoeiro" University Hospital, Vigo, Spain
|| Clínico University Hospital, Valladolid, Spain

Manuscript received October 31, 2005; revised manuscript received December 29, 2005, accepted January 16, 2006.

* Reprint requests and correspondence: Dr. Manel Sabaté, Hospital Clínico San Carlos, Plaza Cristo Rey s/n, 28040 Madrid, Spain. (Email: manelsabate1{at}telefonica.net).

OBJECTIVES: A predefined intravascular ultrasound (IVUS) substudy was performed to evaluate the vascular effects of sirolimus-eluting stent (SES) versus bare-metal stent (BMS).

BACKGROUND: The Diabetes and Sirolimus-Eluting Stent (DIABETES) trial is a prospective, multicenter, randomized, controlled trial aimed at demonstrating the efficacy of the SES compared with BMS in diabetic patients.

METHODS: Serial intravascular ultrasound analyses were performed in 140 lesions (SES = 75; BMS = 65) immediately after stent implantation and at nine-month follow-up. Vessel, luminal, and stent mean areas and volumes were evaluated at both edges and within the stented segment. Qualitative assessment of residual dissections and stent apposition were also performed.

RESULTS: Baseline clinical and angiographic characteristics were similar between groups. At 9 months, in-stent neointimal hyperplasia (NIH) mean area and volume were significantly reduced in the SES group (median NIH area 0.01 mm2 [0.0 to 0.1] vs. 2.0 mm2 [1.0 to 2.9] and median NIH volume 0.11 mm3 [0 to 2.1] vs. 35.3 mm3 [16.6 to 62.6]; both p < 0.0001). In the SES group, stent edges evidenced significant increase in lumen dimensions mainly due to significant increase in vessel volume, whereas those of the BMS group presented vessel shrinkage leading to significant lumen reduction. Late acquired incomplete stent apposition was observed in 11 lesions (14.7%) in the SES group and 0 in the BMS group (p = 0.001). At one year, no stent thromboses occurred in malapposed stents.

CONCLUSIONS: The SES implantation effectively inhibits NIH in diabetic patients. The antirestenotic effect of SES is also appreciated at the stent edges. Late acquired stent malapposition is a frequent phenomenon in diabetic patients treated with SES.

Abbreviations and Acronyms
  BMS = bare-metal stent
  DIABETES = Diabetes and Sirolimus-Eluting Stent trial
  EEM = external elastic membrane
  ISA = incomplete stent apposition
  IVUS = intravascular ultrasound
  NIH = neointimal hyperplasia
  SES = sirolimus-eluting stent




This article has been cited by other articles:


Home page
Eur Heart JHome page
L. O. Jensen, M. Maeng, P. Thayssen, E. H. Christiansen, K. N. Hansen, A. Galloe, H. Kelbaek, J. F. Lassen, and L. Thuesen
Neointimal hyperplasia after sirolimus-eluting and paclitaxel-eluting stent implantation in diabetic patients: The Randomized Diabetes and Drug-Eluting Stent (DiabeDES) Intravascular Ultrasound Trial
Eur. Heart J., November 2, 2008; 29(22): 2733 - 2741.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Camenzind, P. G. Steg, and W. Wijns
Response to Letter Regarding Article, "Stent Thrombosis Late After Implantation of First-Generation Drug-Eluting Stents: A Cause for Concern"
Circulation, October 16, 2007; 116(16): e390 - e390.
[Full Text] [PDF]


Home page
Eur Heart JHome page
P. Jimenez-Quevedo, M. Sabate, D. J. Angiolillo, F. Alfonso, R. Hernandez-Antolin, M. SanMartin, J. A. Gomez-Hospital, C. Banuelos, J. Escaned, R. Moreno, et al.
Long-term clinical benefit of sirolimus-eluting stent implantation in diabetic patients with de novo coronary stenoses: long-term results of the DIABETES trial
Eur. Heart J., August 2, 2007; 28(16): 1946 - 1952.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. R. Holmes Jr
Coming close and then pulling away
Eur. Heart J., June 1, 2007; 28(11): 1275 - 1276.
[Full Text] [PDF]


Home page
CirculationHome page
E. Camenzind, P. G. Steg, and W. Wijns
A Cause for Concern
Circulation, March 20, 2007; 115(11): 1440 - 1455.
[Full Text] [PDF]



 
  cardiology careers collections past issues search home