JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 2006; 47:213-214, doi:10.1016/j.jacc.2005.10.006 (Published online 13 December 2005).
© 2005 by the American College of Cardiology Foundation
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2005.10.006v1
47/1/213    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shanmugam, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shanmugam, G.

LETTERS TO THE EDITOR: LETTERS TO THE EDITOR

Mitral Prosthesis Mismatch: Hemodynamic Phenomenon or Geometric Discrepancy?

Ganesh Shanmugam, MBBS, MS, MCh, FRCS*

* Department of Cardiac Surgery, Royal Hospital for Sick Children, Dalnair Street, Glasgow G3 8SJ United Kingdom (Email: sgunpat{at}hotmail.com).


The recent study by Li et al. (1) has several limitations. The absence of information on functional capacities, symptoms, preoperative pressure data, or left ventricular (LV) function indices limits the significance of the data.

Perioperative mortality increases when pulmonary artery (PA) pressures exceed 60 mm Hg, which is the cutoff in risk-stratification systems like the Euroscore. A cutoff of 40 mm Hg overestimates the incidence of severe pulmonary hypertension (PHT). Significantly, 15 of 40 patients with prosthesis-patient mismatch (PPM) had postoperative atrial fibrillation (AF). The difference in mean gradients between the PPM and non-PPM groups is merely statistical, but insignificant. The investigators suggest a "simple" strategy of implanting a prosthesis to obtain an indexed effective orifice area (EOA) [EOAI] >1.2 cm2/m2. This arbitrary classification based on EOAI has no surgical significance. There is no mention of valve annular diameters, which is an important consideration in the choice of prosthesis size. The EOAIs for the different prosthesis sizes are unavailable.

Most patients have body surface areas (BSAs) between 1.5 and 2 m2. This translates to absolute EOAs between 1.8 and 2.4 cm2. The minimum absolute EOA of any size 23 prosthesis is 2.54 cm2, which produces an EOAI >1.2 cm2/m2. However, a 23-mm mitral prosthesis is clearly hemodynamically restrictive. Most surgeons would implant larger valves than these; it follows that no patient should have PPM if an EOAI of 1.2 cm2/m2 is considered the minimum! In consequence, the recommendations by Li et al. (1) are nonspecific and impractical.

Twenty-one of 32 patients with preoperative PHT had PPM. In essence, the smallest valves were implanted in those with large BSAs and preoperative PHT. Naturally, many patients would have residual PHT. Could the investigators have actually undersized the prosthesis in many patients?

Native annular diameter places a major restriction on the maximum implantable prosthesis size. Problems with disproportionately large mitral prostheses include LV outflow obstruction, restriction of prosthetic mobility, circumflex artery and conduction system injury. Complications like atrioventricular groove dehiscence and ventricular rupture with large valves are every surgeon's nightmare. A murine annulus will not take an elephantine prosthesis!


    References
 Top
 References
 

  1. Li M, Dumesnil JG, Mathieu P, Pibarot P. Impact of valve prosthesis–patient mismatch on pulmonary arterial pressure after mitral valve replacement J Am Coll Cardiol 2005;45:1034-1040.[Abstract/Free Full Text]




This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2005.10.006v1
47/1/213    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shanmugam, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shanmugam, G.


HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK