Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2009; 53:39-47, doi:10.1016/j.jacc.2008.09.022
© 2009 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow View Related Cardiosource Journal Scan
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mohty, D.
Right arrow Articles by Pibarot, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mohty, D.
Right arrow Articles by Pibarot, P.
Related Collections
Right arrowRelated Article

CLINICAL RESEARCH: VALVULAR HEART DISEASE

Impact of Prosthesis-Patient Mismatch on Long-Term Survival After Aortic Valve Replacement

Influence of Age, Obesity, and Left Ventricular Dysfunction

Dania Mohty, MD, PhD*,{dagger}, Jean G. Dumesnil, MD, FRCPC, FACC*, Najmeddine Echahidi, MD*, Patrick Mathieu, MD, FRCS*, François Dagenais, MD, FRCS*, Pierre Voisine, MD, FRCS* and Philippe Pibarot, DVM, PhD, FACC, FAHA*,*

* Laval Hospital Research Center/Québec Heart Institute, Laval University, Québec, Québec, Canada
{dagger} Université François Rabelais, Faculté de Médecine, Tours, France

Manuscript received March 28, 2008; revised manuscript received August 25, 2008, accepted September 15, 2008.

* Reprint requests and correspondence: Dr. Philippe Pibarot, Laval Hospital, 2725 Chemin Sainte-Foy, Québec, Québec G1V-4G5, Canada (Email: philippe.pibarot{at}med.ulaval.ca).


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
Objectives: This study was designed to evaluate the effect of valve prosthesis-patient mismatch (PPM) on late survival after aortic valve replacement (AVR) and to determine if this effect is modulated by patient age, body mass index (BMI), and pre-operative left ventricular (LV) function.

Background: We recently reported that PPM is an independent predictor of operative mortality after AVR, particularly when associated with LV dysfunction.

Methods: The indexed valve effective orifice area (EOA) was estimated in 2,576 patients having survived AVR and was used to define PPM as not clinically significant if it was >0.85 cm2/m2, as moderate if >0.65 and ≤0.85 cm2/m2, and severe if ≤0.65 cm2/m2.

Results: After adjustment for other risk factors, severe PPM was associated with increased late overall mortality (hazard ratio [HR]: 1.38; p = 0.03) and cardiovascular mortality (HR: 1.63; p = 0.0006) in the whole cohort. Severe PPM was also associated with increased overall mortality in patients <70 years old (HR: 1.77; p = 0.002) and in patients with a BMI <30 kg/m2 (HR: 2.1; p = 0.006), but had no impact in older patients or in obese patients. Moderate PPM was a predictor of mortality in patients with LV ejection fraction <50% (HR: 1.21; p = 0.01), but not in patients with preserved LV function.

Conclusions: Moderate PPM is associated with increased late mortality in patients with LV dysfunction, but with normal prognosis in those with preserved LV function. Notwithstanding the previously demonstrated deleterious effect of severe PPM on early mortality, this factor appears to increase late mortality only in patients <70 years old and/or with a BMI <30 kg/m2 or an LV ejection fraction <50%.

Key Words: aortic valve • heart valve prostheses • mortality • hemodynamics

Abbreviations and Acronyms
  AVR = aortic valve replacement
  BMI = body mass index
  BSA = body surface area
  CABG = coronary artery bypass graft
  CI = confidence interval
  EOA = effective orifice area
  HR = hazard ratio
  LV = left ventricular
  LVEF = left ventricular ejection fraction
  PPM = valve prosthesis-patient mismatch


Valve prosthesis-patient mismatch (PPM) is present when the effective orifice area (EOA) of the inserted prosthetic valve is too small in relation to body size (1,2). Its main hemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. There have been some discrepancies in the published reports about the impact of PPM on post-operative outcomes. Several studies reported that PPM is an independent predictor of cardiac events and mortality after aortic valve replacement (AVR) (3–7); others failed to demonstrate a sigificant effect of PPM on post-operative outcomes (8–12). These discrepancies may be explained, at least in part, by the fact that the investigators used different parameters and criteria to identify PPM and quantify its severity (13,14). Also, these discrepancies may be related to differences in the baseline characteristics of the patient populations included in these studies. Several factors including age, body mass index (BMI), and pre-operative status of left ventricular (LV) function may potentially influence the effect of PPM on post-operative outcomes.

We previously reported that PPM is associated with increased operative mortality after AVR, particularly when associated with LV dysfunction (5). The objective of this study was to evaluate the effect of PPM on late survival after AVR in a large series of patients and to determine if this effect is modulated by patient age, BMI, and pre-operative LV function.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
Eligibility criteria.   All patients who underwent a first AVR with or without coronary artery bypass grafting surgery (CABG) at Laval Hospital between January 1992 and December 2005 were eligible for this study. Of the 2,820 eligible patients, those (n = 167; 6%) who died during or within 30 days of surgery were excluded. Moreover, PPM could not be assessed in 77 (3%) patients because data on normal reference EOA were not available. The study population was thus composed of 2,576 patients (mean age 68.5 ± 10 years; 61% male). Fifty-six percent of these patients received a stented bioprosthesis, 22% received a stentless bioprosthesis, 22% received a mechanical prosthesis, and 44% underwent concomitant CABG. Table 1 shows the distribution of the prosthesis models implanted in this series. Contemporary models were used in 95% of these patients.


View this table:
[in this window]
[in a new window]

 
Table 1 Normal Reference Values of Effective Orifice Areas for Prostheses Implanted in This Series
 
Data collection.   Clinical, operative, and outcomes data were prospectively collected and validated. Database was queried retrospectively. Survival data were obtained from the death certificates of the Registry Office of the Quebec Government. Follow-up information was available in 98% of the patients. LV ejection fraction was available in 2,361 (92%) of the patients.

PPM definition.   The projected indexed EOA was derived from the published normal in vivo EOA values for each model and size of prosthesis implanted in this cohort (Table 1) (15–21), as previously described and validated (13,22). PPM was defined as not clinically significant if the projected indexed EOA was >0.85 cm2/m2, as moderate if it was >0.65 and ≤0.85 cm2/m2, and as severe if it was ≤0.65 cm2/m2.

Statistical methods.   Results are expressed as mean ± SD or percentages unless otherwise specified. The cohort was divided into 3 groups according to PPM severity: nonsignificant, moderate, and severe. Baseline data were compared for statistical significance using a 1-way analysis of variance, chi-square, and Fisher exact test when the number of patients in 1 category was ≤5.

Cumulative probability of survival was estimated with the Kaplan-Meier method and compared between groups by using a log-rank test. Cox proportional-hazards regression models were used to determine whether moderate and severe PPM were associated with survival after adjusting for potential confounding variables. Clinically relevant variables and those with a value of p < 0.1 on univariate analysis were incorporated into the multivariate models. Additional analysis was performed to control for selection bias potentially related to PPM. A propensity score representing the likelihood of having severe PPM was calculated for each patient by using a logistic regression analysis that identified variables independently associated with severe PPM. Variables included in the logistic regression analysis were: sex, BMI, diabetes, predominant aortic stenosis, prosthesis size <21 mm, prosthesis type (bioprosthesis vs. mechanical valve), and cardiopulmonary bypass time. The propensity score was then incorporated into subsequent proportional-hazards models. All statistical analyses were performed with a commercially available software package JMP IN 5.1 (SAS Institute Inc., Cary, North Carolina).


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
Moderate PPM was present in 31% of patients and severe PPM in 2%. Pre-operative and operative data are shown in Table 2. Compared with patients with nonsignificant PPM, those with moderate or severe PPM had a larger BMI and a higher prevalence of female sex, hypertension, diabetes mellitus, and coronary artery disease, as well as a history of renal failure, predominant aortic stenosis, and small prosthesis size (≤21 mm). Patients with moderate PPM, but not those with severe PPM, were significantly older compared with patients with nonsignificant PPM. Mechanical prosthesis implantation was more frequent in the severe PPM group than in the moderate or nonsignificant PPM groups. In a subset of 496 patients in whom a Doppler-echocardiographic examination was performed 1 month after operation in our institution, the measured indexed EOAs were very similar to the projected indexed EOAs in the same groups, and the peak and mean transprosthetic gradients were significantly higher in patients with PPM, and especially those with severe PPM, compared with those with nonsignificant PPM (Table 2).


View this table:
[in this window]
[in a new window]

 
Table 2 Baseline Pre-Operative and Operative Data as a Function of the Severity of Prosthesis-Patient Mismatch
 
Impact of PPM on mortality.   Mean follow-up was 4.8 ± 3.4 years (median, 4.3 years; maximum, 14 years). There were 559 deaths during follow-up. Late survivals were 79 ± 1% at 5 years and 59 ± 2% at 10 years. For patients with severe PPM, 5-year (74 ± 8%) and 10-year survival (40 ± 10%) were significantly lower than for patients with nonsignificant PPM (5-year survival: 84 ± 1%; 10-year survival: 61 ± 2%; p = 0.01) (Fig. 1A). There was also a trend (p = 0.06) toward lower survival in the severe PPM group when compared with the moderate PPM group (5-year survival: 81 ± 2%; 10-year survival: 57 ± 3%) and in the moderate PPM group when compared with the nonsignificant PPM group (p = 0.055).


Figure 1
View larger version (17K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1 Late Overall Survival and Freedom From Cardiovascular Death

Brown line indicates nonsignificant prosthesis-patient mismatch (PPM); green line indicates moderate PPM; orange line shows severe PPM.

 
Among the 559 deaths, 259 (46%) were classified as being of cardiovascular cause. Freedom from cardiovascular-related death was 92 ± 1% at 5 years and 79 ± 2% at 10 years in the whole series, and it was significantly lower in patients with severe PPM (5-year: 78 ± 7%; 10-year: 50 ± 11%) than in those with moderate PPM (5-year: 90 ± 1%; 10-year: 77 ± 3%; p = 0.0004) and in those with nonsignificant PPM (5-year: 93 ± 1%; 10-year: 81 ± 2%; p < 0.0001) (Fig. 1B).

Predictors of mortality.   On univariate analysis (Table 3), the predictors of late post-operative overall mortality were older age, coronary artery disease, hypertension, diabetes, history of renal failure, history of chronic obstructive pulmonary disease, reduced LV ejection fraction (LVEF), the use of a mechanical prosthesis, and severe PPM (age-adjusted hazard ratio [HR]: 1.44; 95% confidence interval [CI]: 1.19 to 1.97; p = 0.01). Moderate PPM also tended to be associated with higher mortality on univariate analysis (age-adjusted HR: 1.07; 95% CI: 0.99 to 1.17; p = 0.06). On multivariate analysis (Table 3), after adjusting for the variables with a p value <0.1 on univariate analysis as well as for sex and BMI, severe PPM was independently associated with increased late mortality (HR: 1.38; 95% CI: 1.03 to 1.77; p = 0.03); moderate PPM did not come out as an independent predictor. After further adjustment for the propensity score, severe PPM remained significantly associated with increased mortality (HR: 1.34; 95% CI: 1.01 to 1.70; p = 0.04) (Table 3).


View this table:
[in this window]
[in a new window]

 
Table 3 Univariate and Multivariate Predictors of Late Overall Mortality
 
Also, severe PPM was independently associated with increased cardiovascular mortality on univariate (age-adjusted HR: 1.80; 95% CI: 1.32 to 2.32; p = 0.0005) and multivariate (HR: 1.63; 95% CI: 1.15 to 2.20; p = 0.0006 and HR: 1.55; 95% CI: 1.16 to 2.25; p = 0.005 after adjustment for propensity score) analyses; moderate PPM was not (Table 4).


View this table:
[in this window]
[in a new window]

 
Table 4 Univariate and Multivariate Predictors of Late Cardiovascular Mortality
 
Interaction between PPM and age, BMI, and LV ejection fraction.   There was a significant interaction between PPM and age (Figs. 2A and 2B). Indeed, severe PPM was associated with increased overall mortality in the subset of patients <70 years old (HR: 1.77; 95% CI: 1.1 to 2.58; p = 0.02), but had no significant effect on survival in older patients. After adjustment for other risk factors and for propensity score, severe PPM was associated with a 1.77-fold increase in mortality (95% CI: 1.24 to 2.39; p = 0.002) in the patients <70 years old.


Figure 2
View larger version (26K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2 Impact of Prosthesis-Patient Mismatch on Late Overall Survival

(A) Patients <70 years old. (B) Patients ≥70 years old. (C) Body mass index (BMI) <30 kg/m2. (D) BMI ≥30 kg/m2. (E) Pre-operative left ventricular ejection fraction (LVEF) <50%. (F) LVEF ≥50%. Brown line indicates nonsignificant prosthesis-patient mismatch (PPM); green line shows moderate PPM in A, B, C, and D, and moderate-severe PPM in E and F; orange line indicates severe PPM.

 
Furthermore, there was also an interaction between PPM and BMI (Figs. 2C and 2D). Severe PPM had a highly significant impact on survival (age-adjusted HR: 1.59; 95% CI: 1.13 to 2.09; p = 0.008) in the subset of patients (n = 1,986; 75%) with a BMI <30 kg/m2. However, this effect was no longer significant in the obese patients (BMI ≥30 kg/m2). After adjustment for other risk factors and for propensity score, severe PPM was associated with a 2.1-fold (95% CI: 1.26 to 3.19; p = 0.006) increase in mortality in patients with a BMI <30 kg/m2.

Moderate-to-severe PPM (indexed EOA ≤0.85 cm2/m2) was an independent predictor of late mortality in patients with a pre-operative LVEF <50% (age-adjusted HR: 1.22; 95% CI: 1.05 to 1.41, p = 0.007; HR adjusted for other risk factors and for propensity score: 1.21; 95% CI: 1.03 to 1.41, p = 0.01), but not in patients with preserved LV systolic function (p = NS) (Figs. 2E and 2F). The number of patients with LV dysfunction and severe PPM was too small to allow for separate analysis in these patients. This can likely be attributed to the fact that a large proportion of the patients having concomitant pre-operative LV dysfunction and severe PPM died in the early post-operative period (5) and were therefore excluded from this study. When excluding the patients with severe PPM from the analysis, moderate PPM remained significantly associated with increased mortality (age-adjusted HR: 1.17; 95% CI: 1.01 to 1.37, p = 0.04; HR adjusted for other risk factors and for propensity score: 1.18; 95% CI: 1.01 to 1.37, p = 0.03).


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
One important finding of this study is that severe PPM is an independent predictor of late mortality in patients undergoing AVR. The results of this study also confirm previous data (5,23,24) showing that even a moderate PPM has a detrimental impact on post-operative survival in the context of a depressed LV function. Moreover, the results of this study show that the impact of PPM on late survival differs markedly depending on age and BMI of the patients. These new findings emphasize the importance of tailoring the PPM preventive strategy to the baseline characteristics of the patient.

Comparison with previous studies.   The results of the present study are consistent with those from several previous studies showing that PPM, and especially severe PPM, significantly affects late survival (3,4,6,25,26). On the other hand, other studies reported no significant association between PPM and survival (8–12). The discrepancies among the previous studies may be, at least in part, due to the fact that some of these studies (8–10) have identified PPM with the use of the geometric orifice area or the in vitro EOA provided by the manufacturers, instead of the in vivo EOA (27). In this regard, previous studies demonstrated that the indexed geometric orifice area or the indexed EOA derived from manufacturers' in vitro data have little or no sensitivity to detect PPM (13,22). Differences in age distribution, prevalence of obesity, and prevalence of moderate versus severe PPM in the patient populations may also help explain the discrepancies observed among previous studies. To this effect, studies conducted in younger patient populations (3,25) generally found that PPM has a significant impact on late survival; studies in elderly populations (11,12) often failed to demonstrate any significant association.

Interaction between PPM and age.   The results of this study reveal that severe PPM has a significant negative effect on late survival in patients <70 years old, but not in the elderly population. These results are consistent with those of Moon et al. (7), suggesting that the impact of PPM on post-operative outcomes is more pronounced in young patients than in older ones. This finding might be related to the fact that younger patients have higher cardiac output requirements. They indeed have higher basal metabolic rates and are generally more physically active. Also, because they have a longer life expectancy, younger patients are exposed to the risk of PPM for a longer period of time.

A possible explanation for the late effect of PPM on survival could be that patients with PPM undergoing long-term bioprosthetic valve degeneration or development of pannus have less EOA "reserve" and will therefore develop severe stenosis of their valves more rapidly than patients without PPM undergoing the same processes. This additive effect of PPM and acquired prosthesis dysfunction may likely be more important in younger patients given that they are at higher risk for rapid calcific degeneration of their bioprosthetic valve. Also, older patients might be more likely to die from other causes before this process has any impact. These hypothetical mechanisms, however, remain to be confirmed by further studies.

Interaction between PPM and obesity.   An important finding of this study is that the PPM has an important negative impact on survival in patients with a BMI <30 kg/m2, but no significant impact in obese patients. This finding is most likely related to the fact that the use of the body surface area for normalization of EOA may overestimate the prevalence and severity of PPM in obese patients. Future studies will be necessary to determine if the indexation of EOA can be improved or refined in the case of obese patients. In this regard, the investigators of the Strong Heart Study reported that fat-free mass, which represents the metabolically active tissues, accounts for 20% to 40% of the weight difference between lean and obese individuals of the same height (28). They also demonstrated that stroke volume and cardiac output are more strongly related to fat-free mass than to adipose mass or other anthropometric measures. Hence, a potentially interesting avenue would be to index the EOA for the fat-free mass since this parameter appears to be the main determinant of cardiac output in normal-weight, overweight, and obese people.

Interaction between PPM and LV function.   From the standpoint of pathophysiology, it is logical to consider that patients with reduced ventricular reserve are more vulnerable to the residual afterload excess imposed by PPM on the LV. Previous studies from this laboratory (5) have shown increased early mortality in patients with a combination of moderate PPM and LV dysfunction as well as in all patients with severe PPM, irrespective of LV function. Mortality also tended to be increased in patients with moderate PPM without LV dysfunction, but this result was not statistically significant (5). Studies from other laboratories (23,24) also demonstrated that the impact of moderate PPM on mid-term mortality is more important in patients with pre-existing LV dysfunction than in those with preserved LV function. The question that we aimed to answer in the context of the present study was as follows: could there be a natural selection process in the sense that patients with severe PPM having survived operation could have a relatively good long-term prognosis? Or on the other hand, do they continue to have a worse prognosis? The results of this study, in fact, reveal that patients with moderate PPM and preserved pre-operative LV systolic function continue to have a good prognosis, similar to that in patients without PPM; those with moderate or severe PPM and LV dysfunction continue to have worse prognoses in the long term. Moreover, the present study shows that severe PPM is also associated with increased late mortality independently of LV function, but only in patients <70 years old and/or with a BMI <30 kg/m2. The latter result may suggest that PPM has less impact in older patients and/or obese patients because of lesser cardiac output requirements in relation to body size. On the other hand, it should not be interpreted that the same is necessarily true with regard to early mortality since it may well be that older and/or obese patients are at a higher risk of early mortality, but having survived, would indeed have a relatively good prognosis because of lesser cardiac output requirements. Further studies will be necessary to elucidate this point.

Clinical implications.   As opposed to the other risk factors for operative mortality after AVR, PPM can be avoided or its severity can be reduced, with the use of a preventive strategy at the time of operation (13,18,29–31). Alternate surgical procedures that may be considered to prevent PPM include: insertion of a prosthesis with a better hemodynamic performance, such as a stentless bioprosthesis or a new generation of stented bioprosthesis or bileaflet mechanical valve implanted in the supra-annular position; and aortic root enlargement to accommodate a larger size of the same prosthesis model. This latter procedure should logically be considered only in patients in whom occurrence of PPM, and particularly severe PPM, cannot be avoided with the use of a better performing prosthesis and in whom the risk-benefit ratio of doing such a procedure is considered acceptable.

The present results corroborate previous recommendations with regard to the prevention of PPM (16), that is, that it should ideally be avoided in all patients with LV dysfunction and that severe PPM should be considered as carrying a poor prognosis regardless of LV function. On the other hand, it provides additional evidence that moderate PPM is well tolerated in patients without LV dysfunction.

As for the influence of age and/or BMI in patients with anticipated severe PPM, the results should be considered, at this time, as providing additional information and might become useful in the clinical decision-making process in the individual patient. Indeed, it has become apparent that when considering AVR, the projected indexed EOA of the prosthesis to be implanted should be routinely calculated, and if PPM is projected, the information should be interpreted in light of the patient's clinical status including age, lifestyle, BMI, LV function, presence of severe LV hypertrophy, and others, as well as the risk-benefit ratio of doing an alternate surgical procedure. In this sense, the present results provide additional information, but given the deleterious effect of severe PPM on early mortality, even in patients with preserved LV function, it remains to be determined if projected severe PPM could possibly become acceptable in an elderly patient with a combination of normal LV function, limited physical activity, and other factors significantly increasing the risk of performing an alternate surgical procedure. Likewise, it remains to be determined if BMI has a similar impact on early mortality.

Study limitations.   The study is retrospective in design, so patient characteristics in the 3 PPM groups were intrinsically different. Propensity score adjustment was used to reduce selection bias. Nonetheless, it is always possible that a selection bias or unidentified confounders might have influenced the results. On the other hand, one could argue that PPM is, among all the other pre-operative or operative factors, the only one that can be easily modified at the time of operation.

In the present study, PPM was identified with the use of the projected indexed EOA. Previous studies demonstrated that this parameter correlates well with the post-operative indexed EOA measured by Doppler-echocardiography and that it provides good sensitivity and specificity for the prediction of PPM (13,22). However, owing to various post-operative factors including low or high flow state conditions, development of prosthesis dysfunction after implantation, and measurement errors, the post-operative EOA may be substantially different from the projected EOA in some patients. Nonetheless, in the subset of 496 patients in whom Doppler-echocardiographic exam was performed 1 month after operation, the measured indexed EOAs were very similar to the projected indexed EOAs in the same groups, so it is very unlikely that this limitation would have significantly influenced the overall results.

Beyond the prolongation of life, the improvement of a patient's quality of life is also an important objective of AVR. This aspect was not addressed in the present study. Nonetheless, previous studies have reported that moderate/severe PPM is a powerful independent predictor of post-operative functional class (32) and maximum exercise capacity (33). Hence, the results of this study on the impact of PPM on late survival cannot be generalized to other post-operative outcomes such as functional outcome and early mortality.


    Conclusions
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
The present study analyzed the potential effects of moderate and severe PPM on late mortality in patients having survived AVR. Results suggest that moderate PPM is associated with increased late mortality in the patients with LV dysfunction, but with normal prognosis in those with preserved LV function. Notwithstanding the previously demonstrated strong deleterious influence of severe PPM on operative mortality even if LV function is preserved, this factor appears to increase late mortality only in patients <70 years old and/or with a BMI <30 kg/m2 or an LVEF <50%. Further studies are necessary to confirm the relevance of this observation with regard to the clinical decision-making process.


    Acknowledgments
 
The authors thank Paul Cartier, MD (who died during the course of this study), Richard Baillot, MD, Richard Bauset, MD, Éric Charbonneau, MD, Denis Desaulniers, MD, Éric Dumont, MD, Michel Lemieux, MD, Jacques Métras, MD, Jean Perron, MD, and Gilles Raymond, MD, for implanting the prostheses and participating in the study. They also thank Brigitte Dionne, Stéphanie Dionne, and Martine Fleury for data collection and validation of clinical data and Serge Simard, MS, and Julien Magne, BSc, for their support in the statistical analyses.


    Footnotes
 
This work was supported in part by a grant from the Canadian Institutes of Health Research (MOP 57745), Ottawa, Ontario, Canada. Dr. Pibarot holds the Canada Research Chair in Valvular Heart Diseases, Canadian Institutes of Health Research, Ottawa, Ontario, Canada. Dr. Mathieu is a research scholar from the Fonds de Recherche en Santé du Québec, Montreal, Québec, Canada.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
1. Rahimtoola SH. The problem of valve prosthesis-patient mismatch Circulation 1978;58:20-24.[Abstract/Free Full Text]

2. Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography J Am Coll Cardiol 1990;16:637-643.[Abstract]

3. Mohty D, Malouf JF, Girard SE, et al. Impact of prosthesis-patient mismatch on long-term survival in patients with small St. Jude medical mechanical prostheses in the aortic position. Circulation 2006;113:420-426.[Abstract/Free Full Text]

4. Tasca G, Mhagna Z, Perotti S, et al. Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis Circulation 2006;113:570-576.[Abstract/Free Full Text]

5. Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of prosthesis-patient mismatch on short-term mortality after aortic valve replacement Circulation 2003;108:983-988.[Abstract/Free Full Text]

6. Walther T, Rastan A, Falk V, et al. Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement Eur J Cardiothorac Surg 2006;30:15-19.[Free Full Text]

7. Moon MR, Pasque MK, Munfakh NA, et al. Prosthesis-patient mismatch after aortic valve replacement: impact of age and body size on late survival Ann Thorac Surg 2006;81:481-488.[Abstract/Free Full Text]

8. Blackstone EH, Cosgrove DM, Jamieson WR, et al. Prosthesis size and long-term survival after aortic valve replacement J Thorac Cardiovasc Surg 2003;126:783-793.[Abstract/Free Full Text]

9. Howell NJ, Keogh BE, Barnet V, et al. Patient-prosthesis mismatch does not affect survival following aortic valve replacement Eur J Cardiothorac Surg 2006;30:10-14.[Free Full Text]

10. Koch CG, Khandwala F, Estafanous FG, Loop FD, Blackstone EH. Impact of prosthesis-patient size on functional recovery after aortic valve replacement Circulation 2005;111:3221-3229.[Abstract/Free Full Text]

11. Flameng W, Meuris B, Herijgers P, Herregods MC. Prosthesis-patient mismatch is not clinically relevant in aortic valve replacement using the Carpentier-Edwards Perimount valve Ann Thorac Surg 2006;82:530-536.[Abstract/Free Full Text]

12. Monin JL, Monchi M, Kirsch ME, et al. Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival Eur Heart J 2007;28:2620-2626.[Abstract/Free Full Text]

13. Bleiziffer S, Eichinger WB, Hettich I, et al. Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart 2007;93:615-620.[Abstract/Free Full Text]

14. Pibarot P, Dumesnil JG. Prevention of valve prosthesis-patient mismatch before aortic valve replacement: does it matter and is it feasible? Heart 2007;93:549-551.[Abstract/Free Full Text]

15. Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention J Am Coll Cardiol 2000;36:1131-1141.[Abstract/Free Full Text]

16. Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention Heart 2006;92:1022-1029.[Abstract/Free Full Text]

17. Botzenhardt F, Eichinger WB, Guenzinger R, et al. Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular Perimount Magna bioprosthesis in the aortic position Thorac Cardiovasc Surg 2005;53:226-230.[CrossRef][Medline]

18. Dalmau MJ, Gonzalez-Santos JM, Lopez-Rodriguez J, Bueno M, Arribas A, Nieto F. One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized study ICVTS 2007;6:345-349.

19. Garcia-Bengochea J, Sierra J, Gonzalez-Juanatey JR, et al. Left ventricular mass regression after aortic valve replacement with the new Mitroflow 12A pericardial bioprosthesis J Heart Valve Dis 2006;15:446-451.[Web of Science][Medline]

20. Chambers JB, Rimington HM, Rajani R, Hodson F, Shabbo F. A randomized comparison of the Cryolife O'Brien and Toronto stentless replacement aortic valves J Thorac Cardiovasc Surg 2007;133:1045-1050.[Abstract/Free Full Text]

21. Koertke H, Seifert D, Drewek-Platena S, Koerfer R. Hemodynamic performance of the Medtronic ADVANTAGE prosthetic heart valve in the aortic position: echocardiographic evaluation at one year J Heart Valve Dis 2003;12:348-353.[Medline]

22. Pibarot P, Dumesnil JG, Cartier PC, Métras J, Lemieux M. Patient-prosthesis mismatch can be predicted at the time of operation Ann Thorac Surg 2001;71:S265-S268.[CrossRef][Web of Science][Medline]

23. Ruel M, Al-Faleh H, Kulik A, Chan K, Mesana TG, Burwash IG. Prosthesis-patient mismatch after aortic valve replacement primarily affects patients with pre-existing left ventricular dysfunction: impact on survival, freedom from heart failure, and left ventricular mass regression J Thorac Cardiovasc Surg 2006;131:1036-1044.[Abstract/Free Full Text]

24. Kulik A, Burwash IG, Kapila V, Mesana TG, Ruel M. Long-term outcomes after valve replacement for low-gradient aortic stenosis: Impact of prosthesis-patient mismatch Circulation 2006;114:I5553-I5558.

25. Kohsaka S, Mohan S, Virani S, et al. Prosthesis-patient mismatch affects long-term survival after mechanical valve replacement J Thorac Cardiovasc Surg 2008;135:1076-1080.[Abstract/Free Full Text]

26. Florath I, Albert A, Rosendahl U, Ennker IC, Ennker J. Impact of valve prosthesis-patient mismatch estimated by echocardiographic-determined effective orifice area on long-term outcome after aortic valve replacement Am Heart J 2008;155:1135-1142.[CrossRef][Web of Science][Medline]

27. Dumesnil JG, Pibarot P. Prosthesis-patient mismatch and clinical outcomes: The evidence continues to accumulate J Thorac Cardiovasc Surg 2006;131:952-955.[Free Full Text]

28. Collis T, Devereux RB, Roman MJ, et al. Relations of stroke volume and cardiac output to body composition. The Strong Heart Study. Circulation 2001;103:820-825.[Abstract/Free Full Text]

29. Castro LJ, Arcidi JMJ, Fisher AL, Gaudiani VA. Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch Ann Thorac Surg 2002;74:31-36.[Abstract/Free Full Text]

30. Walther T, Lehmann S, Falk V, et al. Prospectively randomized evaluation of stented xenograft hemodynamic function in the aortic position Circulation 2004;110:II74-II78.[Medline]

31. Dhareshwar J, Sundt III TM, Dearani JA, Schaff HV, Cook DJ, Orszulak TA. Aortic root enlargement: what are the operative risks? J Thorac Cardiovasc Surg 2007;134:916-924.[Abstract/Free Full Text]

32. Ruel M, Rubens FD, Masters RG, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves J Thorac Cardiovasc Surg 2004;127:149-159.[Abstract/Free Full Text]

33. Bleiziffer S, Eichinger WB, Hettich I, et al. Impact of prosthesis-patient mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement Heart 2007;94:637-641.[Medline]


Related Article

Inside This Issue of JACC
J. Am. Coll. Cardiol. 2009 53: A26. [Full Text] [PDF]



This article has been cited by other articles:


Home page
Circ Cardiovasc ImagingHome page
E. Angeloni, G. Melina, P. Pibarot, U. Benedetto, S. Refice, G. M. Ciavarella, A. Roscitano, R. Sinatra, and J. R. Pepper
Impact of Prosthesis-Patient Mismatch on the Regression of Secondary Mitral Regurgitation After Isolated Aortic Valve Replacement With a Bioprosthetic Valve in Patients With Severe Aortic Stenosis
Circ Cardiovasc Imaging, January 1, 2012; 5(1): 36 - 42.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R. Rosenhek
Almanac 2011: valvular heart disease. The national society journals present selected research that has driven recent advances in clinical cardiology
Heart, December 15, 2011; 97(24): 2007 - 2017.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Ewe, M. Muratori, V. Delgado, M. Pepi, G. Tamborini, L. Fusini, R. J. M. Klautz, P. Gripari, J. J. Bax, M. Fusari, et al.
Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
J. Am. Coll. Cardiol., October 25, 2011; 58(18): 1910 - 1918.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
M.-A. Clavel, J. Rodes-Cabau, E. Dumont, R. Bagur, S. Bergeron, R. De Larochelliere, D. Doyle, E. Larose, J. G. Dumesnil, and P. Pibarot
Validation and Characterization of Transcatheter Aortic Valve Effective Orifice Area Measured by Doppler Echocardiography
J. Am. Coll. Cardiol. Img., October 1, 2011; 4(10): 1053 - 1062.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
W. J. Stewart and L. L. Rodriguez
Avoiding Patient-Prosthesis Mismatch: Is TAVI a New Solution?
J. Am. Coll. Cardiol. Img., October 1, 2011; 4(10): 1063 - 1066.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. L. Brown, H. V. Schaff, R. M. Suri, Z. Li, T. M. Sundt, J. A. Dearani, and M. Enriquez-Sarano
Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size
J. Thorac. Cardiovasc. Surg., August 1, 2011; 142(2): e5 - e9.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
G. F. Coutinho, P. M. Correia, G. Pauperio, F. de Oliveira, and M. J. Antunes
Aortic root enlargement does not increase the surgical risk and short-term patient outcome?
Eur J Cardiothorac Surg, August 1, 2011; 40(2): 441 - 447.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
W. Y. Shi, C.-H. Yap, P. A. Hayward, D. T. Dinh, C. M. Reid, G. C. Shardey, and J. A. Smith
Impact of prosthesis-patient mismatch after mitral valve replacement: a multicentre analysis of early outcomes and mid-term survival
Heart, July 1, 2011; 97(13): 1074 - 1081.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. H. Adams, J. Chikwe, F. Filsoufi, and A. C. Anyanwu
The Year in Cardiovascular Surgery
J. Am. Coll. Cardiol., March 29, 2011; 57(13): 1425 - 1444.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. A. Cotoni, R. T. Palac, L. J. Dacey, and D. J. O'Rourke
Defining Patient-Prosthesis Mismatch and Its Effect on Survival in Patients With Impaired Ejection Fraction
Ann. Thorac. Surg., March 1, 2011; 91(3): 692 - 699.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Garatti, F. Mori, F. Innocente, A. Canziani, P. Gagliardotto, E. Mossuto, T. Santoro, V. Montericcio, A. Frigiola, and L. Menicanti
Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient-Prosthesis Mismatch a Relevant Phenomenon?
Ann. Thorac. Surg., January 1, 2011; 91(1): 71 - 77.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
H. Okamura, A. Yamaguchi, K. Noguchi, K. Naito, K. Yuri, and H. Adachi
Hemodynamics and Outcomes of Aortic Valve Replacement with a 17- or 19-mm Valve
Asian Cardiovasc Thorac Ann, October 1, 2010; 18(5): 450 - 455.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
V. Chan, A. Kulik, A. Tran, P. Hendry, R. Masters, T. G. Mesana, and M. Ruel
Long-Term Clinical and Hemodynamic Performance of the Hancock II Versus the Perimount Aortic Bioprostheses
Circulation, September 14, 2010; 122(11_suppl_1): S10 - S16.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
T. R. Wyss, M. Bigler, M. Stalder, L. Englberger, T. Aymard, A. Kadner, and T. P. Carrel
Absence of prosthesis-patient mismatch with the new generation of Edwards stented aortic bioprosthesis
Interact CardioVasc Thorac Surg, June 1, 2010; 10(6): 884 - 888.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. Bleiziffer, A. Ali, I. M. Hettich, D. Akdere, R. P. Laubender, D. Ruzicka, J. Boehm, R. Lange, and W. Eichinger
Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement
Heart, June 1, 2010; 96(11): 865 - 871.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. Flameng, M. C. Herregods, M. Vercalsteren, P. Herijgers, K. Bogaerts, and B. Meuris
Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves
Circulation, May 18, 2010; 121(19): 2123 - 2129.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Toole, M. R. Stroud, J. M. Kratz, A. J. Crumbley III, S. M. Bradley, F. A. Crawford Jr, and J. S. Ikonomidis
Twenty-Five Year Experience With the St. Jude Medical Mechanical Valve Prosthesis
Ann. Thorac. Surg., May 1, 2010; 89(5): 1402 - 1409.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
K. Takeda, G. Matsumiya, T. Sakaguchi, S. Miyagawa, T. Yamauchi, Y. Shudo, H. Izutani, and Y. Sawa
Impact of untreated mild-to-moderate mitral regurgitation at the time of isolated aortic valve replacement on late adverse outcomes
Eur J Cardiothorac Surg, May 1, 2010; 37(5): 1033 - 1038.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Rahimtoola
The Year in Valvular Heart Disease
J. Am. Coll. Cardiol., April 20, 2010; 55(16): 1729 - 1742.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
D. S. Bach
Echo/Doppler Evaluation of Hemodynamics After Aortic Valve Replacement: Principles of Interrogation and Evaluation of High Gradients
J. Am. Coll. Cardiol. Img., March 1, 2010; 3(3): 296 - 304.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W.R. E. Jamieson, J. Ye, J. Higgins, A. Cheung, G. J. Fradet, P. Skarsgard, E. Germann, F. Chan, and S. V. Lichtenstein
Effect of Prosthesis-Patient Mismatch on Long-Term Survival With Aortic Valve Replacement: Assessment to 15 Years
Ann. Thorac. Surg., January 1, 2010; 89(1): 51 - 59.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. J. Howell, B. E. Keogh, D. Ray, R. S. Bonser, T. R. Graham, J. Mascaro, S. J. Rooney, I. C. Wilson, and D. Pagano
Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival
Ann. Thorac. Surg., January 1, 2010; 89(1): 60 - 64.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
S. Nozohoor, J. Nilsson, C. Luhrs, A. Roijer, and J. Sjogren
Influence of prosthesis-patient mismatch on left ventricular remodelling in severe aortic insufficiency
Eur J Cardiothorac Surg, January 1, 2010; 37(1): 133 - 138.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Salizzoni
Quality of life in patients with prosthesis-patient mismatch
J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 786 - 787.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M.-A. Clavel, J. G. Webb, P. Pibarot, L. Altwegg, E. Dumont, C. Thompson, R. De Larochelliere, D. Doyle, J.-B. Masson, S. Bergeron, et al.
Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis
J. Am. Coll. Cardiol., May 19, 2009; 53(20): 1883 - 1891.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow View Related Cardiosource Journal Scan
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mohty, D.
Right arrow Articles by Pibarot, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mohty, D.
Right arrow Articles by Pibarot, P.
Related Collections
Right arrowRelated Article

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement