Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2007; 50:875-876, doi:10.1016/j.jacc.2007.04.078 (Published online 10 August 2007).
© 2007 by the American College of Cardiology Foundation
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2007.04.078v1
50/9/875    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lindsay, B. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lindsay, B. D.

EDITORIAL COMMENT

Is Pulmonary Vein Antrum Isolation a Critical Determinant of Recurrent Arrhythmias After Ablation of Atrial Fibrillation?*

Bruce D. Lindsay, MD, FACC1,*

Cardiology Division, Washington University School of Medicine, St. Louis, Missouri.

* Reprint requests and correspondence: Dr. Bruce D. Lindsay, Director, Clinical Electrophysiology, Washington University School of Medicine, St. Louis, Missouri 63110. (Email: blindsay{at}im.wustl.edu).


In this issue of the Journal, Di Biase et al. (1) reported their initial experience with remote magnetic navigation of a 4-mm-tip catheter for ablation of atrial fibrillation (AF). Their results confirm that the catheter navigated to targets and reduced fluoroscopy; however, the procedure time was not improved and the 4-mm-tip catheter was ineffective and prone to charring. This is why most groups have abandoned 4-mm-tip catheters for ablation of AF. Experience with remote navigation is required to assess tissue contact, but the incidence of charring reported by Di Biase et al. (1) suggests that poor contact did not account for failed pulmonary vein antrum isolation (PVAI). Their observations are consistent with the experience at Washington University, which has been involved with the development of this technology from its inception (2–4). Specifically, we have found that the system meets expectations for navigation to left atrial targets as reported by Di Biase et al. (1) and Pappone et al. (5); however, I share the opinion that the 4-mm-tip catheter, which was designed for ablation of supraventricular tachycardia, should not be promoted for ablation of AF. An irrigated magnetic navigation catheter, which is under development, should improve delivery of energy and reduce or eliminate char formation.

This paper is unique because the authors prospectively tested the hypothesis that PVAI determines recurrence of AF. They reported 78% of patients were free of recurrence of AF when PVAI was achieved for all four pulmonary veins, whereas the success rate was only 10% when PVAI was incomplete despite wide circumferential ablation. This is concordant with other studies which have demonstrated that recovery of pulmonary vein conduction is associated with recurrence of atrial arrhythmias (6–9). These studies focused on patients with recurrent symptoms. An important question is how often does pulmonary vein conduction recover in patients without recurrence of atrial fibrillation? Cappato et al. (10) examined this in patients who had undergone a second electrophysiology study after segmental pulmonary vein isolation for paroxysmal or persistent AF. They found that recovery of conduction was associated with recurrence of AF, but a clinically successful outcome was achieved in 32% of patients despite late recurrence of conduction. In such patients, absence of symptomatic AF may have been related to ablation of triggers or slower conduction across the ablated segments that had recovered.

Methods for ablation of AF have evolved from elimination of triggers, to segmental pulmonary vein isolation, to wide circumferential ablation incorporating a larger mass of atrial tissue (11–13). The evolution of ablation techniques recognizes that triggered mechanisms alone may account for AF in some patients, but in most there is a need to modify the substrate that sustains AF. In this regard, there is not much difference between PVAI and wide circumferential ablation. Both approaches include the antrum and a large portion of the posterior wall of the left atrium. Ablation of complex fractionated electrograms is another method (14). Each approach substantially modifies the substrate that sustains AF. These methods are supported by investigations showing that the ability to sustain AF depends on left atrial mass and refractoriness (15), local atrial frequency (16–18), and wavebreak and re-entry on the posterior wall (19).

The effect of extensive wide circumferential ablation should be comparable to PVAI if meticulous care is taken to ablate all tissue within the circumferential lesions, because both methods encompass a similar mass of atrial tissue. It is certainly possible that during wide circumferential ablation either the pulmonary vein antrum would be isolated, or conduction through this zone would be altered so profoundly that atrial fibrillation could not be sustained. However, Hocini et al. (20) found that voltage reduction within wide circumferential ablation does not consistently predict isolation of the pulmonary veins. The central question is what end point should be used to judge the success of the procedure? Is voltage reduction without PVAI sufficient? The study by Di Biase et al. (1) demonstrates that when PVAI is the standard, complete isolation of the pulmonary vein antrum portends a modest risk of AF but that recurrence rates are very high when this end point is not achieved.


    Footnotes
 
* Editorials published in the Journal of the American College of Cardiology reflect the views of the authors and do not necessarily represent the views of JACC or the American College of Cardiology. Back

1 Dr. Lindsay is an unpaid consultant for Stereotaxis Inc. Back


    References
 Top
 References
 
1. Di Biase LD, Fahmy TS, Patel D, et al. Remote magnetic navigation: initial human experience in pulmonary vein ablation J Am Coll Cardiol 2007;50:868-874.[Abstract/Free Full Text]

2. Faddis MN, Blume W, Dehne J, et al. A novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation Circulation 2002;106:2980-2985.[Abstract/Free Full Text]

3. Faddis MN, Chen J, Osborne J, Talcott M, Lindsay B. Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans J Am Coll Cardiol 2003;42:1952-1959.[Abstract/Free Full Text]

4. Greenberg S, Blume W, Faddis M, et al. Remote controlled magnetically guided pulmonary vein isolation in canines Heart Rhythm 2006;3:71-76.[CrossRef][Web of Science][Medline]

5. Pappone C, Vicedomini G, Manguso F, et al. Robotic magnetic navigation for atrial fibrillation ablation J Am Coll Cardiol 2006;47:1390-1400.[Abstract/Free Full Text]

6. Oral H, Knight BP, Tada H, et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation Circulation 2002;105:1077-1081.[Abstract/Free Full Text]

7. Nanthakumar K, Plumb VJ, Epseitn AE, Veenhuyzen GD, Link D, Kay GN. Resumption of electrical conduction in previously isolated pulmonary vein Circulation 2004;109:1226-1229.[Abstract/Free Full Text]

8. Ouyan F, Ant M, Ernst S, et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veinsLessons from the double lasso technique. Circulation 2005;111:127-135.[Abstract/Free Full Text]

9. Nilsson B, Chen X, Pehson S, Kober L, Hilden J, Svendson JH. Recurrence of pulmonary vein conduction and atrial fibrillation after pulmonary vein isolation for atrial fibrillation; a randomized trial of the ostial versus the extraostial ablation strategy Am Heart J 2006;152:e1-e8.[CrossRef][Medline]

10. Cappato R, Negroni S, Pecora D, et al. Propective assessment of late conduction recurrence across radiofequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation Circulation 2003;108:1599-1604.[Abstract/Free Full Text]

11. Jais P, Haissaguerre M, Shah DC, et al. A focal source of atrial fibrillation treated by discrete radiofrequency ablation Circulation 1997;95:572-576.[Abstract/Free Full Text]

12. Haissaguerre M, Shah DC, Jais P, et al. Electrophysiological breakthroughs from the left atrium to the pulmonary veins Circulation 2000;102:2463-2465.[Abstract/Free Full Text]

13. Pappone C, Rosanio S, Oreto G, et al. Circumferential radiofrequency ablation of pulmonary vein ostia: a new anatomic approach for curing atrial fibrillation Circulation 2000;102:2619-2628.[Abstract/Free Full Text]

14. Nademanee K, McKenzie J, Kosar E, et al. A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate J Am Coll Cardiol 2004;43:2044-2053.[Abstract/Free Full Text]

15. Byrd GD, Prasad SM, Ripplinger CM, et al. Importance of geometry and refractory period in sustaining atrial fibrillation: testing the critical mass hypothesis Circulation 2005;112(Suppl 9)I17–3.

16. Mansour M, Mandapati R, Berenfeld O, Chen J, Samie FH, Jalife J. Left-to-right gradient of atrial frequencies during acute atrial fibrillation in the isolated sheep heart Circulation 2001;103:2631-2636.[Abstract/Free Full Text]

17. Lazar S, Dixit S, Marchlinski FE, Callans DJ, Gerstenfeld EP. Presence of left-to-right atrial frequency gradient in paroxysmal but not persistent atrial fibrillation in humans Circulation 2004;110:3181-3186.[Abstract/Free Full Text]

18. Sanders P, Berenfeld O, Hocini M, et al. Spectral analysis identifies sites of high frequency activity maintaining atrial fibrillation in humans Circulation 2005;112:789-797.[Abstract/Free Full Text]

19. Kalifa J, Tanaka K, Zaitsev AV, et al. Mechanisms of wave fractionation at boundaries of high-frequency excitation in the posterior left atrium of the isolated sheep heart during atrial fibrillation Circulation 2006;113:626-633.[Abstract/Free Full Text]

20. Hocini M, Sanders P, Jais P, et al. Prevalence of pulmonary vein disconnection after anatomical ablation for atrial fibrillation; consequences of wide atrial encircling of the pulmonary veins. Eur Heart J 1005;26:696–704.




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
L. Di Biase, J. D. Burkhardt, R. A. Schweikert, W. I. Saliba, and A. Natale
Reply
J. Am. Coll. Cardiol., April 22, 2008; 51(16): 1615 - 1616.
[Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2007.04.078v1
50/9/875    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lindsay, B. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lindsay, B. D.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement