cardiology careers collections past issues search home
     

Right arrow Help viewing high resolution images
Right arrow Return to article

Please click here to obtain permission to reproduce this image.

Click on image to view larger version.


Figure 2


Figure 2 ROC Curves Showing the Ability of VE/VCO2 Slope to Predict Overall Mortality, SCD, and Pump Failure Death

For panel A overall mortality: area under the curve 0.74, p < 0.001, 95% CI 0.61 to 0.81, optimal threshold ≤/>37.0, sensitivity 75, specificity 62. For panel B SCD: area under the curve 0.74, p = 0.002, 95% CI 0.61 to 0.81, optimal threshold ≤/>39.2, sensitivity 81, specificity 53. For panel C cardiac pump failure: area under the curve 0.69, p = 0.01, 95% CI 0.61 to 0.81, optimal threshold ≤/>37.0, sensitivity 72, specificity 65. VE/VCO2 = ventilation/carbon dioxide production; other abbreviations as in Figure 1.





Right arrow Return to article

 
  cardiology careers collections past issues search home