Background: Myocardial ischemia-reperfusion causes endothelial injury entirely in the vasculature of the infarct-related coronary artery. Sirolimus-eluting stent implantation inhibits re-endothelialization at the site of stenting.
Methods: This study included 29 patients with a first AMI due to occlusion of the left anterior descending coronary artery (LAD) and successful reperfusion therapy using a SES (n = 13) or bare-metal stent (BMS) (n = 16). The diameter of the epicardial segment distal to the site of SES deployment and coronary blood flow in the LAD in response to an intracoronary infusion of acetylcholine were measured at 2 weeks after AMI. Levels of vascular endothelial growth factor (VEGF) were measured by enzyme-linked immunoadsorbent assay in plasma obtained from the aortic root (AO) and the anterior interventricular vein (AIV) in all patients.
Results: The epicardial coronary artery was more severely constricted in response to acetylcholine in the SES than in the BMS group. The increase in coronary blood flow in response to acetylcholine was lower in the SES than in the BMS group. Vascular endothelial growth factor levels in the AIV were significantly lower than in the AO in the SES group but not in the BMS group.
Conclusions: During the course of AMI, SES implantation adversely affects endothelium-dependent vasomotor function in resistance and epicardial coronary arteries after the ischemia-reperfusion in association with a reduction in myocardial VEGF secretion.
| ||||||||||||
Drug-eluting stents (DES) in percutaneous coronary intervention remarkably reduce restenosis and revascularization rate in comparison with a bare-metal stent (BMS) (6). However, endothelial dysfunction at the peri-DES coronary segments can cause spasm in the stented coronary arteries after implantation of DES (7,8). It has been shown that sirolimus is capable of reducing expression of VEGF in vascular cells and VEGF-induced endothelial proliferation (9). Thus, we examined our hypothesis that diffusion of sirolimus into coronary blood flowing through a stent may directly or indirectly impair the recovery of reperfusion-induced endothelial injury entirely in the infarct-related coronary artery beyond the distal edge of the SES early after AMI.
| Methods |
|---|
|
|
|---|
30 min, ST-segment elevation of >0.2 mV in
2 contiguous leads on the standard 12-lead electrocardiogram, and elevation of serum creatine kinase levels to more than twice the upper limit of normal. All of the study patients received emergent coronary angiography and successful reperfusion therapy by primary percutaneous coronary intervention using sirolimus-eluting stents (SES) (n = 13) or BMS (n = 16) after ballooning coronary angioplasty. Because SES did not become available in Japan until August 2004, all patients treated before this date received BMS. Because clopidogrel was not available until May 2006 in Japan, SES was used only in patients who were confirmed to have no side effects from the previous use of ticlopidine, and BMS was used in the remaining patients. The exclusion criteria were as follows: 1) residual organic stenosis
30% in the LAD; 2) previous percutaneous coronary intervention in the LAD; 3) percutaneous coronary intervention at multiple segments of the LAD; 4) previous coronary artery bypass surgery; 5) congestive heart failure at 1 week after AMI; 6) persistent atrial fibrillation or a paced rhythm; 7) presence of collaterals to the LAD with Rentrop grade
2 at the emergent coronary angiography; 8) coronary artery spasm in the LAD (
40% decrease in coronary epicardial diameter from baseline) in response to the intracoronary infusion of acetylcholine (ACh) (10); and 9) valvular heart diseases, secondary hypertension, stroke, renal dysfunction (serum creatinine concentration >2.0 mg/dl), or other serious diseases. This study also included 12 control subjects who were selected from 57 consecutive subjects with normal coronary angiograms and left ventriculograms to match the age, gender, and other traditional risk factors of the AMI patients. These control subjects served as a reference group for the coronary vasomotor response and the plasma VEGF concentrations. The clinical characteristics of the patients with AMI and the control subjects are shown in Table 1. Written informed consent was obtained from all patients and control subjects before the study. The study was in agreement with the guidelines approved by the ethics committee at Yamanashi University Hospital.
|
Protocol for measurements of coronary vasomotor responses. After the blood sampling, a quantitative coronary angiographic study was performed in all of the AMI patients and the control subjects as in our previous report (10). After baseline angiography, incremental doses of ACh (5, 10, and 50 µg/min) were infused directly into the left coronary artery through the Judkins catheter. After an additional 15 min, intracoronary sodium nitroprusside (10 µg/min) was infused in the same manner as ACh. After another 15 min, intracoronary isosorbide dinitrate (1 mg) was administered. Coronary angiography was repeated before and during each infusion.
Quantitative coronary angiography and coronary blood flow measurement. Luminal diameter at the segment between 15 and 25 mm distal to the stent edge in the LAD and at the proximal segment with no previous percutaneous coronary intervention in left circumflex artery (LCx) as a reference was measured quantitatively (Cardio 500, Kontron Instruments, Munich, Germany) (10). Luminal diameter at the midsegment of the LAD was measured in all of the control subjects in the same manner as in the AMI patients.
Blood flow velocity was measured using a 0.014-inch wire equipped with a Doppler crystal at its tip (FloWire, Cardiometrics, Mountain View, California). The wire was carefully positioned in a segment of the LAD 5 to 15 mm from distal edge of the stent (10). Coronary blood flow (ml/min) was estimated from coronary blood flow velocity (Flow Map, Cardiometrics), as described previously (10).
Responses of the coronary artery diameter and coronary blood flow to infusions of ACh, nitrates, and sodium nitroprusside were expressed as percent changes from baseline values taken just before each infusion.
Statistical analysis. Data are expressed as the mean ± standard deviation or percentage. The frequencies between 2 groups of patients and the 2 mean values were compared using chi-square test and Student paired or unpaired t test, respectively. When more than 2 groups were compared, a 1-way analysis of variance was performed followed by a Sheffe test for post-hoc comparison of group means. The mean values of coronary vasomotor responses between the 2 patient groups were compared using 2-way analysis of variance for repeated measures followed by post-hoc testing with a Sheffe test. When frequencies among the patients with SES, those with BMS, and control subjects were compared, chi-square test using a 2 x 3 contingency table was initially examined for independence of frequencies among the 3 groups. When significant in independence by chi-square test, wholly significant difference was calculated (Tukey test) between the 2 groups. A confidence level of p < 0.05 was considered statistically significant. Analyses were performed in part with StatView 5.0 (SAS Institute, Cary, North Carolina).
| Results |
|---|
|
|
|---|
|
|
|
|
| Discussion |
|---|
|
|
|---|
0.68 ng/ml [0.15
0.74 nmol/l]) were detected in both AIV and AO and that sirolimus was released from SES into coronary blood until at least 2 weeks after the SES implantation. These concentrations were 10
1,000-fold lower than the levels that inhibited endothelium-dependent relaxation in the animal experiments (12,13). However, it cannot be excluded that chronic exposure to sirolimus in the coronary circulation for 2 weeks might cause a considerable accumulation of this drug in the vascular bed distal to the site of SES implantation, leading to selective aggravation of endothelial vasomotor dysfunction in the infarct-related coronary artery. Furthermore, the present study demonstrated that there was a step down in VEGF levels from the AO to AIV in patients with SES implantation but not in those with BMS implantation. These findings suggest that SES implantation may decrease the release of VEGF from the myocardial region supplied by the LAD, which may play a possible role in endothelial vasomotor dysfunction in infarct-related coronary arteries treated with SES.
A limitation of the present study was that the stent type was not randomized, and a small number of patients were enrolled. The data are preliminary, and large randomized studies are required to confirm the present data.
| Conclusions |
|---|
|
|
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
N. Kukreja, Y. Onuma, H. Garcia-Garcia, J. Daemen, R. van Domburg, and P. W. Serruys Primary Percutaneous Coronary Intervention for Acute Myocardial Infarction: Long-Term Outcome After Bare Metal and Drug-Eluting Stent Implantation Circ Cardiovasc Intervent, October 1, 2008; 1(2): 103 - 110. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Pepine Provoked Coronary Spasm and Acute Coronary Syndromes J. Am. Coll. Cardiol., August 12, 2008; 52(7): 528 - 530. [Full Text] [PDF] |
||||
![]() |
S. R. Dixon, C. L. Grines, and W. W. O'Neill The year in interventional cardiology. J. Am. Coll. Cardiol., June 17, 2008; 51(24): 2355 - 2369. [Full Text] [PDF] |
||||
![]() |
A. Jabs, S. Gobel, P. Wenzel, A. L. Kleschyov, M. Hortmann, M. Oelze, A. Daiber, and T. Munzel Sirolimus-induced vascular dysfunction increased mitochondrial and nicotinamide adenosine dinucleotide phosphate oxidase-dependent superoxide production and decreased vascular nitric oxide formation. J. Am. Coll. Cardiol., June 3, 2008; 51(22): 2130 - 2138. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Nakazawa, Q. Cheng, X. Xu, A. V. Finn, F. D. Kolodgie, and R. Virmani Drug-eluting stent implantation may not affect vasomotor function in early phase. J. Am. Coll. Cardiol., March 18, 2008; 51(11): 1124 - 1125. [Full Text] [PDF] |
||||
![]() |
J.-e. Obata and K. Kugiyama Reply. J. Am. Coll. Cardiol., March 18, 2008; 51(11): 1125 - 1125. [Full Text] [PDF] |
||||
![]() |
J. W. Kim, S. Y. Suh, C. U. Choi, J. O. Na, E. J. Kim, S.-W. Rha, C. G. Park, H. S. Seo, and D. J. Oh Six-Month Comparison of Coronary Endothelial Dysfunction Associated With Sirolimus-Eluting Stent Versus Paclitaxel-Eluting Stent J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 65 - 71. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Kern Persistent Endothelial Dysfunction After Drug-Eluting Stents: Another Continuing Cost of Reducing Restenosis J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 72 - 73. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |