Advertisement







Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2007; 49:1634-1641, doi:10.1016/j.jacc.2006.12.041 (Published online 30 March 2007).
© 2007 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.12.041v1
49/15/1634    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kanj, M. H.
Right arrow Articles by Natale, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kanj, M. H.
Right arrow Articles by Natale, A.

CLINICAL RESEARCH: HEART RHYTHM DISORDER

Pulmonary Vein Antral Isolation Using an Open Irrigation Ablation Catheter for the Treatment of Atrial Fibrillation

A Randomized Pilot Study

Mohamed H. Kanj, MD*, Oussama Wazni, MD*, Tamer Fahmy, MD, PhD*, Sergio Thal, MD*, Dimpi Patel, MD*, Claude Elay, MD*, Luigi Di Biase, MD*,{dagger}, Mauricio Arruda, MD*, Walid Saliba, MD*, Robert A. Schweikert, MD*, Jennifer E. Cummings, MD*, J. David Burkhardt, MD*, David O. Martin, MD*, Gemma Pelargonio, MD{ddagger}, Antonio Dello Russo, MD{ddagger}, Michela Casella, MD{ddagger}, Pietro Santarelli, MD§, Domenico Potenza, MD||, Raffaele Fanelli, MD||, Raimondo Massaro, MD||, Giovanni Forleo, MD|| and Andrea Natale, MD*,*

* Cleveland Clinic, Cleveland, Ohio
{dagger} University of Insubria, Varese, Italy
{ddagger} Catholic University, Rome, Italy
§ Catholic University, Campobasso, Italy
|| Casa Sollievo Della Sofferenza, San Giovanni Rotondo, Italy.

Manuscript received August 29, 2006; revised manuscript received December 18, 2006, accepted December 19, 2006.

* Reprint requests and correspondence to: Dr. Andrea Natale, Section of Cardiac Electrophysiology and Pacing, Center for Atrial Fibrillation, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue F15, Cleveland, Ohio 44195. (Email: natalea{at}ccf.org).


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
Objectives: We sought to test how catheter ablation using an open irrigation catheter (OIC) compares with standard catheters for pulmonary vein antrum isolation.

Background: Open irrigation catheters have the advantage of delivering greater power without increasing the temperature of the catheter tip, which enables deeper and wider lesions without the formation of coagulum on catheters.

Methods: Catheter ablation was performed using an 8-mm catheter (8MC) or an OIC. Patients were randomized to 3 groups: 8MC; OIC-1, OIC with a higher peak power (50 W); and OIC-2, OIC with lower peak power (35 W).

Results: A total of 180 patients were randomized to the 3 treatment strategies. Isolation of pulmonary vein antra was achieved in all patients. The freedom from atrial fibrillation was significantly greater in the 8MC and OIC-1 groups compared with the OIC-2 group (78%, 82%, and 68%, respectively, p = 0.043). Fluoroscopy time was lower in OIC-1 compared with OIC-2 and 8MC (28 ± 1 min, 53 ± 2 min, and 46 ± 2 min, respectively, p = 0.001). The mean left atrium instrumentation time was lower in the OIC-1 compared with the OIC-2 and 8MC groups (59 ± 3 min, 90 ± 5 min, and 88 ± 4 min, respectively, p = 0.001). However, there was a greater incidence of "pops" in the OIC-1 (100%, 0%, 0%, p < 0.001) along with higher incidences of pericardial effusion (20%, 0%, 0%, p < 0.001) and gastrointestinal complaints (17% in OIC-1, 3% in 8MC, and 5% in OIC-2, p = 0.031).

Conclusions: Although there was a decrease in fluoroscopy and left atrium instrumentation time with the use of OIC at higher power, this setting was associated with increased cardiovascular and gastrointestinal complications.

Abbreviations and Acronyms
  AF = atrial fibrillation
  ET = esophageal temperature
  ICE = intracardiac echocardiography
  LA = left atrium
  OIC = open irrigation catheter
  PV = pulmonary vein
  PVAI = pulmonary vein antrum isolation
  RF = radiofrequency
  8MC = 8-mm catheter


Radiofrequency (RF) catheter ablation has emerged in the past several years as an effective and curative approach for patients with symptomatic atrial fibrillation (AF) that is refractory to medical therapy (1–3). However, with current technology, this procedure is complex and time consuming, requiring delivery of many ablation lesions in the left and right atria. Although this procedure traditionally has been performed using a 4- or 8-mm RF catheter, such a catheter has many limitations, including coagulum formation and insufficient power delivery in areas of low blood flow.

Open irrigation catheters (OICs), however, are less likely to encounter these limitations and have been shown to result in larger lesion size and volume compared with traditional RF catheters (4–8), in part because of the prevention of coagulum and char formation at the catheter-tissue interface, which in turn prevents elevation in impedance. Additionally, with greater irrigation rates, the effect of blood flow on power delivery becomes minimal, making the OIC effective in both low and high blood flow areas (9). There are multiple preset power and irrigation-rate settings that are being used with OIC. These settings were mostly formed on the basis of in vivo and in vitro animal studies, and none was evaluated specifically for pulmonary vein (PV) isolation. We hypothesized that an OIC is superior to an 8-mm catheter (8MC) to achieve pulmonary vein antrum isolation (PVAI) for catheter ablation of AF.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
This study was in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines. It was performed with the subjects’ written informed consent. The study protocol was approved by the institution board review committees in all centers involved.

Study population.   This was a multicenter study that enrolled patients referred for PVAI. Patients between the ages of 18 to 80 years with symptomatic AF who had failed at least one antiarrhythmic medication were enrolled in the trial. Patients with previous PVAI procedure or history of esophageal or swallowing disorder were excluded from the study. Patients were randomized using a computer-generated program to either a dual-sensor 8-mm tip Celsius DS (Biosense Webster, Diamond Bar, California), a 3.5-mm ThermoCool open-irrigation tip catheter (Biosense Webster) using a higher power (50 W) and higher irrigation flow rate (30 ml/min; OIC-1) or a 3.5-mm ThermoCool open irrigation tip catheter using a lower power (35 W) and lower irrigation flow rate (17 to 30 ml/min; OIC-2). Crossovers were permitted at the end of the procedure if electrical isolation of the PV antra could not be achieved using the assigned catheter.

PVAI procedure.   Four sheaths were placed: 1 in the right internal jugular vein, 1 in the left femoral vein, and 2 in the right femoral vein. A 20-polar catheter was placed from the right internal jugular vein into the coronary sinus with the 10 distal electrodes in the coronary sinus and 10 proximal electrodes positioned against the lateral wall of the right atrium. An Acunav intracardiac echocardiography (ICE) catheter (Siemens Acuson, Mountain View, California) was placed via the left femoral vein and was positioned in the right atrium. Via the right femoral vein, left atrial (LA) instrumentation was performed with double trans-septal puncture using ICE and fluoroscopic guidance. Systemic anticoagulation was initiated just before the first trans-septal puncture, using intravenous heparin with a target activated clotting time of approximately 400 s. A fixed-radius decapolar Biosense LASSO circular mapping catheter (Biosense Webster) was used for mapping the PV antra. Ablation along the PV antrum was performed until disappearance of local PV potential. The end point of the procedure was electrical isolation of all PV antra. Entry block generally was verified when no PV potentials could be recorded along the antrum or inside the PV by the circular mapping catheter. When present, electrical dissociation of the PV from the LA also was used to confirmed exit block. After isolation of all 4 PV antra, catheters were withdrawn to the right atrium. Potentials at the right atrium-superior vena cava junction were mapped and ablated if there was no phrenic nerve capture during high-output pacing from these sites. At the end of the procedure, systemic anticoagulation was discontinued and partially reversed with intravenous protamine before the removal of vascular sheaths.

Intraprocedure power titration.   In the OIC group, an esophageal temperature (ET) probe was inserted before the beginning of the procedure. In the power-control mode, RF power was initially set at either 30 W (OIC-1) or 10 W (OIC-2), with a maximum temperature limit of 45°C. Power was then titrated by a 5-W increase every few seconds up to a maximum of 50 W (OIC-1) or 35 W (OIC-2). The OIC was irrigated using heparinized saline infusion (2,000 IU/l) at a rate of 30 ml/min (OIC-1) or 17 to 30 ml/min (OIC-2) during RF delivery and at 2 ml/min when idle in both groups. In the OIC-2 group, the irrigation rate was increased from 17 to 30 ml once power delivery reached 30 W. The heparinized saline was infused using the Cool Flow pump (Biosense Webster). The power was titrated down when an elevation of ET occurred, and RF energy delivery was stopped if the ET reached 39°C or if the ET continued to increase despite down-titration of the RF generator power (Figs. 1A and 1B).


Figure 1
View larger version (19K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1 Power Titration in the 3 Catheter Groups

(A) Open irrigation catheter using higher power (50 W), (B) open irrigation catheter using lower power (35 W), and (C) 8-mm catheter groups. ET = esophageal temperature; ICE = intracardiac echocardiography.

 
In the 8MC group, the initial RF power was set at 30 W and a maximum temperature limit of 55°C using the temperature control mode. The power was titrated up by increments of 5 W every few seconds to a maximum of 70 W, while we searched for microbubble formation caused by the ICE. Upon the detection of microbubbles, the power was titrated down. If a sudden shower of microbubbles was observed, RF energy delivery was immediately turned off. Patients in the 8MC group had their ET monitored during the PVAI procedure. Additionally, RF generator power was titrated in a similar fashion compared with the OIC groups as we searched for microbubble formation by ICE (Fig. 1C).

Follow-up.   Oral anticoagulation therapy with warfarin was resumed on the evening of the procedure and was continued for at least 6 months. For some patients, warfarin was continued indefinitely, particularly for patients with risk factors who experienced recurrence of AF or if there was severe (~70%) PV stenosis demonstrated by cardiac computed tomography (CT) scan performed routinely at the 3-month follow-up evaluation after ablation. Antiarrhythmics, Singh Vaghan Williams classes IC and III (sotalol and dofetilide) were given and continued for a 2-month period. We used a 2-month blanking period in which episodes of AF within that time period were not considered procedure failures. Patients with recurrent AF during this 2-month period were offered electrical direct-current cardioversion. Patients with recurrent AF after the 2-month period were identified as procedural failure.

Patients were monitored with a 24-h ambulatory Holter recording before discharge. Upon discharge, an arrhythmia transmitter was used to monitor events during the first 6 months. During the monitoring period, patients were asked to transmit when they experienced symptoms as well as at weekly intervals, even if they were asymptomatic. Additional event recorder monitoring was obtained beyond the 6-month period to confirm freedom from AF. Additionally, information from implanted devices was used, when available, to document arrhythmia recurrence. Freedom from AF (procedural clinical success) was defined as absence of documented atrial arrhythmias off antiarrhythmics, excluding beta-blockers and calcium channel blockers.

Esophagoscopy.   Patients who developed new symptoms of odynophagia or dysphagia underwent a chest CT and if the scan was normal they underwent an esophago-gastro-duodenoscopy (EGD).

Study end point.   The primary end point of the study was freedom of atrial arrhythmias at 6 months. Secondary end points included: 1) Electrical isolation of all PV antra at the end of the procedure. 2) Fluoroscopy time, which was defined as the fluoroscopy time needed to perform the RF ablation portion of the procedure. This time excludes fluoroscopy time needed to perform the 2 trans-septal punctures. 3) Left atrial instrumentation time, defined as the total time during which there were catheters in the LA. 4) Duration of ablation along the esophagus, which was assessed and evaluated with ICE. 5) Complications, which could be in the form of cerebrovascular (thromboembolic or hemorrhagic), cardiovascular (cardiac perforation, tamponade), or gastrointestinal. 6) In patients who had their ET monitored, the maximum ET, incidences of ET elevation, postablation increase in ET and time needed for ET to return to within 1°C of baseline temperature were compared between the 3 groups.

Statistical analysis.   Statistical analysis was performed using SPSS for Windows Version 13.0 (SPSS Inc., Chicago, Illinois). Continuous variables were expressed as mean ± standard error of the mean. Continuous variables of the 3 groups were compared using analysis of variance. Differences between each 2 groups were compared using post-hoc Bonferroni analysis. Categorical variables were expressed as percentages and were compared with the chi-square test. Comparisons between 2 groups were made with the Fisher exact test. Correlation coefficients between ET and catheter/generator parameters were performed by using simple linear regression analysis. A p value of <0.05 was considered statistically significant.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
The study was performed at 4 centers. A total of 180 patients were randomized to this study: 59 in the 8MC group, 61 in the OIC-1 group, and 60 in the OIC-2 group. All patients were followed for a period of at least 6 months, with a mean follow-up of 9 months. There was no statistically significant difference in patient characteristics or antiarrhythmic drug use between these groups (Table 1). There were no incidences of crossover between the groups.


View this table:
[in this window]
[in a new window]

 
Table 1 Patient Characteristics
 
Study outcomes.   Procedural success, defined as PV antrum electrical isolation, was achieved in all of the patients at the end of the procedure using the assigned catheter. The freedom from AF or any other atrial arrhythmia at 6 months was significantly greater in the OIC-1 and 8MC groups compared with the OIC-2 group (78% in 8MC, 82% in OIC-1, and 68% in OIC-2 groups, respectively, p = 0.043) (Fig. 2).


Figure 2
View larger version (40K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2 Short- and Long-Term Procedural Success

Success was defined as (A) pulmonary vein antrum isolation and (B) freedom of any atrial arrhythmias at 6 months. 8MC = 8-mm catheter; OIC-1 = 3.5-mm open irrigation tip catheter using a higher power and higher irrigation flow rate; OIC-2 = 3.5-mm ThermoCool open irrigation tip catheter using a lower power and lower irrigation flow rate; PVAI = pulmonary vein antrum isolation.

 
Time intervals.   The mean fluoroscopy time required for PVAI was significantly lower in the OIC-1 group compared with OIC-2 and 8MC groups (28 ± 1 min, 53 ± 2 min, 46 ± 2 min, p = 0.001). Additionally, the mean LA instrumentation time was significantly lower in the OIC-1 compared with OIC-2 and 8MC groups (59 ± 3 min, 90 ± 5 min, 88 ± 4 min, p = 0.001). Duration of ablation along the esophagus was significantly decreased in OIC-1 and OIC-2 groups compared with 8MC group (3.29, 3.31, and 6.29 min, respectively, p = 0.001) (Fig. 3).


Figure 3
View larger version (24K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3 Time Intervals

(A) Fluoroscopy time, (B) left atrial (LA) instrumentation time, and (C) ablation along the esophagus time in the 3 study groups. Abbreviations as in Figure 2.

 
Complications.   There was one transient ischemic attack in the OIC-1 group; it occurred on the day of the procedure. There were no additional cerebrovascular events during follow-up any of the groups. In no patient was coagulum formation detected using either type of catheter. During ablation, pops were heard in all patients in the OIC-1 group. There was a mean of 1.3 pops heard per patient (Fig. 4A). Although OICs generate echogenic microbubbles as the result of saline infusion, there was a significant increase in microbubble density detected by ICE coinciding with pop formation. No pops were experienced in either the 8MC or OIC-2 groups (p = 0.001), After a pop was heard, we checked the cardiac silhouette by using fluoroscopy, and we screened the pericardial space by using ICE to look for pericardial effusions.


Figure 4
View larger version (12K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4 Periprocedural Complications

(A) Incidence of pops during ablation, (B) pericardial effusion, (C) pulmonary edema, and (D) gastrointestinal complaints. Abbreviations as in Figure 2.

 
Pericardial effusion complicated 20% of the procedures performed in the OIC-1 and none of the OIC-2 and 8MC groups (p = 0.001). Screening for pericardial effusion was performed with ICE during the ablation procedure. Once noted, a more detailed examination was performed with transthoracic transducers if needed. All patients had a thorough ICE procedure performed at the end of the ablation procedure. Two of the pericardial effusions were hemodynamically significant and required emergency pericardiocentesis (Fig. 4B). Small-to-moderate pericardial effusions with no hemodynamic significance were observed with a next day follow-up transthoracic echocardiogram. Warfarin was restarted if there is no increase in the size of the effusion. Two patients in the OIC-1 group developed periprocedural pulmonary edema requiring intravenous diuretic therapy (Fig. 4C).

Eleven patients (17%) in the OIC-1 group reported new symptoms of odynophagia or dysphagia within the first 3 weeks after the procedure; however, only 2 patients (3%) in the 8MC group and 3 patients (5%) in the OIC-2 developed these symptoms. (p = 0.03). Chest CT followed by an EGD was performed in all of these patients. Four patients in the OIC-1 group had evidence of focal areas of erythema along the anterior wall of the esophagus. None of the patients in the 8MC or the OIC-2 groups had any evidence of esophageal erythema. There were no signs of necrosis or bleeding in any group (Fig. 4D). None of the patients developed atrioesophageal fistula. A routine cardiac CT performed 3 months after the procedure demonstrated absence of significant (>50%) pulmonary vein stenosis in all groups.

Esophageal temperature recordings.   Patients in the OIC-1 group had a greater incidence of ET elevation compared with the OIC-2 and 8MC groups (94%, 60%, 70%, respectively, p = 0.02). The maximal ET recorded also was greater in the OIC-1 group compared with OIC-2 and 8MC groups (40.2 ± 1°C, 38.3 ± 1°C, and 38.6 ± 1°C, respectively, p = 0.001). The continuation of temperature increase after termination of RF energy application was significantly greater in the OIC-1 and 8MC groups compared with the OIC-2 group (1.42°C, 1.24°C, 0.64°C, respectively, p = 0.004). In the OIC-1 group, the average time for the ET temperature to return to baseline after termination of RF power delivery was significantly longer in the OIC-1 compared with OIC-2 and 8MC groups (39 ± 3 s, 18 ± 2 s, 13 ± 1 s, p = 0.001) (Fig. 5).


Figure 5
View larger version (30K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 5 Esophageal Temperature Elevation in the 3 Study Groups

(A) Incidence of ET elevation (%), (B) distribution of ET elevation, (C) postablation rise in ET, (D) time for ET to return to baseline postablation, and (E) postablation ET tracings. RF = radiofrequency; other abbreviations as in Figures 1 and 2.

 
In the OIC groups (OIC-1 and OIC-2), there was an average of 3 ET elevations per patient. This ET elevation occurred during isolation of the posterior aspect of the right and left posterior PV antrum. There was no correlation between ET and catheter tip temperature (mean = 38.2 ± 0.3°C, r2 = 0.2, p = NS), power (46 ±1 W, r2 = 0.26, p = NS), or impedance (93 ± 2 Ohms, r2 = 0.08, p = NS).

In the OIC-1 group, titrating down the power was usually unsuccessful in promptly reducing the ET to <38° C. However, in this group the ET elevation occurred when the generator settings were at a power of >35 W. Ninety percent of the ET elevation occurred with generator power >40 W.


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
This study tested the 3 commonly used catheter/energy-delivery strategies of electrical isolation of the pulmonary vein antra: the 8MC and 2 power delivery settings for the OIC. We did not test the 4-mm standard catheter because of its significant limitation of power delivery in areas of low blood flow, although some centers reported an excellent success rate with its use (10).

Short-term follow up during a period of 6 months showed a lower success rate in the lower power-lower irrigation rate group (OIC-2). This result may imply that higher power delivery is needed for effective lesion formation and subsequently clinical success. However, there was no difference between higher power/higher irrigation rate group (OIC-1) and the 8MC group. Thus power may not be the only determinant of effective lesion formation; instead, other factors like catheter stability to insure adequate catheter-tissue contact may be important as well.

Although the PVAI procedure performed using either catheter was effective in isolating pulmonary vein antra, the higher power/higher irrigation group (OIC-1) had less radiation exposure to the patient and operator. On average, this would result in a saving of 60 rads to the patient. In addition, saving approximately 20 min of fluoroscopy per procedure could translate to a significant reduction in radiation exposure to the operator. Thus, the use of OIC at high power and irrigation rate could substantially impact radiation safety.

Left atrial instrumentation time, which was reduced in the higher power/higher irrigation rate group (OIC-1), may theoretically correlate with reduction of thrombotic and hemorrhagic complications. Thrombotic complications generally occur as a result of the presence of the ablation system in the LA, and hemorrhagic complications generally occur resulting from the use of systemic anticoagulation during the procedure. It is reasonable to consider that a decrease in LA instrumentation time may translate into favorable clinical outcomes with a reduction in these complications. Additionally, the decrease in the LA instrumentation time may translate into a decrease in total procedure time, which could lessen the risks of conscious sedation. However, a recent study by Dixit et al. (11) reported that 8-mm tip achieved PV isolation in lesser time as compared with a closed irrigated (cooled-tip) catheter. It was suggested that this effect was mitigated by the use of electroanatomic mapping systems.

Despite the fact that the higher power/higher irrigation rate group (OIC-1) had a shorter duration of ablation along the esophagus, this did not translate into clinical benefit compared to the use of the 8MC. Indeed, there were more frequent and greater ET increases along with increased incidences of gastrointestinal symptoms and gross abnormalities detected by EGD. With the OIC, the depth of the direct resistive heating is significantly increased, which in turn increases the area of the effective heat source, resulting in higher power and temperature delivery. These factors will not only result in a larger lesion but may potentially increase the likelihood of collateral damage to adjacent structures because of higher thermal latency (prolonged ET elevation after ablation) (Fig. 5E).

Additionally, because the peak tissue temperature while using an OIC is approximately 2 to 5 mm less than the endocardial surface, there is a risk of intramural supra-boiling temperatures and pops (4). All patients in the higher power/higher irrigation rate group (OIC-1) had at least one occurrence of pop. In 2 patients, pops were complicated by acute pericardial effusion with cardiac tamponade, necessitating emergency pericardiocentesis. The mechanism of the majority of the pericardial effusions remains unclear. The majority of effusions were mild, slowly accumulating, and not hemodynamically significant. Similarly, even the larger effusions requiring pericardiocentesis did not reaccumulate despite heparin and subsequent oral anticoagulation therapy. In this subgroup, the mechanism of effusion may be severe inflammation due tissue injury causing a diffuse inflammatory state.

The posterior wall of the LA represents a vulnerable area for possible complications during AF catheter ablation. Not only it is the thinnest part of the LA, but it lies in close proximity to the esophagus as well (12). The use of higher-power delivery settings (OIC-1) in this area might have been the reason after the increased incidence of complications observed with OIC-1 group. It is possible that the use of lower-energy delivery settings in this area might have prevented both cardiac and esophageal complications.

The increased incidence of complications observed with the use of OIC at higher power and higher irrigation rate may be due to the limited effectiveness of ICE to monitor for excessive energy delivery to the tissue. It has been demonstrated that monitoring for intracardiac microbubble formation by ICE is an effective method to titrate energy delivery with the use of an 8-mm RF catheter for avoidance of excessive tissue heating (13,14). However, when using an OIC, the agitated saline droplets exiting the tiny catheter orifices at high velocity causes echogenic microbubble formation compromising the use of ICE for monitoring tissue overheating.

Two patients in OIC-1 group developed pulmonary edema requiring intravenous diuretic therapy. One patient had moderate left ventricular systolic dysfunction; however, the other patient had no history of structural heart disease. Both patients received more than 3 l of intravenous fluids during the procedure. Subsequently, during the course of this study with closer attention to fluid balance and with administration of diuretics, particularly for patients with a history of systolic dysfunction, this complication was no longer encountered.

Study limitations.   Our study is a randomized pilot one that was designed to study the safety and acute and subacute procedural success of PV antrum isolation performed using open irrigation catheters compared to 8-mm standard catheter. Thus, it has all the limitations inherent to a pilot study, including smaller sample size and selection bias.


    Conclusions
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
Despite evidence of improvement in LA instrumentation and fluoroscopy time, the use of OIC at a higher power and higher irrigation rate was associated with increased rates of complications. However, because of the nonhomogeneous nature of the LA with respect to wall thickness, one could postulate that a modified approach using shorter RF pulsatile applications as well as lower power and lower irrigation rates at some LA locations, such as the posterior wall, and greater power and higher irrigation rates at other LA locations, such as the anterior, roof and septal structures might prove to be an effective alternative strategy.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
1. Wazni O, Marrouche N, Martin D, et al. Radiofrequency ablation vs. antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation, a randomized trial JAMA 2005;293:2634-2640.[Abstract/Free Full Text]

2. Haissaguerre M, Shah DC, Jais P, et al. Mapping-guided ablation of pulmonary veins to cure atrial fibrillation Am J Cardiol 2000;86:9K-19K.[CrossRef][Web of Science][Medline]

3. Pappone C, Rosanio S, Oreto G, et al. Circumferential radiofrequency ablation of pulmonary vein ostia: a new anatomic approach for curing atrial fibrillation Circulation 2000;102:2619-2628.[Abstract/Free Full Text]

4. Nakagawa H, Yamanashi W, Pitha J, et al. Comparison in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation Circulation 1995;91:2264-2273.[Abstract/Free Full Text]

5. Otomo K, Yamanashi WS, Tondo C, et al. Why a large tip electrode makes a deeper lesion: effects of increase in electrode cooling and electrode-tissue interface area J Cardiovasc Electrophysiol 1998;9:47-54.[Web of Science][Medline]

6. Scavee C, Jais P, Hsu LF, et al. Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter Eur Heart J 2004;25:963-969.[Abstract/Free Full Text]

7. Thomas SP, Aggarwal G, Boyd AC, Jin Y, Ross DL. A comparison of open irrigated and non-irrigated tip catheter ablation for pulmonary vein isolation Europace 2004;6:330-335.[Abstract/Free Full Text]

8. Yokoyama K, Nakagawa H, Wittkampf FH, Pitha JV, Lazzara R, Jackman WM. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop Circulation 2006;113:11-19.[Abstract/Free Full Text]

9. Demazumder D, Mirotznik MS, Schwartzman D. Biophysics of radiofrequency ablation using an irrigated electrode J Interv Card Electrophysiol 2001;5:377-389.[CrossRef][Web of Science][Medline]

10. Schwartzman D, Nosbisch J, Housel D. Echocardiographically guided left atrial ablation: characterization of a new technique Heart Rhythm 2006;3:930-938.[CrossRef][Web of Science][Medline]

11. Dixit S, Gerstenfeld E, Callans D, et al. Comparison of cool tip versus 8-mm tip catheter in achieving electrical isolation of pulmonary veins for long-term control of atrial fibrillation: a prospective randomized pilot study J Cardiovasc Electrophysiol 2006;17:1074-1079.[CrossRef][Web of Science][Medline]

12. Nathan H, Eliakim M. The junction between the left atrium and the pulmonary veinsAn anatomic study of human hearts. Circulation 1966;34:412-422.[Abstract/Free Full Text]

13. Wazni OM, Rossillo A, Marrouche NF, et al. Embolic events and char formation during pulmonary vein isolation in patients with atrial fibrillation: impact of different anticoagulation regimens and importance of intracardiac echo imaging J Cardiovasc Electrophysiol 2005;16:576-581.[CrossRef][Web of Science][Medline]

14. Marrouche NF, Martin DO, Wazni O, et al. Phased-array intracardiac echocardiography monitoring during pulmonary vein isolation in patients with atrial fibrillation: impact on outcome and complications Circulation 2003;107:2710-2716.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
EuropaceHome page
D. Patel, P. Mohanty, L. Di Biase, Y. Wang, M. H. Shaheen, J. E. Sanchez, R. P. Horton, G. J. Gallinghouse, J. D. Zagrodzky, S. M. Bailey, et al.
The impact of statins and renin-angiotensin-aldosterone system blockers on pulmonary vein antrum isolation outcomes in post-menopausal females
Europace, January 10, 2010; (2010) eup387v1.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
T. Terasawa, E. M. Balk, M. Chung, A. C. Garlitski, A. A. Alsheikh-Ali, J. Lau, and S. Ip
Systematic Review: Comparative Effectiveness of Radiofrequency Catheter Ablation for Atrial Fibrillation
Ann Intern Med, August 4, 2009; 151(3): 191 - 202.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. D. O'Neill, M. Wright, S. Knecht, P. Jais, M. Hocini, Y. Takahashi, A. Jonsson, F. Sacher, S. Matsuo, K. T. Lim, et al.
Long-term follow-up of persistent atrial fibrillation ablation using termination as a procedural endpoint
Eur. Heart J., May 1, 2009; 30(9): 1105 - 1112.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. J. McGann, E. G. Kholmovski, R. S. Oakes, J. J.E. Blauer, M. Daccarett, N. Segerson, K. J. Airey, N. Akoum, E. Fish, T. J. Badger, et al.
New Magnetic Resonance Imaging-Based Method for Defining the Extent of Left Atrial Wall Injury After the Ablation of Atrial Fibrillation
J. Am. Coll. Cardiol., October 7, 2008; 52(15): 1263 - 1271.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. Matiello, L. Mont, D. Tamborero, A. Berruezo, B. Benito, E. Gonzalez, and J. Brugada
Cooled-tip vs. 8 mm-tip catheter for circumferential pulmonary vein ablation: comparison of efficacy, safety, and lesion extension
Europace, August 1, 2008; 10(8): 955 - 960.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.12.041v1
49/15/1634    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kanj, M. H.
Right arrow Articles by Natale, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kanj, M. H.
Right arrow Articles by Natale, A.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement