Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2006; 47:1487-1489, doi:10.1016/j.jacc.2006.01.006 (Published online 13 March 2006).
© 2006 by the American College of Cardiology Foundation
This Article
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.01.006v1
47/7/1487    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zei, P. C.
Right arrow Articles by Epstein, L. M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Zei, P. C.
Right arrow Articles by Epstein, L. M.

CORRESPONDENCE: RESEARCH CORRESPONDENCE

Modified Temporary Cardiac Pacing Using Transvenous Active Fixation Leads and External Re-Sterilized Pulse Generators

Paul C. Zei, MD, PhD*, Robert E. Eckart, DO and Laurence M. Epstein, MD

* Cardiac Arrhythmia Service, 75 Francis Street, Brigham and Women’s Hospital, Boston, Massachusetts 02115 (Email: pzei{at}partners.org).


To the Editor: Transcutaneous temporary pacing can be unreliable, and the stimulation can be uncomfortable; epicardial pacing requires thoracotomy (1,2). Transvenous percutaneous pacing systems placed "blindly," fluoroscopically, or electrocardiographically have therefore become the mainstay of temporary pacing (1). However, temporary pacing leads have a significant risk of dislodgement, infection, loss of capture, or even chamber perforation (3). In addition to risk of infection with prolonged central venous access, patient immobilization ("bed rest") can result in additional complications and economic burden.

As a result, use of temporary pacing systems is limited to no more than a few days (1). However, prolonged temporary pacing may sometimes be required. Treatment of infection in a pacemaker-dependent patient (4), post-operative recovery from cardiac valve surgery (5), or Lyme myocarditis with transient atrioventricular (AV) block (6) are representative of cases where prolonged pacing support may be necessary.

We present an alternative approach for modified temporary pacing support to address these scenarios. An active fixation pacing lead is placed fluoroscopically via percutaneous venous access and connected to a re-sterilized external pulse generator. This paper describes our clinical experience with this pacing system.

All patients who received modified temporary pacing support by the arrhythmia service at Brigham and Women’s Hospital from July 2000 through November 2004 were included in the analysis. The facility is a regional referral center for lead extraction, resulting in a significant number of patients admitted with infected devices. Patient clinical characteristics, details of the implantation procedure, and follow-up results were evaluated.

If the commonly accepted indication for pacing (7) was potentially reversible but likely to persist for more than one or two days, or if the patient had a treatable contraindication to permanent hardware implantation, a modified temporary pacing system was considered.

New standard active-fixation leads were selected at physician discretion. Pulse generators previously explanted from patients without known infection were re-sterilized and utilized. In a sterile procedure room, venous access was achieved using standard percutaneous technique (without cutdown) (Fig. 1). The pacing lead was advanced under fluoroscopic guidance, fixed to the myocardium, and tested in a standard fashion. The lead was then sutured to the skin using the anchoring sleeve (Fig. 1). After connection to the lead, the pulse generator (programmed SSI) was secured to the skin surface (Fig. 2).


Figure 1
View larger version (74K):
[in this window]
[in a new window]
 
Figure 1 Implant technique schematic. (A) The pacing lead is inserted via percutaneous access and placed in the right ventricle (or atrium). (B) An extendable-retractable active fixation lead is used to reduce migration. (C) The proximal lead remains external to the patient, is anchored via suture sleeve to the skin, and attached to the external pulse generator.

 

Figure 2
View larger version (64K):
[in this window]
[in a new window]
 
Figure 2 A newly implanted modified temporary pacing system is shown, with central venous access via axillary vein puncture. The proximal lead is external and sutured to the skin. A pulse generator is attached and then taped to the skin.

 
After implantation, patients were returned to their hospital beds and, unless contraindicated, were encouraged to ambulate. Plain film chest radiography and interrogation were performed the following day to exclude acute dislodgment. Patients were followed clinically to determine if a permanent device was still indicated and/or if concurrent infection or illness had resolved sufficiently to allow permanent device implantation. At the time of permanent implantation, the external pulse generator was detached followed by retraction of the active fixation mechanism from the myocardium under fluoroscopic guidance.

The 62 patients receiving modified temporary pacing were 68.4 ± 14.2 years of age (n = 37, 59.7% male), with a mean left ventricular ejection fraction of 47 ± 2%. Twenty-six patients (41%) had known coronary artery disease. The median hospital length of stay was 18 days. Indications for pacing were symptomatic AV block (n = 39, 62.9%), sick sinus syndrome (n = 17, 27.4%), and one instance of drug-related torsades de pointes.

Reasons for delaying permanent device implantation included bacteremia (n = 27, 43.5%), early post-cardiac surgery (n = 17, 27.4%), concurrent medical illness (n = 6, 9.7%), serologically confirmed Lyme disease (n = 3, 4.8%), and miscellaneous (n = 9, 14.5%). Among patients with bacteremia, most were elective admissions for lead and generator extraction for infection (n = 10, 37.0%) or primary diagnoses of endocarditis (n = 3, 11.1%).

Central venous access was via the internal jugular (n = 31, 47.7%), axillary (n = 21, 32.3%), subclavian (n = 11, 16.9%), cephalic (requiring cutdown, n = 1, 1.5%), and femoral (requiring bed rest, n = 1, 1.5%) veins. The majority of leads were placed in the right ventricular apex (n = 59, 95.2%), although three patients received right atrial pacing support.

The median duration of modified temporary pacemaker implantation was 7.5 days. Approximately two-thirds (n = 41, 66.1%) received permanent device implantation during index hospitalization. Of the 21 patients not felt to be candidates for permanent pacemaker implantation, 9 (42.9%) no longer required pacing support. All Lyme myocarditis patients recovered AV conduction, and none required permanent pacing, with time to recovery between 6 to 11 days. Among the post-operative patients, two died from non-arrhythmic causes during hospitalization, and five (23.8%) recovered conduction, obviating the need for permanent pacing. Among the remaining patients, nine (42.9%) died of non-arrhythmic causes during hospitalization, and three were transferred to the referring hospital for further treatment, primarily for infection, followed by permanent device implantation there.

No deaths were due to arrhythmia. No implant-related complications were observed, including lead dislodgment, perforation, pericardial effusion, or device infection. In those patients initially in an intensive care setting due to pacing support requirement, providers were encouraged to transfer the patient to a "step-down" or telemetry ward.

In the largest case series to date, we demonstrate an alternative approach to provide intermediate-term pacing (8). The advantages include lead position stability, allowance for full treatment of infections before permanent device placement, and an extended period of observation for recovery of normal conduction. Patients with significant risk of mortality are allowed to follow a natural history without the expense of permanent hardware implantation. These re-sterilized pulse generators are free of known infection and only contact the patient’s skin, resulting in minimal additional infection risk.

This series represents patients that are generally high risk, referrals, and have a high incidence of device infection. Patients with acute myocardial infarction requiring temporary pacing are generally treated in our cardiac catheterization laboratory; this important subset of patients is not addressed. These points may limit the generalizability of our findings. Other approaches to intermediate duration pacing have been described utilizing specialized pacing wires with active fixation mechanisms (9). Comparisons to these other temporary pacing systems should not be inferred and are beyond the scope of this analysis.

This pacing system requires no new technology and utilizes equipment already available to the implanting physician. It provides safe, stable, and reliable pacing in the individual who is immediately pacemaker-dependent but has reasons for delay in permanent device implantation. We believe this system can be readily implemented in such clinical scenarios.


    Footnotes
 
Please note: Dr. Zei is a research consultant for Biosense Webster Inc., and Dr. Epstein is a consultant for Boston Scientific Inc., Guidant Inc., and Medtronic Corp.


    References
 Top
 References
 
1. Lang R, David D, Klein HO, et al. The use of the balloon-tipped floating catheter in temporary transvenous cardiac pacing Pacing Clin Electrophysiol 1981;4:491-496.[CrossRef][Medline]

2. Trigano JA, Birkui PJ, Mugica J. Noninvasive transcutaneous cardiac pacingmodern instrumentation and new perspectives. Pacing Clin Electrophysiol 1992;15:1937-1943.[Medline]

3. Asano M, Mishima A, Ishii T, Takeuchi Y, Suzuki Y, Manabe T. Surgical treatment for right ventricular perforation caused by transvenous pacing electrodesa report of three cases. Surg Today 1996;26:933-935.[Medline]

4. Darouiche RO. Treatment of infections associated with surgical implants N Engl J Med 2004;350:1422-1429.[Free Full Text]

5. Koplan BA, Stevenson WG, Epstein LM, Aranki SF, Maisel WH. Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery J Am Coll Cardiol 2003;41:795-801.[Abstract/Free Full Text]

6. McAlister HF, Klementowicz PT, Andrews C, Fisher JD, Feld M, Furman S. Lyme carditisan important cause of reversible heart block. Ann Intern Med 1989;110:339-345.[Abstract/Free Full Text]

7. Gregoratos G, Abrams J, Epstein AE, et al. ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devicessummary article. J Cardiovasc Electrophysiol 2002;13:1183-1199.[CrossRef][Web of Science][Medline]

8. Rastan AJ, Doll N, Walther T, Mohr FW. Pacemaker dependent patients with device infection—a modified approach Eur J Cardiothorac Surg 2005;27:1116-1118.[Abstract/Free Full Text]

9. Pinto N, Jones TK, Dyamenahalli U, Shah MJ. Temporary transvenous pacing with an active fixation bipolar lead in childrena preliminary report. Pacing Clin Electrophysiol 2003;26:1519-1522.[Medline]




This article has been cited by other articles:


Home page
EuropaceHome page
P. Korantzopoulos, K. P. Letsas, G. Grekas, and J. A. Goudevenos
Pacemaker dependency after implantation of electrophysiological devices
Europace, September 1, 2009; 11(9): 1151 - 1155.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
j.jacc.2006.01.006v1
47/7/1487    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zei, P. C.
Right arrow Articles by Epstein, L. M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Zei, P. C.
Right arrow Articles by Epstein, L. M.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement