Advertisement





Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2005; 46:1002-1005, doi:10.1016/j.jacc.2005.05.068 (Published online 20 September 2005).
© 2005 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (60)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ako, J.
Right arrow Articles by Fitzgerald, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ako, J.
Right arrow Articles by Fitzgerald, P. J.

CLINICAL RESEARCH: INTERVENTIONAL CARDIOLOGY

Late Incomplete Stent Apposition After Sirolimus-Eluting Stent Implantation

A Serial Intravascular Ultrasound Analysis

Junya Ako, MD*, Yoshihiro Morino, MD*, Yasuhiro Honda, MD, FACC*, Ali Hassan, MD*, Shinjo Sonoda, MD, PhD*, Paul G. Yock, MD, FACC*, Martin B. Leon, MD, FACC{dagger}, Jeffrey W. Moses, MD, FACC{dagger}, Heidi N. Bonneau, RN, MS{ddagger} and Peter J. Fitzgerald, MD, PhD, FACC*,*

* Center for Research in Cardiovascular Interventions, Stanford University Medical Center, Stanford, California
{dagger} Lenox Hill Hospital, New York, New York
{ddagger} Highlands Consulting Inc., San Jose, California.

Manuscript received August 16, 2004; revised manuscript received May 25, 2005, accepted May 31, 2005.

* Reprint requests and correspondence: Dr. Peter J. Fitzgerald, Center for Research in Cardiovascular Interventions, Stanford University Medical Center, 300 Pasteur Drive, H3554, Stanford, California 94305-5637. (Email: ivus{at}crci.stanford.edu).


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES: We sought to identify the frequency of incomplete stent apposition (ISA) in sirolimus-eluting stents (SES) and clarify its findings and clinical sequelae.

BACKGROUND: Late-acquired ISA has been reported in bare-metal stents (BMS) and brachytherapy and recently in drug-eluting stents. However, the characteristics of late ISA in SES have not been clarified.

METHODS: From the SIRIUS trial, a randomized, multicenter study comparing SES and BMS, serial qualitative intravascular ultrasound (IVUS; at stent implantation and eight-month follow-up) was available in 141 patients (BMS: n = 61; SES: n = 80). The IVUS images were reviewed for the presence of ISA.

RESULTS: Incomplete stent apposition at follow-up was observed in 19 patients (BMS: n = 6 [9.8%]; SES: n = 13 [16.3%]; p = NS). Among these, 12 had ISA after intervention and at follow-up (persistent ISA). Late-acquired ISA was seen in the remaining seven cases, all from the SES group (BMS: n = 0; SES: n = 7 [8.7%]; p < 0.05). In late-acquired ISA, there was an increase in external elastic membrane area (after intervention: 16.2 ± 2.7 m2; follow-up: 18.9 ± 3.6 mm2; p < 0.05). The location of stent-vessel wall separation was primarily at the stent edges in persistent ISA cases, whereas late-acquired ISA in SES occurred mostly in the mid portion of the stent. There were no negative clinical events reported for any ISA cases at 12-month clinical follow-up.

CONCLUSIONS: Late ISA was observed in 8.7% of patients after SES implantation. There were no negative clinical events associated with this IVUS finding at 12-month clinical follow-up; however, careful long-term follow-up will be necessary.

Abbreviations and Acronyms
  BMS = bare-metal stent
  DES = drug-eluting stent
  EEM = external elastic membrane
  ISA = incomplete stent apposition
  IVUS = intravascular ultrasound
  SES = sirolimus-eluting stent
  SIRIUS = Sirolimus-Eluting Stent in De Novo Coronary Lesions study


In recent years, stent-based local drug delivery has emerged as a promising technology to reduce restenosis. Several clinical studies have shown that drug-eluting stents (DES) achieve a striking inhibition of neointimal hyperplasia (1–6).

Drug-eluting stents, as well as intravascular brachytherapy, target several mechanisms to decrease proliferation of vascular smooth muscle cells, which contribute to the restenotic process. However, intravascular brachytherapy was later associated with a considerably high incidence of late thrombosis, complicating the clinical outcomes (7,8). Through the use of intravascular ultrasound (IVUS), several unusual observations, including unhealed stent edge dissections and incomplete stent apposition (ISA), were made after brachytherapy (9,10). This unusual IVUS finding has received much attention, given the concern that ISA could possibly contribute to one of the factors related to thrombosis (8,11). To date, the incidence of incomplete apposition in DES, however, has not been well investigated. Thus, the aim of our study was to identify the frequency of ISA in sirolimus-eluting stents (SES) and clarify its findings and clinical sequelae.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Study population and protocol.   The study population consisted of patients with completed serial IVUS analysis from the Sirolimus-Eluting Stent in De Novo Coronary Lesions (SIRIUS) trial (12), a multicenter, randomized, double-blind study that evaluated the safety and effectiveness of the sirolimus-coated Bx Velocity stent compared with the uncoated Bx Velocity balloon-expandable stent (Cordis Corp., Warren, New Jersey) in de novo native coronary artery lesions. At 16 sites, IVUS was performed after the procedure and at eight-month follow-up. Lesions ≥15 mm and ≤30 mm in length and vessels ≥2.5 mm and ≤3.5 mm in diameter were included. Multiple stent use was allowed as needed at the operator’s discretion. Two types of stent length (8 and 18 mm) were available for both groups, with diameter line-ups of 2.5, 3.0, and 3.5 mm. Protocols were approved by the local human subjects committee in all participating institutions, and all patients gave written, informed consent.

IVUS imaging and analysis.   After administration of intracoronary nitroglycerin, IVUS images were acquired using commercially available imaging systems with automated transducer pullback (0.5 mm/s). The IVUS images were interpreted at an independent core laboratory (Stanford Cardiovascular Core Analysis Laboratory) blinded to the treatment protocols.

Qualitative analysis involved review of all IVUS tapes for the presence of ISA. Incomplete stent apposition was defined as one or more stent struts clearly separated from the vessel wall with evidence of blood speckles behind the strut in a vessel segment not associated with any side branches. Resolved ISA was defined as ISA observed at baseline but not at follow-up. Persistent ISA was defined as ISA observed both at baseline and follow-up. Late-acquired ISA was defined as ISA observed at follow-up but not at baseline. Typical IVUS images of late-acquired ISA are shown in Figures 1 and 2.Go The adjudication of the opinions was based on the consensus of three independent analysts (J. A., Y. H., and S. S.).



View larger version (65K):
[in this window]
[in a new window]
 
Figure 1 Intravascular ultrasound images of sirolimus-eluting stents with late incomplete stent apposition (A) after stent implantation and (B) at eight-month follow-up. The stent was well apposed to the vessel wall at the time of implantation.

 


View larger version (138K):
[in this window]
[in a new window]
 
Figure 2 Longitudinal images showing late incomplete stent apposition after sirolimus-eluting stent implantation: (A) after stent implantation; (B) at eight-month follow-up. Detachment of the vessel wall (arrows) from stent strut (dotted lines) was observed in the mid portion of the stent and in the relatively normal side of the vessel wall.

 
Quantitative analysis was performed using computerized planimetry (TapeMeasure, Indec Systems Inc., Mountain View, California). Quantitative measurements of incompletely apposed sections included the external elastic membrane (EEM), stent, and lumen area. The angle of ISA was measured using an electronic protractor centered on the lumen. We also measured the baseline plaque thickness corresponding to the apposed and non-apposed wall segments. Quantitative measurements were performed at the area of greatest stent-lumen separation at follow-up IVUS imaging and matched with the corresponding image from after the intervention.

Statistical analysis.   Statistical analysis was performed using StatView 5.0 (SAS Institute Inc., Cary, North Carolina). Continuous data are presented as the mean value ± SD, and categorical data are presented as frequencies. Continuous variables between persistent ISA and late-acquired ISA were compared by use of the unpaired Student t test; otherwise, the paired Student t test was used for comparing continuous variables. Categorical variables were compared using chi-square statistics or the Fisher exact test. The Fisher exact test was used if there was an expected cell value <5. Significance was assumed at a value of p < 0.05.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
A total of 1,101 patients were enrolled in the SIRIUS trial, with serial qualitative IVUS analyses available in 141 patients (bare-metal stents [BMS]: n = 61; SES: n = 80). Table 1 summarizes the frequency of ISA in the SIRIUS trial. At follow-up, ISA was observed in 19 patients (BMS: n = 6 [9.8%]; SES: n = 13 [16.3%]; p = NS). A synchronous comparison between the post-interventional IVUS image and the follow-up IVUS image showed 12 cases of ISA within both vessel segments (persistent ISA) (BMS: n = 6 [9.8%]; SES: n = 6 [7.5%]; p = NS). The other seven cases, all of which were randomized to the SES group, demonstrated ISA only at follow-up (late-acquired ISA). In 10 cases, ISA observed at baseline was resolved and was not present at follow-up (resolved ISA). In patients with late-acquired ISA, there were six males and one female (ages 56 ± 11 years), with cardiac risk factors of hypercholesterolemia in one (14%), diabetes mellitus in one (14%), and hypertension in five (71%). In two late-acquired ISA cases, there were two loci of stent-vessel separation within one stented segment.


View this table:
[in this window]
[in a new window]
 
Table 1. Frequency of ISA in BMS and SES
 
Among SES, the frequency of late-acquired ISA was 8.7% (5 of 57) with single stent implantation and 8.7% (2 of 23) with multiple stent implantations. There was no late-acquired ISA originating from stent overlap. Three late-acquired ISA segments showed an increase >20% in EEM, including one angiographically apparent aneurysm. The increased area for both the EEM and lumen was seen without change in plaque area (Table 2). Seven of nine late-acquired ISA segments were directly associated with the nearly normal vessel walls with thinner baseline plaque than the opposite arc. The average baseline plaque was thinner on the non-apposed side than on the opposite side (0.47 ± 0.28 mm vs. 1.1 ± 0.58 mm, respectively; p < 0.05).


View this table:
[in this window]
[in a new window]
 
Table 2. Baseline and Follow-Up Intravascular Ultrasound Cross-Sectional Measurements of Late-Acquired Incomplete Stent Apposition
 
Table 3 shows comparative data between cases of persistent ISA versus late-acquired ISA. Late-acquired ISA had greater lumen separation from stent struts, with positive vessel remodeling. The location of stent-vessel wall separation was primarily at the edges in persistent ISA, whereas late-acquired ISA of SES occurred mostly in the mid portion of the stent.


View this table:
[in this window]
[in a new window]
 
Table 3. Persistent and Late-Acquired ISA
 

    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
This serial IVUS comparative study from the SIRIUS trial identified an 8.7% incidence of late-acquired ISA seen only in the SES group. Similarly, the RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions (RAVEL) trial reported a 20% incidence of ISA in SES at follow-up (6). However, the RAVEL trial lacked post-stent IVUS analysis; therefore, both late-acquired ISA and persistent ISA were considered to be included, contributing to the high incidence reported. In our present study, late-acquired ISA did not occur in the BMS group. Late-acquired ISA is reported to occur at a frequency of 1% to 5% with BMS implantation (13,14). Although direct comparisons between these studies cannot be made because of patient differences and multi-device approaches (13), our results suggest that ISA occurred with a greater incidence in SES compared with BMS.

The mechanism of late-acquired ISA in SES was mainly focal positive vessel remodeling, as previously reported in BMS (14,15). In three ISA segments, there was an increase >20% in vessel area. The plaque area was not significantly different between post-intervention and follow-up, which suggests that plaque regression (9), as seen with intravascular brachytherapy, is not the primary reason for late-acquired ISA in SES. Incomplete stent apposition was mainly observed on the relatively disease-free side of the vessel wall (78%), which lends further support to this theory. More injury to the vasoelastic normal wall, coupled with a drug that may delay the healing process, could contribute to this phenomenon.

The frequency of ISA per patient was quite similar in both single and multiple stent cases. In addition, late-acquired ISA was not seen originating from stent overlap. Thus, late-acquired ISA may not be a dose-dependent event of sirolimus. From our patient subset, multiple stenting did not seem to predispose vessel wall separation from stent struts; however, studies involving a larger patient population may be necessary to confirm this observation.

Previous reports demonstrated ISA at the edges of the stent in intravascular brachytherapy (16), as well as ISA after BMS implantation (13). In the present study, late-acquired ISA in SES largely occurred in the mid portion of the stent. The location within the stent, distinct from previous reports, characterizes late-acquired ISA with SES, in agreement with the results of the RAVEL trial. The different locations of ISA indicate involvement of different biologic processes in the focal positive remodeling and subsequent development of ISA in SES. It is intriguing to note that there is relatively less efficacy of neointimal suppression at the edges in SES (17). This asymmetric distribution of neointimal tissue within the stent may be associated with the location of late-acquired ISA with SES. Late-acquired ISA may occur due to profound localized inhibition of neointimal formation in disease-free segments of the vessel, delaying early reparative events that usually enable the vessel wall to incorporate a stent. Flow dynamics in these segments may also favor positive remodeling of the artery at sites of delayed neointimal formation, resulting in late-acquired ISA.

Incomplete stent apposition at the stent edges provides an exit for both inward and outward blood flow. On the other hand, there is a hypothetical concern that non-apposed segments in the middle of the stent may produce a different blood flow property with its cul-de-sac formation. Despite findings of either persistent or late-acquired ISA, no negative clinical events were associated with these cases at 12-month clinical follow-up. The three-year data from RAVEL trial also fail to show any increase in adverse cardiac events, despite the high incidence of incomplete apposition at follow-up (18). It is still unclear whether this particular IVUS finding may relate to future adverse events. We have yet to elucidate the natural history of this unusual IVUS finding. However, in view of the increased incidence of late-acquired ISA in SES, careful long-term follow-up is warranted.

Study limitations.   First, this study is based on a relatively small number of late-acquired ISA cases, raising the possibility of selection bias. Second, IVUS is unable to identify neointima <100 µm in thickness and acellular proteinaceous material; thus, we are not able to evaluate re-endothelialization surrounding the stent struts. Third, there is a lack of evidence on clinical sequelae related to this particular morphologic IVUS finding.

Conclusions.   Serial IVUS analysis from the SIRIUS trial found an 8.7% incidence of late ISA after SES implantation, with late ISA being observed primarily in the middle of the stent. Despite freedom from clinical events, careful long-term follow-up may be necessary, especially in a case environment that may have variable antiplatelet therapy.


    Footnotes
 
Dr. Yock received a grant from and is a stock shareholder for Johnson & Johnson. Dr. Leon is a stock shareholder for Johnson & Johnson. Dr. Moses is a consultant and stock shareholder for Johnson & Johnson. Dr. Fitzgerald is a consultant for Johnson & Johnson.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
1. Hong MK, Mintz GS, Lee CW, et al. Paclitaxel coating reduces in-stent intimal hyperplasia in human coronary arteriesa serial volumetric intravascular ultrasound analysis from the Asian Paclitaxel-Eluting Stent Clinical Trial (ASPECT). Circulation 2003;107:517-520.[Abstract/Free Full Text]

2. Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease N Engl J Med 2004;350:221-231.[Abstract/Free Full Text]

3. Honda Y, Grube E, de La Fuente LM, Yock PG, Stertzer SH, Fitzgerald PJ. Novel drug-delivery stentintravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system. Circulation 2001;104:380-383.[Abstract/Free Full Text]

4. Kataoka T, Grube E, Honda Y, et al. 7-Hexanoyltaxol-eluting stent for prevention of neointimal growthan intravascular ultrasound analysis from the Study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE). Circulation 2002;106:1788-1793.[Abstract/Free Full Text]

5. Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization N Engl J Med 2002;346:1773-1780.[Abstract/Free Full Text]

6. Serruys PW, Degertekin M, Tanabe K, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial Circulation 2002;106:798-803.[Abstract/Free Full Text]

7. Costa MA, Sabat M, van der Giessen WJ, et al. Late coronary occlusion after intracoronary brachytherapy Circulation 1999;100:789-792.[Abstract/Free Full Text]

8. Waksman R. Late thrombosis after radiationsitting on a time bomb. Circulation 1999;100:780-782.[Free Full Text]

9. Morino Y, Bonneau HN, Fitzgerald PJ. Vascular brachytherapywhat have we learned from intravascular ultrasound?. J Invasive Cardiol 2001;13:409-416.[Medline]

10. Mintz GS, Weissman NJ, Fitzgerald PJ. Intravascular ultrasound assessment of the mechanisms and results of brachytherapy Circulation 2001;104:1320-1325.[Free Full Text]

11. Farb A, Burke AP, Kolodgie FD, Virmani R. Pathological mechanisms of fatal late coronary stent thrombosis in humans Circulation 2003;108:1701-1706.[Abstract/Free Full Text]

12. Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery N Engl J Med 2003;349:1315-1323.[Abstract/Free Full Text]

13. Shah VM, Mintz GS, Apple S, Weissman NJ. Background incidence of late malapposition after bare-metal stent implantation Circulation 2002;106:1753-1755.[Abstract/Free Full Text]

14. Nakamura M, Kataoka T, Honda Y, et al. Late incomplete stent apposition and focal vessel expansion after bare metal stenting Am J Cardiol 2003;92:1217-1219.[CrossRef][Web of Science][Medline]

15. Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition Circulation 2003;107:2660-2663.[Abstract/Free Full Text]

16. Kozuma K, Costa MA, Sabate M, et al. Late stent malapposition occurring after intracoronary beta-irradiation detected by intravascular ultrasound J Invasive Cardiol 1999;11:651-655.[Web of Science][Medline]

17. Morino Y, Ako J, Sonoda S, et al. Neointimal distribution within sirolimus-eluting stentsa 3-D IVUS interim analysis from the SIRIUS trial. Circulation 2002;106(Suppl):391.

18. Fajadet J, Morice MC, Bode C, et al. Maintenance of long-term clinical benefit with sirolimus-eluting coronary stentsthree-year results of the RAVEL trial. Circulation 2005;111:1040-1044.[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
F. Alfonso, M.-J. Perez-Vizcayno, M. Ruiz, A. Suarez, M. Cazares, R. Hernandez, J. Escaned, C. Banuelos, P. Jimenez-Quevedo, and C. Macaya
Coronary aneurysms after drug-eluting stent implantation clinical, angiographic, and intravascular ultrasound findings.
J. Am. Coll. Cardiol., June 2, 2009; 53(22): 2053 - 2060.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
S. Verheye, P. Agostoni, K. D. Dawkins, J. Dens, W. Rutsch, D. Carrie, J. Schofer, C. Lotan, C. L. Dubois, S. A. Cohen, et al.
The GENESIS (Randomized, Multicenter Study of the Pimecrolimus-Eluting and Pimecrolimus/Paclitaxel-Eluting Coronary Stent System in Patients with De Novo Lesions of the Native Coronary Arteries) Trial
J. Am. Coll. Cardiol. Intv., March 1, 2009; 2(3): 205 - 214.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. K.M. Hassan, S. C. Bergheanu, T. Stijnen, B. L. van der Hoeven, J. D. Snoep, J. W.M. Plevier, M. J. Schalij, and J. W. Jukema
Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
Eur. Heart J., January 21, 2009; (2009) ehn553v1.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
Y. Honda and P. J. Fitzgerald
Frontiers in Intravascular Imaging Technologies
Circulation, April 15, 2008; 117(15): 2024 - 2037.
[Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
B. L. van der Hoeven, S.-S. Liem, J. Dijkstra, S. C. Bergheanu, H. Putter, M. L. Antoni, D. E. Atsma, M. Bootsma, K. Zeppenfeld, J. W. Jukema, et al.
Stent Malapposition After Sirolimus-Eluting and Bare-Metal Stent Implantation in Patients with ST-Segment Elevation Myocardial Infarction: Acute and 9-Month Intravascular Ultrasound Results of the MISSION! Intervention Study
J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 192 - 201.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A. Colombo and A. Latib
Late incomplete stent apposition after drug-eluting stent implantation: a true risk factor or "an innocent bystander"?
Heart, March 1, 2008; 94(3): 253 - 254.
[Full Text] [PDF]


Home page
HeartHome page
R Hoffmann, M-C Morice, J W Moses, P J Fitzgerald, L Mauri, G Breithardt, J Schofer, P W Serruys, H-P Stoll, and M B Leon
Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials
Heart, March 1, 2008; 94(3): 322 - 328.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. L. van der Hoeven, S.-S. Liem, J. W. Jukema, N. Suraphakdee, H. Putter, J. Dijkstra, D. E. Atsma, M. Bootsma, K. Zeppenfeld, P. V. Oemrawsingh, et al.
Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction: 9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study.
J. Am. Coll. Cardiol., February 12, 2008; 51(6): 618 - 626.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
J. Aoki, A. Kirtane, M. B. Leon, and G. Dangas
Coronary artery aneurysms after drug-eluting stent implantation.
J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 14 - 21.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
E. Romagnoli, G. M. Sangiorgi, J. Cosgrave, E. Guillet, and A. Colombo
Drug-eluting stenting the case for post-dilation.
J. Am. Coll. Cardiol. Intv., February 1, 2008; 1(1): 22 - 31.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
B. Doyle, C. S. Rihal, C. J. O'Sullivan, R. J. Lennon, H. J. Wiste, M. Bell, J. Bresnahan, and D. R. Holmes Jr
Outcomes of Stent Thrombosis and Restenosis During Extended Follow-Up of Patients Treated With Bare-Metal Coronary Stents
Circulation, November 20, 2007; 116(21): 2391 - 2398.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Windecker and B. Meier
Late Coronary Stent Thrombosis
Circulation, October 23, 2007; 116(17): 1952 - 1965.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M.-K. Hong, G. S. Mintz, C. W. Lee, D.-W. Park, S.-W. Lee, Y.-H. Kim, D.-H. Kang, S.-S. Cheong, J.-K. Song, J.-J. Kim, et al.
Impact of Late Drug-Eluting Stent Malapposition on 3-Year Clinical Events
J. Am. Coll. Cardiol., October 9, 2007; 50(15): 1515 - 1516.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Jaffe and B. H. Strauss
Late and Very Late Thrombosis of Drug-Eluting Stents: Evolving Concepts and Perspectives
J. Am. Coll. Cardiol., July 10, 2007; 50(2): 119 - 127.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
N. J. Weissman, S. G. Ellis, E. Grube, K. D. Dawkins, J. D. Greenberg, T. Mann, L. A. Cannon, P. A. Cambier, S. Fernandez, G. S. Mintz, et al.
Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses: a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials
Eur. Heart J., July 1, 2007; 28(13): 1574 - 1582.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. A. Siqueira, A. A. Abizaid, J. d. R. Costa, F. Feres, L. A. Mattos, R. Staico, A. A. Abizaid, L. F. Tanajura, A. Chaves, M. Centemero, et al.
Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes
Eur. Heart J., June 1, 2007; 28(11): 1304 - 1309.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
G. S. Mintz
What to Do About Late Incomplete Stent Apposition?
Circulation, May 8, 2007; 115(18): 2379 - 2381.
[Full Text] [PDF]


Home page
CirculationHome page
S. Cook, P. Wenaweser, M. Togni, M. Billinger, C. Morger, C. Seiler, R. Vogel, O. Hess, B. Meier, and S. Windecker
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Circulation, May 8, 2007; 115(18): 2426 - 2434.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. Matsumoto, J. Shite, T. Shinke, H. Otake, Y. Tanino, D. Ogasawara, T. Sawada, O. L. Paredes, K.-i. Hirata, and M. Yokoyama
Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography
Eur. Heart J., April 2, 2007; 28(8): 961 - 967.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. E. Kandzari, M. B. Leon, J. J. Popma, P. J. Fitzgerald, C. O'Shaughnessy, M. W. Ball, M. Turco, R. J. Applegate, P. A. Gurbel, M. G. Midei, et al.
Comparison of Zotarolimus-Eluting and Sirolimus-Eluting Stents in Patients With Native Coronary Artery Disease: A Randomized Controlled Trial
J. Am. Coll. Cardiol., December 19, 2006; 48(12): 2440 - 2447.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Kimmelstiel
Multislice Computed Tomography After Left Main Drug-Eluting Stenting: Are We Putting the CarT Before the Horse?
Circulation, August 15, 2006; 114(7): 616 - 619.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. S. Mintz and N. J. Weissman
Intravascular Ultrasound in the Drug-Eluting Stent Era
J. Am. Coll. Cardiol., August 1, 2006; 48(3): 421 - 429.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Jimenez-Quevedo, M. Sabate, D. J. Angiolillo, M. A. Costa, F. Alfonso, J. A. Gomez-Hospital, R. Hernandez-Antolin, C. Banuelos, J. Goicolea, F. Fernandez-Aviles, et al.
Vascular Effects of Sirolimus-Eluting Versus Bare-Metal Stents in Diabetic Patients: Three-Dimensional Ultrasound Results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial
J. Am. Coll. Cardiol., June 6, 2006; 47(11): 2172 - 2179.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. R. Dixon, C. L. Grines, and W. W. O'Neill
The Year in Interventional Cardiology
J. Am. Coll. Cardiol., April 18, 2006; 47(8): 1689 - 1706.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (60)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ako, J.
Right arrow Articles by Fitzgerald, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ako, J.
Right arrow Articles by Fitzgerald, P. J.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement