Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2005; 46:147-154, doi:10.1016/j.jacc.2005.03.071
© 2005 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (431)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leber, A. W.
Right arrow Articles by Boekstegers, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leber, A. W.
Right arrow Articles by Boekstegers, P.
Related Collections
Right arrowRelated Article

EXPEDITED REVIEW

Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography

A Comparative Study With Quantitative Coronary Angiography and Intravascular Ultrasound

Alexander W. Leber, MD*,*, Andreas Knez, MD*, Franz von Ziegler, MD*, Alexander Becker, MD*, Konstantin Nikolaou, MD{dagger}, Stephan Paul, MD*, Bernd Wintersperger, MD{dagger}, Maximilian Reiser, MD{dagger}, Christoph R. Becker, MD{dagger}, Gerhard Steinbeck, MD* and Peter Boekstegers, MD*

Department of Cardiology, University of Munich, Munich, Germany.
{dagger} Department of Clinical Radiology, University of Munich, Munich, Germany.

Manuscript received December 16, 2004; revised manuscript received February 28, 2005, accepted March 10, 2005.

* Reprint requests and correspondence: Dr. Alexander W. Leber, MD, University of Munich, Klinikum Grosshadern, Medizinische Klinik I, Marchioninistraße 15, 81377 München, Germany. (Email: aleber{at}med.uni-muenchen.de).


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES: The aim of the present study was to determine the diagnostic accuracy of 64-slice computed tomography (CT) to identify and quantify atherosclerotic coronary lesions in comparison with catheter-based angiography and intravascular ultrasound (IVUS).

BACKGROUND: Currently, the ability of multislice CT to quantify the degree of coronary artery stenosis and dimensions of coronary plaques has not been evaluated.

METHODS: We included 59 patients scheduled for coronary angiography due to stable angina pectoris. A contrast-enhanced 64-slice CT (Senation 64, Siemens Medical Solutions, Forchheim, Germany) was performed before the invasive angiogram. In a subset of 18 patients, IVUS of 32 vessels was part of the catheterization procedure.

RESULTS: In 55 of 59 patients, 64-slice CT enabled the visualization of the entire coronary tree with diagnostic image quality (American Heart Association 15-segment model). The overall correlation between the degree of stenosis detected by quantitative coronary angiography compared with 64-slice CT was r = 0.54. Sensitivity for the detection of stenosis <50%, stenosis >50%, and stenosis >75% was 79%, 73%, and 80%, respectively, and specificity was 97%. In comparison with IVUS, 46 of 55 (84%) lesions were identified correctly. The mean plaque areas and the percentage of vessel obstruction measured by IVUS and 64-slice CT were 8.1 mm2 versus 7.3 mm2 (p < 0.03, r = 0.73) and 50.4% versus 41.1% (p < 0.001, r = 0.61), respectively.

CONCLUSIONS: Contrast-enhanced 64-slice CT is a clinically robust modality that allows the identification of proximal coronary lesions with excellent accuracy. Measurements of plaque and lumen areas derived by CT correlated well with IVUS. A major limitation is the insufficient ability of CT to exactly quantify the degree of stenosis.

Abbreviations and Acronyms
  CSA = cross-sectional area
  CT = computed tomography
  EEM = external elastic membrane
  IVUS = intravascular ultrasound
  LAD = left anterior descending artery
  LCX = left circumflex artery
  MSCT = multislice computed tomography
  QCA = quantitative coronary angiography
  RCA = right coronary artery


A noninvasive method that would allow the evaluation of coronary stenoses with a comparable accuracy to catheter-based angiography would have enormous clinical value. The recent development of 16-slice computed tomography (CT) already constitutes an important step forward in noninvasive angiography and, although remarkable results to identify high-grade coronary stenoses were reported from several groups, it is evident that this technology is still affected by numerous limitations (1–5). Because of spatial resolution, the reliable identification of coronary lesions is restricted to major coronary branches with a diameter of at least 2 mm. Partial volume effects caused by coronary calcifications frequently count for false-positive and false-negative results. Furthermore, it is consistently reported that because of the limited temporal resolution, motion artifacts can only be avoided in patients with heart rates of <65 beats/min (3–7). Those limitations probably contributed to the fact that all existing studies focused on the detection of high-grade stenosis only and, until now, no attempt was directed toward a CT-derived stenosis quantification. For clinical purposes, however, it also is necessary to accurately determine the severity of a lesion because the therapeutic consequence of a 50% or a 90% stenosis may be completely different. The recent introduction of a new scanner generation with improved spatial and temporal resolution generating 64 slices per rotation and covering the entire volume of the heart in 8 to 9 s promises a significant improvement of image quality that may allow a more precise evaluation of coronary stenosis. Thus, the aim of the present study was to determine the diagnostic accuracy of a 64-slice CT that offers an isotropic voxel resolution of 0.4 x 0.4 x 0.4 mm to identify and quantify atherosclerotic coronary lesions in comparison with catheter-based angiography and intravascular ultrasound (IVUS).


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Patients.   From July to November 2004, we studied 59 consecutive patients (no previously known coronary artery disease [n = 49], patients with previous angioplasty [n = 10]) scheduled for conventional coronary angiography because of stable angina pectoris who were suitable for a 64-slice CT scan at least one day before the catheterization procedure. Patients with atrial fibrillation, previous bypass surgery, previous stenting of >1 vessel, an unstable clinical condition, or a contraindication to the administration of contrast agent were excluded. The 64-slice CT scan was performed within two days before coronary angiography in all patients. The study protocol included the oral administration of 50 mg of metoprolol 60 min before the scheduled CT scan in patients with heart rates >70 beats/min. However, in the presence of contraindications for a beta-blocker or an unsatisfactory lowering of the heart rate, the scan was performed even at higher heart rates. The study protocol was approved by the institutional ethics committee of the Grosshadern Hospital of the University of Munich, and all patients gave informed consent to participate in the study.

The 64-slice CT scanning technique.   Computed tomographic angiography was performed using a 64-slice CT scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany). A bolus of 80 ml of contrast agent (Solutrast 300, 300 mgI/ml–1, Altana, Konstanz, Germany) was injected intravenously (5 ml/s). As soon as the signal in the ascending aorta reached a predefined threshold of 100 HU, the scan started automatically and the entire volume of the heart was acquired during one breathhold in 8 to 9 s with simultaneous recording of the electrocardiographic trace. The detector collimation was 0.6 mm, gantry rotation speed was 330 ms per rotation, tube voltage was 120 kV at a current of 550 to 750 mAs (depending on patient size) during 55% of the cardiac cycle (diastole), and a reduction of the current by 80% was performed during the remaining time of the R-R interval, leading to an estimated mean effective radiation dose of approximately 10 to 14 mSv. By applying a half scan algorithm (only data from a 180° gantry rotation is used for image reconstruction) in patients with heart rates <65 beats/min, acquisition time was reduced to 165 ms (gantry rotation time/2 = 330 ms/2). For heart rates >65 beats/min, the adaptive cardio volume mode was activated, which automatically switches from a one-segment to a two-segment scan (two segments from consecutive heart cycles that together provide data of a 180° rotation are used for slice reconstruction). Depending on the patient’s heart rate, a maximum temporal resolution of 83 ms can be achieved (8,9). Using retrospective electrocardiographic gating, we performed routinely reconstructions at 500, 600, and 700 ms before the R-wave (10). Because of motion artifacts at these reconstructions, additional reconstructions at 300, 400, and 550 ms were performed in six patients.

Image analysis of 64-slice CT.   The CT data set was analyzed by two independent experienced readers using the INSIGHT (Neoimagery Co., City of Industry, California) and the Leonardo (Siemens, Forchheim, Germany) software packages. In a first step, image quality was determined by the investigators on the basis of the presence of motion artifacts and on the basis of the contrast-to-noise ratio, as described in previous studies (11).

The grading criteria for image quality were as follows: A high-quality image was defined as no motion artifacts and a contrast-to-noise ratio of >8; a moderate-quality image was defined as motion artifacts present but the vessel still evaluable or a contrast-to-noise ratio between 4 and 8; and a poor-quality image was defined as motion artifacts present that made vessel delineation impossible or a contrast-to-noise ratio <4. Only patients who had high- and moderate-quality images of all coronary segments were considered for further analysis.

Any discernible structure that could be assigned to the coronary artery wall, that had a CT density less than the contrast-enhanced coronary lumen but greater than the surrounding connective tissue, and that could be identified in at least two independent planes was defined as a noncalcified coronary atherosclerotic plaque. Any structure with a density of 130 HU or more that could be visualized separately from the contrast-enhanced coronary lumen (either because it was "embedded" within noncalcified plaque or because its density was above the contrast-enhanced lumen), that could be assigned to the coronary artery wall, and that could be identified in at least two independent planes was defined as a calcified atherosclerotic plaque (12).

The display setting used for lumen and plaque quantification was determined empirically in a subset of six patients (recruited from the cohort of patients in whom IVUS was performed). In each patient, four different coronary sites that were easy to identify because of their location next to landmarks were selected. The image display setting at each site was then manipulated so that the multislice computed tomographic (MSCT) image equaled the IVUS image in size and pattern and allowed exact separation between vessel, surrounding tissue, plaque, and lumen. The values for window width and window level of the respective section were recorded and were set in relation to the mean intensity within the lumen at the corresponding site. The results of this analysis revealed that the optimal setting to detect plaque and outer vessel boundaries is obtained on average at a width representing 155% (range, 395 to 809 HU) of the mean intensity within the lumen and at a level representing 65% of the mean intensity (range, 165 to 339 HU). Keeping the window level (65% of mean intensity within the corresponding lumen) and reducing the width to a HU value of one, measurements provided optimal matching with IVUS (Fig. 1). Those initial measurements were performed by an independent investigator who was not involved in the later comparative analysis.



View larger version (133K):
[in this window]
[in a new window]
 
Figure 1 Angiographically nonobstructive lesion of the left anterior descending artery. (A) Invasive angiogram: arrow indicates a nonobstructive smooth lesion. (B) 64-slice computed tomography: arrowheads indicate a noncalcified plaque in the left anterior descending artery. (C) Intravascular ultrasound: longitudinal reconstruction. (D) Intravascular ultrasound cross section: lumen area 4 mm2, plaque area 11 mm2. (E) Cross-sectional view of the coronary vessel. (F) Window setting for lumen measurements: width is reduced to 1 HU, window level is set to 65% (210 HU in this case) of the mean intensity measured in the lumen. (G) Window level to determine outer vessel boundaries (width at 155% of mean value within the lumen, level at 65% of mean value). Lumen area is 4 mm2, plaque area is 1 mm2.

 
For comparison with quantitative coronary angiography (QCA), the grade of diameter stenosis (maximum diameter reduction) was determined in longitudinal curved multiplanar reformatted reconstructions by dividing the minimal diameter in the diseased segment through the diameter in the adjacent proximal disease-free section in the same two projections that were used for QCA. For comparison with IVUS, the percent area stenosis as well as plaque and vessel areas were determined in the cross sections of the coronaries using thin maximum intensity projections (Fig. 2).



View larger version (128K):
[in this window]
[in a new window]
 
Figure 2 Correlation of quantitative coronary angiography (QCA) and 64-slice computed tomography (CT) angiography: Visualization and quantification of a high-grade stenosis in the left circumflex artery. (Diameter in the reference section 3.1 mm on QCA, 3.0 mm on 64-slice CT; minimal diameter within the stenotic section 0.6 mm on QCA, 0.5 mm on 64-slice CT). (A) Invasive coronary angiogram of the left coronary artery (right anterior oblique projection). (B) Multiplanar reformatted projection of the left circumflex artery by 64-slice CT.

 
Catheter-based coronary angiography and IVUS.   Invasive coronary angiograms were evaluated by QCA (QuantCor QCA, Siemens Medical Systems, Forchheim, Germany) by an independent, blinded investigator. For coronary artery lesions, the mean diameter reduction was determined in two projections. In 18 patients, the IVUS of 32 coronary arteries was performed as part of the invasive diagnostic procedure (motorized pullback at 0.5 mm/s, electronic 20-MHz eagle view transducer, Volcano Therapeutics, Rancho Cordova, California). For each detectable lesion, the external elastic membrane cross-sectional area (EEM CSA) and the plaque area, defined as lumen CSA subtracted from EEM CSA, was defined by another independent investigator. Those measurements were performed in accordance to the IVUS interpretation guidelines of the American College of Cardiology and the American Heart Association (13).

Comparison of QCA with MSCT.   The determination of the diagnostic accuracy of 64-slice CT was performed for lesions with various degrees of luminal narrowing. We calculated sensitivity and specificity for lesions causing stenoses >75%, for stenoses >50%, and for stenoses <50%. Calculations for sensitivity and specificity were conducted on a segmental basis according to the American Heart Association’s segment model (15 segments) (1). Furthermore, we correlated measurements for stenosis severity obtained by 64-slice CT to QCA using the Spearman rank correlation.

Comparison of IVUS versus MSCT.   We performed IVUS in 32 coronary arteries without significant coronary stenoses of >50% on conventional angiography. The comparison with IVUS was based on a site-by-site basis if single plaques could easily be distinguished as the result of a disease-free section of at least 10 mm between them. In the case that a single plaque involved the entire segment or even more segments, the comparison was performed on a segmental basis. Sections without evidence of atherosclerosis were divided into 10-mm intervals. The site and the longitudinal extent of coronary plaques were determined on the basis of their distance to the ostium and on the basis of fiduciary points like side branches or severe calcifications. For each plaque, the maximum EEM CSA, the maximum plaque area, as well as the maximum percent luminal obstruction were determined.

Statistics.   The diagnostic accuracy of 64-slice CT to detect coronary lesions with various degrees of luminal obstruction was evaluated regarding QCA as the standard of reference. Sensitivity and specificity were calculated for stenosis >75%, for stenosis >50%, and for lesions <50% diameter reduction. Furthermore, we separately determined the accuracy for extensively calcified lesions (calcium area >50% of vessel area), for noncalcified or moderately calcified lesions (calcium area <50% of vessel area), and for lesions that were later targeted for a revascularization procedure (e.g., angioplasty or bypass surgery).

The capability of 64-slice CT to detect and quantify coronary plaques was further compared with IVUS. Sensitivity and specificity were calculated on a plaque-per-plaque basis and were given for different coronary vessels. Sections without atherosclerosis were divided in 10-mm sections and were the basis for specificity calculations. Correlations of EEM CSA, lumen CSA, and plaque CSA, as well as percent vessel obstruction (comparison with IVUS) and diameter stenosis (comparison with QCA) were determined by calculating the Spearman rank correlation coefficient. Mean values were compared using the double-tailed t test. A p value <0.05 was considered to be statistically significant. All calculations were performed using the NCSS 2000 software package (NCSS, Kaysville, Utah).


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
According to the inclusion criteria, contrast-enhanced 64-slice CT was performed successfully without any complications in 59 patients (age, 64 ± 10 years) that were scheduled for conventional invasive coronary angiography. Beta-blockers were administered in 21 patients to reduce their heart rate. The mean heart rate during the scan was 62 ± 13 beats/min.

Four of 59 patients had CT angiograms that were severely affected by motion artifacts (n = 2) or poor contrast-to-noise ratio (n = 2), making an evaluation of all coronary segments impossible. The heart rates of these four patients were 63, 72, 82, and 89 beats/min. In the remaining 55 patients, all coronary segments were graded to provide good or intermediate image quality that was sufficient for evaluation. Nine patients had heart rates >70 beats/min during the investigation, and diagnostic image quality was obtained in six of them.

A comparison between 64-slice CT and QCA was theoretically available in 825 segments from 55 patients. Because of an occlusion of 4 vessels (right coronary artery [RCA], n = 2; left anterior descending artery [LAD], n = 2), 14 distally located segments were not available for comparison. Furthermore, we performed a separate analysis for 13 segments containing a stent. The values for diagnostic accuracy of 64-slice CT to detect coronary stenosis with increasing degrees of luminal narrowing thus were based on 798 comparable segments and are given in Table 1.


View this table:
[in this window]
[in a new window]
 
Table 1. Accuracy of 64-Slice CT to Detect Coronary Stenosis in Comparison to QCA
 
Table 2 compares the classification of lesions derived from 64-slice CT and QCA (798 segments). Consensus in classifying the degree of coronary stenosis with both methods was achieved in 90 of 141 angiographically stenotic segments and in 638 of 657 disease-free segments. Overall, 20 lesions could not be visualized and 12 lesions were underestimated by 64-slice CT, 19 segments were incorrectly graded stenotic, and in 19 segments a present lesion was overestimated. Of seven stenoses >75% that were missed, five were detected but underestimated and two could not be visualized as a result of their location in a side branch (Table 2). Nineteen segments without evidence of atherosclerosis on QCA were graded stenotic on 64-slice CT. A comparison with IVUS was able to be performed in five of these segments, which confirmed the presence of atherosclerotic plaque in all five segments. All segments that were incorrectly classified as >75% stenotic (n = 11) were either distal segments (n = 5) or revealed extensive calcifications (n = 6; IVUS comparison available in one segment confirming calcified plaque).


View this table:
[in this window]
[in a new window]
 
Table 2. Consensus Table of Stenosis Severity Determined by 64-Slice CT Versus QCA
 
On a patient basis (patients without a stent, n = 45) 22 of 25 (sensitivity 88%) patients with at least one stenosis >50% on QCA were correctly identified, and in 17 of 20 patients, a stenosis >75% (85%) was correctly ruled out. If considering only patients with stenosis that subsequently required either angioplasty or bypass surgery, 17 of 18 patients (sensitivity 94%) were correctly identified by 64-slice CT. Overall correlation between the degree of stenosis detected by QCA compared with 64-slice CT was r = 0.54 using the Spearman rank correlation coefficient (Fig. 3).



View larger version (17K):
[in this window]
[in a new window]
 
Figure 3 Correlation of quantitative coronary angiography (QCA) and 64-slice computed tomography (CT) measurements of diameter stenosis in diseased coronary segments. Pearson’s correlation coefficient r = 0.54.

 
We were able to compare 64-slice CT and QCA in 13 segments containing a stent. Two of two stents with an in-stent restenosis >75% were correctly classified by 64-slice CT. Two of two in-stent stenoses <75% were missed and, in four of nine stents without any restenosis, a restenosis >50% was diagnosed by 64-slice CT.

Intravascular ultrasound was part of the invasive catheterization procedure in 18 patients and was performed in 32 coronary vessels (left main and LAD, n = 16; left circumflex artery [LCX], n = 14; RCA, n = 2). No stents were investigated by IVUS. The results for diagnostic accuracy of 64-slice CT to detect coronary plaques in these vessels, based on a site-by-site analysis, are given in Table 3. Overall, 55 coronary plaques were detected on IVUS, and 64-slice CT identified 46 of them (sensitivity 84%); in 39 of 43 disease-free 10-mm sections, the presence of plaque was correctly excluded (specificity 91%; Table 3).


View this table:
[in this window]
[in a new window]
 
Table 3. Accuracy of 64-Slice CT to Detect Coronary Lesions in Comparison to IVUS
 
The mean plaque CSA, the mean lumen CSA, the mean EEM CAS, and the percent vessel obstruction (% plaque of EEM CSA) determined by IVUS and 64-slice CT were 8.1 ± 3.8 mm2 versus 7.3 ± 5.1 mm2 (p < 0.04), 8.4 ± 4.5 mm2 versus 9.4 ± 5.1 mm2 (p < 0.01), 16.4 ± 5.8 mm2 versus 16.7 ± 7.1 mm2 (p = 0.6, NS), and 50.4 ± 14.0% versus 41.1 ± 22.7% (p < 0.001). The correlation coefficients for these measurements were r = 0.73, r = 0.81, r = 0.88, and r = 0.61, respectively (Fig. 4).



View larger version (15K):
[in this window]
[in a new window]
 
Figure 4 Correlation of the percentage of plaque area contributing to entire vessel area (ratio of plaque area to the external elastic membrane [EEM] cross-sectional area [CSA]) determined by intravascular ultrasound (IVUS) and 64-slice computed tomography (CT). The correlation coefficient between the measurements with both methods is r = 0.61. On average, the percentage of vessel area occupied by plaque is significantly underestimated by 64-slice computed tomography (50.4% vs. 41.1%, p < 0.001).

 

    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
In recent publications using 16-slice CT scanners, remarkable results identifying high-grade coronary stenoses were found, although this technology is still affected by several limitations explained by the given spatial and temporal resolution (1,3,7). Those limitations probably contributed to the fact that all existing studies focused on the detection of high-grade stenosis only and, until now, no attempt was directed toward a CT-derived stenosis quantification. In the present study, we used a new generation 64-slice CT with improved spatial and temporal resolution, and we demonstrated that this technology was feasible in identifying obstructive and nonobstructive coronary lesions with high accuracy in major parts of all three coronaries. Furthermore, we found a good correlation to determine plaque areas compared with IVUS. However, the ability to quantify the grade of luminal obstruction is limited.

Clinical feasibility.   Previous MSCT studies revealed that its clinical feasibility mainly is limited by motion artifacts that occurred in patients with heart rates >65 beats/min. Therefore, in most studies CT angiography was performed exclusively in subjects with lower heart rates (1,3). In a recent report, we demonstrated that by administering a beta-blocker, a satisfactory heart rate reduction could only achieved in 80% of patients and that, even in these patients, 10% of CT studies were affected by motion artifacts (7). In the present study, using a scanner with a temporal resolution of 83 to 165 ms, we investigated all patients irrespective of the heart rate (although in 21 of 59 patients a beta-blocker was administered) and we found that complete, assessable CT angiograms were obtained in 55 of 59 patients. When considering only patients with heart rates >70 beats/min, six of nine patients still exhibited diagnostic image quality of all coronary arteries. Compared with 4-slice CT and 16-slice CT investigations, this constitutes a major improvement and is not only explained by improved acquisition time but also by the fact that the entire scan time is significantly shortened to only 8 to 11 s, making this technology more robust against respiratory and motion artifacts of the patient. However, heart rate control by negative chronotropic agents seems still to be reasonable, even with a temporal resolution of 83 to 165 ms.

Diagnostic accuracy of 64-slice CT in detecting angiographically stenotic lesions.   In the case of diagnostic image quality, even with 4-slice and 16-slice CT scanners, high sensitivities and specifities were achieved in several independent investigations on various patient populations. However, those studies exclusively aimed to detect high-grade coronary stenosis predominantly in coronary segments with a diameter of at least 2 mm (2–5). The present study was designed to determine the accuracy of 64-slice CT without excluding distal coronary segments and side branches. In the only existing 16-slice CT study that investigated all coronary segments, an overall sensitivity of 63% to detect high-grade stenoses was reported (14) and, thus, our results, demonstrating a sensitivity of 75% (57 of 75 of >50% stenosis), reveal that 64-slice CT may be superior to this technology.

In major segments of the LAD and the RCA, as well as in the proximal part of the LCX, we found an excellent accuracy to detect all degrees of stenosis. Therefore, 24 of 27 (89%) lesions and 94% of patients that later required angioplasty or bypass surgery were identified correctly by 64-slice CT. However, in the distal segments of the LCX (segment 13), the marginal branches (segments 12, 14, and 15) and the LAD (segment 8), sufficient accuracy could not be obtained in most cases, indicating that spatial resolution even with this scanner technology still is not high enough to identify stenosis in peripheral segments. However, distal lesions are rarely a target for an intervention. Similar to 4-slice CT and 16-slice CT, extensive calcifications are a frequent source for missclassifications even with 64 slice CT (Table 1), although the degree of artifacts due to partial volume effects seem to be less severe.

The noninvasive follow-up of coronary stents is a desireable goal, and it is already speculated that 64-slice CT scanners may enable the visualization of in-stent restenosis (15). However, the dense stent material and the resulting artifacts still prevent a correct assessment of the in-stent lumen and, therefore, 6 of 13 stents were missclassified in the present study. Because a comparison only was available in a small number of stents and because we did not use sharper kernel reconstructions that may have improved stent evaluation by 64-slice CT, larger studies are needed to evaluate the true ability of 64-slice CT to assess different types of coronary stents.

Use of 64-slice CT to detect intermediate and nonstenotic coronary lesions (<50% luminal stenosis).   Because angiography only allows imaging of the lumen contour of coronary vessels and provides no information concerning the vessel wall, plaque size or compensatory vessel remodelling, IVUS and not angiography is the reference standard for the detection of nonobstructive lesions and for quantitative measurements of lumen size and plaque size.

Furthermore, IVUS also is superior in determining luminal obstruction, especially in the presence of intermediate stenosis (13,16,17). Therefore, we performed a comparison of IVUS and CT in a subset of patients. This comparison revealed the high accuracy of 64-slice CT in identifying coronary lesions in vessels without significant stenosis (>50%) on angiography.

For CT-derived measurements of lumen and plaque, the image display setting may have important influence. Funabashi et al. (18) demonstrated that individually adapted settings that were related to peak attenuation within the vessel lumen are superior to standardized fixed settings (18). Therefore, the measurements in the present study were based on an empirically calculated formula determining the optimal image display settings dependent on the respective lumen attenuation. By using these window settings, a correlation to IVUS was good for lumen and plaque areas but only moderate for percent vessel obstruction because of a significant trend to overestimate lumen areas and underestimate plaque areas. This observation is explained by partial volume effects occurring at the lumen/plaque border either caused by calcium or the dense contrast agent and by the fact that density values of opacified lumen and plaque may overlap in a certain range. In contrast to the latter, partial volume effects will be diminished by scanners with further increased spatial resolution.

Study limitations.   The findings of the present study document that 64-slice CT is a clinically suitable and robust noninvasive method to detect and quantify obstructive and nonobstructive coronary disease, although the quantification of luminal obstruction is limited because of technical restrictions. Therefore, this new technique may improve the noninvasive workup of symptomatic and probably even asymptomatic patients in terms of stenosis detection and risk stratification.

The results are influenced by the relatively high prevalence of coronary artery disease in our patient cohort. Thus, sensitivity and specificity values may differ in asymptomatic subjects with a lower prevalence of atherosclerosis. Most patients scheduled for catheterization at our hospital present at the same day of the procedure, leaving no time for a CT scan. Therefore, we investigated only patients that were available for a CT scan at least one day before the invasive angiogram. This fact also explains the low number of consecutive patients recruited during a four-month period.


    Footnotes
 
Both Drs. Leber and Knez contributed equally to this study.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
1. Kuettner A, Kopp AF, Schroeder S, et al. Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery disease J Am Coll Cardiol 2004;43:831-839.[Abstract/Free Full Text]

2. Kuettner A, Trabold T, Schroeder S, et al. Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technologyinitial clinical results. J Am Coll Cardiol 2004;44:1230-1237.[Abstract/Free Full Text]

3. Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction Circulation 2003;107:664-666.[Abstract/Free Full Text]

4. Mollet NR, Cademartiri F, Nieman K, et al. Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris J Am Coll Cardiol 2004;43:2265-2270.[Abstract/Free Full Text]

5. Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography Circulation 2002;106:2051-2054.[Abstract/Free Full Text]

6. Nieman K, Oudkerk M, Rensing BJ, et al. Coronary angiography with multi-slice computed tomography Lancet 2001;357:599-603.[CrossRef][Web of Science][Medline]

7. Leber AW, Knez A, Becker A, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaquesa comparative study with intracoronary ultrasound. J Am Coll Cardiol 2004;43:1241-1247.[Abstract/Free Full Text]

8. Flohr T, Stierstorfer K, Raupach R, Ulzheimer S, Bruder H. Performance evaluation of a 64-slice CT system with z-flying focal spot Rofo 2004;176:1803-1810.[Web of Science][Medline]

9. Flohr T, Ohnesorge B. Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart J Comput Assist Tomogr 2001;25:907-923.[CrossRef][Web of Science][Medline]

10. Flohr T, Prokop M, Becker C, et al. A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage Eur Radiol 2002;12:1497-1503.[CrossRef][Web of Science][Medline]

11. Leber AW, Knez A, Becker C, et al. Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography Heart 2003;89:633-639.[Abstract/Free Full Text]

12. Achenbach S, Ropers D, Hoffmann U, et al. Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography J Am Coll Cardiol 2004;43:842-847.[Abstract/Free Full Text]

13. Mintz GS, Nissen SE, Anderson WD, et al. American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents J Am Coll Cardiol 2001;37:1478-1492.[Free Full Text]

14. Hoffmann U, Moselewski F, Cury RC, et al. Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery diseasepatient-versus segment-based analysis. Circulation 2004;110:2638-2643.[Abstract/Free Full Text]

15. Mollet NR, Cademartiri F. Images in cardiovascular medicine. In-stent neointimal hyperplasia with 16-row multislice computed tomography coronary angiography Circulation 2004;110:e514.[Free Full Text]

16. Nissen SE. Application of intravascular ultrasound to characterize coronary artery disease and assess the progression or regression of atherosclerosis Am J Cardiol 2002;89:24B-31B.[CrossRef][Web of Science][Medline]

17. Schoenhagen P, White RD, Nissen SE, Tuzcu EM. Coronary imagingangiography shows the stenosis, but IVUS, CT, and MRI show the plaque. Cleve Clin J Med 2003;70:713-719.[Abstract/Free Full Text]

18. Funabashi N, Kobayashi Y, Kudo M, et al. New method of measuring coronary diameter by electron-beam computed tomographic angiography using adjusted thresholds determined by calibration with aortic opacity Circ J 2004;68:769-777.[CrossRef][Medline]


Related Article

Computed Tomography of the Coronary Arteries: More Than Meets the (Angiographic) Eye
Stephan Achenbach and Werner G. Daniel
J. Am. Coll. Cardiol. 2005 46: 155-157. [Full Text] [PDF]



This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
D Schnapauff, F Teige, B Hamm, and M Dewey
Comparison between the image quality of multisegment and halfscan reconstructions of non-invasive CT coronary angiography
Br. J. Radiol., December 1, 2009; 82(984): 969 - 975.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B A Herzog, C A Wyss, L Husmann, O Gaemperli, I Valenta, V Treyer, U Landmesser, and P A Kaufmann
First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography
Heart, October 15, 2009; 95(20): 1656 - 1661.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H BRODOEFEL, C BURGSTAHLER, M HEUSCHMID, A REIMANN, F KHOSA, A KOPP, S SCHROEDER, C D CLAUSSEN, and M E CLOUSE
Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound
Br. J. Radiol., October 1, 2009; 82(982): 805 - 812.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Baumuller, S. Leschka, L. Desbiolles, P. Stolzmann, H. Scheffel, B. Seifert, B. Marincek, and H. Alkadhi
Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation Dose
Radiology, October 1, 2009; 253(1): 56 - 64.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
T. Knickelbine, J. R. Lesser, T. S. Haas, E. R. Brandenburg, B. K. Gleason-Han, B. Flygenring, T. F. Longe, R. S. Schwartz, and B. J. Maron
Identification of Unexpected Nonatherosclerotic Cardiovascular Disease With Coronary CT Angiography
J. Am. Coll. Cardiol. Img., September 1, 2009; 2(9): 1085 - 1092.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
J. M. Hartman, B. W. Meijboom, T. W. Galema, J. J.M. Takkenberg, A.-M. Schets, P. J. de Feyter, and A. J.J.C. Bogers
Anatomical and functional assessment of single left internal mammary artery versus arterial T-grafts 12 years after surgery
Interactive CardioVascular and Thoracic Surgery, September 1, 2009; 9(3): 416 - 420.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Yang, Z. Zhang, Z. Fan, C. Xu, L. Zhao, W. Yu, and Z. Yan
64-MDCT Coronary Angiography of Patients With Atrial Fibrillation: Influence of Heart Rate on Image Quality and Efficacy in Evaluation of Coronary Artery Disease
Am. J. Roentgenol., September 1, 2009; 193(3): 795 - 801.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. J. Chen, M. A. Manning, A. A. Frazier, J. Jeudy, and C. S. White
CT Angiography of the Cardiac Valves: Normal, Diseased, and Postoperative Appearances
RadioGraphics, September 1, 2009; 29(5): 1393 - 1412.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
B. Bischoff, F. Hein, T. Meyer, M. Hadamitzky, S. Martinoff, A. Schomig, and J. Hausleiter
Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose: Results of the PROTECTION I Study
J. Am. Coll. Cardiol. Img., August 1, 2009; 2(8): 940 - 946.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
L HUSMANN, O GAEMPERLI, I VALENTA, T SCHEPIS, H SCHEFFEL, P STOLZMANN, S LESCHKA, L DESBIOLLES, B MARINCEK, H ALKADHI, et al.
Impact of vessel attenuation on quantitative coronary angiography with 64-slice CT
Br. J. Radiol., August 1, 2009; 82(980): 649 - 653.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
J. H.F. Rudd, F. Hyafil, and Z. A. Fayad
Inflammation Imaging in Atherosclerosis
Arterioscler Thromb Vasc Biol, July 1, 2009; 29(7): 1009 - 1016.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
G. Sarno, I. Decraemer, P. K. Vanhoenacker, B. De Bruyne, M. Hamilos, T. Cuisset, E. Wyffels, J. Bartunek, G. R. Heyndrickx, and W. Wijns
On the Inappropriateness of Noninvasive Multidetector Computed Tomography Coronary Angiography to Trigger Coronary Revascularization: A Comparison With Invasive Angiography
J. Am. Coll. Cardiol. Intv., June 1, 2009; 2(6): 550 - 557.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
D. S. Berman and J. K. Min
Can Coronary Computed Tomographic Angiography Trigger Coronary Revascularization?: Questioning the Appropriateness of the Question
J. Am. Coll. Cardiol. Intv., June 1, 2009; 2(6): 558 - 560.
[Full Text] [PDF]


Home page
JNMHome page
F. Hyafil, J.-C. Cornily, J. H.F. Rudd, J. Machac, L. J. Feldman, and Z. A. Fayad
Quantification of Inflammation Within Rabbit Atherosclerotic Plaques Using the Macrophage-Specific CT Contrast Agent N1177: A Comparison with 18F-FDG PET/CT and Histology
J. Nucl. Med., June 1, 2009; 50(6): 959 - 965.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
U. Hoffmann, F. Bamberg, C. U. Chae, J. H. Nichols, I. S. Rogers, S. K. Seneviratne, Q. A. Truong, R. C. Cury, S. Abbara, M. D. Shapiro, et al.
Coronary computed tomography angiography for early triage of patients with acute chest pain: the ROMICAT (Rule Out Myocardial Infarction using Computer Assisted Tomography) trial.
J. Am. Coll. Cardiol., May 5, 2009; 53(18): 1642 - 1650.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Pugliese, M. G. M. Hunink, K. Gruszczynska, F. Alberghina, R. Malago, N. van Pelt, N. R. Mollet, F. Cademartiri, A. C. Weustink, W. B. Meijboom, et al.
Learning Curve for Coronary CT Angiography: What Constitutes Sufficient Training?
Radiology, May 1, 2009; 251(2): 359 - 368.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
M. Greif, A. Becker, F. von Ziegler, C. Lebherz, M. Lehrke, U. C. Broedl, J. Tittus, K. Parhofer, C. Becker, M. Reiser, et al.
Pericardial Adipose Tissue Determined by Dual Source CT Is a Risk Factor for Coronary Atherosclerosis
Arterioscler Thromb Vasc Biol, May 1, 2009; 29(5): 781 - 786.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Pflederer, L. Rudofsky, D. Ropers, S. Bachmann, M. Marwan, W. G. Daniel, and S. Achenbach
Image Quality in a Low Radiation Exposure Protocol for Retrospectively ECG-Gated Coronary CT Angiography
Am. J. Roentgenol., April 1, 2009; 192(4): 1045 - 1050.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, B. A. Herzog, O. Gaemperli, F. Tatsugami, N. Burkhard, I. Valenta, P. Veit-Haibach, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating
Eur. Heart J., March 1, 2009; 30(5): 600 - 607.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Brodoefel, C. Burgstahler, A. Sabir, C.-S. Yam, F. Khosa, C. D. Claussen, and M. E. Clouse
Coronary Plaque Quantification by Voxel Analysis: Dual-Source MDCT Angiography Versus Intravascular Sonography
Am. J. Roentgenol., March 1, 2009; 192(3): W84 - W89.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
B. J.W. Chow, A. Abraham, G. A. Wells, L. Chen, T. D. Ruddy, Y. Yam, N. Govas, P. D. Galbraith, C. Dennie, and R. S. Beanlands
Diagnostic Accuracy and Impact of Computed Tomographic Coronary Angiography on Utilization of Invasive Coronary Angiography
Circ Cardiovasc Imaging, January 1, 2009; 2(1): 16 - 23.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, M. F.L. Meijs, J. D. Schuijf, M. J. Cramer, N. R. Mollet, C. A.G. van Mieghem, K. Nieman, J. M. van Werkhoven, G. Pundziute, A. C. Weustink, et al.
Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study.
J. Am. Coll. Cardiol., December 16, 2008; 52(25): 2135 - 2144.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
B. A. Herzog, L. Husmann, N. Burkhard, O. Gaemperli, I. Valenta, F. Tatsugami, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
Eur. Heart J., December 2, 2008; 29(24): 3037 - 3042.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Matsumoto, T. Kondo, S. Watanabe, R. Kikumoto, T. Shimada, Y. Hiraoka, and K. Ueda
ECG-Edited Middiastolic Phase Reconstruction Improves Image Quality at 64-MDCT Coronary Angiography of Patients with Atrial Fibrillation
Am. J. Roentgenol., December 1, 2008; 191(6): 1659 - 1666.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
U. Elkayam, M. W. Akhter, M. Liu, P. Hatamizadeh, and M. N. Barakat
Assessment of renal hemodynamic effects of nesiritide in patients with heart failure using intravascular Doppler and quantitative angiography.
J. Am. Coll. Cardiol. Img., November 1, 2008; 1(6): 765 - 771.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
R. J. Gibbons
Noninvasive Diagnosis and Prognosis Assessment in Chronic Coronary Artery Disease: Stress Testing With and Without Imaging Perspective
Circ Cardiovasc Imaging, November 1, 2008; 1(3): 257 - 269.
[Full Text] [PDF]


Home page
HeartHome page
G Mowatt, J A Cook, G S Hillis, S Walker, C Fraser, X Jia, and N Waugh
64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis
Heart, November 1, 2008; 94(11): 1386 - 1393.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Maruyama, M. Takada, T. Hasuike, A. Yoshikawa, E. Namimatsu, and T. Yoshizumi
Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography: Comparison With Retrospective Electrocardiogram-Gated Helical Scan
J. Am. Coll. Cardiol., October 28, 2008; 52(18): 1450 - 1455.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Sarwar, J. Rieber, E. A. Q. Mooyaart, S. K. Seneviratne, S. L. Houser, F. Bamberg, O. C. Raffel, R. Gupta, M. K. Kalra, H. Pien, et al.
Calcified Plaque: Measurement of Area at Thin-Section Flat-Panel CT and 64-Section Multidetector CT and Comparison with Histopathologic Findings
Radiology, October 1, 2008; 249(1): 301 - 306.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Ghostine, C. Caussin, M. Habis, Y. Habib, C. Clement, A. Sigal-Cinqualbre, C.-Y. Angel, B. Lancelin, A. Capderou, and J.-F. Paul
Non-invasive diagnosis of ischaemic heart failure using 64-slice computed tomography
Eur. Heart J., September 1, 2008; 29(17): 2133 - 2140.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Leschka, H Scheffel, L Desbiolles, A Plass, O Gaemperli, P Stolzmann, M Genoni, T Luescher, B Marincek, P Kaufmann, et al.
Combining dual-source computed tomography coronary angiography and calcium scoring: added value for the assessment of coronary artery disease
Heart, September 1, 2008; 94(9): 1154 - 1161.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, C. A.G. Van Mieghem, N. van Pelt, A. Weustink, F. Pugliese, N. R. Mollet, E. Boersma, E. Regar, R. J. van Geuns, P. J. de Jaegere, et al.
Comprehensive Assessment of Coronary Artery Stenoses: Computed Tomography Coronary Angiography Versus Conventional Coronary Angiography and Correlation With Fractional Flow Reserve in Patients With Stable Angina
J. Am. Coll. Cardiol., August 19, 2008; 52(8): 636 - 643.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. D. Dodd, J. Rieber, E. Pomerantsev, V. Chaithiraphan, S. Achenbach, J. M. Moreiras, S. Abbara, U. Hoffmann, T. J. Brady, and R. C. Cury
Quantification of Nonculprit Coronary Lesions: Comparison of Cardiac 64-MDCT and Invasive Coronary Angiography
Am. J. Roentgenol., August 1, 2008; 191(2): 432 - 438.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Bastarrika, C. N. De Cecco, M. Arraiza, S. Mastrobuoni, J. C. Pueyo, M. Ubilla, and G. Rabago
Dual-Source CT for Visualization of the Coronary Arteries in Heart Transplant Patients with High Heart Rates
Am. J. Roentgenol., August 1, 2008; 191(2): 448 - 454.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. C. Cury, K. Nieman, M. D. Shapiro, J. Butler, C. H. Nomura, M. Ferencik, U. Hoffmann, S. Abbara, D. S. Jassal, T. Yasuda, et al.
Comprehensive Assessment of Myocardial Perfusion Defects, Regional Wall Motion, and Left Ventricular Function by Using 64-Section Multidetector CT
Radiology, August 1, 2008; 248(2): 466 - 475.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. Gaemperli, T. Schepis, I. Valenta, P. Koepfli, L. Husmann, H. Scheffel, S. Leschka, F. R. Eberli, T. F. Luscher, H. Alkadhi, et al.
Functionally Relevant Coronary Artery Disease: Comparison of 64-Section CT Angiography with Myocardial Perfusion SPECT
Radiology, August 1, 2008; 248(2): 414 - 423.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, et al.
Noninvasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young
Circulation, July 29, 2008; 118(5): 586 - 606.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
V. Cheng, A. Gutstein, A. Wolak, Y. Suzuki, D. Dey, H. Gransar, L. E.J. Thomson, S. W. Hayes, J. D. Friedman, and D. S. Berman
Moving beyond binary grading of coronary arterial stenoses on coronary computed tomographic angiography insights for the imager and referring clinician.
J. Am. Coll. Cardiol. Img., July 1, 2008; 1(4): 460 - 471.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
X. Fei, X. Du, Q. Yang, Y. Shen, P. Li, J. Liao, and K. Li
64-MDCT Coronary Angiography: Phantom Study of Effects of Vascular Attenuation on Detection of Coronary Stenosis
Am. J. Roentgenol., July 1, 2008; 191(1): 43 - 49.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. L. Kelly, D. Thickman, S. D. Abramson, P. R. Chen, S. F. Smazal, M. J. Fleishman, and S. C. Lingam
Coronary CT Angiography Findings in Patients Without Coronary Calcification
Am. J. Roentgenol., July 1, 2008; 191(1): 50 - 55.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
F Pugliese, A C Weustink, C Van Mieghem, F Alberghina, M Otsuka, W B Meijboom, N van Pelt, N R Mollet, F Cademartiri, G P Krestin, et al.
Dual source coronary computed tomography angiography for detecting in-stent restenosis
Heart, July 1, 2008; 94(7): 848 - 854.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
W T Roberts, J J Bax, and L C Davies
Cardiac CT and CT coronary angiography: technology and application
Heart, June 1, 2008; 94(6): 781 - 792.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. E. Clouse, A. Sabir, C.-S. Yam, N. Yoshimura, S. Lin, F. Welty, P. Martinez-Clark, and V. Raptopoulos
Measuring Noncalcified Coronary Atherosclerotic Plaque Using Voxel Analysis with MDCT Angiography: A Pilot Clinical Study
Am. J. Roentgenol., June 1, 2008; 190(6): 1553 - 1560.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Leschka, H. Scheffel, L. Husmann, O. Gamperli, B. Marincek, P. A. Kaufmann, and H. Alkadhi
Effect of Decrease in Heart Rate Variability on the Diagnostic Accuracy of 64-MDCT Coronary Angiography
Am. J. Roentgenol., June 1, 2008; 190(6): 1583 - 1590.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Brodoefel, C. Burgstahler, I. Tsiflikas, A. Reimann, S. Schroeder, C. D. Claussen, M. Heuschmid, and A. F. Kopp
Dual-Source CT: Effect of Heart Rate, Heart Rate Variability, and Calcification on Image Quality and Diagnostic Accuracy
Radiology, May 1, 2008; 247(2): 346 - 355.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. S. Bedi, J. A. S. Gill, and S. S. Bakshi
Can we perform coronary artery bypass grafting on the basis of computed tomographic angiography alone? A comparison with conventional coronary angiography
Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 633 - 638.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Sato, M. Hiroe, M. Tamura, H. Ohigashi, T. Nozato, H. Hikita, A. Takahashi, K. Aonuma, and M. Isobe
Quantitative Measures of Coronary Stenosis Severity by 64-Slice CT Angiography and Relation to Physiologic Significance of Perfusion in Nonobese Patients: Comparison with Stress Myocardial Perfusion Imaging
J. Nucl. Med., April 1, 2008; 49(4): 564 - 572.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Sabir, C.-S. Yam, N. Yoshimura, J. L. Buros, A. M. De Grand, V. Raptopoulos, and M. E. Clouse
Measuring Noncalcified Coronary Atherosclerotic Plaque Using Voxel Analysis with MDCT Angiography: Phantom Validation
Am. J. Roentgenol., April 1, 2008; 190(4): W242 - W246.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. Gottlieb and J. A.C. Lima
Screening High-Risk Patients With Computed Tomography Angiography
Circulation, March 11, 2008; 117(10): 1318 - 1332.
[Full Text] [PDF]


Home page
CirculationHome page
C. M. Kramer
All High-Risk Patients Should Not Be Screened With Computed Tomographic Angiography
Circulation, March 11, 2008; 117(10): 1333 - 1339.
[Full Text] [PDF]


Home page
Eur Heart JHome page
H. Alkadhi, H. Scheffel, L. Desbiolles, O. Gaemperli, P. Stolzmann, A. Plass, G. W. Goerres, T. F. Luescher, M. Genoni, B. Marincek, et al.
Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
Eur. Heart J., March 2, 2008; 29(6): 766 - 776.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
S. Prat-Gonzalez, J. Sanz, and M. J. Garcia
Cardiac CT: Indications and Limitations
J. Nucl. Med. Technol., March 1, 2008; 36(1): 18 - 24.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Sun, Z. Zhang, B. Lu, W. Yu, Y. Yang, Y. Zhou, Y. Wang, and Z. Fan
Identification and Quantification of Coronary Atherosclerotic Plaques: A Comparison of 64-MDCT and Intravascular Ultrasound
Am. J. Roentgenol., March 1, 2008; 190(3): 748 - 754.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard
Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity
Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A J H A Scholte, J D Schuijf, A V Kharagjitsingh, J W Jukema, G Pundziute, E E van der Wall, and J J Bax
Prevalence of coronary artery disease and plaque morphology assessed by multi-slice computed tomography coronary angiography and calcium scoring in asymptomatic patients with type 2 diabetes
Heart, March 1, 2008; 94(3): 290 - 295.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al.
Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology
Eur. Heart J., February 2, 2008; 29(4): 531 - 556.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Horiguchi, M. Kiguchi, C. Fujioka, Y. Shen, R. Arie, K. Sunasaka, and K. Ito
Radiation Dose, Image Quality, Stenosis Measurement, and CT Densitometry Using ECG-Triggered Coronary 64-MDCT Angiography: A Phantom Study
Am. J. Roentgenol., February 1, 2008; 190(2): 315 - 320.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Pugliese, N. R. Mollet, M. G. M. Hunink, F. Cademartiri, K. Nieman, R. T. van Domburg, W. B. Meijboom, C. Van Mieghem, A. C. Weustink, M. L. Dijkshoorn, et al.
Diagnostic Performance of Coronary CT Angiography by Using Different Generations of Multisection Scanners: Single-Center Experience
Radiology, February 1, 2008; 246(2): 384 - 393.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Eur. Heart J., January 2, 2008; 29(2): 191 - 197.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
U. Ropers, D. Ropers, T. Pflederer, K. Anders, A. Kuettner, N. I. Stilianakis, S. Komatsu, W. Kalender, W. Bautz, W. G. Daniel, et al.
Influence of Heart Rate on the Diagnostic Accuracy of Dual-Source Computed Tomography Coronary Angiography
J. Am. Coll. Cardiol., December 18, 2007; 50(25): 2393 - 2398.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Hausleiter, T. Meyer, M. Hadamitzky, M. Zankl, P. Gerein, K. Dorrler, A. Kastrati, S. Martinoff, and A. Schomig
Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial
Eur. Heart J., December 2, 2007; 28(24): 3034 - 3041.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Abdulla, S. Z. Abildstrom, O. Gotzsche, E. Christensen, L. Kober, and C. Torp-Pedersen
64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis
Eur. Heart J., December 2, 2007; 28(24): 3042 - 3050.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. R. Simon, H. Baraki, J. Weidemann, W. Harringer, M. Galanski, and A. Haverich
High-resolution 64-slice helical-computer-assisted-tomographical-angiography as a diagnostic tool before CABG surgery: the dawn of a new era?
Eur. J. Cardiothorac. Surg., December 1, 2007; 32(6): 896 - 901.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Oncel, G. Oncel, and A. Tastan
Effectiveness of Dual-Source CT Coronary Angiography for the Evaluation of Coronary Artery Disease in Patients with Atrial Fibrillation: Initial Experience
Radiology, December 1, 2007; 245(3): 703 - 711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
X. Liu, X. Zhao, J. Huang, C. J. Francois, D. Tuite, X. Bi, D. Li, and J. C. Carr
Comparison of 3D Free-Breathing Coronary MR Angiography and 64-MDCT Angiography for Detection of Coronary Stenosis in Patients with High Calcium Scores
Am. J. Roentgenol., December 1, 2007; 189(6): 1326 - 1332.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
V Russo, V Gostoli, L Lovato, M Montalti, A Marzocchi, G Gavelli, A Branzi, R Di Bartolomeo, and R Fattori
Clinical value of multidetector CT coronary angiography as a preoperative screening test before non-coronary cardiac surgery
Heart, December 1, 2007; 93(12): 1591 - 1598.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Hamon, R. Morello, J. W. Riddell, and M. Hamon
Coronary Arteries: Diagnostic Performance of 16- versus 64-Section Spiral CT Compared with Invasive Coronary Angiography Meta-Analysis
Radiology, December 1, 2007; 245(3): 720 - 731.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
W. B Meijboom, N. R Mollet, C. A Van Mieghem, A. C Weustink, F. Pugliese, N. van Pelt, F. Cademartiri, E. Vourvouri, P. de Jaegere, G. P Krestin, et al.
64-Slice CT coronary angiography in patients with non-ST elevation acute coronary syndrome
Heart, November 1, 2007; 93(11): 1386 - 1392.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. Husmann, S. Leschka, L. Desbiolles, T. Schepis, O. Gaemperli, B. Seifert, P. Cattin, T. Frauenfelder, T. G. Flohr, B. Marincek, et al.
Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate Implications for CT Image Reconstruction
Radiology, November 1, 2007; 245(2): 567 - 576.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, C. A.G. van Mieghem, N. R. Mollet, F. Pugliese, A. C. Weustink, N. van Pelt, F. Cademartiri, K. Nieman, E. Boersma, P. de Jaegere, et al.
64-Slice Computed Tomography Coronary Angiography in Patients With High, Intermediate, or Low Pretest Probability of Significant Coronary Artery Disease
J. Am. Coll. Cardiol., October 9, 2007; 50(15): 1469 - 1475.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. Dewey, H.-P. Dubel, T. Schink, G. Baumann, and B. Hamm
Head-to-head comparison of multislice computed tomography and exercise electrocardiography for diagnosis of coronary artery disease
Eur. Heart J., October 2, 2007; 28(20): 2485 - 2490.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. W. Leber, T. Johnson, A. Becker, F. von Ziegler, J. Tittus, K. Nikolaou, M. Reiser, G. Steinbeck, C. R. Becker, and A. Knez
Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
Eur. Heart J., October 1, 2007; 28(19): 2354 - 2360.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Alkadhi, L. Desbiolles, L. Husmann, A. Plass, S. Leschka, H. Scheffel, R. Vachenauer, T. Schepis, O. Gaemperli, T. G. Flohr, et al.
Aortic Regurgitation: Assessment with 64-Section CT
Radiology, October 1, 2007; 245(1): 111 - 121.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. J. Einstein, K. W. Moser, R. C. Thompson, M. D. Cerqueira, and M. J. Henzlova
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Circulation, September 11, 2007; 116(11): 1290 - 1305.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Matt, H. Scheffel, S. Leschka, T. G. Flohr, B. Marincek, P. A. Kaufmann, and H. Alkadhi
Dual-Source CT Coronary Angiography: Image Quality, Mean Heart Rate, and Heart Rate Variability
Am. J. Roentgenol., September 1, 2007; 189(3): 567 - 573.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, A. de Roos, and J. Geleijns
Artifacts in ECG-Synchronized MDCT Coronary Angiography
Am. J. Roentgenol., September 1, 2007; 189(3): 581 - 591.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A.-C. Pouleur, J.-B. le Polain de Waroux, A. Pasquet, J.-L. J. Vanoverschelde, and B. L. Gerber
Aortic Valve Area Assessment: Multidetector CT Compared with Cine MR Imaging and Transthoracic and Transesophageal Echocardiography
Radiology, September 1, 2007; 244(3): 745 - 754.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. C. Weustink, W. B. Meijboom, N. R. Mollet, M. Otsuka, F. Pugliese, C. van Mieghem, R. Malago, N. van Pelt, M. L. Dijkshoorn, F. Cademartiri, et al.
Reliable High-Speed Coronary Computed Tomography in Symptomatic Patients
J. Am. Coll. Cardiol., August 21, 2007; 50(8): 786 - 794.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
C. A.G. Van Mieghem, A. Thury, W. B. Meijboom, F. Cademartiri, N. R. Mollet, A. C. Weustink, G. Sianos, P. P.T. de Jaegere, P. W. Serruys, and P. de Feyter
Detection and characterization of coronary bifurcation lesions with 64-slice computed tomography coronary angiography
Eur. Heart J., August 2, 2007; 28(16): 1968 - 1976.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Malagutti, K. Nieman, W. B. Meijboom, C. A.G. van Mieghem, F. Pugliese, F. Cademartiri, N. R. Mollet, E. Boersma, P. P. de Jaegere, and P. J. de Feyter
Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries
Eur. Heart J., August 1, 2007; 28(15): 1879 - 1885.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. K. Vanhoenacker, M. H. Heijenbrok-Kal, R. Van Heste, I. Decramer, L. R. Van Hoe, W. Wijns, and M. G. M. Hunink
Diagnostic Performance of Multidetector CT Angiography for Assessment of Coronary Artery Disease: Meta-analysis
Radiology, August 1, 2007; 244(2): 419 - 428.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (431)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leber, A. W.
Right arrow Articles by Boekstegers, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leber, A. W.
Right arrow Articles by Boekstegers, P.
Related Collections
Right arrowRelated Article

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement