J Am Coll Cardiol, 2004; 44:878-886, doi:10.1016/j.jacc.2004.05.050
© 2004 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jenkins, C.
Right arrow Articles by Marwick, T. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jenkins, C.
Right arrow Articles by Marwick, T. H.

ECHOCARDIOGRAPHY

Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography

Carly Jenkins, BS, Kristen Bricknell, BS, Lizelle Hanekom, MD and Thomas H. Marwick, MD, PhD, FACC*

University of Queensland, Brisbane, Australia

Manuscript received January 25, 2004; revised manuscript received April 19, 2004, accepted May 4, 2004.

* Reprint requests and correspondence: Dr. Thomas H. Marwick, University of Queensland Department of Medicine, Princess Alexandra Hospital, Ipswich Road, Brisbane, Q4102, Australia (Email: tmarwick{at}soms.uq.edu.au).


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES: We sought to determine whether assessment of left ventricular (LV) function with real-time (RT) three-dimensional echocardiography (3DE) could reduce the variation of sequential LV measurements and provide greater accuracy than two-dimensional echocardiography (2DE).

BACKGROUND: Real-time 3DE has become feasible as a standard clinical tool, but its accuracy for LV assessment has not been validated.

METHODS: Unselected patients (n = 50; 41 men; age, 64 ± 8 years) presenting for evaluation of LV function were studied with 2DE and RT-3DE. Test-retest variation was performed by a complete restudy by a separate sonographer within 1 h without alteration of hemodynamics or therapy. Magnetic resonance imaging (MRI) images were obtained during a breath-hold, and measurements were made off-line.

RESULTS: The test-retest variation showed similar measurements for volumes but wider scatter of LV mass measurements with M-mode and 2DE than 3DE. The average MRI end-diastolic volume was 172 ± 53 ml; LV volumes were underestimated by 2DE (mean difference, –54 ± 33; p < 0.01) but only slightly by RT-3DE (–4 ± 29; p = 0.31). Similarly, end-systolic volume by MRI (91 ± 53 ml) was underestimated by 2DE (mean difference, –28 ± 28; p < 0.01) and by RT-3DE (mean difference, –3 ± 18; p = 0.23). Ejection fraction by MRI was similar by 2DE (p = 0.76) and RT-3DE (p = 0.74). Left ventricular mass (183 ± 50 g) was overestimated by M-mode (mean difference, 68 ± 86 g; p < 0.01) and 2DE (16 ± 57; p = 0.04) but not RT-3DE (0 ± 38 g; p = 0.94). There was good inter- and intra-observer correlation between RT-3DE by two sonographers for volumes, ejection fraction, and mass.

CONCLUSIONS: Real-time 3DE is a feasible approach to reduce test-retest variation of LV volume, ejection fraction, and mass measurements in follow-up LV assessment in daily practice.

Abbreviations and Acronyms
  EF = ejection fraction
  LV = left ventricle/ventricular
  LVEDV = left ventricular end-diastolic volume
  LVESV = left ventricular end-systolic volume
  MM = M-mode
  MRI = magnetic resonance imaging
  RT = real-time
  2DE = two-dimensional echocardiography
  3DE = three-dimensional echocardiography


Left ventricular (LV) mass, volume, and ejection fraction (EF) are important prognostic factors (1) and are frequently requested for serial testing (2,3). However, although two-dimensional echocardiography (2DE) is widely available for LV assessment, it has limited test-retest reliability (3,4). Repeated EF measurements may differ because of poor image quality, geometric issues related to volume calculations, and the performance of off-axis cuts and variations in ventricular loading (5). Subjective visual assessment of LV EF, widely used because of these limitations of quantitation, is effective for single assessments but insufficiently reliable for sequential use. Consequently, cardiac magnetic resonance imaging (MRI) has been proposed as a more desirable alternative for LV assessment, especially in trials (2), although the cost and availability of MRI are problematic for routine clinical evaluation.

A number of advances may make the echocardiographic assessment of volumes, EF, and mass more consistent in the presence of constant load. Harmonic imaging has greatly improved image quality, and LV opacification with contrast has enabled improvements in endocardial border detection. Three-dimensional echocardiography (3DE) may overcome the geometric limitations of 2DE. Existing work with three-dimensional reconstruction, based on external localization of transducer angle in space, shows good correlation with MRI and autopsy volumes (6,7), superior to 2DE. Real-time (RT) 3DE may be more feasible for clinical use, as it is not based on an external transducer registration system, and a shorter scanning time may avoid problems arising from the use of multiple cycles such as breathing, variable R-R intervals, and patient movement.

Because both MRI and RT-3DE are three-dimensional techniques, we hypothesized that they may produce comparable results. Therefore, the objectives of this study were to: 1) compare LV volume, mass, and EF by RT-3DE and MRI; 2) determine if the test-retest variability of RT-3DE is clinically acceptable; and 3) compare RT-3DE to similar results from 2DE and M-mode (MM) to demonstrate the improvement achieved.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Patient selection.   We prospectively recruited 60 patients (48 men, age 63 ± 11 years) referred to the echocardiography laboratory for measurement of LV volume, mass, and EF. After exclusion of seven patients with technically inadequate echocardiographic images, one with inability to perform a breath-hold, and two patients who were unable to undergo MRI due to claustrophobia, a study group of 50 patients remained who underwent 2DE, RT-3DE, and MRI. The investigations were approved by the ethics committee of the Princess Alexandra Hospital, and all patients gave informed consent.

Study design.   Data for test-retest variability were obtained by discharging patients from the laboratory and repeating their imaging within 1 h with no intervening therapy. A subgroup (n = 20) was studied for inter-observer variability, which was determined by using the same set of three-dimensional and two-dimensional images measured by two separate sonographers. The same group was tested for intra-observer variability. Intra-observer repeated measures were performed on average one week apart, and the order of repeated analysis was randomized before analysis.

2DE.   An experienced sonographer acquired apical views of the LV, using harmonic imaging with a transthoracic 3-MHz phased array transducer (Sonos 7500, Philips Medical Systems, Andover, Massachusetts). Measurements of left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and EF were obtained using the software installed on the ultrasound machine, with LVEDV measurements at the time of mitral valve closure and LVESV measured on the image with the smallest LV cavity. The papillary muscles were excluded from the volumes. Biplane Simpson's rule volumes were obtained from the apical four- and two-chamber views (8); LV mass calculations were made by MM, 2DE, and 3DE, in accordance with the American Society of Echocardiography guidelines (9). Contrast was not given in this study.

RT-3DE.   Real-time 3DE images were obtained from an apical window with the patient in the same position. Images were also gathered over four cardiac cycles using a matrix array ultrasonographic transducer (x4 transducer, Philips Sonos 7500 system, Andover, Massachusetts).

Measurements of RT-3DE volumes and masses were performed off-line (4D analysis, Tomtec Gmbh, Untersclessheim, Germany). Frames for LVEDV and LVESV measurement were identified by the same method as 2DE, and endocardial contours were marked in 12 slices (i.e., 15 degrees per slice). Contour tracing was performed with semi-automatic border detection—after first identifying the apex and mitral annulus on each slice, a pre-configured ellipse was fitted to the endocardial borders of each frame and adjusted as required. The LVEDV and LVESV were measured from the resulting three-dimensional volume (Fig. 1A). For RT-3DE, an ellipse was also traced around the epicardial border in end-diastole to give a three-dimensional volume. The endocardial volume was then subtracted from the epicardial volume and multiplied by the specific gravity of heart muscle.



View larger version (93K):
[in this window]
[in a new window]
 
Figure 1 (A) Analysis of left ventricular (LV) volume using three-dimensional echocardiography. The figure demonstrates selection of one image (upper right), automated contour-tracing (upper left), superimposition of all contours in three-dimensional space (lower left), and the resulting time-volume curve (lower right). (B) Analysis of LV volume using magnetic resonance imaging. The position of apex and base is shown on the longitudinal plane images, and endocardial and epicardial borders are traced in the short-axis views. EDV = end-diastolic volume; EF = ejection fraction; ESV = end-systolic volume; LVM = left ventricular mass.

 
MRI.   Cardiac magnetic resonance images were obtained using a Sonata 1.5-T scanner (Siemens, Erlangen, Germany). Left ventricular anatomy and function images were acquired in horizontal and vertical long- and short-axis views using free induction, steady state precession imaging during a breath-hold. Acquisition time for cardiac magnetic resonance images was approximately 40 to 50 min. Off-line calculation of the LVEDV, LVESV, and EF were performed using Cardiac Image Modeling software (CIM version 4.2, Auckland University, Auckland, New Zealand). The LV volume calculation with this method is analogous to that used for 3DE and has previously been described (10). Using two long-axis and six or more short-axis views, markers were placed on the right ventricle and LV annulus, and the endocardial border was detected automatically (Fig. 1B). The same method was utilized to detect the epicardial border in the long- and short-axis views. Left ventricular mass was calculated by the same method as used with 3DE.

Statistical analysis.   Results for LVEDV, LVESV, EF, and mass are represented as mean and standard deviation. Correlations were performed between echocardiography and MRI measurements, and agreement was expressed according to the method of Bland and Altman (11,12). A value of p < 0.05 was considered to be significant. Z transformations were performed between each group to see if there was any significant difference between correlations (12). Data analyses were performed using SPSS statistical software (version 10, SPSS Inc., Chicago, Illinois).


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Patient characteristics.   Results of MRI, RT-3DE, and 2DE were analyzed in 50 patients (41 males, 64 ± 8 years). Table 1 summarizes the presence and etiology of LV dysfunction in each group; the majority had regional wall motion abnormalities.


View this table:
[in this window]
[in a new window]
 
Table 1. Clinical Characteristics of the Study Patients
 
Test-retest variation of 2DE and RT-3DE.   Test-retest variation was assessed in all 50 patients (Table 2). The correlation between sequential EF measurements was superior for RT-3DE compared with 2DE (Z = 5.5, p < 0.01), and variation was slightly less with RT-3DE (Fig. 2). Sequential volume measurements by each echocardiography technique also correlated well, but the correlation between measurements was superior for RT-3DE compared with 2DE for both LVEDV (Z = 4.9, p < 0.01) and LVESV (Z = 6.8, p < 0.01) (Table 2). Similarly, sequential LV mass measurements with RT-3DE showed less difference than with 2DE (Z = 0.53, p = 0.6) (Fig. 3), and both were superior to MM measurement of LV mass (Z = 1.97, p < 0.05).


View this table:
[in this window]
[in a new window]
 
Table 2. Correlation and Mean Difference Between the Sequential ("Test-Retest") Studies With 2DE and RT-3DE (n = 50)*
 


View larger version (22K):
[in this window]
[in a new window]
 
Figure 2 Test-retest comparisons of sequential ejection fraction (EF) for two-dimensional (2D) echocardiography (left panels) and real-time three-dimensional (3D) echocardiography (right panels) (n = 50).

 


View larger version (26K):
[in this window]
[in a new window]
 
Figure 3 Test-retest comparisons of sequential mass measurements for M-mode (left panels), two-dimensional echocardiography (center panels), and real-time three-dimensional (3D) echocardiography (right panels) (n = 50).

 
Inter- and intra-observer variation of RT-3DE and 2DE.   For all parameters, inter-observer agreement for RT-3DE exceeded that obtained with 2DE (Table 3). The widest discrepancy in inter-observer variabilitywas with MM measurement of LV mass (mean difference, 8 ± 39 g; R = 0.52; p < 0.01), with RT-3DE being superior to 2DE. There were significant differences between MM and 2DE and RT-3DE (Z = 3.0, p < 0.01 and Z = 10.43, p < 0.01).


View this table:
[in this window]
[in a new window]
 
Table 3. Inter-Observer Agreement With 2DE and RT-3DE (n = 20) Showing Correlations and Mean Difference Between the Studies
 
Similar findings were made with intra-observer variation (Table 4). Real-time 3DE showed significantly better intra-observer agreement than 2DE measurement of EF (Z = 10.5, p < 0.01), LVEDV (Z = 6.28, p < 0.01), and LVESV (Z = 7.65, p < 0.01). Again, the greatest intra-observer variation concerned LV mass (mean difference, 4 ± 26 g; R = 0.77; p < 0.01), and agreement was better with RT-3DE than 2DE (Z = 5.5, p < 0.01) as well as MM (Z = 7.05, p < 0.01). Two-dimensional echocardiography and MM were not significantly different (Z = 1.5, p = 0.13).


View this table:
[in this window]
[in a new window]
 
Table 4. Intra-Observer Agreement With 2DE and RT-3DE (n = 20) Showing R Values and Mean Difference Between the Studies
 
Validation with MRI.   The mean differences of the echocardiographic techniques from MRI techniques are summarized in Table 5. Of the echocardiographic methods for EF measurement, the use of RT-3DE gave the smallest measurement error and closest correlation to MRI (Fig. 4). The correlation of EF between MRI and the echocardiography techniques is summarized in Figure 5. Although LV mass was underestimated by RT-3DE and overestimated by both 2DE techniques, the greatest difference from MRI mass was MM-derived mass (mean difference, 68 ± 86 g; p < 0.01).


View this table:
[in this window]
[in a new window]
 
Table 5. Mean Difference Between Echocardiographic and MRI Measurements (n = 50)
 


View larger version (16K):
[in this window]
[in a new window]
 
Figure 4 Magnetic resonance imaging (MRI) comparisons with two-dimensional echocardiography (2DE) (left panel) and real-time three-dimensional (3D) echocardiography (right panel) for ejection fraction (EF) (n = 50).

 


View larger version (18K):
[in this window]
[in a new window]
 
Figure 5 Magnetic resonance imaging (MRI) comparisons with M-mode (left panel), two-dimensional (2D) echocardiography (center), and real-time three-dimensional (3D) echocardiography (right) for mass (n = 50).

 
Feasibility.   Table 6 summarizes the scanning times to acquire apical and parasternal views by 2DE and apical RT-3DE. Scanning time for RT-3DE was taken for multiple full volume datasets; acquisition time during each breath hold was approximately 10 s. The time required for calculation of LV volumes and mass from cardiac magnetic resonance images ranged from 10 to 15 min.


View this table:
[in this window]
[in a new window]
 
Table 6. Mean Acquisition and Calculation Times (n = 20)
 

    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
The results of this study indicate that three-dimensional imaging of the LV with either MRI or RT-3DE do indeed produce comparable results in patients with suitable echocardiography image quality. Real-time 3DE also provides low test-retest variation and high reproducibility of LV measurements between observers.

Test-retest variation.   In contrast with the more widely reported parameters of intra- and inter-observer variability, which relate to the repeated measurement of a single dataset, test-retest variation involves repetition of the entire acquisition and analysis. This parameter assumes particular importance in the use of a follow-up test. Both physiologic and imaging factors are contributors to variations in LV measurements in time. Standard parameters for LV assessment are strongly influenced by differences in loading conditions over time, and we sought to minimize these by repeating the study over a short time frame and without any treatment changes, so that the main source of variation related to imaging considerations.

Previous work found significant variations between sonographers with respect to both the angulation and displacement of 2DE imaging planes, with foreshortening of >90% of apical views (13). The limitations of standard echocardiographic measurements of LV mass have been highlighted in several studies (2,14), and they pose a critical issueif LV mass is used to help make decisions about initiating or altering treatment in hypertensive subjects. The degree of test-retest variation of volume measurements in this study was less than anticipated, probably because of the avoidance of variation of loading conditions due to the relatively short time between repeat testing. Nonetheless, while test-retest variability may be minimized by a skilled observer, the use of three-dimensional techniques may reduce the likelihood of variation being due to different cut-plane angulations.

Inter- and intra-observer variation.   Previous studies of volumetric and reconstructed 3DE (3–5) have shown that this technique shows higher reproducibility than 2DE. In particular, the use of a three-dimensional dataset is the most important aspect of minimizing variation, irrespective of the technique (echocardiography or MRI) (13).

In this study, inter-observer variation was optimized by the use of RT-3DE. While this likely reflects minimization of error derived by the selection of different 2DE cycles, it also reflects the use of a semi-automated edge-detection technique for LV volume and mass measurement. The importance of a standard approach to partition between the wall and cavity to minimizing variation is reinforced by the more favorable intra-observer results, implying that measurement (rather than acquisition) problems reflect different criteria for tracing the LV myocardium.

Validation of RT-3DE.   Although previous studies have validated the use of reconstructed and volumetric 3DE, we are unaware of an existing comparison of RT-3DE and 2DE with MRI. In this study of normal and abnormal ventricles, the majority of which showed regional wall motion abnormalities, volumes were underestimated by echocardiography—although less with RT-3DE than with any other technique. This systematic underestimation may, in part, reflect the correspendence between the "bright blood" MRI technique with ventriculography (both filling the space between trabeculations) and, in part, reflect the failure of the 2DE biplane method to depict the LV outflow tract (15).

Conclusions.   A clinically feasible echocardiographic approach to sequential assessment of LV volumes and mass would be of value in many settings, including the management of hypertension and heart failure and the follow-up of regurgitant valves. Despite its accuracy in clinical studies, MRI has yet to fill this role because of cost, availability, and more minor issues regarding device incompatibilities and patient tolerance. The development of RT-3DE has made the echocardiographic approach more feasible, although the analysis time remains longer than with MRI. The results of this study indicate that RT-3DE is a feasible approach to reduce test-retest variation and improve accuracy of LV volume, EF, and mass measurements in follow-up LV assessment in daily practice.


    Footnotes
 
Supported, in part, by a grant-in-aid from the National Health and Medical Research Council of Australia.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 

  1. Wang TJ, Evans JC, Benjamin EJ, Levy D, LeRoy EC, Vasan RS. Natural history of asymptomatic left ventricular systolic dysfunction in the community Circulation 2003;108:977-982.[Abstract/Free Full Text]
  2. Bottini PB, Carr AA, Prisant LM, Flickinger FW, Allison JD, Gottdiener JS. Magnetic resonance imaging compared to echocardiography to assess left ventricular mass in the hypertensive patient Am J Hypertens 1995;8:221-228.[CrossRef][Medline]
  3. Gopal AS, Shen Z, Sapin PM, et al. Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods Circulation 1995;92:842-853.[Abstract/Free Full Text]
  4. Mondelli JA, Di Luzio S, Nagaraj A, et al. The validation of volumetric real-time 3-dimensional echocardiography for the determination of left ventricular function J Am Soc Echocardiogr 2001;14:994-991000.[CrossRef][Medline]
  5. Hibberd MG, Chuang ML, Beaudin RA, et al. Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction Am Heart J 2000;140:469-475.[CrossRef][Medline]
  6. King DL, Coffin L, Maurer MS. Noncompressibility of myocardium during systole with freehand three-dimensional echocardiography J Am Soc Echocardiogr 2002;15:1503-1506.[Medline]
  7. Gopal AS, Schnellbaecher MJ, Shen Z, Akinboboye OO, Sapin PM, King DL. Freehand three-dimensional echocardiography for measurement of left ventricular massin vivo anatomic validation using explanted human hearts. J Am Coll Cardiol 1997;30:802-810.[Abstract]
  8. Stamm RB, Carabello BA, Mayers DL, et al. Two-dimensional echocardiographic measurement of left ventricular ejection fractionprospective analysis of what constitutes an adequate determination. Am Heart J 1982;104:136-144.[CrossRef][Medline]
  9. Park SH, Shub C, Nobrega TP, Bailey KR, Seward JB. Two-dimensional echocardiographic calculation of left ventricular mass as recommended by the American Society of Echocardiographycorrelation with autopsy and M-mode echocardiography. J Am Soc Echocardiogr 1996;9:119-128.[CrossRef][Medline]
  10. Swingen CM, Seethamraju RT, Jerosch-Herold M. Feedback-assisted three-dimensional reconstruction of the left ventricle with MRI J Magn Reson Imaging 2003;17:528-537.[Medline]
  11. Bland JM, Altman DG. Correlation, regression, and repeated data BMJ 1994;308:896.[Free Full Text]
  12. Bland JM, Altman DG. Calculating correlation coefficients with repeated observationspart 2—correlation between subjects. BMJ 1995;310:633.[Free Full Text]
  13. King DL, Harrison MR, King Jr. DL, Gopal AS, Kwan OL, DeMaria AN. Ultrasound beam orientation during standard two-dimensional imaging: assessment by three-dimensional echocardiography J Am Soc Echocardiogr 1992;5:569-576.[Medline]
  14. Gottdiener JS, Livengood SV, Meyer PS, Chase GA. Should echocardiography be performed to assess effects of antihypertensive therapy? Test-retest reliability of echocardiography for measurement of left ventricular mass and function J Am Coll Cardiol 1995;25:424-430.[Abstract]
  15. Chuang ML, Hibberd MG, Salton CJ, et al. Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fractionassessment by two- and three-dimensional echocardiography and magnetic resonance imaging. J Am Coll Cardiol 2000;35:477-484.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Eur Heart JHome page
C. Jenkins, S. Moir, J. Chan, D. Rakhit, B. Haluska, and T. H. Marwick
Left ventricular volume measurement with echocardiography: a comparison of left ventricular opacification, three-dimensional echocardiography, or both with magnetic resonance imaging
Eur. Heart J., November 8, 2008; (2008) ehn484v1.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
A. Bhan, S. Kapetanakis, B.S. Rana, E. Ho, K. Wilson, P. Pearson, S. Mushemi, J. Deguzman, J. Reiken, M.D. Harden, et al.
Real-time three-dimensional myocardial contrast echocardiography: is it clinically feasible?
Eur J Echocardiogr, November 1, 2008; 9(6): 761 - 765.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
T. H. Marwick and M. Schwaiger
The Future of Cardiovascular Imaging in the Diagnosis and Management of Heart Failure, Part 2: Clinical Applications
Circ Cardiovasc Imaging, September 1, 2008; 1(2): 162 - 170.
[Full Text] [PDF]


Home page
HeartHome page
A-C Pouleur, J-B le Polain de Waroux, A Pasquet, B L Gerber, O Gerard, P Allain, and J-L J Vanoverschelde
Assessment of left ventricular mass and volumes by three-dimensional echocardiography in patients with or without wall motion abnormalities: comparison against cine magnetic resonance imaging
Heart, August 1, 2008; 94(8): 1050 - 1057.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
T. H. Marwick and M. Schwaiger
The Future of Cardiovascular Imaging in the Diagnosis and Management of Heart Failure, Part 1: Tasks and Tools
Circ Cardiovasc Imaging, July 1, 2008; 1(1): 58 - 69.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
V. Mor-Avi, C. Jenkins, H. P. Kuhl, H.-J. Nesser, T. Marwick, A. Franke, C. Ebner, B. H. Freed, R. Steringer-Mascherbauer, H. Pollard, et al.
Real-Time 3-Dimensional Echocardiographic Quantification of Left Ventricular Volumes: Multicenter Study for Validation With Magnetic Resonance Imaging and Investigation of Sources of Error
J. Am. Coll. Cardiol. Img., July 1, 2008; 1(4): 413 - 423.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
T. Nishikage, H. Nakai, V. Mor-Avi, R. M. Lang, I. S. Salgo, S. H. Settlemier, S. Husson, and M. Takeuchi
Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography
Eur J Echocardiogr, May 13, 2008; (2008) jen166v1.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. L. Gutierrez-Chico, J. L. Zamorano, E. Prieto-Moriche, R. A. Hernandez-Antolin, M. Bravo-Amaro, L. Perez de Isla, M. Sanmartin-Fernandez, J. A. Baz-Alonso, and A. Iniguez-Romo
Real-time three-dimensional echocardiography in aortic stenosis: a novel, simple, and reliable method to improve accuracy in area calculation
Eur. Heart J., May 2, 2008; 29(10): 1296 - 1306.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
S. P. Hoole, J. Boyd, V. Ninios, J. Parameshwar, and R. A. Rusk
Measurement of cardiac output by real-time 3D echocardiography in patients undergoing assessment for cardiac transplantation
Eur J Echocardiogr, May 1, 2008; 9(3): 334 - 337.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
C. Jenkins, M. Monaghan, G. Shirali, R. Guraraja, and T. H. Marwick
An intensive interactive course for 3D echocardiography: is 'crop till you drop' an effective learning strategy?
Eur J Echocardiogr, May 1, 2008; 9(3): 373 - 380.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
B. D. Soriano, M. Hoch, A. Ithuralde, T. Geva, A. J. Powell, B. D. Kussman, D. A. Graham, W. Tworetzky, and G. R. Marx
Matrix-Array 3-Dimensional Echocardiographic Assessment of Volumes, Mass, and Ejection Fraction in Young Pediatric Patients With a Functional Single Ventricle: A Comparison Study With Cardiac Magnetic Resonance
Circulation, April 8, 2008; 117(14): 1842 - 1848.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J L Hare, C Jenkins, S Nakatani, A Ogawa, C-M Yu, and T H Marwick
Feasibility and clinical decision-making with 3D echocardiography in routine practice
Heart, April 1, 2008; 94(4): 440 - 445.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
S.-C. Yap, R.-J. M. van Geuns, A. Nemes, F. J. Meijboom, J. S. McGhie, M. L. Geleijnse, M. L. Simoons, and J. W. Roos-Hesselink
Rapid and accurate measurement of LV mass by biplane real-time 3D echocardiography in patients with concentric LV hypertrophy: comparison to CMR
Eur J Echocardiogr, March 1, 2008; 9(2): 255 - 260.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M. I Burgess, C. Jenkins, J. Chan, and T. H Marwick
Measurement of left ventricular dyssynchrony in patients with ischaemic cardiomyopathy: a comparison of real-time three-dimensional and tissue Doppler echocardiography
Heart, October 1, 2007; 93(10): 1191 - 1196.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. N. Kirkpatrick, M. A. Vannan, J. Narula, and R. M. Lang
Echocardiography in Heart Failure: Applications, Utility, and New Horizons
J. Am. Coll. Cardiol., July 31, 2007; 50(5): 381 - 396.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
C. Jenkins, J. Chan, K. Bricknell, M. Strudwick, and T. H. Marwick
Reproducibility of Right Ventricular Volumes and Ejection Fraction Using Real-time Three-Dimensional Echocardiography: Comparison With Cardiac MRI
Chest, June 1, 2007; 131(6): 1844 - 1851.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
H. Jaochim Nesser, L. Sugeng, C. Corsi, L. Weinert, J. Niel, C. Ebner, R. Steringer-Mascherbauer, F. Schmidt, G. Schummers, R. M Lang, et al.
Volumetric analysis of regional left ventricular function with real-time three-dimensional echocardiography: validation by magnetic resonance and clinical utility testing
Heart, May 1, 2007; 93(5): 572 - 578.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. De Castro, S. Caselli, M. Maron, A. Pelliccia, E. Cavarretta, P. Maddukuri, D. Cartoni, E. Di Angelantonio, J. T Kuvin, A. R Patel, et al.
Left ventricular remodelling index (LVRI) in various pathophysiological conditions: a real-time three-dimensional echocardiographic study
Heart, February 1, 2007; 93(2): 205 - 209.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Cannesson, M. Tanabe, M. S. Suffoletto, D. M. McNamara, S. Madan, J. M. Lacomis, and J. Gorcsan III
A Novel Two-Dimensional Echocardiographic Image Analysis System Using Artificial Intelligence-Learned Pattern Recognition for Rapid Automated Ejection Fraction
J. Am. Coll. Cardiol., January 16, 2007; 49(2): 217 - 226.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. D. Thomas and Z. B. Popovic
Assessment of Left Ventricular Function by Cardiac Ultrasound
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2012 - 2025.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. M. Lang, V. Mor-Avi, L. Sugeng, P. S. Nieman, and D. J. Sahn
Three-Dimensional Echocardiography: The Benefits of the Additional Dimension
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2053 - 2069.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. C. Houck, J. E. Cooke, and E. A. Gill
Live 3D Echocardiography: A Replacement for Traditional 2D Echocardiography?
Am. J. Roentgenol., October 1, 2006; 187(4): 1092 - 1106.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Sugeng, V. Mor-Avi, L. Weinert, J. Niel, C. Ebner, R. Steringer-Mascherbauer, F. Schmidt, C. Galuschky, G. Schummers, R. M. Lang, et al.
Quantitative Assessment of Left Ventricular Size and Function: Side-by-Side Comparison of Real-Time Three-Dimensional Echocardiography and Computed Tomography With Magnetic Resonance Reference
Circulation, August 15, 2006; 114(7): 654 - 661.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
E. G. Caiani, L. Sugeng, L. Weinert, A. Capderou, R. M. Lang, and P. Vaida
Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography
J Appl Physiol, August 1, 2006; 101(2): 460 - 468.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Fukuda, G. Saracino, Y. Matsumura, M. Daimon, H. Tran, N. L. Greenberg, T. Hozumi, J. Yoshikawa, J. D. Thomas, and T. Shiota
Three-Dimensional Geometry of the Tricuspid Annulus in Healthy Subjects and in Patients With Functional Tricuspid Regurgitation: A Real-Time, 3-Dimensional Echocardiographic Study
Circulation, July 4, 2006; 114(1_suppl): I-492 - I-498.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
E. H. Y. Ie and R. Zietse
Evaluation of cardiac function in the dialysis patient--a primer for the non-expert
Nephrol. Dial. Transplant., June 1, 2006; 21(6): 1474 - 1481.
[Full Text] [PDF]


Home page
HeartHome page
E G Caiani, C Corsi, L Sugeng, P MacEneaney, L Weinert, V Mor-Avi, and R M Lang
Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiography
Heart, February 1, 2006; 92(2): 213 - 219.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M. J Monaghan
Role of real time 3D echocardiography in evaluating the left ventricle
Heart, January 1, 2006; 92(1): 131 - 136.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. De Simone, I. Wolf, S. Mottl-Link, B. W. Bottiger, H. Rauch, H.-P. Meinzer, and S. Hagl
Intraoperative assessment of right ventricular volume and function
Eur. J. Cardi