JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 2003; 41:1926-1932, doi:10.1016/S0735-1097(03)00426-1
© 2003 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, M. A.

CLINICAL RESEARCH: CLINICAL TRIAL

The effect of atrial pacing therapies on atrial tachyarrhythmia burden and frequency

Results of a randomized trial in patients with bradycardia and atrial tachyarrhythmias

Michael A. Lee, MD, FACC*,*, Richard Weachter, MD, FACC{dagger}, Scott Pollak, MD, FACC{ddagger}, Mark S. Kremers, MD, FACC§, Ajay M. Naik, MD||, Russell Silverman, MD, FACC, Joann Tuzi, RN**, Wayne Wang, MS**, Linda J. Johnson, PhD**, David E. Euler, PhD** ATTEST Investigators

* John Muir/Mount Diablo Medical Center, Walnut Creek, California, USA
{dagger} Ferrell-Duncan Clinic and Cox Medical Center, Springfield, Missouri, USA
{ddagger} Florida Heart Institute and Florida Hospital, Orlando, Florida, USA
§ MidCarolina Cardiology and Presbyterian Hospital, Charlotte, North Carolina, USA
|| Cedar-Sinai Medical Center and UCLA School of Medicine, Los Angeles, California, USA
St. Joseph’s Hospital Health Center, Syracuse, New York, USA
** Medtronic Inc., Minneapolis, Minnesota, USA

Manuscript received September 27, 2002; revised manuscript received February 20, 2003, accepted February 25, 2003.

* Reprint requests and correspondence: Dr. Michael A. Lee, 365 Hawthorne Avenue, #201, Oakland, California 94609, USA.
drmichaelalee{at}yahoo.com


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
OBJECTIVES: The Atrial Therapy Efficacy and Safety Trial (ATTEST) was a prospective, randomized study to evaluate preventive pacing and antitachycardia pacing (ATP) in patients with symptomatic atrial fibrillation (AF) or atrial tachycardia (AT).

BACKGROUND: The effect of the combination of atrial prevention and termination algorithms on AT/AF burden and frequency in pacemaker patients is unknown.

METHODS: A DDDRP pacemaker (AT500, Medtronic Inc., Minneapolis, Minnesota) with three atrial preventive pacing algorithms and two ATP algorithms was implanted in 368 patients. Patients were randomized one-month post-implant to all prevention and ATP therapies ON or OFF and followed for three months. The OFF group had DDDR pacing at a lower programmed rate of 60 ppm. The AT/AF burden and frequency were determined from daily device counters in 324 patients treated according to protocol.

RESULTS: In 17,018 episodes with stored electrograms, appropriate detection was confirmed in 17,004 (99.9%). The median percentage of atrial pacing was 98% in the ON group versus 75% in the OFF group (p < 0.001). Using device-defined criteria for successful termination, ATP terminated 8,590 (54%) of 15,789 treated episodes. The median AT/AF burden during the three-month study period was 4.2 h/month ON versus 1.1 h/month OFF (p = 0.20). The median AT/AF frequency was 1.3 episodes/month ON versus 1.2 episodes/month OFF (p = 0.65). System-related, complication-free survival at four months was 90.2% (Kaplan-Meier estimate).

CONCLUSIONS: This DDDRP pacemaker is safe, has accurate AT/AF detection, and provides ATP with 54% efficacy as defined by the device. The atrial prevention and termination therapies combined did not reduce AT/AF burden or frequency in this patient population.

Abbreviations and Acronyms
  A:V
  atrial:ventricular
  AF
  atrial fibrillation
  AT
  atrial tachycardia
  ATP
  antitachycardia pacing
  GEE
  generalized estimating equation


There is considerable interest in the use of atrial pacing to prevent and treat atrial tachyarrhythmias. There is evidence that atrial pacing in pacemaker patients reduces the incidence of atrial tachyarrhythmias compared to VVI pacing (1–3). To increase the ability of atrial pacing to suppress the onset of atrial tachyarrhythmias, sophisticated algorithms have been developed that increase the percentage of atrial pacing (4–6). In addition to pacing algorithms for prevention, device-based antitachycardia pacing (ATP) has been shown to effectively terminate atrial tachyarrhythmias (6,7). The purpose of this prospective randomized study was to evaluate the efficacy and safety of prevention and termination therapies in a DDDRP pacemaker. Using the diagnostic features of the device to measure daily atrial tachyarrhythmia burden and frequency, the hypothesis was that activation of the prevention and termination therapies would reduce the burden and frequency of atrial tachyarrhythmias.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
Device characteristics.   The device (AT500, Medtronic Inc., Minneapolis, Minnesota) features include DDDR pacing and DDIR mode switch during atrial tachyarrhythmias. Atrial tachyarrhythmias are detected when the median atrial cycle length (12 beats) is less than the programmed atrial tachycardia (AT) or atrial fibrillation (AF) detection interval, and the atrial:ventricular (A:V) ratio is >1:1 for at least 24 ventricular beats. The detection algorithm rejects atrial events resulting from far-field R waves and classifies the rhythm as AF or AT based on cycle length and cycle length regularity (6,7). The device stores an atrial electrogram as well as event markers for up to 35 episodes between interrogations. In addition, the number of daily AT/AF events and total duration of AT/AF episodes per day are stored by the device for up to 14 months (Fig. 1).



View larger version (29K):
[in this window]
[in a new window]
 
Figure 1 Cardiac compass report. The atrial pacing therapies were activated on January 20. The vertical dashed line indicates the last device interrogation. The atrial tachycardia (AT)/atrial fibrillation (AF) Patient Check indicates the days that the patient used his or her activator because of symptoms. The patient received the activator at the time of randomization. CV = cardioversion.

 
For episode termination, two rate-adaptive atrial ATP therapies are available (Burst+ and Ramp) to treat AT episodes (6,7). The device classifies a therapy as successful only if five consecutive sinus beats or paced beats with a normal A:V pattern are detected before AT/AF redetection within a 3-min window. If AT/AF is redetected before five consecutive sinus beats, the therapy is considered unsuccessful. The redetection of AT/AF after a therapy requires at least 32 ventricular beats, and this usually occurs within 20 to 30 s. If AT/AF is redetected after five consecutive sinus beats, the therapy is considered successful and the device logs a new episode. If AT/AF is not redetected and five consecutive sinus beats are not detected within 3 min, the detection algorithm considers the episode to have terminated and the therapy is classified as unsuccessful.

The device also has three pacing algorithms designed to prevent AT/AF recurrence. These include an atrial overdrive algorithm designed to maintain the programmed atrial escape interval just ahead of the intrinsic rate (atrial preference pacing), a temporary atrial overdrive mode designed to prevent short-long intervals after a premature atrial contraction (atrial rate stabilization), and a post-mode-switch overdrive pacing mode designed to inhibit the early recurrence of AT/AF after episode termination (6,7).

Study design and patient population.   Eligible patients were those having American College of Cardiology/American Heart Association class I or II indications for a standard dual-chamber pacemaker (8) and a history of AT/AF. Patients were required to have at least one episode of paroxysmal or persistent AT/AF documented by electrocardiogram within the past year and one symptomatic episode in the past three months. Patients with permanent AF, an indication for an implantable defibrillator, or New York Heart Association functional class IV heart failure were excluded. All patients gave written informed consent according to a protocol approved by the local human subjects committee at the implanting center.

Bipolar right atrial and ventricular leads were required at implant, with ≤10 mm interelectrode spacing recommended. Atrial detection was programmed ON at implant in all patients, and DDDR pacing was programmed at a lower rate of 60 ppm and an upper rate of 120 ppm. A one-month run-in period was allowed for lead fixation and drug stabilization. At the one-month visit, patients were randomized to all prevention and termination therapies ON or OFF (Table 1) and followed for three months.


View this table:
[in this window]
[in a new window]
 
Table 1 Required Programming at Randomization

 
Data analysis.   The effect of atrial therapies on AT/AF burden and total AT/AF frequency was the primary efficacy end point. Burden was calculated by summing the daily time spent in AT/AF and dividing by the follow-up duration (Fig. 1). Total frequency was calculated by summing the daily number of AT/AF episodes logged by the device and dividing by the duration of follow-up. To be included in the final analysis, patients needed ≥28 days of follow-up with strict programming compliance (Table 1). In addition, patients were excluded if they developed chronic AF before randomization that persisted throughout the study period.

Secondary efficacy end points included the accuracy of the detection algorithm, ATP efficacy, and symptomatic AT/AF frequency. The accuracy of the detection algorithm was determined by investigator review of stored AT/AF episodes. The ATP efficacy was expressed as the incidence of successful terminations based on the device counters. Symptomatic frequency was determined similar to total frequency except that only episodes were counted that were associated with one or more manual symptom markers (Fig. 1).

The primary safety end point was system-related, complication-free survival in all patients enrolled. System-related complications were defined as clinical events with potential adverse effects requiring invasive interventions specifically related to the device, the implanted leads, or the implant procedure. Adverse clinical events were analyzed and classified by an independent physician advisory committee.

Statistical analyses.   Statistical analyses were performed using SAS statistical software (SAS Institute, Cary, North Carolina). Continuous data were reported as the mean ± SD or as the median along with the 25th to 75th percentile. A Kaplan-Meier estimate was obtained for complication-free survival. Comparisons between groups were performed using a Wilcoxon rank-sum test for unpaired data, a Wilcoxon signed rank test for paired data, or a chi-square test. For the evaluation of ATP efficacy and the efficacy of the detection algorithm, the generalized estimating equation (GEE) method was used with an exchangeable correlation structure (9). This technique adjusts for multiple episodes in a single patient and yields an average estimate that is based on the number of patients as well as the number of episodes per patient. For all statistical comparisons, the null hypothesis was rejected when p ≤ 0.05.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
There were 370 patients enrolled at 28 centers worldwide and 368 devices implanted. The atrial leads were implanted in the atrial appendage (70%), the lateral free wall (12%), the high right atrium (11%), or the interatrial septum (0.5%). There were 324 patients included in the efficacy cohort. Reasons for exclusion included: <28 days of follow-up with all atrial therapies programmed according to protocol (n = 19), chronic AF before randomization (n = 12), death before randomization (n = 6), inadequate pacing and/or sensing (n = 3), explant before randomization (n = 2), and patient consent withdrawn before randomization (n = 1). The average follow-up time during the study period was 82 ± 13 days in the ON group and 85 ± 16 days in the OFF group (p = 0.96).

The demographics of the patients in the efficacy cohort are shown in Table 2. There were no significant differences in baseline characteristics between the ON and OFF groups. The antiarrhythmic drugs used are shown in Table 3. There were no significant differences in the use of drugs between the ON and OFF groups at either follow-up time, and there were no significant changes in drug use over time in the two groups.


View this table:
[in this window]
[in a new window]
 
Table 2 Patient Characteristics at Enrollment

 

View this table:
[in this window]
[in a new window]
 
Table 3 Medications Used in the Efficacy Cohort

 
Detection of atrial episodes.   There were 271 patients who had 17,018 AT/AF episodes with a stored electrogram (8 s) available for review during the four-month follow-up period. The positive predictive accuracy of the detection algorithm was 99.9% (GEE-adjusted estimate, 99.7%), based on 17,004 episodes classified as appropriate by the investigators.

Atrial and ventricular pacing.   The number of atrial and ventricular paced and sensed beats were determined from the daily trend counters (atrial beats were not counted during an AT/AF episode) and summed over the study period in each patient. The median amount of atrial pacing was 98% (25th to 75th percentile, 97% to 99%) in the ON group and 75% (25th to 75th percentile, 38% to 95%) in the OFF group (p < 0.001). The median amount of ventricular pacing was 99% (25th to 75th percentile, 95% to 100%) in the ON group and 98% (25th to 75th percentile, 81% to 100%) in the OFF group (p = 0.005).

Atrial ATP.   A total of 94 patients in the ON group experienced 54,976 AT/AF episodes during the three-month study period, and 15,789 of these episodes were treated with ATP in 85 patients. There were 8,590 treated episodes that were classified by the device as successfully terminated, yielding an efficacy of 54.4% (GEE adjusted estimate, 41.4%). An example of an episode treated successfully by ATP is shown in Figure 2.



View larger version (17K):
[in this window]
[in a new window]
 
Figure 2 An atrial tachycardia (AT) episode that was terminated by Ramp therapy. The graph shows the intervals between atrial (A-A) and ventricular (V-V) events at episode onset, detection, first therapy, and termination. The Ramp therapy was initiated 3.8 min after detection and resulted in the immediate termination of the atrial tachyarrhythmia. AF = atrial fibrillation.

 
Burden and frequency.   The median burden and frequency during the run-in and study periods for the efficacy cohort are shown in Table 4. There were no significant differences in burden, total frequency, or symptomatic frequency between the ON and OFF groups during the study period. The AT/AF episodes were detected during the study period in 61% of patients in the ON group and 60% in the OFF group (p = 0.84). Symptomatic episodes were logged in 33% of patients in the ON group and 31% in the OFF group (p = 0.84). The burden and frequency during the run-in period were also analyzed to ensure that the two treatment groups were similar before randomization. The burden and frequency during the run-in period were not significantly different between the two groups. A paired analysis was also performed to compare the burden and frequency observed during the study period with the burden and frequency observed during the run-in period. The analysis was performed in both the ON and OFF groups, and no significant differences were observed (p ≥ 0.70).


View this table:
[in this window]
[in a new window]
 
Table 4 AT/AF Burden and Frequency in the Efficacy Cohort

 
Although burden and frequency were not altered by the therapies in the overall study population, it is possible that the inclusion of patients who had no episodes during the run-in period may have influenced the study outcome. Therefore, a retrospective analysis of burden and frequency was performed after stratifying the patients on the basis of the presence of episodes during the run-in period. The atrial therapies did not significantly alter burden or frequency in patients with or without AT/AF episodes during the run-in period (p ≥ 0.40).

It is also conceivable that there may have been a subgroup of patients receiving a particular type of antiarrhythmic drug or with a certain demographic profile that may have derived benefit from the therapies. Therefore, multiple subgroup analyses were performed after stratifying patients on the basis of their baseline characteristics (Table 2) or the use of antiarrhythmic drugs at one month (Table 3). The results of these analyses did not identify a responder subgroup.

Episode duration.   Figure 3 shows a histogram of AT/AF episodes based on duration. The device counters automatically grouped episodes into eight duration bands. Only seven bands are displayed because episodes lasting <1 min were not eligible to receive ATP. There were 28,735 episodes <1 min in the ON group and 20,395 episodes in the OFF group. There were 26,241 episodes ≥1 min in the ON group and 28,229 episodes in the OFF group. The majority of all episodes (≥80%) terminated within 10 min in both groups. Only 60% of the episodes ≥1 min in the ON group were treated with ATP therapy. For each patient in the ON and OFF groups, the number of episodes in each duration band was divided by the follow-up time. This yielded eight band-specific AT/AF frequencies. The median frequency in each band was compared between the ON and OFF groups (Wilcoxon rank-sum test), and no significant differences were observed (p ≥ 0.17).



View larger version (32K):
[in this window]
[in a new window]
 
Figure 3 Histogram of atrial tachycardia/atrial fibrillation episode duration. The median episode frequency in each duration band was compared between the ON and OFF groups, and no significant differences were observed (p ≥ 0.17).

 
Safety.   There were 39 system-related complications reported in 36 patients during the four-month follow-up period. The most common were atrial lead dislodgement (n = 11), ventricular lead dislodgement (n = 5), and pericardial effusion (n = 4). The Kaplan-Meier estimate of system-related, complication-free survival at four months post-implant was 90.2% with a 95% confidence interval of 86.7% to 92.8%.

There were nine deaths over the course of the four-month follow-up period; six occurred before randomization and one was classified as procedure related. Causes of death included cardiac arrest (n = 3), cardiogenic shock (n = 2), congestive heart failure (n = 1), ventricular arrhythmia (n = 1), and renal failure (n = 1). One death was classified as unknown owing to inability of the site to acquire patient records from an outlying facility.

There were 65 external cardioversions to treat AT/AF in 59/368 patients during the four-month follow-up period. The largest number of cardioversions occurred at the time of implant (48%). In the efficacy cohort, there were 7 (4.6%) cardioversions in the ON group and 2 (1.2%) in the OFF group during the study period (p = 0.13).


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
This study demonstrated the safety and efficacy of a DDDRP pacemaker with atrial tachyarrhythmia prevention and termination therapies in a patient population with bradycardia and symptomatic AT/AF. The device was implanted in 99.5% of patients enrolled, and the four-month system-related, complication-free survival was 90.2%. The most frequent system-related complications were lead dislodgements. The positive predictive accuracy for atrial arrhythmia detection was 99.9%. The results on safety and detection accuracy in the present study confirm previous findings in a similar patient population (6).

The atrial prevention and termination therapies combined did not significantly alter burden, total frequency, or symptomatic frequency. The median burden was higher in the ON group during the study period, but this was also observed during the run-in period. The atrial therapies failed to reduce burden and frequency despite an increase in the relative amount of atrial pacing from a median of 75% to 98% and an ATP efficacy of 54%. It is possible that the high proportion of ventricular pacing (median = 99%) may have exerted a deleterious effect and limited any benefit from the atrial therapies. The ATP efficacy of 54% confirms the results of previous findings with this device in patients with bradycardia and AT/AF (6). Although a neutral effect of the atrial therapies on burden and frequency was reported in the previous study, patients were not randomized and the analysis was retrospective (6). In the present study, the effect of the atrial therapies on burden and frequency was evaluated prospectively with strict regulation of device programming. Because the outcome of the prospective analysis was neutral, several retrospective analyses were performed that stratified patients on the basis of demographics, antiarrhythmic drug use, or the presence of episodes during the run-in period. These retrospective analyses failed to identify a responder subgroup.

The failure of the atrial therapies to reduce burden stands in contrast to a previous study that evaluated burden in patients with a history of both atrial and ventricular tachyarrhythmias implanted with a device that had atrial defibrillation capabilities as well as pacing therapies (10). In that study, the median AT/AF burden was significantly reduced from 2.7 to 0.1 h/month in a highly selected subgroup of patients (41/269) who had atrial pacing (prevention and termination) therapies programmed ON, but did not receive atrial shocks. Although the explanation for the difference in the outcome of the two studies is not clear, several factors may have been operative. There were differences in the study designs, patient populations, antiarrhythmic drug use during follow-up, and the pacing algorithms employed for prevention and termination. In addition, episodes with cycle lengths <220 ms were not treated with ATP in the present study but were treated with ATP and/or 50-Hz burst pacing in the previous study (10).

Given the inclusion criteria of at least one symptomatic episode in the three months before implant in the present study, it was interesting that about 40% of the patients in both groups had no episodes during the study period. Because bradycardia may play a role in the initiation of AT/AF, DDDR pacing may have suppressed AT/AF in some patients. Moreover, changes in type or dosage of antiarrhythmic drugs before randomization may have played a role in AT/AF suppression during follow-up.

In addition to providing information on burden and frequency, the device also generated a histogram that grouped episodes into eight different duration bands. Because the precise duration of each episode was not stored, it was not possible to directly link the histogram to burden in a given patient. The histogram showed that the majority of episodes (≥80%) in both groups terminated within 10 min. The atrial therapies did not have a significant effect on the frequency of episodes in any of the eight duration bands. The lack of a significant effect of the atrial therapies on the duration histogram is consistent with the lack of an effect of the therapies on burden.

Study limitations.   There are several important limitations of this study. The device stores 35 episodes between interrogations and, thus, only about 10% of all episodes logged by the daily counters were available for review. The daily counters did not store the episode type (AT or AF); thus, it was not possible to distinguish AT burden from AF burden. The daily counters also did not store the time of each episode; therefore, the time interval between episodes could not be evaluated. There was no mechanism in place to ensure that patients used their patient activators to log all symptomatic episodes during the study period; therefore, the number of true symptomatic episodes may have been underestimated. Furthermore, a three-month follow-up period after randomization may have been insufficient to adequately characterize burden and frequency.


    Conclusions
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 
The results of this prospective, randomized clinical trial show that this DDDRP pacemaker is safe in patients with bradycardia and symptomatic AT/AF. The dual-chamber algorithm was effective in detecting 99.9% of AT/AF episodes, and the ATP efficacy as defined by the device was 54%. Activation of the prevention algorithms increased the relative amount of atrial pacing from 75% to 98%. The atrial prevention and termination therapies combined did not reduce burden, total frequency, or symptomatic frequency. The failure of the atrial therapies to reduce burden or frequency may have been partially due to the suppression of bradycardia-induced AT/AF by DDDR pacing.


    Footnotes
 
This study was supported by a grant from Medtronic Inc., Minneapolis, Minnesota. J. Tuzi, W. Wang, L. J. Johnson, and D. E. Euler are employees of Medtronic Inc.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 Conclusions
 References
 

  1. Andersen HR, Nielsen JC, Thomsen PEB, et al. Long-term follow-up of patients from a randomized trial of atrial versus ventricular pacing for sick-sinus syndrome. Lancet. 1997;350:1210–1216[CrossRef][Medline]
  2. Connolly SJ, Kerr CR, Gent M, et al. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med. 2000;342:1385–1391[Abstract/Free Full Text]
  3. Lamas GA, Lee KL, Sweeney MO, et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med. 2002;346:1854–1862[Abstract/Free Full Text]
  4. Garrigue S, Barold SS, Cazeau S, et al. Prevention of atrial arrhythmias during DDD pacing by atrial overdrive. Pacing Clin Electrophysiol. 1998;21:1751–1759[CrossRef][Medline]
  5. Carrlson MD, Gold MR, Ip J, Messenger J, Beau S, Cameron D. Dynamic atrial overdrive pacing decreases symptomatic atrial arrhythmia burden in patients with sinus node dysfunction. (abstr)Circulation. 2001;104:II383
  6. Israel CW, Hügl B, Lawo T, et al. Pace-termination and pacing for prevention of atrial tachyarrhythmias: results from a multicenter study with an implantable device for atrial therapy. J Cardiovasc Electrophysiol. 2001;12:1121–1128[CrossRef][Medline]
  7. Israel CW, Ehrlich JR, Gromefeld G, et al. Prevalence, characteristics and clinical implications of regular atrial tachyarrhythmias in patients with atrial fibrillation: insights from a study using a new implantable device. J Am Coll Cardiol. 2001;38:355–363[Abstract/Free Full Text]
  8. Gregoratos G, Cheitlin MD, Conill A, et al. Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: executive summary—a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). Circulation. 1998;97:1325–1335[Free Full Text]
  9. Zeger SL, Liang KY, Albert PS. Models for longitudinal data: a generalized estimating equation approach. Biometrics. 1988;44:1049–1060[CrossRef][Medline]
  10. Friedman PA, Dijkman B, Warman EN, et al. Atrial therapies reduce atrial arrhythmia burden in defibrillator patients. Circulation. 2001;104:1023–1028[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
J. Am. Coll. Cardiol., May 27, 2008; 51(21): e1 - e62.
[Full Text] [PDF]


Home page
CirculationHome page
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
Circulation, May 27, 2008; 117(21): e350 - e408.
[Full Text] [PDF]


Home page
EuropaceHome page
M. E.W. Hemels, J. H. Ruiter, G. P. Molhoek, N. J.G.M. Veeger, A. C.P. Wiesfeld, A. V. Ranchor, M. van Trigt, A. Pilmeyer, I. C. Van Gelder, and for The Features in AT500TM study; Chances for pat
Right atrial preventive and antitachycardia pacing for prevention of paroxysmal atrial fibrillation in patients without bradycardia: a randomized study
Europace, March 1, 2008; 10(3): 306 - 313.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
L. Mont, R. Ruiz-Granell, J. G. Martinez, J. R. Carmona, M. Fidalgo, E. Cobo, M. Riera, X. Navarro, and on behalf of the Prevention or Termination (POT) S
Impact of anti-tachycardia pacing on atrial fibrillation burden when added on top of preventive pacing algorithms: results of the prevention or termination (POT) trial
Europace, January 1, 2008; 10(1): 28 - 34.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. W. Israel
Studying atrial fibrillation: what can we learn from the AFTherapy study?
Europace, December 1, 2007; 9(12): 1107 - 1109.
[Full Text] [PDF]


Home page
EuropaceHome page
A.J. Camm, N. Sulke, N. Edvardsson, P. Ritter, B.A. Albers, J.H. Ruiter, T. Lewalter, P.A. Capucci, E. Hoffmann, and on behalf of the AFTherapy investigators
Conventional and dedicated atrial overdrive pacing for the prevention of paroxysmal atrial fibrillation: the AFTherapy study
Europace, December 1, 2007; 9(12): 1110 - 1118.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
L. Padeletti, P. Pieragnoli, V. Jentzen, and A. Schuchert
The comorbidity of atrial fibrillation and heart failure: a challenge for electrical therapies
Eur. Heart J. Suppl., December 1, 2007; 9(suppl_I): I81 - I86.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. W. Israel
What is the role of the pacing rate in the prevention of atrial tachyarrhythmias?
Europace, November 1, 2007; 9(11): 999 - 1001.
[Full Text] [PDF]


Home page
EuropaceHome page
B. K. Kantharia, R. A. Freedman, D. Hoekenga, G. Tomassoni, S. Worley, R. Sorrentino, D. Steinhaus, J. M. Wolkowicz, Z. A. Syed, and and the AOP Study Investigators
Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study
Europace, November 1, 2007; 9(11): 1024 - 1030.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Europace, October 1, 2007; 9(10): 959 - 998.
[Full Text] [PDF]


Home page
Eur Heart JHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Eur. Heart J., September 2, 2007; 28(18): 2256 - 2295.
[Full Text] [PDF]


Home page
EuropaceHome page
S. Petrutiu, A. V. Sahakian, and S. Swiryn
Abrupt changes in fibrillatory wave characteristics at the termination of paroxysmal atrial fibrillation in humans
Europace, July 1, 2007; 9(7): 466 - 470.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
N. Sulke, J. Silberbauer, L. Boodhoo, N. Freemantle, K. Kamalvand, S. O'Nunain, D. Hildick-Smith, G. W. Lloyd, N. R. Patel, and V. Paul
The use of atrial overdrive and ventricular rate stabilization pacing algorithms for the prevention and treatment of paroxysmal atrial fibrillation: the Pacemaker Atrial Fibrillation Suppression (PAFS) study
Europace, June 11, 2007; (2007) eum111v1.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. H. Schoenfeld
Contemporary Pacemaker and Defibrillator Device Therapy: Challenges Confronting the General Cardiologist
Circulation, February 6, 2007; 115(5): 638 - 653.
[Full Text] [PDF]


Home page
EuropaceHome page
Writing Committee Members, V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, et al.
ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Europace, September 1, 2006; 8(9): 651 - 745.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
J. Am. Coll. Cardiol., August 15, 2006; 48(4): e149 - e246.
[Full Text] [PDF]


Home page
CirculationHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
Circulation, August 15, 2006; 114(7): e257 - e354.
[Full Text] [PDF]


Home page
EuropaceHome page
M. Gulizia, S. Mangiameli, S. Orazi, G. Chiaranda, G. Boriani, G. Piccione, N. DiGiovanni, A. Colletti, C. Puntrello, G. Butera, et al.
Randomized comparison between Ramp and Burst+ atrial antitachycardia pacing therapies in patients suffering from sinus node disease and atrial fibrillation and implanted with a DDDRP device
Europace, July 1, 2006; 8(7): 465 - 473.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
P. Azzolini, G. Critelli, V. De Giorgi, G. B. Del Giudice, G. Ibba, D. Melissano, A. Scaccia, and A. Puglisi
Atrial tachyarrhythmia burden modelling by some electrophysiological parameters in pacemaker-recipient patients with Brady-Tachy syndrome
Europace, July 1, 2006; 8(7): 474 - 481.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. Drago, M. S. Silvetti, G. Grutter, and A. De Santis
Long term management of atrial arrhythmias in young patients with sick sinus syndrome undergoing early operation to correct congenital heart disease
Europace, July 1, 2006; 8(7): 488 - 494.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Hoffmann, N. Sulke, N. Edvardsson, J. Ruiter, T. Lewalter, A. Capucci, A. Schuchert, S. Janko, J. Camm, and on behalf of the Atrial Fibrillation Therapy (AFT)
New Insights Into the Initiation of Atrial Fibrillation: A Detailed Intraindividual and Interindividual Analysis of the Spontaneous Onset of Atrial Fibrillation Using New Diagnostic Pacemaker Features
Circulation, April 25, 2006; 113(16): 1933 - 1941.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. Gulizia, S. Mangiameli, G. Chiaranda, V. Spadola, N. Di Giovanni, A. Colletti, V. Bulla, A. Circo, O. Pensabene, L. Vasquez, et al.
Design and rationale of a randomized study to compare amiodarone and Class IC anti-arrhythmic drugs in terms of atrial fibrillation treatment efficacy in patients paced for sinus node disease: the PITAGORA trial.
Europace, April 1, 2006; 8(4): 302 - 305.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. E.W. Hemels, A. C.P. Wiesfeld, B. Inberg, P. F.H.M. Van Dessel, W. Nieuwland, E. S. Tan, H. Mulder, D. J. Van Veldhuisen, and I. C. Van Gelder
Right atrial overdrive pacing for prevention of symptomatic refractory atrial fibrillation.
Europace, February 1, 2006; 8(2): 107 - 112.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
N. Musilli and L. Padeletti
Pacemaker selection: time for a rethinking of complex pacing systems?
Eur. Heart J., January 2, 2006; 27(2): 132 - 135.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Capucci, M. Santini, L. Padeletti, M. Gulizia, G. Botto, G. Boriani, R. Ricci, S. Favale, F. Zolezzi, N. Di Belardino, et al.
Monitored Atrial Fibrillation Duration Predicts Arterial Embolic Events in Patients Suffering From Bradycardia and Atrial Fibrillation Implanted With Antitachycardia Pacemakers
J. Am. Coll. Cardiol., November 15, 2005; 46(10): 1913 - 1920.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
B. P. Knight, B. J. Gersh, M. D. Carlson, P. A. Friedman, R. L. McNamara, S. A. Strickberger, H. F. Tse, A. L. Waldo, and for the AHA Writing Group
Role of Permanent Pacing to Prevent Atrial Fibrillation: Science Advisory From the American Heart Association Council on Clinical Cardiology (Subcommittee on Electrocardiography and Arrhythmias) and the Quality of Care and Outcomes Research Interdisciplinary Working Group, in Collaboration With the Heart Rhythm Society
Circulation, January 18, 2005; 111(2): 240 - 243.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Padeletti, M. Santini, G. Boriani, G. Botto, A. Capucci, M. Gulizia, R. Ricci, A. Spampinato, P. Pieragnoli, E. Warman, et al.
Temporal variability of atrial tachyarrhythmia burden in bradycardia-tachycardia syndrome patients
Eur. Heart J., January 2, 2005; 26(2): 165 - 172.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. Vollmann, E. Kollet, L. Lüthje, S. Busse, and C. Unterberg
Comparison of immediate and delayed automatic antitachycardia pacing for the termination of atrial tachyarrhythmias
Europace, January 1, 2005; 7(3): 248 - 254.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. Flammang, V. Loteanu, D. Hamani, M. Lambiez, and G. Flammang-Dorie
Brady-tachy syndrome: Rapid atrial pacing efficacy in preventing atrial fibrillation recurrence assessed by reliable electrograms: the prefib pilot study
Europace, January 1, 2005; 7(5): 482 - 489.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
P. Zimetbaum and M. E. Josephson
Is There a Role for Maintaining Sinus Rhythm in Patients with Atrial Fibrillation?
Ann Intern Med, November 2, 2004; 141(9): 720 - 726.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. R.J. Mitchell and N. Sulke
How do atrial pacing algorithms prevent atrial arrhythmias?
Europace, January 1, 2004; 6(4): 351 - 362.
[Abstract] [Full Text] [PDF]