Advertisement





Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2002; 40:1479-1486
© 2002 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gilon, D.
Right arrow Articles by Levine, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gilon, D.
Right arrow Articles by Levine, R. A.

CLINICAL STUDY: ECHOCARDIOGRAPHIC METHODS

Effect of three-dimensional valve shape on the hemodynamics of aortic stenosis

Three-dimensional echocardiographic stereolithography and patient studies

Dan Gilon, MD, FACC*,*, Edward G. Cape, PhD{dagger}, Mark D. Handschumacher, BS*, Jae-Kwan Song, MD, FACC{ddagger}, Joan Solheim{ddagger}, Michael VanAuker, BS{dagger}, Mary Etta E. King, MD, FACC* and Robert A. Levine, MD, FACC*

* Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
{dagger} Children’s Hospital, School of Medicine and Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
{ddagger} Santin Engineering, Peabody, Massachusetts, USA

Manuscript received October 29, 2001; revised manuscript received June 6, 2002, accepted July 2, 2002.

* Reprint requests and correspondence: Dr. Dan Gilon, Cardiac Ultrasound Laboratory, VBK508, Massachusetts General Hospital, 32 Fruit Street, Boston, Massachusetts, USA 02114.
gilond{at}cc.huji.ac.il


    Abstract
 Top
 Abstract
 Basic principles
 Methods
 Results
 Discussion
 References
 
OBJECTIVES: This study tested the hypothesis that the impact of a stenotic aortic valve depends not only on the cross-sectional area of its limiting orifice but also on three-dimensional (3D) valve geometry.

BACKGROUND: Valve shape can potentially affect the hemodynamic impact of aortic stenosis by altering the ratio of effective to anatomic orifice area (the coefficient of orifice contraction [Cc]). For a given flow rate and anatomic area, a lower Cc increases velocity and pressure gradient. This effect has been recognized in mitral stenosis but assumed to be absent in aortic stenosis (constant Cc of 1 in the Gorlin equation).

METHODS: In order to study this effect with actual valve shapes in patients, 3D echocardiography was used to reconstruct a typical spectrum of stenotic aortic valve geometrics from doming to flat. Three different shapes were reproduced as actual models by stereolithography (computerized laser polymerization) with orifice areas of 0.5, 0.75, and 1.0 cm2 (total of nine valves) and studied with physiologic flows. To determine whether valve shape actually influences hemodynamics in the clinical setting, we also related Cc (= continuity/planimeter areas) to stenotic aortic valve shape in 35 patients with high-quality echocardiograms.

RESULTS: In the patient-derived 3D models, Cc varied prominently with valve shape, and was largest for long, tapered domes that allow more gradual flow convergence compared with more steeply converging flat valves (0.85 to 0.90 vs. 0.71 to 0.76). These variations translated into differences of up to 40% in pressure drop for the same anatomic area and flow rate, with corresponding variations in Gorlin (effective) area relative to anatomic values. In patients, Cc was significantly lower for flat versus doming bicuspid valves (0.73 ± 0.14 vs. 0.94 ± 0.14, p < 0.0001) with 40 ± 5% higher gradients (p < 0.0001).

CONCLUSIONS: Three-dimensional valve shape is an important determinant of pressure loss in patients with aortic stenosis, with smaller effective areas and higher pressure gradients for flatter valves. This effect can translate into clinically important differences between planimeter and effective valve areas (continuity or Gorlin). Therefore, valve shape provides additional information beyond the planimeter orifice area in determining the impact of valvular aortic stenosis on patient hemodynamics.

Abbreviations and Acronyms
  Aanat
  anatomic orifice area
  Aeff
  effective orifice area
  Cc
  coefficient of contraction
  PG
  pressure gradient
  3D
  three-dimensional
  Q
  flow rate


The hemodynamic impact of valvular stenosis is determined primarily by the effective orifice area (Aeff) seen by flow, which differs from anatomic orifice area (Aanat). This distinction has been recognized in mitral stenosis but assumed to be absent in aortic stenosis, with little investigation to date. Understanding these differences is important in clinical applications now that anatomic planimetry is more feasible and common in patients with aortic stenosis; this understanding is required to relate anatomic measures to Aeff by the continuity or Gorlin equation, which will in turn provide physicians with a consistent classification system for evaluating severity of stenosis (1). Therefore, we explored the relation between Aanat and Aeff for aortic stenosis, using three-dimensional (3D) echocardiography (2–24) to provide actual valve geometries derived from patients for precise testing in the controlled in vitro environment. The transition from patient data to flow models was made by laser stereolithography, which reproduces 3D shapes as solid objects (25,26). Using these techniques, we addressed the hypothesis that, for a given two-dimensional limiting Aanat, overall 3D leaflet geometry importantly modifies the Aeff seen by flow and the resulting pressure loss, which determines the work load imposed on the left ventricle. The influence of valve shape on Aeff was then confirmed in the clinical setting by comparing Aeff and Aanat in patients with a spectrum of valve shape.


    Basic principles
 Top
 Abstract
 Basic principles
 Methods
 Results
 Discussion
 References
 
The effect of valve shape on flow can be expressed by the coefficient of orifice contraction, which is the ratio of Aeff at the vena contracta (the smallest cross-sectional area encountered by flow) to the Aanat. Flow, directed to converge toward a narrow orifice, will continue to converge beyond it until interaction with surrounding fluid causes divergence (27–33). A relatively flat valve produces steep flow convergence both toward and beyond the orifice, leading to a smaller Aeff and coefficient of contraction (Cc) (Fig. 1). This is important because, for a given flow rate and anatomic area, a smaller effective area would predict a higher velocity and therefore a higher pressure gradient (PG), which is proportional to velocity squared (34,35). In contrast, a tube has no flow convergence toward or beyond the orifice, giving a larger Aeff and a contraction coefficient of 1.0 and, therefore, a lower velocity and PG for the same flow rate and anatomic area. A gradually doming valve would lie between these extremes. Also, the Gorlin equation is widely assumed to convert effective to Aanat (with the original aim of surgical validation), but uses a constant contraction coefficient of 1.0 for aortic stenosis (36); if this coefficient varies with valve shape (37), so would the relation between Gorlin and anatomic areas. To date, these concepts could not be tested with the actual 3D shapes of valves in patients; 3D echocardiography with stereolithography now permits this.



View larger version (25K):
[in this window]
[in a new window]
 
Figure 1 Convergence of flow beyond the anatomic orifice to form the effective orifice area is determined by the convergence pattern established by valve shape. Ao = aorta; Cc = coefficient of contraction; LV = left ventricle.

 

    Methods
 Top
 Abstract
 Basic principles
 Methods
 Results
 Discussion
 References
 
Patient-derived 3D valve models.   A spark gap (audible sound) transducer locating system (4,9,10,13,14) with respiratory and electrocardiographic gating was used in patients to reconstruct three leaflet geometries spanning the range typically seen in patients with significant aortic stenosis (Fig. 2) : a relatively immobile valve with the flattest leaflet geometry, as seen in calcific aortic stenosis; an intermediate, funnel-like valve with less mobile leaflets; and a doming valve with more mobile leaflets, characteristic of bicuspid valves. The aortic valve was scanned with a 3.5 MHz transducer (Hewlett-Packard, Andover, Massachusetts) in parasternal short- and long-axis or rotated apical views to visualize the entire leaflet surface. Two-dimensional images and their spatial locations were automatically combined by computer and digitally encoded (13). The ventricular surfaces of the aortic leaflets were traced and reconstructed from 24 intersecting views at a consistent point in the respiratory and cardiac cycles to reflect maximal systolic leaflet opening. The traces were then fitted to form a continuous 3D leaflet surface using a previously validated polyhedral algorithm (13).



View larger version (81K):
[in this window]
[in a new window]
 
Figure 2 Parasternal long-axis two-dimensional echo views showing the clinical spectrum of leaflet shapes from flattest (upper left) to intermediate (upper right) to most doming (below). The arrows perpendicular to the leaflet surface emphasize the transition from individually flatter to most curved shapes. Ao = aorta; LA = left atrium; LV = left ventricle.

 
For each of the three valve shapes derived from patients, three exact models were constructed by stereolithography and machined to have Aanat of 0.5, 0.75, and 1.0 cm2. Stereolithography (3D Systems, Valencia, California), an industrial process for constructing prototypes from computer designs, uses laser light to induce polymerization of a liquid substrate to form successive solid layers (25,26). The Aanat was confirmed by planimetry of direct video images of the orifices. Each of these nine valve models was then studied using an aqueous glycerin solution (33%) with physiologic viscosity and density; three instantaneous steady flow rates of 3 to 18 l/min were used for each orifice area to provide a physiologic range of orifice velocities from 1 to 3 m/s (based on anatomic area) for all valves. Flow rates were provided by a calibrated rotameter pump and confirmed by timed volumetric collection. Effective orifice area was calculated as flow rate divided by continuous wave Doppler orifice velocity (the maximal velocity at the vena contracta). The Cc was calculated as effective divided by Aanat. The PG was measured directly using a manometer. Gorlin valve area was calculated as flow rate divided by a constant (44.5) times the square root of the mean PG, based on the originally assumed contraction coefficient of 1.0 (27,28).

Clinical studies
We aimed to determine whether the hemodynamic effects of 3D aortic valve shape can actually be demonstrated in the clinical setting, and tested the hypothesis that the shape of a stenotic valve affects its contraction coefficient. This hypothesis can be tested noninvasively using cardiac ultrasound and Doppler to measure the Aanat by planimetry in patients with suitable high-quality images and to calculate effective orifice area by the continuity equation.

We addressed this hypothesis retrospectively with transthoracic echocardiography because transesophageal echocardiography studies are not routinely performed to assess stenotic aortic valve area. We reviewed 240 consecutive patients with significant aortic stenosis, defined as continuity area of ≤1 cm2, and selected 35 with especially high-quality echocardiographic studies to permit planimetry of the limiting orifice area. These included 14 patients with doming bicuspid valves and 21 with flat tricuspid aortic valves (mean age = 35 ± 18 years vs. 78 ± 8 years, p < 0.0001; 8 men and 6 women vs. 14 men and 7 women, p = NS). Doming was defined by restricted leaflet tip motion with preserved mobility of the leaflet bodies, making each leaflet concave toward the left ventricle (Fig. 2). In the flat valve shape, the leaflets appeared individually flat, with a more triangular systolic configuration in the long-axis view. The Aanat was obtained by planimetry of the inner margins of the limiting orifice in mid-systole in a parasternal short-axis view (average of three measurements). Peak systolic flow rate across the valve was obtained as the product of subvalvular area at the level of the aortic annulus, calculated as ({pi}/4) x diameter squared, multiplied by peak subvalvular velocity by pulsed Doppler. The Aeff at peak flow rate was calculated as flow rate divided by peak orifice velocity by continuous-wave Doppler. The contraction coefficient was then calculated as the ratio of effective to anatomic areas.

Data and statistical analysis
Patient-derived 3D models
Two-way analysis of variance was used to test for significant differences among Cc as a function of both 3D shape and orifice area.

To test for the relation between PG and valve shape for valves of different anatomic areas at different flow rates, each PG was first normalized to that for a doming valve of the same Aanat and flow rate (Q); these normalized values were then evaluated as a function of valve shape, expressed by the squared ratio of (Cc for the doming valve/Cc for the valve being tested). Because of the reciprocal relation between PG and Cc2: PG = 4v2 by Bernoulli (v = velocity) = 4(Q/Aanat x Cc)2 by continuity. This relation between normalized PG and Cc2 ratios was tested by linear regression analysis. Also, because area (Gorlin)/area (anat) = Cc (actual)/Cc (assumed), and Cc was assumed to be constant and equal to 1 by Gorlin, we tested the relation of area (Gorlin)/area (anat) to Cc (actual) by linear regression analysis.

Clinical studies
Anatomic area, effective area, and contraction coefficients in the patient groups with doming and flat valves were compared by t test. To determine whether differences in effective area translate into differences in PG, the peak PG was normalized for its determinants other than valve shape (flow rate and anatomic area) and compared between the two groups: PG = 4v2 = 4Q2/area (eff)2, so PG (normalized for flow rate) = PG/Q2; PG = 4v2 = 4Q2/Cc2 area (anat)2, so PG (normalized for flow rate and anatomic area) = (PG/Q2) x area (anat)2.


    Results
 Top
 Abstract
 Basic principles
 Methods
 Results
 Discussion
 References
 
Patient-derived 3D models.   Valve shapes
Figures 3A and 3B show the flattest reconstructed valve viewed from the side with the surface fitted to the leaflets in yellow, and then the corresponding stereolithography model. Figures 3C and 3D show the intermediate doming valve as traces and bulging surface, with the corresponding model shape. Figures 3E and 3F show the valve with the longest dome (compare Fig. 2 bottom) and its associated model, with the elliptical bicuspid valve orifice at the apex of the dome.




View larger version (205K):
[in this window]
[in a new window]
 
Figure 3 (A) Three-dimensional (3D) reconstruction of the flattest valve studied, in a long-axis perspective viewed from the aorta, with the fitted valve surface (yellow) superimposed on the traces of valve (green) and left ventricular (LV) outflow tract (pink). (B) Corresponding stereolithography model. (C) 3D reconstruction of a doming valve of intermediate shape, with fitted valve surface (yellow) superimposed on valve traces, and the LV outflow tract to the left. (D) Corresponding stereolithography model.

(E and F) 3D reconstruction of the valve with the longest dome (compare Fig. 2 bottom), with associated model.

 
Cc
Figure 4 shows the coefficients of contraction for the valve shapes and orifice sizes studied. Analysis of variance showed significant differences in the coefficient among the different valve shapes and anatomic areas (p < 0.0001). The Cc was smallest for the flattest valve shape, because the steep flow convergence proximal to the limiting orifice causes flow to continue to converge steeply beyond it, most like a flat plate. Coefficients were largest for the tapered shapes, because the more gradual flow convergence within the funnel produces less contraction beyond the orifice, closer to the limit of 1.0 for a straight tube. The longest dome (Fig. 3E) favored the most gradual flow convergence over the longest path, and therefore the highest contraction coefficients. Also, for each shape, the coefficient increased as the orifice size increased (the size of the inlet being constant), making the entire structure more like a tube with less steep flow convergence. The values in Figure 4 represent the mean for each valve over the three flow rates studied, because there was minimal variation of coefficient with flow rate over the range of flows studied; linear regression showed no significant relation between coefficient and flow rate for each valve studied.



View larger version (13K):
[in this window]
[in a new window]
 
Figure 4 Coefficients of contraction according to valve shape and orifice size.

 
PGs and Gorlin areas
Direct pressure measurements confirmed that these variations in contraction coefficient translated into corresponding changes in PG. For each Aanat and flow rate, the PG was highest for the flattest valve, which had the smallest effective area and, therefore, the highest velocity and PG. The PGs for the flattest valves were 40 ± 5% higher relative to the most domed valves for the same anatomic area and flow rate; gradients were 14 ± 2.6% higher for the intermediate versus most domed valves (all p < 0.0001). This ratio of PG to the PG of a corresponding dome correlated well with the squared ratio of the contraction coefficients, expressing the differences in valve shape (y = 0.94x + 0.69, r = 0.99, SEE = 0.021). The calculated Gorlin valve areas derived from these pressures also had a variable relation to the actual anatomic areas, spanning a 20% range, because the original Gorlin equation assumes a constant contraction coefficient. The ratio of Gorlin to anatomic area correlated with the Cc, because the basic Gorlin equation is designed to provide an Aeff (y = 1.05 x + 0.06, r = 0.89, SEE = 0.04).

Clinical studies
In the entire group of 35 patients, there was no significant difference in Aanat between those with flat and domed valves (0.96 ± 0.24 cm2 vs. 0.95 ± 0.25 cm2); Aeff, however, was significantly smaller for the flat valves than the doming ones, averaging 0.69 ± 0.17 cm2 versus 0.86 ± 0.13 cm2 (p < 0.001). Therefore, the contraction coefficients were significantly smaller in patients with flat versus doming valves, with an average of 0.73 ± 0.14 versus 0.94 ± 0.14 (p < 0.001). Of note, the contraction coefficients for the flat and domed stereolithography models lay within the range of values for the corresponding clinical study groups: 0.71 to 0.76 for the flattest models and 0.85 to 0.90 for the most doming. The smaller effective areas in patients with flat valves translated into higher peak PGs, expressed as gradients normalized for flow rate (10.0 ± 4.7 vs. 5.8 ± 2.1 mm Hg per flow rate [in cm3/s] squared for the flat vs. the doming valves, p = 0.004), and normalized for both flow rate and Aanat to express the effect of shape alone (8.1 ± 3.9 vs. 4.7 ± 1.7 [mm Hg/(cm3/s)2] x (cm2)2 for flat vs. doming valves, p = 0.005).


    Discussion
 Top
 Abstract
 Basic principles
 Methods
 Results
 Discussion
 References
 
The results of this study demonstrate that the impact of a stenotic aortic valve on pressures and flows in the heart depends not only on the cross-sectional area of the limiting orifice but also on the 3D geometry of the valve leaflets proximal to the orifice.

This geometry directs the pattern of flow convergence toward and beyond the orifice and, therefore, determines the relation between the Aanat and the Aeff, which fundamentally influences flow. Patients with flat valves and steeper flow convergence have smaller Aeff than those with more gradually tapering domed valves for the same anatomic area and flow rate: corresponding pressure losses are increased by 40% or more, generating increased ventricular work loads. There is corresponding variation of the calculated Gorlin area relative to the anatomic area, reflecting the basic derivation of the Gorlin as an Aeff.

Aortic versus mitral stenosis.   Although this effect of valve shape on contraction coefficient has been recognized in mitral stenosis (25), it has long been assumed to be unimportant for aortic stenosis, with a constant contraction coefficient of 1 used in the Gorlin equation. This study demonstrates these effects are, in fact, important, especially for the flattest aortic valves, for which the contraction coefficient falls into the range seen with doming mitral valves.

These effects of valve shape on flow have been established in vitro, where precise and direct measurements of anatomic orifice areas and flow rates can be made using actual geometries from patients derived by 3D echo and reproduced by stereolithography. These findings have been confirmed in correlative clinical studies.

Clinical implications: planimeter versus effective areas
In patients, this understanding should be of value in comparing planimeter anatomic versus effective valve areas by the continuity or Gorlin equations (1,27,38). These measures are evaluated relative to cutoff values commonly used to demarcate significant and critical stenosis in routine clinical practice. Reconciling differences between measures of anatomic and effective area could be important, therefore, in providing a unified and consistent evaluation relevant to the clinical presentation. Bernard et al. (1), for example, found clinically important overestimation by transesophageal echocardiography planimetry of valve areas compared with Gorlin and Doppler effective areas in patients (1). This overestimation was greater for smaller valves (<0.9 cm2), which in clinical experience tend to be flatter. The authors state that these discrepancies are "unacceptable in clinical practice, as the need for surgery is decided on a very narrow range of aortic valve area values" (1). Our patient studies similarly show important differences in effective area (0.69 vs. 0.86 cm2) for comparable anatomic areas but different shapes. This may be particularly important with increasing prevalence of calcific (flat) stenosis with age, making it prudent not to exclude severe stenosis by planimetry in the face of small Gorlin or continuity areas; cutoffs for severity classification may also need to be reconsidered in that context. In addition, these observations could potentially and partially explain differences in clinical presentation in patients with the same anatomic areas but different valve shapes, and are also important in view of the prognostic value of aortic valve area (39).

Implications for fluid flow
The need for such studies has been pointed out by Gorlin himself, who asked whether "flow lines approach the valve smoothly as through a funnel, or abruptly as toward a window in a wall," suggesting that such variations might "alter the orifice constant, perhaps drastically " (37). (Such variations, for example, may have been reflected in the change from the original mitral stenotic contraction coefficient of 0.7 to the subsequent 0.85 [27,28] possibly because of differences among patient groups). Flow dependence of the contraction coefficient (40) was not apparent over the flow rates studied, consistent with the findings that flow dependence is limited to low flows (41,42) or negligible (43).

Another way of stating the results is that for a given anatomic orifice area and pressure gradient, doming valves permit a higher cardiac output than flat ones. This is analogous to the observations of Grayburn et al. (44) that slitlike aortic insufficiency orifices typical of bicuspid and degenerative disease permit more regurgitant flow (larger Aeff) than central rheumatic or circular orifices for the same anatomic orifice and PG.

The adverse effect of flat shape on pressure losses could also in principle be magnified because the smaller vena contracta, in relation to the aortic root, can increase turbulent losses and decrease pressure recovery (45,46).

This study also demonstrates the value of stereolithography based upon 3D echocardiographic imaging (25,26) as a technique for providing hemodynamic insights of importance for clinical evaluation.

Study limitations and future directions
The 3D technique has been extensively validated in vitro and in vivo (9,13,17,18), and the resolution of spark gap localization is <1 mm (10,13); variability has been reduced in this study by respiratory registration. Although the aortic valve deforms as it opens, the fixed models used capture funnel shape at the time of maximal leaflet distension for all valves, roughly corresponding to the time of peak velocity and gradient, to isolate the effect of valve shape at that moment. Future studies could examine deformable models and any second-degree effects of pulsatile flow on the evolution of the contraction coefficient that might modulate the main geometric effects described, but not alter them, given the absence of significant effects of flow rate on the contraction coefficient over the range of flows studied. It is interesting to speculate that some of the improvement in valve area seen with dobutamine in patients with low-flow states (47,48) may reflect a further benefit of improved valve shape: increased leaflet tip excursion could change shape from flat toward funnel, increasing contraction coefficient and effective area. As in the case of mitral valve prolapse (9), although investigation requires full 3D studies, the resulting insights ultimately have the potential to be applied on the basis of correlated two-dimensional images. Finally, it was not the intent of this study to examine all possible valve shapes, but rather selected ones covering the spectrum seen in patients.

In conclusion, therefore, the coefficient of orifice contraction for stenotic aortic valves is affected by the variations in leaflet geometry seen in patients and reconstructed by 3D echocardiography, translating into important differences in the pressure drop induced by these valves. Three-dimensional valve shape, therefore, provides additional information beyond the planimeter orifice area in determining the impact of aortic stenosis on patient hemodynamics. This effect can translate into clinically important differences between planimeter and effective valve areas (continuity or Gorlin). Stereolithography, using data generated by 3D echocardiography, can allow us to address such uniquely 3D questions using actual information from patients to provide insight into the relation among structure, pressure, and flows in the heart, relevant to the clinical setting.


    Footnotes
 
Supported in part by grants R01 HL53702, HL38176, and K24 HL64697 of the National Institutes of Health, Bethesda, Maryland (Dr. Levine). Dr. Gilon was a Research Fellow from Hadassah University Hospital and Medical School, Jerusalem, and was supported in part by a grant from the American Physicians Fellowship for Medicine in Israel. On the basis of this study, Dr. Gilon received a Young Investigator Award of the American College of Cardiology. Dr. Levine was an Established Investigator of the American Heart Association, Dallas, Texas. Dr. Gilon is presently affiliated with the Heart Institute, Hadassah University Hospital, Faculty of Medicine, Hebrew University, in Jerusalem, Israel.


    References
 Top
 Abstract
 Basic principles
 Methods
 Results
 Discussion
 References
 
1. Bernard Y, Meneveau N, Vuillemenot A, et al. Planimetry of aortic valve area using multiplane transesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis. Heart. 1997;78:68–73[Abstract/Free Full Text]

2. Geiser EA, Ariet M, Conetta DA, et al. Dynamic three-dimensional echocardiographic reconstruction of the intact human left ventricle: technique and initial observations in patients. Am Heart J. 1982;103:1056–1065[CrossRef][Medline]

3. Ghosh A, Nanda NC, Maurer G. Three-dimensional reconstruction of echocardiographic images using the rotation method. Ultrasound Med Biol. 1982;8:655–661[CrossRef][Medline]

4. Moritz WE, Pearlman AS, McCabe DH, et al. An ultrasound technique for imaging the ventricle in three-dimensions and calculating its volume. IEEE Trans Biomed Eng. 1983;30:482–491[Medline]

5. Nixon JV, Saffer SI, Lipscomb K, et al. Three-dimensional echocardiography. Am Heart J. 1983;106:435–443[CrossRef][Medline]

6. Sapoznikov D, Fine DG, Mosseri M, et al. Left ventricular shape, wall thickness, and function based on three-dimensional reconstruction echocardiography. Comput Cardiol. 1987;:495–498

7. Collins SM, Chandran KB, Skorton DJ. Three-dimensional cardiac imaging. Echocardiography. 1988;5:311–319

8. Martin RM, Graham MM, Kao R, et al. Measurement of left ventricular ejection fraction and volumes with three-dimensional reconstructed transesophageal ultrasound scans: comparison to radionuclide dilution measurements. J Cardiothoracic Anesth. 1989;3:260–268[CrossRef][Medline]

9. Levine RA, Handschumacher MD, Sanfilippo AJ, et al. Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. Circulation. 1989;80:589–598[Abstract/Free Full Text]

10. King DLKing DL Jr., Shao MYC. Three-dimensional spatial registration and interactive display of position and orientation of real-time ultrasound images. J Ultrasound Med. 1990;9:525–532[Abstract]

11. Gopal AS, King DL, Katz J, et al. Three-dimensional echocardiographic volume computation by polyhedral surface reconstruction: in vitro validation and comparison to magnetic resonance imaging. J Am Soc Echocardiogr. 1992;5:115–124[Medline]

12. Pandian NG, Nanda NC, Schwartz SL, et al. Three-dimensional and four-dimensional transesophageal echocardiographic imaging of the heart and aorta in humans using a computed tomographic imaging probe. Echocardiography. 1992;9:677–687[Medline]

13. Handschumacher MD, Lethor JP, Siu SC, et al. A new integrated system for three-dimensional reconstruction: development and validation for ventricular volume with application in human subjects. J Am Coll Cardiol. 1993;21:743–753[Abstract]

14. Sapin PM, Schroeder KD, Smith MD, et al. Three-dimensional echocardiographic measurements of left ventricular volume in vitro: comparison with two-dimensional echocardiography and cineventriculography. J Am Coll Cardiol. 1993;22:1530–1537[Abstract]

15. Pearlman AS. Measurement of left ventricular volume by three-dimensional echocardiography—present promise and potential problems. J Am Coll Cardiol. 1993;22:1538–1540[Medline]

16. Belohlavek M, Foley DA, Gerber TC, et al. Three-dimensional ultrasound imaging of the atrial septum: normal and pathologic anatomy. J Am Coll Cardiol. 1993;22:1673–1678[Abstract]

17. Siu SC, Rivera JM, Guerrero JL, et al. Three-dimensional echocardiography: in vivo validation for left ventricular volume and function. Circulation. 1993;88:1715–1723[Abstract/Free Full Text]

18. Jiang L, Vazquez de Prada JA, et al. Quantitative three-dimensional reconstruction of aneurysmal left ventricles. Circulation. 1995;91:222–230[Abstract/Free Full Text]

19. Marx GR, Fulton DR, Pandian NG, et al. Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography. J Am Coll Cardiol. 1995;25:482–490[Abstract]

20. Buck T, Hunold P, Wentz KU, Tkalec W, Nesser HJ, Erbel R. Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm: comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography. Circulation. 1997;96:4286–4297[Abstract/Free Full Text]

21. Kardon RE, Cao QL, Masani N, et al. New insights and observations in three-dimensional echocardiographic visualization of ventricular septal defects: experimental and clinical studies. Circulation. 1998;98:1307–1314[Abstract/Free Full Text]

22. Mele D, Fehske W, Pratola C, et al. A simplified, practical approach for three-dimensional echocardiographic reconstruction of the left ventricle: clinical application in patients with abnormally shaped hearts. J Am Soc Echocardiogr. 1998;11:1001–1012[CrossRef][Medline]

23. Menzel T, Mohr-Kahaly S, Kolsch B, et al. Quantitative assessment of aortic stenosis by three-dimensional echocardiography. J Am Soc Echocardiogr. 1997;10:215–223[CrossRef][Medline]

24. Ge S, Warner JG Jr., Abraham TP, et al. Three-dimensional surface area of the aortic valve orifice by three-dimensional echocardiography: clinical validation of a novel index for assessment of aortic stenosis. Am Heart J. 1998;136:1042–1050[CrossRef][Medline]

25. Gilon D, Cape EG, Handschumacher MD, et al. Insights from three-dimensional echocardiographic laser stereolithography: effect of leaflet funnel geometry on the coefficient of orifice contraction, pressure loss, and the Gorlin formula in mitral stenosis. Circulation. 1996;94:452–459[Abstract/Free Full Text]

26. Binder TM, Moertl D, Rehak G, et al. Stereolithographic biomodeling to create tangible hard copies of cardiac structures from echocardiographic in vitro and in vivo validation. J Am Coll Cardiol. 2000;35:230–237[Abstract/Free Full Text]

27. Gorlin R, Gorlin SG. Hydraulic formula for calculations of the area of the stenotic mitral valve, other cardiac valves, and central circulation shunts. Am Heart J. 1951;41:1–29[CrossRef][Medline]

28. Cohen MV, Gorlin R. Modified orifice equation for the calculations of mitral valve area. Am Heart J. 1972;84:839–840[CrossRef][Medline]

29. Gorlin WB, Gorlin R. A generalized formulation of the Gorlin formula for calculating the area of the stenotic mitral valve and other stenotic cardiac valves. J Am Coll Cardiol. 1990;15:246–247[Medline]

30. Fox R, McDonald TA. Incompressible viscous flow. In: Introduction to Fluid Mechanics. 2nd ed. New York, NY: John Wiley and Sons, 1978:447–9

31. Daugherty RL, Franzini JB, Finnemore EJ. Fluid measurements. In: Fluid Mechanics With Engineering Applications. 2nd ed. New York, NY: McGraw-Hill, 1985:399–446

32. Sugawara M. Stenosis: theoretical background and clinical measurements. Sugawara M, Kajiya F, Kitabatake A, Matsuo H. Blood Flow in the Heart and Large Vessels. Tokyo, Japan: Springer-Verlag; 1989. p. 105–131

33. Flachskampf FA, Weyman AE, Guererro JL, Thomas JD. Influence of orifice geometry and flow rate on effective valve area: an in vitro study. J Am Coll Cardiol. 1990;15:1173–1180[Abstract]

34. Hatle L, Angelsen B. Doppler Ultrasound in Cardiology. 2nd ed. Philadelphia, PA: Lea and Febiger, 1985:22–6

35. Valdes-Cruz LM, Yoganathan AP, Tamura T, Tomizuka F, Woo YR, Sahn DJ. Studies in vitro of the relationship between ultrasound and laser Doppler velocimetry and applicability of the simplified Bernoulli relationship. Circulation. 1986;73:300–308[Abstract/Free Full Text]

36. Carabello BA, Grossman W. Calculation of stenotic valve orifice area. Grossman W, Baim DS. Cardiac Catheterization, Angiography, and Intervention. 4th ed. Philadelphia, PA, and London: Lea and Febiger; 1991. p. 52–165

37. Gorlin R. Calculations of cardiac valve stenosis: restoring an old concept for advanced applications. J Am Coll Cardiol. 1987;10:920–923[Medline]

38. Dumesnil JG, Yoganathan AP. Theoretical and practical differences between the Gorlin formula and the continuity equation for calculating aortic and mitral valve areas. Am J Cardiol. 1991;67:1268–1272[CrossRef][Medline]

39. Otto CM, Burwash IG, Legget ME, et al. Prospective study of asymptomatic valvular aortic stenosis. Circulation. 1997;95:2262–2270[Abstract/Free Full Text]

40. Cannon SR, Richards KL, Crawford M. Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula. Circulation. 1985;71:1170–1178[Abstract/Free Full Text]

41. Voelker W, Reul H, Nienhaus G, Stelzer T, et al. Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis. Circulation. 1995;91:1196–1204[Abstract/Free Full Text]

42. Segal J, Lerner DJ, Miller DC, Mitchell RS, Alderman EA, Popp RL. When should Doppler-determined valve area be better than the Gorlin formula? Variation in hydraulic constants in low flow states. J Am Coll Cardiol. 1987;9:1294–1305[Abstract]

43. Daboin NP, Frater RWN, Fisher LI, Nanna M, Strom JA. Non-invasive calculation of bio-prosthetic valve orifice area. Bodnar E. Surgery for Heart Valve Disease. Proceedings of the 1989 Symposium. 4th ed. London: ICR Publishers; 1990. p. 57–64

44. Grayburn PA, Eichhorn EJ, Eberhart RC, Bedotto JB, Brickner ME, Taylor AL. Aortic valve morphology influences regurgitant volume in aortic regurgitation: in vivo evaluation. Cardiovasc Res. 1991;25:73–79[Abstract/Free Full Text]

45. Vandervoort PM, Greenberg NL, Pu M, Powell KA, Cosgrove DM, Thomas JD. Pressure recovery in bileaflet heart valve prosthesis. Localized high velocities and gradients in central and side orifices with implication for Doppler-catheter gradient relation in aortic and mitral position. Circulation. 1995;92:3464–3472[Abstract/Free Full Text]

46. Niederberger J, Schima H, Maurer G, Baumgartner H. Importance of pressure recovery for the assessment of aortic stenosis by Doppler ultrasound. Circulation. 1996;94:1934–1940[Abstract/Free Full Text]

47. deFilippi CR, Willett DL, Brickner ME, et al. Usefulness of dobutamine echocardiography in distinguishing severe from nonsevere valvular aortic stenosis in patients with depressed left ventricular function and low transvalvular gradients. Am J Cardiol. 1995;75:191–194[CrossRef][Medline]

48. Schwammental E, Vered Z, Movsowitz Y, et al. Dobutamine echocardiography in patients with aortic stenosis and left ventricular dysfunction: predicting outcome as a function of management strategy. Chest. 2001;119:1766–1777[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
H. Baumgartner, J. Hung, J. Bermejo, J. B. Chambers, A. Evangelista, B. P. Griffin, B. Iung, C. M. Otto, P. A. Pellikka, and M. Quinones
Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
Eur J Echocardiogr, January 1, 2009; 10(1): 1 - 25.
[Full Text] [PDF]


Home page
Eur Heart JHome page
K. K. Poh, R. A. Levine, J. Solis, L. Shen, M. Flaherty, Y.-J. Kang, J. L. Guerrero, and J. Hung
Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography
Eur. Heart J., October 2, 2008; 29(20): 2526 - 2535.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. S. Kim, A. R. Hansgen, O. Wink, R. A. Quaife, and J. D. Carroll
Rapid Prototyping: A New Tool in Understanding and Treating Structural Heart Disease
Circulation, May 6, 2008; 117(18): 2388 - 2394.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. A. Flachskampf
Severe aortic stenosis with low gradient and apparently preserved left ventricular systolic function--under-recognized or overdiagnosed?
Eur. Heart J., April 2, 2008; 29(8): 966 - 968.
[Full Text] [PDF]


Home page
Eur Heart JHome page
J. Minners, M. Allgeier, C. Gohlke-Baerwolf, R.-P. Kienzle, F.-J. Neumann, and N. Jander
Inconsistencies of echocardiographic criteria for the grading of aortic valve stenosis
Eur. Heart J., April 2, 2008; 29(8): 1043 - 1048.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. Goland, A. Trento, K. Iida, L. S C Czer, M. De Robertis, T. Z Naqvi, K. Tolstrup, T. Akima, H. Luo, and R. J Siegel
Assessment of aortic stenosis by three-dimensional echocardiography: an accurate and novel approach
Heart, July 1, 2007; 93(7): 801 - 807.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. M. Lang, V. Mor-Avi, L. Sugeng, P. S. Nieman, and D. J. Sahn
Three-Dimensional Echocardiography: The Benefits of the Additional Dimension
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2053 - 2069.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. M. Ngan, I. M. Rebeyka, D. B. Ross, M. Hirji, J. F. Wolfaardt, R. Seelaus, A. Grosvenor, and M. L. Noga
The rapid prototyping of anatomic models in pulmonary atresia
J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 264 - 269.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. M. Otto
Valvular Aortic Stenosis: Disease Severity and Timing of Intervention
J. Am. Coll. Cardiol., June 6, 2006; 47(11): 2141 - 2151.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Baumgartner
Hemodynamic Assessment of Aortic Stenosis: Are There Still Lessons to Learn?
J. Am. Coll. Cardiol., January 3, 2006; 47(1): 138 - 140.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Baumgartner
Hemodynamic Assessment of Aortic Stenosis: Are There Still Lessons to Learn?
J. Am. Coll. Cardiol., December 13, 2005; (2005) j.jacc.2005.10.001v1.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. E. Weyman
The year in echocardiography
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 140 - 148.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. A. Levine and E. Schwammenthal
Stenosis is in the eye of the observer: impact of pressure recovery on assessing aortic valve area
J. Am. Coll. Cardiol., February 5, 2003; 41(3): 443 - 445.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gilon, D.
Right arrow Articles by Levine, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gilon, D.
Right arrow Articles by Levine, R. A.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement