LETTER TO THE EDITOR

Reliability of transfer functions in determining central pulse pressure and augmentation index

Sarah A. Hope, BSc (Hons)MBChB*, Ian T. Meredith, MBBS, PhD, FACC and James D. Cameron, MDMBBSBEMEngSc

* Cardiovascular Research Centre, Monash Medical Centre, 246 Clayton Road, Clayton, Victoria 3168, Australia

Sarah.Hope{at}med.monash.edu.au


We read with interest the study by Wilkinson et al. (1) in the March 20, 2002, issue of JACC. The investigators employed pulse wave analysis using sphygmorCor software (AtCor Medical, Sydney, Australia) for the derivation of central aortic waveforms from radial waveforms acquired by applanation tonometry, and they presented data on the derived aortic pulse pressure and augmentation index. The findings of the study are as expected; however, we are concerned that the technique described is being increasingly utilized, but remains poorly validated in the literature. The researchers state that the technique utilizes a "validated transfer function," yet this assertion is not supported by the references they quote (2–5).

Karamanoglu et al. (2) derived a transfer function by frequency domain analysis of central aortic and applanation tonometry-acquired radial waveforms in 14 patients. They report systolic pressure alone without prospective validation. Takazawa et al. (4) applied the transfer function of Karamanoglu et al. (2) to an additional small cohort and found an 11 mm Hg discrepancy between measured and derived central aortic pressures, when tonometry-acquired pressures were calibrated to noninvasive brachial pressures, suggesting that this transfer function may not be generalizable to other subjects. These investigators also found the transfer function to underestimate central augmentation index on average, with considerable individual variability that was not quantified.

Segers et al. (5) applied the transfer function of Chen et al. (6), derived by a time domain, rather than a frequency domain, analysis. There may be important differences between transfer functions derived by frequency and time domain analyses in their ability to reconstruct central waveforms accurately, with potential advantages to the latter (7). Segers et al. (5) found wide individual variability in derived aortic augmentation index, with Bland-Altman 95% limits of agreement of approximately 30%. These findings support those of Fetics et al. (7), using a different transfer function derived by time domain analysis, who described a percentage error in augmentation index estimation of 54 ± 232% in 19 patients, but very good estimation of central systolic pressure, when tonometry-acquired pressures were calibrated to central aortic mean and diastolic pressures. These findings are consistent with the findings of Chen et al. (6) that augmentation index is highly dependent upon high-frequency components of the waveform, and the frequency response characteristics of applanation tonometry are such that high-frequency data is inevitably lost by this technique (8). The proprietary transfer function of the sphygomoCor software is unpublished, and it is unclear as to whether it has been derived by either frequency or time domain analysis. Pauca et al. (3) utilized the sphygmoCor software and prospectively evaluated it for the derivation of central blood pressures only, from invasively measured radial waveforms, when calibration of peripheral waveforms was not required. These data cannot validate the technique for use with noninvasively obtained radial waveforms.

We suggest that, although some transfer functions may adequately reproduce central aortic pressures from radial waveforms acquired by applanation tonometry, it is premature to suggest that the technique is well validated for noninvasive use, and published data suggest that the technique may be unreliable for the derivation of central aortic augmentation index. This technique should be properly validated before being applied to large-scale prospective intervention studies.


    References
 Top
 References
 

  1. Wilkinson IB, Prasad K, Hall IR, et al. Increased central pulse pressure and augmentation index in subjects with hypercholesterolemia. J Am Coll Cardiol. 2002;39:1005–1011[Abstract/Free Full Text]
  2. Karamanoglu M, O’Rourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J. 1993;14:160–167[Abstract/Free Full Text]
  3. Pauca AL, O’Rourke MF, Kon ND. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension. 2001;38:932–937[Abstract/Free Full Text]
  4. Takazawa K, O’Rourke MF, Fujita M, et al. Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function. Z Kardiol. 1996;85:137–139
  5. Segers P, Qasem A, De Backer T, Carlier S, Verdonck P, Avolio A. Peripheral "oscillatory" compliance is associated with aortic augmentation index. Hypertension. 2001;37:1434–1439[Abstract/Free Full Text]
  6. Chen CH, Nevo E, Fetics B, et al. Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. Circulation. 1997;95:1827–1836[Abstract/Free Full Text]
  7. Fetics B, Nevo E, Chen CH, Kass DA. Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry. IEEE Trans Biomed Eng. 1999;46:698–706[CrossRef][Medline]
  8. Sato T, Nishinaga M, Kawamoto A, Ozawa T, Takatsuji H. Accuracy of a continuous blood pressure monitor based on arterial tonometry. Hypertension. 1993;21:866–874[Abstract/Free Full Text]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hope, S. A.
Right arrow Articles by Cameron, J. D.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Hope, S. A.
Right arrow Articles by Cameron, J. D.

 
  cardiology careers collections past issues search home