Advertisement





Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2002; 40:1882-1888
© 2002 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stone, G. W.
Right arrow Articles by Bailey, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stone, G. W.
Right arrow Articles by Bailey, S.

EXPEDITED REVIEW

Distal filter protection during saphenous vein graft stenting

Technical and clinical correlates of efficacy

Gregg W. Stone, MD, FACC*,*,1, Campbell Rogers, MD, FACC{dagger},1, Steve Ramee, MD, FACC{ddagger}, Christopher White, MD, FACC{ddagger}, Richard E. Kuntz, MD, FACC{dagger}, Jeffrey J. Popma, MD, FACC{dagger}, John George, MD, FACC§, Steve Almany, MD, FACC|| and Steve Bailey, MD, FACC

* The Cardiovascular Research Foundation and Lenox Hill Hospital, New York, New York, USA
{dagger} Brigham & Women’s Hospital, Boston, Massachusetts, USA
{ddagger} Ochsner Clinic, New Orleans, Louisiana, USA
§ Western Pennsylvania Hospital, Pittsburgh, Pennsylvania, USA
|| William Beaumont Hospital, Royal Oak, Michigan, USA
University of Texas San Antonio, San Antonio, Texas, USA

Manuscript received August 25, 2002; revised manuscript received September 2, 2002, accepted September 10, 2002.

* Reprint requests and correspondence: Dr. Gregg W. Stone, The Cardiovascular Research Foundation, 55 E. 59th Street, 6th Floor, New York, New York 10022, USA.
gstone{at}crf.org


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 APPENDIX
 References
 
OBJECTIVES: The aim of this study was to evaluate the clinical, angiographic, and technical factors related to successful stenting of diseased saphenous vein grafts (SVGs) using a novel filter-based distal protection device.

BACKGROUND: Protection of the distal microvasculature with a balloon occlusion and aspiration system has been shown to reduce atherothrombotic embolization and peri-procedural myocardial infarction (MI) after percutaneous coronary intervention (PCI) in SVGs. The safety, efficacy, and technical factors relating to procedural success with filter-based distal protection devices are unknown.

METHODS: Percutaneous coronary intervention was performed in 60 lesions in 48 patients undergoing SVG intervention with the FilterWire EX distal protection system in a phase I experience at six sites. A larger phase II study was then performed in 248 lesions in 230 SVGs at 65 U.S. centers.

RESULTS: Cumulative adverse events to 30 days occurred in 21.3% of patients in phase I, including a 19.1% rate of MI. Numerous anatomic, device-specific, and operator-related contributors to these adverse events were identified, resulting in significant changes to the protocol and instructions for use. Subsequently, despite similar clinical and angiographic characteristics to the phase I patients, the 30-day adverse event rate in phase II was reduced to 11.3% (p = 0.09), due primarily to a lower incidence of peri-procedural Q-wave and non–Q-wave MI.

CONCLUSIONS: Distal protection during SVG PCI with the FilterWire EX is associated with a low rate of peri-procedural adverse events compared to historical controls. A unique set of anatomic, technical, and operator-related issues exist with distal filters which, if ignored, may reduce their effectiveness.

Abbreviations and Acronyms
  GP
  glycoprotein
  LVEF
  left ventricular ejection fraction
  MACE
  major adverse cardiac events
  MI
  myocardial infarction
  PCI
  percutaneous coronary intervention
  SVG
  saphenous vein graft
  TIMI
  Thrombolysis In Myocardial Infarction
  TLR
  target lesion revascularization


Embolization of atherothrombotic debris after percutaneous coronary intervention (PCI) in diseased saphenous vein grafts (SVGs) results in peri-procedural myocardial infarction (MI) in as many as one-third of patients (1–4). Of numerous investigated approaches (5–11), only protection of the distal microcirculation by a balloon occlusion and aspiration system (the PercuSurge GuardWire) has been clearly demonstrated to enhance the safety of contemporary SVG intervention (12).

Catheter-based filters as an adjunct to SVG intervention have recently entered clinical investigation (13–15). Characterized by their relative ease of use and maintenance of perfusion, distal filters may at first seem inherently preferable to balloon occlusion and aspiration systems. However, the safety and efficacy of distal filters have not yet been demonstrated. Therefore, we performed two consecutive prospective, multicenter registries with a new distal protection device, the FilterWire EX (Embolic Protection Inc., Boston Scientific Corp., Natick, Massachusetts), to examine its effectiveness during PCI of SVGs, and to uncover technical and device related factors impacting procedural success.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 APPENDIX
 References
 
Before initiation of the pivotal U.S. randomized trial for device approval, the FilterWire EX was evaluated in a phase I study at six sites. After review of the phase I 30-day data, the multicenter pivotal phase II study commenced with a lead-in stage at 65 centers enrolling up to five patients per site. Both studies were performed under a Food and Drug Administration (FDA) investigational device exemption. The studies were approved by the investigational review board at each participating institution, and all patients signed written, informed consent before study entry.

Study device.   The FilterWire EX consists of a distal polyurethane filter with 80 to 110 µm diameter pores mounted on a 0.014-inch steerable guidewire via a "spinner tube" which permits independent 360° wire rotation and steering (Fig. 1). The filter is attached to a self-expandable radiopaque nitinol loop which is elliptical in shape, affording maximal surface area for particle capture and compatibility with vessels 3.5 to 5.5 mm in diameter with the same device. The collapsed filter (3.9F crossing profile) is passed distal to the lesion and deployed by retracting the delivery sheath. The filter is then closed with the delivery/retrieval sheath after PCI and withdrawn.



View larger version (114K):
[in this window]
[in a new window]
 
Figure 1 The FilterWire EX, consisting of a 0.014-inch steerable guidewire on which a freely rotating distal polyurethane filter is mounted, shown in its deployed configuration (top and middle) and retracted position (bottom) after being withdrawn into the delivery/retrieval sheath (white arrow). A distal nosecone (black arrow) prevents passage of the sheath beyond the wire tip

 
Phase I study—Patient entry criteria.   Consecutive patients with ≥1 eligible SVG lesions meeting the following inclusion criteria were enrolled: age ≥21 years; lesion length <40 mm, reference vessel diameter 3.5 to 5.5 mm, diameter stenosis <100% and Thrombolysis In Myocardial Infarction (TIMI) flow grade ≥2; and presence of ≥2 cm of straight segment in the SVG distal to the lesion. Major exclusion criteria included: MI within 24 h or CK-MB >2x normal; contrast or study medication contraindication; treatment required in non-qualifying vessels; left ventricular ejection fraction <30%; and planned treatment with atherectomy, thrombectomy, laser or other distal protection devices.

Phase I study—Study procedures.   All patients received aspirin before the procedure and indefinitely thereafter. Clopidogrel (or ticlopidine) was recommended before the procedure and continued for 30 days after stent placement. An activated clotting time of >300 s was achieved before PCI, or 200 to 300 s if glycoprotein (GP) IIb/IIIa inhibitors were administered (per investigator discretion). Percutaneous coronary intervention was then performed with FilterWire distal protection. CK-MB levels were measured at baseline and every 8 h x3 post procedure. Clinical follow-up occurred at 30 days.

Phase I failure analysis.   Given a higher than expected adverse event rate in phase I, a detailed failure analysis was performed, including procedural technique and angiographic review. As described in the Results, four correctable technical errors were identified that appeared causally related to major adverse cardiac events (MACE). These technical issues were addressed in the phase II protocol and received repeated emphasis at a series of investigator meetings and study conferences.

Phase II study protocol and procedures.   Compared with phase I, the phase II entry criteria allowed inclusion of more complex lesions, including vessels with TIMI-1 flow, and lesions of any length. Otherwise the phase I and II enrollment criteria were similar. The phase II protocol incorporated five important changes in technique and operator instructions: 1) a ≥2.5-cm gap before the distal anastomosis was required for placement of the filter apparatus distal to the lesion; 2) the FilterWire loop was required to be placed in the mid portion of a ≥2-cm straight section of the SVG to avoid deformation of the device (Fig. 2); 3) orthogonal views were mandated to document appropriate filter apposition before dilation; 4) specific instructions were provided not to retract the entire debris-laden filter into the sheath; and 5) the importance of established distal protection during all SVG dilations was emphasized.



View larger version (23K):
[in this window]
[in a new window]
 
Figure 2 Diagrammatic representation of the FilterWire across a vein graft lesion, with the minimal distances pre-specified in the phase II protocol for optimal performance.

 
End points and definitions.   Study end points and definitions were identical for both registries. The primary end point was the incidence of MACE at 30 days, defined as death, MI, or target lesion revascularization. Myocardial infarction was defined as any postprocedural CK-MB >3x normal.

Data collection, quality assurance, and statistical analysis.   Data were independently monitored on-site for accuracy, and double-key entered into a computerized database by an independent research organization. An independent Clinical Events Committee adjudicated all adverse outcomes. Quality control measures included use of independent angiographic and electrocardiographic core laboratories. These processes and the organizations employed were identical for both studies.

Categorical variables were compared by chi-squared analysis or Fisher exact test. Continuous variables are presented as mean ± standard deviation and were compared by unpaired Student t test. All p values are two-tailed. Significance was determined at the p = 0.05 level. The independent determinants of 30-day MACE in the phase II cohort were determined by entering all variables predictive of adverse outcomes by univariate analysis with a p value <0.10 into a multivariate logistic regression model.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 APPENDIX
 References
 
Phase I and phase II patient populations.   Between October 2000 and April 2001, 48 consecutive patients underwent intervention of 60 SVG lesions with FilterWire distal protection in the phase I study. Subsequently, between May 2001 and April 2002, 230 consecutive patients underwent intervention of 248 SVG lesions with FilterWire distal protection during the roll-in period of the phase II study. The baseline demographic and lesion characteristics of the two study cohorts were similar, except hypertension was more common in phase I, patients in phase II were more likely to be active smokers, and left ventricular function was slightly better in phase II (Table 1).


View this table:
[in this window]
[in a new window]
 
Table 1 Baseline Clinical and Angiographic Characteristics of Patients Enrolled in the Phase I and Phase II Registry Studies

 
Results of phase I.   The FilterWire was successfully delivered and deployed in 95.7% of cases. Postprocedural TIMI-3 flow was present in 94.7% of grafts, TIMI-2 flow in 3.5%, and TIMI-0/1 flow in 1.8%. In-hospital MACE occurred in 18.8% of patients prior to hospital discharge, and in 21.3% of patients by 30 days. As shown in Table 2, most events consisted of peri-procedural MI.


View this table:
[in this window]
[in a new window]
 
Table 2 30-Day Adverse Cardiac Events in 48 Patients Undergoing SVG Intervention of 60 Lesions With FilterWire Distal Protection in the Phase I Registry

 
Failure analysis.   Detailed procedural and angiographic analysis of the 10 cases in which MACE occurred revealed the following possible causative factors (several of which were present in some patients): wire bias or geometric factors resulting in filter loop malapposition (Fig. 3), n = 3; excessively distal lesion location such that the filter could not open properly or was placed in a native coronary vessel, leaving proximal branches unprotected (Fig. 4), n = 4; balloon dilations and/or stent implantations performed without distal protection (excluding pre-dilation), n = 4; SVG diameter 7 mm with resultant filter malapposition, n = 1; filter placed in a single distal limb of a bifurcating Y graft, such that the other limb was unprotected, n = 1; and heavily loaded filter completely retracted into the delivery sheath, resulting in atheromatous extrusion and embolization, n = 1.



View larger version (78K):
[in this window]
[in a new window]
 
Figure 3 Potential failure mode—lack of filter apposition against the vessel wall. (A) Post-stenting of the mid shaft of the saphenous vein graft to the right coronary artery (black arrow) with the FilterWire in place (white arrow). (B) Magnification of panel A—the nitinol loop of the FilterWire may be seen. (C) Further magnification and enhancement of the FilterWire, showing that the nitinol loop (black arrow) and collection filter (cross hatched net) are clearly lifted off the inferior wall of the vein graft, likely due to geometric wire bias resulting from placement of the distal wire tip in the posterolateral branch (white arrow). Relocating the guidewire tip into the more inferior posterior descending artery may have apposed the filter loop against the vein graft wall.

 


View larger version (103K):
[in this window]
[in a new window]
 
Figure 4 Potential failure mode—excessively distal lesion resulting in incomplete filter opening or unprotected native side branches. (A) Ulcerated lesion (arrow) in the distal shaft of the saphenous vein graft to the obtuse marginal branch of the left circumflex artery. (B) FilterWire deployed, with the distal nitinol loop protruding into the upper branch of the bifurcating obtuse marginal (arrow). (C) As a result, the polyurethane collection filter (arrow and cross hatched net) cannot open fully and is compressed in the undersized branch (<3.0 cm), impairing particulate recovery both in the partially protected superior branch and unprotected inferior branch.

 
Results of phase II.   The FilterWire was successfully delivered and deployed in 96.5% of cases. Stent use, implantation parameters, and procedural outcomes were similar to phase I, except that GP IIb/IIIa inhibitors were used more frequently (Table 3). Angiographic complications, as determined by the core laboratory, were less frequent in phase II compared with phase I, with fewer episodes of no reflow and distal thromboemboli noted. Moreover, 30-day cumulative MACE occurred in fewer patients in phase II than in phase I, predominantly because of a lower rate of peri-procedural MI (Fig. 5). From 18 baseline variables, the only univariate correlates of 30-day MACE in patients undergoing SVG intervention with FilterWire distal protection were longer lesion length, greater diameter stenosis, and the presence of thrombus (Table 4); by multivariate analysis, only long lesion length was independently predictive of MACE (odds ratio = 3.69, p = 0.015).


View this table:
[in this window]
[in a new window]
 
Table 3 Procedural Results, Comparing Patients Enrolled in Phase I and Phase II

 


View larger version (17K):
[in this window]
[in a new window]
 
Figure 5 Cumulative 30-day major adverse cardiac event (MACE) rates in 48 patients in the phase I study compared to 230 patients in the phase II study. MI = myocardial infarction; TLR = target lesion revascularization.

 

View this table:
[in this window]
[in a new window]
 
Table 4 Variables Correlating With MACE Within 30 Days

 

    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 APPENDIX
 References
 
The present report details a large multicenter experience with FilterWire distal protection as an adjunct to PCI in 308 lesions in 278 SVGs. Use of this device resulted in 30-day rates of MACE below that expected from historical controls. Moreover, during the course of this sequential two-phase investigation, a unique set of anatomic, technical, and operator-related issues were uncovered which, if ignored, may reduce the effectiveness of the FilterWire.

Phase I results and failure analysis.   A disturbingly high 21.3% 30-day event rate occurred in the first 60 lesions in 48 SVGs, similar to that expected from historical controls. A detailed failure analysis revealed several correctable conditions that may have contributed to adverse events. Several of these issues were intuitive (performance of dilation without protection in place), whereas others were clearly operator- or device-specific.

First, several cases of distal embolization were temporally related to balloon dilation without the protection device in place. Typically the device had been removed after an apparently successful result, following which residual disease or dissection were noted requiring further intervention, which was performed without protection either because of difficulty in recrossing the treated zone or perceived low embolic potential. These cases reinforce the difficulty in predicting embolic risk during SVG intervention and emphasize the need for distal protection during all phases of the procedure. Similarly, placing the filter distal to a side-to-side Y-graft anastomosis will clearly allow emboli in the unprotected proximal branch.

A second and unexpected correlate of peri-procedural MI was the lack of optimal filter apposition against the SVG wall. Because even a freshly placed filter offers a modest flow barrier, blood perfusate containing embolic particles will take the path of least resistance, selectively shunting debris around the filter when possible. The most common cause of lack of filter apposition was lifting of the nitinol wire frame off the vessel wall due to wire bias from anatomic and geometric factors. Notably, this condition may be hidden when the filter is viewed en face, only to be revealed by observing the filter loop on edge in an orthogonal projection. This condition may at times be corrected by moving the filter apparatus to a straighter portion of the vessel, or redirecting the distal guidewire into another branch (Fig. 3). Moreover, as the unrestrained diameter of the nitinol loop is ~6 mm, positioning the distal apparatus in an oversized segment will by definition also result in malapposition.

A third cause of MACE was overestimation of the distance from the lesion to the distal anastomosis, resulting in the collection net being released in a native arterial branch, with either subsequent narrowing of the collection aperture or lack of protection of secondary branches.

Phase II results.   As a response to this analysis, the phase II protocol and Instructions for Use were modified, and an intense education campaign was initiated for all sites, consisting of investigator meetings, written communications, and teleconferences. Orthogonal views were mandated to detect filter loop malapposition; the distance required from the lesion to the distal anastomosis was increased; a straight section for the distal apparatus was required; instructions were given to retract the filter into the retrieval sheath just enough to close the nitinol loop; and the importance of established distal protection during all phases of the intervention was emphasized. In the large phase II experience consisting of SVG intervention in 248 lesions in 230 vessels at 65 sites, the MACE rate was reduced to 11.3%, approximately 50% lower than in phase I (despite nearly identical patient and vein graft characteristics), due largely to reductions in Q-wave and non–Q-wave MI. These improved results are especially notable given the greater number of sites with less experience in phase II, representing a real-world example of how early lessons learned may be effectively communicated to future operators.

An additional observation that deserves mention pertains to GP IIb/IIIa inhibitor use, which by operator choice was more common in phase II than phase I. Although GP IIb/IIIa inhibitors have not been found to be beneficial as an adjunct to PCI in SVGs (6), it is conceivable that by reducing platelet-fibrin deposition on the filter surface, GP IIb/IIIa inhibitors might diminish the slow flow state that can occur when filters become overloaded, a phenomenon which has been related to MACE.

Other causes of MACE and device enhancements.   Despite the improved outcomes in phase II, the fact that 10% of patients still developed peri-procedural MI in phase II suggests that other device- and operator-related variables may still result in MACE and highlights the need for future device enhancements. The MACE rates were increased approximately three-fold with long lesions, high-grade baseline stenoses, and in the presence of thrombus, emphasizing that particular care is warranted when intervening in SVGs with these characteristics, even with filter-based distal protection. Macroscopic or angiographically unapparent distal thromboemboli may be induced by guidewire or device crossing of high-grade friable lesions, suggesting that outcomes might be improved by more steerable, flexible, and lower profile catheters. Debris collection may be incomplete as smaller particles may pass through the filter pores, and an excessively burdened filter may pose challenges for loop closure and debris retrieval without material extrusion. Future FilterWire iterations will incorporate a self-centering mechanism to reduce the impact of geometric influences and a crossing profile below 3F.

Comparison with alternative methods for distal protection.   The results of this investigation apply only to the FilterWire EX; other distal protection filter systems may have unique advantages or disadvantages which might result in a very different safety or efficacy profile. Similarly, the results of this study should not be used to support meaningful comparisons between the investigational FilterWire and balloon occlusion and aspiration with the FDA-approved PercuSurge GuardWire. However, on the basis of these phase II outcomes, a non-inferiority trial has been initiated in which 650 patients undergoing PCI in SVGs were randomized to distal protection with the FilterWire versus the GuardWire; the results of this study are expected in late 2002.

Clinical implications.   The FilterWire, while currently investigational in the U.S., is widely used in many parts of the world, and thus the results of this investigation have immediate clinical implications for the operators using this device. Recognition of the unique set of anatomic, technical, and operator-related issues that exist with the FilterWire (and indeed with all distal protection devices), as described herein, may further improve the outcomes for high-risk patients undergoing PCI in degenerated SVGs with distal protection.


    APPENDIX
 Top
 Abstract
 Methods
 Results
 Discussion
 APPENDIX
 References
 
Phase I study organization: Principal investigator (PI): Gregg W. Stone. Clinical sites and local PIs: Lenox Hill Hospital, New York, NY, Gregg W. Stone (PI); Ochsner Clinic, New Orleans, LA, Steve Ramee (PI), Chris White; Brigham & Women’s Hospital, Boston, MA, Campbell Rogers (PI); William Beaumont Hospital, Royal Oak, MI, Steve Almany (PI); Western Pennsylvania Hospital, Pittsburgh, PA, John George (PI); University of Texas San Antonio, San Antonio, TX, Steve Bailey (PI).

Phase II study organization:Executive Committee: Gregg W. Stone (PI), Campbell Rogers (Co-PI), Steve Ramee, Richard E. Kuntz, Milton McColl. Clinical sites and local PIs: Kaiser Permanente, Los Angeles, CA, Vicken Aharonian (PI); Palmetto Richland Memorial Hospital, Columbia, SC, Milton Alexander (PI); Beaumont Hospital, Royal Oak, MI, Steven L. Almany (PI); University Hospital, San Antonio, TX, Steven Bailey (PI); Laval Hospital, Quebec, Canada, Gerald Barbeau (PI); St. Joseph Mercy Hospital, Ann Arbor, MI, Jim Bengtson (PI); Moses Cone Hospital, Greensboro, NC, Bruce Brodie (PI); Scripps Memorial Hospital, La Jolla, CA, Maurice Buchbinder (PI); Morton Plant Mease, Clearwater, FL, Patrick A. Cambier (PI); St. Joseph’s Hospital Health, Syracuse, NY, Ron Caputo (PI); Deborah Heart and Lung, Browns Mills, NJ, Se Do Cha (PI); Sacred Heart Medical Center, Eugene, OR, Joseph W. Chambers (PI); Medical College of Ohio, Toledo, OH, Christopher Cooper (PI); Presbyterian Healthcare, Charlotte, NC, Dave Cox (PI); Sarasota Memorial Hospital, Sarasota, FL, Stephen C. Culp (PI); University of Washington, Seattle, WA, Larry S. Dean (PI); Albany Medical Center, Albany, NY, Augustin DeLago (PI); Arizona Heart Institute, Phoenix, AZ, Walid Alami (PI), Nabil Dib (PI); Munroe Regional Medical, Ocala, FL, Robert Feldman (PI); Western Baptist Hospital, Paducah, KY, J. Kenneth Ford (PI); Beth Israel Medical Center, New York, NY, John Fox (PI); St. Thomas Hospital, Nashville, TN, Joseph L. Fredi & P. Robert Myers (PI); Mount Sinai Medical Center, Miami Beach, FL, Francesca Gallarello (PI); St. Mary’s Hospital, Rochester, MN, Kirk N. Garratt (PI); Western Pennsylvania Hospital, Pittsburgh, PA, John George (PI); Carolinas Healthcare, Charlotte, NC, Robert H. Haber (PI); Providence Hospital, Columbia, SC, Patrick A. X. Hall (PI); Vancouver Hospital, Vancouver, BC, Canada, Jaap Hamburger (PI); St. Vincent Hospital, Indianapolis, IN, James B. Hermiller (PI); Presbyterian Healthcare, Philadelphia, PA, Howard Herrmann (PI); St. Luke’s Medical Center, Phoenix, AZ, Richard R. Heuser (PI); New York Presbyterian, New York, NY, Mun K. Hong (PI); VA Puget Sound Health Care, Seattle, WA, Samir Kapadia (PI); VA Palo Alto, Palo Alto, CA, Aaron Kaplan (PI); Long Island Jewish Hospital, New Hyde Park, NY, Barry Kaplan (PI); North Shore University Hospital at Manhasset, Manhasset, NY, Stanley Katz (PI); Maine Medical Center, Portland, ME, Mirle A. Kellett (PI); The Christ Hospital, Cincinnati, OH, Dean J. Kereiakes (PI); University of Oklahoma Hospital, Oklahoma City, OK, George Khammar (PI); Eisenhower Medical Center, Rancho Mirage, CA, Puneet K. Khanna (PI); Mount Sinai Hospital, Chicago, IL, Sandeep Khosla (PI); St. Joseph’s Hospital of Atlanta, Atlanta, GA, William Knopf (PI); Duke University Medical Center, Durham, NC, David F. Kong (PI); Our Lady of Lourdes Medical Center, Camden, NJ, Richard Kovach (PI); Henry Ford Hospital, Detroit, MI, Aaron Kugelmass (PI); University of Ottawa Heart, Ottawa, Ontario, Canada, Marino Labinaz (PI); Barnes Jewish Hospital, St. Louis, MO, John LaSala (PI); VAMC/Baylor College of Medicine, Houston, TX, Glenn N. Levine (PI); The Dayton Heart Hospital, Dayton, OH, Sudhakar Maraboyina (PI); Buffalo General Hospital, Buffalo, NY, A. R. Zaki Masud (PI); Good Samaritan Hospital, Los Angeles, CA, Ray Matthews (PI); Hahnemann University, Philadelphia, PA, Daniel McCormick (PI); Greenville Memorial Hospital/St. Francis Hospital, Greenville, SC, Brent McLaurin (PI); St. Joseph’s Hospital, Marshfield, WI, Juan Mesa (PI); St. John’s Hospital/Memorial Medical Center, Springfield, IL, Gregory Mishkel (PI); St. Luke’s Episcopal Hospital, Houston, TX, Ali Mortazavi (PI); Arkansas Heart Hospital, Little Rock, AR, Bruce E. Murphy (PI); Fountain Valley Regional Hospital, Fountain Valley, CA, Subbarao Myla (PI); Hoag Memorial Hospital, Newport Beach, CA, Subbarao Myla (PI); Christiana Care, Newark, DE, James Ritter (PI); Sacramento Heart/Sutter Medical Center, Sacramento, CA, David K. Roberts (PI); Brigham and Women’s Hospital, Boston, MA, Campbell Rogers (PI); Phoenix Memorial Hospital, Phoenix, AZ, Robert M. Siegel (PI); University of Arizona/Sarver Heart Center, Tucson, AZ, Marvin J. Slepian (PI); Lenox Hill Hospital, New York, NY, Gregg Stone (PI); The Valley Hospital, Ridgewood, NJ, Janet Strain (PI); Mercy Medical Center, Des Moines, IA, Mark Tannenbaum (PI); Queen Elizabeth Health Sciences Centre, Halifax, NS, Canada, Robert Teskey and Hussein Beydoun (PI); Washington Adventist Hospital, Takoma Park, MD, Mark A. Turco (PI); St. Paul’s Hospital, Vancouver, BC, Canada, John Webb (PI); Ochsner Foundation Clinic, New Orleans, LA, Chris White (PI); St. Luke’s Roosevelt Hospital, New York, NY, James Wilentz (PI); Spectrum Health, Grand Rapids, MI, Kevin Wolschleger (PI); Stanford Hospital, Stanford, CA, Alan Yeung (PI).

Common phase I and II study organization: Data Management, Clinical Events Adjudication, and Biostatistical Analysis: Harvard Clinical Research Institute, Cardiovascular Data Analysis Center, Boston, MA, Richard E. Kuntz (Director). Data Monitoring: Boston Scientific Corp, Natick, MA. Core Angiographic Laboratory: Brigham and Women’s Hospital Core Angiographic Laboratory, Boston, MA, Jeffrey J. Popma (Director). Electrocardiographic Core Laboratory: Cardiovascular Data Analysis Center, Boston, MA, Peter Zimetbaum (Director).


    Footnotes
 
Supported by Embolic Protection Inc., Boston Scientific Corp., Natick, Massachusetts.

1 Dr. Stone has served as a consultant for Boston Scientific, Medtronic/PercuSurge and Guidant, manufacturers of competing distal protection devices; Dr. Rogers has served on speakers bureaus for the same three companies. Back


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 APPENDIX
 References
 
1. de Feyter PJ, van Suylen R-J, deJaegere PPT, Topol EJ, Serruys PW. Balloon angioplasty for the treatment of lesions in saphenous vein bypass grafts. J Am Coll Cardiol. 1993;21:1539–1540[Abstract]

2. Holmes DR, Topol EJ, Califf RM, et al. A multicenter, randomized trial of coronary angioplasty versus directional atherectomy for patients with saphenous vein bypass graft lesions. Circulation. 1995;91:1966–1974[Abstract/Free Full Text]

3. Hong MK, Mehran R, Dangas G, et al. Creatine kinase-MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality. Circulation. 1999;100:2400–2405[Abstract/Free Full Text]

4. Hong MK, Mehran R, Dangas G, Mintz GS, et al. Are we making progress with percutaneous saphenous vein graft treatment? A comparison of 1990 to 1994 and 1995 to 1998 results. J Am Coll Cardiol. 2001;38:150–154[Abstract/Free Full Text]

5. Lefkovits J, Holmes DR, Califf RM, et al. Predictors and sequelae of distal embolization during saphenous vein graft intervention from the CAVEAT-II Trial. Circulation. 1995;92:734–740[Abstract/Free Full Text]

6. Ellis SG, Lincoff AM, Miller D, et al. Reduction in complications of angioplasty with abciximab occurs largely independently of baseline lesion morphology. J Am Coll Cardiol. 1998;32:1619–1623[Abstract/Free Full Text]

7. Safian RD, Grines CL, May MA, et al. Clinical and angiographic results of transluminal extraction coronary atherectomy in saphenous vein bypass grafts. Circulation. 1994;89:302–312[Abstract/Free Full Text]

8. Hamburger J, Serruys PW. Treatment of thrombus containing lesions in diseased native coronary arteries and saphenous vein bypass grafts using the AngioJet Rapid Thrombectomy System. Herz. 1997;22:318–321[Medline]

9. Teirstein PS, Mann JT, Cundey PE, et al. Low- versus high-dose recombinant urokinase for the treatment of chronic saphenous vein graft occlusion. Am J Cardiol. 1999;3:1623–1628

10. Cohen DJ, Ramee S, Baim DS, et al. Economic assessment of rheolytic thrombectomy versus intracoronary urokinase for treatment of extensive intracoronary thrombus: results from a randomized clinical trial. Am Heart J. 2001;142:648–656[Medline]

11. Bittl JA, Sanborn TA, Yardley DE, et al. Predictors of outcome of percutaneous excimer laser coronary angioplasty of saphenous vein bypass graft lesions. Am J Cardiol. 1994;74:144–148[CrossRef][Medline]

12. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts. Circulation. 2002;105:13–18[CrossRef]

13. Grube E, Gerckens U, Yeung AC, et al. Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection. Circulation. 2001;104:2436–2441[Abstract/Free Full Text]

14. Al-Mubarak N, Colombo A, Gaines PA, et al. Multicenter evaluation of carotid artery stenting with a filter protection system. J Am Coll Cardiol. 2002;39:841–846[Abstract/Free Full Text]

15. Reimers B, Corvaja N, Moshiri S, et al. Cerebral protection with filter devices during carotid artery stenting. Circulation. 2001;104:12–15[Abstract/Free Full Text]




This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
D. J. Kereiakes, M. A. Turco, J. Breall, N. Z. Farhat, R. L. Feldman, B. McLaurin, J. J. Popma, L. Mauri, P. Zimetbaum, J. Massaro, et al.
A Novel Filter-Based Distal Embolic Protection Device for Percutaneous Intervention of Saphenous Vein Graft Lesions: Results of the AMEthyst Randomized Controlled Trial
J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 248 - 257.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol IntvHome page
A. J. Kirtane, E. R. Heyman, C. Metzger, J. A. Breall, and J. P. Carrozza Jr
Correlates of Adverse Events During Saphenous Vein Graft Intervention With Distal Embolic Protection: A PRIDE Substudy
J. Am. Coll. Cardiol. Intv., April 1, 2008; 1(2): 186 - 191.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. Mauri, D. Cox, J. Hermiller, J. Massaro, J. Wahr, S. W. Tay, M. Jonas, J. J. Popma, J. Pavliska, D. Wahr, et al.
The PROXIMAL Trial: Proximal Protection During Saphenous Vein Graft Intervention Using the Proxis Embolic Protection System: A Randomized, Prospective, Multicenter Clinical Trial
J. Am. Coll. Cardiol., October 9, 2007; 50(15): 1442 - 1449.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. Jonas, G. W. Stone, R. Mehran, J. Hermiller, R. Feldman, H. C. Herrmann, D. A. Cox, R. E. Kuntz, J. J. Popma, C. Rogers, et al.
Platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment during saphenous vein graft stenting: differential effects after randomization to occlusion or filter-based embolic protection
Eur. Heart J., April 2, 2006; 27(8): 920 - 928.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Herrmann
Peri-procedural myocardial injury: 2005 update
Eur. Heart J., December 1, 2005; 26(23): 2493 - 2519.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. A. Gorog, R. A. Foale, and I. Malik
Distal Myocardial Protection During Percutaneous Coronary Intervention: When and Where?
J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1434 - 1445.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
G Sangiorgi and A Colombo
Embolic protection devices
Heart, September 1, 2003; 89(9): 990 - 992.
[Full Text] [PDF]


Home page
CirculationHome page
G. W. Stone, C. Rogers, J. Hermiller, R. Feldman, P. Hall, R. Haber, A. Masud, P. Cambier, R. P. Caputo, M. Turco, et al.
Randomized Comparison of Distal Protection With a Filter-Based Catheter and a Balloon Occlusion and Aspiration System During Percutaneous Intervention of Diseased Saphenous Vein Aorto-Coronary Bypass Grafts
Circulation, August 5, 2003; 108(5): 548 - 553.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stone, G. W.
Right arrow Articles by Bailey, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stone, G. W.
Right arrow Articles by Bailey, S.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement