Advertisement





Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2002; 39:2059-2068
© 2002 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ioannidis, J. P. A.
Right arrow Articles by Danias, P. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ioannidis, J. P. A.
Right arrow Articles by Danias, P. G.

CLINICAL STUDY

Electrocardiogram-gated single-photonemission computed tomography versus cardiacmagnetic resonance imaging for the assessmentof left ventricular volumes and ejection fraction

A meta-analysis

John P. A. Ioannidis, MD*{dagger}, Thomas A. Trikalinos* and Peter G. Danias, MD, PhD, FACC{ddagger},*

* Clinical Trials and Evidence-Based Medicine Unit and Clinical and Molecular Epidemiology Unit, Department of Hygiene and Epidemiology, University of Ioannina School of Medicine, Ioannina, Greece
{dagger} Department of Medicine, Tufts University School of Medicine, Boston, Massachusetts, USA
{ddagger} Cardiology Division, Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA

Manuscript received September 18, 2001; revised manuscript received February 25, 2002, accepted March 14, 2002.

* Reprint requests and correspondence: Dr. Peter G. Danias, Division of Cardiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, Massachusetts 02215, USA.
pdanias{at}caregroup.harvard.edu


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES: The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI).

BACKGROUND: Several comparisons of ECG-gated SPECT with cardiac MRI have been performed for evaluation of LV volumes and EF, but each has considered few subjects, thus leaving uncertainty about the frequency of discrepancies between the two methods.

METHODS: We performed a meta-analysis of data on 164 subjects from nine studies comparing ECG-gated SPECT versus cardiac MRI. Data were pooled in correlation and regression analyses relating ECG-gated SPECT and cardiac MRI measurements. The frequency of discrepancies of at least 30 ml in EDV, 20 ml in ESV and 5% or 10% in EF and concordance for EF ≤40% versus >40% were determined.

RESULTS: There was an overall excellent correlation between ECG-gated SPECT and cardiac MRI for EDV (r = 0.89), ESV (r = 0.92) and EF (r = 0.87). However, rates of discrepancies for individual subjects were considerable (37% [95% confidence interval {CI}, 26% to 50%] for at least 30 ml in EDV; 35% [95% CI, 23% to 49%] for at least 20 ml in ESV; 52% [95% CI, 37% to 63%] for at least 5% in EF; and 23% [95% CI, 11% to 42%] for at least 10% in EF). The misclassification rate for the 40% EF cutoff was 11%.

CONCLUSIONS: Electrocardiogram-gated SPECT measurements of EDV, ESV and EF show high correlation with cardiac MRI measurements, but substantial errors may occur in individual patients. Electrocardiogram-gated SPECT offers useful functional information, but cardiac MRI should be used when accurate measurement is required.

Abbreviations and Acronyms
  CAD
  coronary artery disease
  CI
  confidence interval
  ECG
  electrocardiogram
  EDV
  end-diastolic volume
  EF
  ejection fraction
  ESV
  end-systolic volume
  LV
  left ventricle/ventricular
  MRI
  magnetic resonance imaging
  SEE
  standard error of estimate
  SPECT
  single-photon emission computed tomography


Electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT), primarily using technetium-99m, is advocated as an imaging technique that can offer valuable information in the assessment of both myocardial perfusion and ventricular function. While the value of ECG-gated SPECT in assessing myocardial perfusion is undisputed (1,2), there are fewer data on the accuracy of ECG-gated SPECT for estimating left ventricular (LV) volumes and ejection fraction (EF). Cardiac magnetic resonance imaging (MRI) is currently considered the gold standard for these evaluations (3,4). Although studies evaluating the performance of ECG-gated SPECT versus cardiac MRI have suggested a good concordance of the two methods (5–14), each study has included few patients. Generalizations and broader inferences are difficult from isolated investigations. It is also difficult to assess from isolated studies whether the comparative accuracy of ECG-gated SPECT differs in various patient subgroups. To address these issues, we performed a meta-analysis of all available data comparing ECG-gated SPECT versus cardiac MRI. A patient-level meta-analysis approach enhanced the power of detecting differences between the two methods and maximized accuracy in estimating their magnitude.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Eligibility criteria and search strategy.   We considered studies evaluating LV volumes (end-systolic volume [ESV] and end-diastolic volume [EDV]) and EF by ECG-gated SPECT (using technetium-99m-labeled sestamibi or tetrofosmin or thallium-201) as well as by cardiac MRI in the same subjects. Data were eligible regardless of whether they referred to healthy subjects or patients with suspected or proven disease, and regardless of whether ECG-gated SPECT images were acquired at rest or after stress. Data were also eligible regardless of the technical parameters used for either test and regardless of the algorithm used for LV volumes and EF calculations. Phantom-only and animal studies were excluded.

We identified eligible studies by searching MEDLINE and EMBASE (last search updated December 2001). The search combined the terms "gated," "SPECT," "technetium" or "Tc-99m," "tetrofosmin," "sestamibi," "thallium" or "Tl-201" and "magnetic resonance imaging," "MRI" and "ejection fraction." In addition, we perused bibliographies of retrieved articles and reviews and communicated with experts in the field. Meeting abstracts were excluded because they would not provide individual patient data and their results might not be final.

The retrieved studies were carefully examined to exclude duplication or overlap of subjects. Duplicate/overlapping data were counted only once in the meta-analysis.

Data extraction.   The following information was extracted from each pertinent study: first author, year of publication and journal; study population characteristics including gender, mean age (and standard deviation), clinical setting, selection of subjects (consecutive vs. other), study design (prospective vs. retrospective or unspecified), inclusion and exclusion criteria; relative timing of the two imaging procedures; technical characteristics of the ECG-gated SPECT and the cardiac MRI; blinding of evaluators of one test to the results of the other and to the clinical condition of the tested subject; total number of subjects in the study; number of subjects evaluated with either test and reasons for nonevaluations; quantitative or qualitative assessment of regional thickening; and percentage of subjects with history of myocardial infarction and median EF by cardiac MRI. The two latter parameters were used to characterize the clinical background and average severity of LV dysfunction in the studied population. For each subject, we recorded the EDV, ESV and EF with each imaging modality. Whenever numerical data were not given directly, we extracted the relevant data using scanned computerized images of the pertinent scatter plots and by communication with the study investigators. When ECG-gated SPECT measurements had been corrected by a phantom-study correction factor, analysis was performed both with uncorrected and corrected values.

Data extraction was performed in duplicate by two independent investigators. Discrepancies were solved by consensus and by using a third investigator as arbitrator. We verified that regression analyses from the data of each study replicated the regression coefficients provided in the respective published report, typically within 1%.

Data synthesis.   correlation and regression analyses.
Each identified study had evaluated relatively few subjects. Therefore, the main analysis involved pooling of individual subject data across studies. Scatter plots were generated with ECG-gated SPECT measurements on the y axis and cardiac MRI measurements on the x axis. Pearson correlation coefficients (r) were estimated, and a linear regression was fit to each set of the ECG-gated SPECT versus cardiac MRI data with unweighted least squares estimation for intercept and slope coefficients and 95% confidence intervals (CI). Coefficients of determination (R2) and standard errors of the estimate (SEE) were calculated for each regression. We also estimated correlation coefficients and regression slopes for individual studies and examined whether the regression slopes are significantly heterogeneous. Bland-Altman plots and regressions examined whether the difference in the two measurements varied at different levels of EDV, ESV or EF (15).

frequency of discrepancies and subgroup analyses.
We evaluated the proportion of cases and 95% CI for differences of ≥30 ml in the EDV, ≥20 ml in the ESV and ≥5% or ≥10% in the EF between the two methods. The cutoffs were defined a priori and reflect discrepancies that are likely to be meaningful in situations where substantial accuracy is needed for ventricular volumes and EF. We used both simple pooling and weighted random effects modeling to estimate the overall proportions and 95% CI of differences exceeding the specified cutoffs (16). Between-study heterogeneity was assessed using exact inference for n*2 tables, where n is the number of studies. In the presence of significant heterogeneity, the random effects estimates provide wider CI than simple pooling because they incorporate an estimate of the between-study variance in the calculations. Thus, random effects are preferable when significant heterogeneity is present.

Separate analyses were performed for subgroups defined on the basis of low EF (≤40% by ECG-gated SPECT) versus normal/intermediate EF, normal versus low ESV (70 ml cutoff by ECG-gated SPECT) and blinding parameters. The cutoff EF of 40% is often used clinically to differentiate between mild and significant systolic dysfunction. Selection for the ESV cutoff was based on prognostic data for coronary artery disease (CAD) reported by Sharir et al. (17). We did not use an EDV cutoff, as adjustments for body surface area would be important, but such data were not available. Subgroups were compared to evaluate whether they differed in the concordance of the two methods as expressed by the metrics previously described. In the presented analyses, subgroup estimates are obtained with pooling of the pertinent subjects across the eligible studies, but random effects yielded similar estimates (not shown).

Extent of misclassification
Finally, we evaluated the sensitivity and specificity and overall misclassification rate of ECG-gated SPECT measurements in terms of classifying subjects as having EF >40% versus ≤40%. Sensitivity and specificity values were estimated separately for each study and synthesized by simple pooling and by random effects across studies. Random effects independent synthesis of sensitivity and specificity may tend to underestimate both parameters (18), but a formal summary operating characteristic curve approach (18) was not particularly helpful for these data because the studies tended to operate in the same area of the curve.

Software
Analyses were performed in Advanced SPSS 10.0 (SPSS, Inc., Chicago, Illinois), Meta-Analyst (Joseph Lau, Boston, Massachusetts), Meta-Test (Joseph Lau) and StatXact3 (Cytel, Inc., Boston, Massachusetts). All p values are two-tailed.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Eligibility of studies and extraction of individual patient data.   Thirteen potentially eligible reports were considered (5–14,19–21). Of those, three were excluded because in two studies there was no assessment of volumes (19,20), and one study was performed on experimental animals (21). Two of the remaining publications (5,8) pertained to the same study, and all subjects in one publication were included in the larger dataset of the earlier report; only the earlier report was considered. Another team (10,11) had also published two reports, and 13 of the 16 subjects in one report were included among the 20 subjects of the other report; in the meta-analysis, we considered the 20 subjects of the latter report and the three additional nonoverlapping subjects from the smaller study. In all, information on 164 subjects who had both ECG-gated SPECT and cardiac MRI was analyzed (Table 1).


View this table:
[in this window]
[in a new window]
 
Table 1 Characteristics of Included Studies

 
Characteristics of subjects and of studies.   In most studies, all patients who underwent cardiac MRI also had ECG-gated SPECT and vice versa. However, there were some exceptions (6,9,14). The study population was defined with different criteria across studies, but usually patients had a clinical indication for ECG-gated SPECT, typically related to CAD. Stolfluss et al. (8) also included five healthy subjects. Men accounted for 67% to 95% of each study’s population, and the mean age was characteristic of CAD patients. The proportion of subjects with prior myocardial infarction varied from 42% to 100%, and median EF (by cardiac MRI) ranged between 27% and 65% across studies. Information on the number of segments with absent counts that could not be assessed and on the number of severe defects (photon counts <70% of maximal, absent counts or qualitatively characterized as severe defects) were provided only in two studies (8,11). The time interval between ECG-gated SPECT and cardiac MRI was consistently <1 week in six studies. Three studies (6,12,13) allowed also larger time windows but assured that patients were clinically stable in the interim. Blinded interpretation was not consistently used in all studies (Table 1).

All studies had used Tc-99m sestamibi or tetrofosmin. One study (10) also performed imaging with Tl-201 (in the same study population as for Tc-99m imaging). Concordance of ECG-gated SPECT with cardiac MRI was fairly similar in the Tc-99m and Tl-201 evaluations. All the reported calculations in the meta-analysis use only the Tc-99m data. All studies used rest acquisitions, except for one investigation with 30 patients (14) and 6 of the 21 patients in another study (13). For volumetric MRI measurements, all but one (6) study used the disk-area method (Simpson’s rule). For ECG-gated SPECT measurements, the majority of the studies used an automated quantitative software package (22). Geometrical modeling of the LV based on a single (23) or multiple ventricular dimensions was also used. One study used two different automatic methods of computation of the LV parameters (14), quantitative gated SPECT and Emory cardiac toolbox. The first one is used in the main data synthesis because it is more commonly used. Sensitivity analyses using the data obtained with the other method yielded largely similar results (not shown). Other technical characteristics are shown in Table 2.


View this table:
[in this window]
[in a new window]
 
Table 2 Technical Characteristics of Imaging

 
Pooled analyses.   Overall, there was very good correlation between the ECG-gated SPECT and cardiac MRI measurements (correlation coefficients, 0.89 for EDV, 0.92 for ESV, 0.87 for EF; p < 0.001 for all) (Fig. 1). The correlation was also excellent when limited to studies with all measurements obtained at rest (correlation coefficients, 0.92 for EDV, 0.94 for ESV, 0.90 for EF; p < 0.001). The best-fit regression lines in the pooled analyses for predicting the ECG-gated SPECT values as a function of the cardiac MRI values were as follows: y = 0.84x + 14 for EDV (SEE = 34); y = 0.87x + 12 for ESV (SEE = 26) and y = 0.83x + 5.2% for the EF (SEE = 7.8). The R2 values were 0.80, 0.85 and 0.75, respectively. The regressions suggest that ECG-gated SPECT tends to overestimate EDV and ESV compared with cardiac MRI for values <89 ml, while it tends to overestimate EDV and ESV at higher volumes. The expected ESV difference is 1 ml at ESV = 100 ml. The expected EDV difference is 18 ml at EDV = 200 ml. On average, ECG-gated SPECT tends to overestimate EF when EF is very low (<31%), while it tends to underestimate EF when ventricular function is preserved. The expected difference is 5% at EF = 60%. Results were similar when phantom-study corrections were used for one study (10,11).




View larger version (39K):
[in this window]
[in a new window]
 
Figure 1 Scatter plots of cardiac magnetic resonance imaging (MRI) and electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) measurements in subjects who underwent imaging with both modalities. (A) Left ventricular (LV) end-diastolic volume (EDV) in ml; (B) LV end-systolic volume (ESV) in ml; (C) LV ejection fraction (EF). Patients in the two publications by Tadamura et al. (10,11) are shown as belonging to the same study. End-diastolic volume and ESV data were not provided for individual subjects in Stolfuss et al. (8) and could only be discerned for subjects with substantial discrepancies between cardiac MRI and ECG-gated SPECT in Mochizuki et al. (6) (not shown here, but included in the calculations of the proportion with discrepancies). Faber pertains to reference 9, while FaberB pertains to reference 14.

 
Correlation coefficients were consistently high in all included studies (range: 0.81 to 0.97 for EDV; 0.87 to 0.99 for ESV; 0.72 to 0.93 for EF). However, there was variability in the regression slopes (range: 0.76 to 1.28 for EDV; 0.79 to 1.29 for ESV; 0.65 to 1.10 for EF). Variability in EDV and ESV was largely accounted by the low slopes obtained for the Tadamura et al. (10,11) data (it was substantially reduced when volumes in this study were corrected with a phantom-correction). Variability in EF was largely accounted by the low slope in Faber et al. (14), regardless of the automatic method used for SPECT volume calculation.

The difference between the ECG-gated SPECT and cardiac MRI measurements did not vary substantially at different levels of LV EDV or EF (Fig. 2A and 2C). However, there was a suggestion that for ESV the average difference between the ECG-gated SPECT and cardiac MRI measurements was greater at larger ESV values (p = 0.070) (Fig. 2B).




View larger version (36K):
[in this window]
[in a new window]
 
Figure 2 Bland-Altman plots of the data presented in Figure 2. (A) Left ventricular (LV) end-diastolic volume (EDV) in ml; (B) LV end-systolic volume (ESV) in ml; (C) LV ejection fraction (EF).

 
Discrepancies between ECG-gated SPECT and cardiac MRI.   Despite an overall excellent correlation, considerable discrepancies between the ECG-gated SPECT and cardiac MRI measurements were common for individual subjects (Table 3). There was substantial heterogeneity in the rates of large discrepancies between the included studies, in particular for EF; therefore, weighted random effects calculations are more appropriate than pooling. By random effects, the percentage of large discrepancies was 37% (95% CI, 26% to 50%) for ≥30 ml in EDV, 35% (95% CI, 23% to 49%) for ≥20 ml in ESV, 52% (95% CI, 37% to 63%) for ≥5% in EF and 23% (95% CI, 11% to 42%) for ≥10% in EF.


View this table:
[in this window]
[in a new window]
 
Table 3 Proportion of Differences Between ECG-Gated SPECT and Cardiac MRI Measurements

 
Subgroup analyses.   The frequency of large discrepancies was slightly less common in subjects where the ECG-gated SPECT EF was ≤40% than in those with larger ECG-gated SPECT EF estimates, but the difference was not formally significant. The cardiac MRI EF differed by at least 10% in 12/67 and 28/97 subjects in the two subgroups, respectively (p = 0.10). For differences of ≥5%, the respective proportions were 31/67 versus 53/97 (p = 0.29).

Large discrepancies in the ESV estimates were significantly more common in subjects with SPECT-estimated ESV of <70 ml than those with SPECT-estimated ESV of >70 ml. The rates of discrepancies of ≥20 ml were 12/73 (16%) versus 37/64 (58%) in the two subgroups respectively (p < 0.001). When the cutoff of 70 ml was based on the cardiac MRI measurements, the results were similar (discrepancy rates 15/78 [19%] vs. 34/59 [58%], respectively, p < 0.001).

Finally, the results of four studies where each test had been interpreted blinded to the results of the other did not differ from the results of studies where this was not assured. Similarly, blinding to clinical data did not affect the frequency of discrepancies (not shown).

Misclassification.   The ability of ECG-gated SPECT in identifying subjects with an EF of ≤40% using the MRI as the gold standard was very good across studies. Sensitivity ranged between 50% and 100% across studies; specificity estimates ranged between 75% and 100%. By simple pooling, SPECT correctly diagnosed EF ≤40% in 53 of 58 subjects (sensitivity 91% [95% CI, 80% to 97%]) and correctly found EF >40% in 93 of 106 subjects (specificity 88% [95% CI, 80% to 93%]). Thus, 18 of 164 subjects were misclassified (11%). Random effects calculations estimated a sensitivity of 83% (95% CI, 69% to 92%) and specificity of 84% (95% CI, 75% to 90%), respectively.


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Electrocardiogram-gated SPECT is the most commonly employed technique for simultaneous assessment of LV perfusion and function. Compared with nongated SPECT acquisitions, ECG-gated approaches are better for defining perfusion defects and assessing regional wall motion. They may have particular utility for evaluation of women (24), differentiation of etiology of cardiomyopathy (25) and overall assessment of viability (5,26,27). The measurement of LV EF and volumes with ECG-gated SPECT can be obtained at no additional exposure to radiation, cost or patient discomfort. Information regarding EF and volumes has important prognostic implications in patients with known or suspected CAD (17,28). Automated, reproducible algorithms for LV EF and volume data remove subjectivity from these measurements.

Electrocardiogram-gated SPECT has been tested in several small studies with phantom experiments, animal studies and patient series. However, small series may suffer from large statistical uncertainty and may apply only to specific, selected patient populations. In this meta-analysis we have tried to evaluate on a broader scale the clinical utility of ECG-gated SPECT for measurement of LV EF and volumes. We found a very high correlation between ECG-gated SPECT and cardiac MRI measurements. On average, the two imaging modalities show very good concordance. However, we also found that for measurements on individual subjects, the likelihood of substantial error is considerable.

Per our estimates, half of the ECG-gated SPECT EF determinations may deviate by at least 5% from the cardiac MRI-obtained values, and one of four may deviate by 10% or more. Substantial errors in EDV and ESV calculations are common, and for ESV the average deviation between the two imaging modalities tended to increase with larger LV ESV values. One in nine subjects would be judged by ECG-gated SPECT to be in the wrong category of LV function, when EF must be categorized as being ≤40% or >40%. Thus, ECG-gated SPECT may not be reliable for determination of LV volumes and EF when large accuracy is required, such as in patients with cardiomyopathies, those receiving cardiotoxic chemotherapy and those considered for transplantation and in the evaluation of volumes for clinical research studies.

Measurement error may be even larger in everyday clinical practice. Images in the considered studies were almost exclusively acquired at rest, while ECG-gated SPECT acquisitions are typically performed after stress. In patients with severe CAD, subendocardial perfusion may be decreased, accounting for apparent LV cavity dilation (29,30). For these patients, calculations of LV EF and volumes may be inaccurate, yet these are the patients in whom it would be most important to have accurate assessments. Nevertheless, the one study that used exclusively post-stress images (14) did not show different results from the others. However, there were few patients with low EF in that study, and more evidence should be accumulated in this setting.

The meta-analysis suggests some areas where additional research regarding the accuracy of ECG-gated SPECT for assessment of LV volumes and EF would be warranted. First, in patients with severe perfusion defects: in these patients, severe reduction of photon counts in a myocardial region (or absence of photon counts) may lead to underestimation of regional wall motion, due to inadequate visualization (31). More data are needed on whether newer approaches may overcome this limitation (32). Second, in women: in all studies together, fewer than 30 women were included. A smaller LV cavity in women may cause errors related to partial volume averaging (33). Finally, more experience is needed for Tl-201 imaging. One study suggested good concordance between Tc-99m and Tl-201 imaging (10), but Tl-201 has been reported to have higher variability than Tc-99m in studies that did not use cardiac MRI for comparison (34,35).

In conclusion, ECG-gated SPECT correlates well with cardiac MRI for measurement of LV volumes and EF. However, on an individual patient level, significant errors may occur and, thus, when accurate measurement is required, cardiac MRI is recommended.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
1. DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med. 1995;36:952–955[Abstract/Free Full Text]

2. Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol. 1997;30:1687–1692[Abstract]

3. Cranney GB, Lotan CS, Dean L, Baxley W, Bouchard A, Pohost GM. Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging: validation by calibrated ventricular angiography. Circulation. 1990;82:154–163[Abstract/Free Full Text]

4. Sakuma H, Fujita N, Foo TK, et al. Evaluation of left ventricular volume and mass with breath-hold cine MR imaging. Radiology. 1993;188:377–380[Abstract/Free Full Text]

5. Stollfuss JC, Haas F, Matsunari I, et al. 99m-Tc-tetrofosmin SPECT for prediction of functional recovery defined by MRI in patients with severe left ventricular dysfunction: additional value of gated SPECT. J Nucl Med. 1999;40:1824–1831[Abstract/Free Full Text]

6. Mochizuki T, Murase K, Tanaka H, Kondoh T, Hamamoto K, Tauxe WN. Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin. J Nucl Med. 1997;38:53–57[Abstract/Free Full Text]

7. Vaduganathan P, He Z-X, Vick GW, Manmarian JJ, Verani MS. Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol. 1998;6:3–10

8. Stollfuss JC, Haas F, Matsunari I, et al. Regional myocardial wall thickening and global ejection fraction in patients with low angiographic left ventricular ejection fraction assessed by visual and quantitative resting ECG-gated 99mTc-tetrofosmin single-photon emission tomography and magnetic resonance imaging. Eur J Nucl Med. 1998;25:522–530[CrossRef][Medline]

9. Faber TL, Cooke CD, Folks RD, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med. 1999;40:650–659[Abstract/Free Full Text]

10. Tadamura E, Kudoh T, Motooka M, et al. Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging. J Am Coll Cardiol. 1999;33:991–997[Abstract/Free Full Text]

11. Tadamura E, Kudoh T, Motooka M, et al. Use of technetium-99m sestamibi ECG-gated single-photon emission tomography for the evaluation of left ventricular function coronary artery bypass graft: comparison with three-dimensional magnetic resonance imaging. Eur J Nucl Med. 1999;26:705–712[CrossRef][Medline]

12. Bax JJ, Lamb H, Dibbets P, et al. Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol. 2000;86:1299–1305[CrossRef][Medline]

13. Bevelaar-Croon CDL, Kayser HWM, van der Wall EE, et al. Left ventricular function correlation of quantitative gated SPECT and MR imaging over a wide range of values. Radiology. 2000;217:572–575[Abstract/Free Full Text]

14. Faber TL, Vansant JP, Pettigrew RI, et al. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic imaging: comparison of two methods. J Nucl Cardiol. 2001;8:645–651[CrossRef][Medline]

15. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307–310

16. Fleiss JL. Statistical Methods for Rates and Proportions. New York, NY: Wiley and Sons; 1981.

17. Sharir T, Germano G, Kavanagh PB, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation. 1999;100:1035–1042[Abstract/Free Full Text]

18. Moses LE, Shapiro D, Littenberg B. Combining independent studies of a diagnostic test into a summary ROC curve: data analytic approaches and some additional considerations. Stat Med. 1993;12:1293–1316[Medline]

19. Gunning MG, Anagnostopoulos C, Davies G, et al. Simultaneous assessment of myocardial viability and function for the detection of hibernating myocardium using ECG-gated 99Tcm-tetrofosmin emission tomography: a comparison with 201-Tl emission tomography combined with cine magnetic resonance imaging. Nucl Med Commun. 1999;20:209–214[Medline]

20. Gunning MG, Anagnostopoulos C, Davies G, Forbat SM, Ell PJ, Underwood SR. Gated technetium-99m-tetrofosmin SPECT and cine MRI to assess left ventricular contraction. J Nucl Med. 1997;38:438–442[Abstract/Free Full Text]

21. Vallejo E, Dione DP, Bruni WL, et al. Reproducibility and accuracy of gated SPECT for determination of left ventricular volume and ejection fraction: experimental validation. J Nucl Med. 2000;41:874–882[Abstract/Free Full Text]

22. Germano G, Kavanagh PB, Su HT, et al. Automatic reorientation of three-dimensional transaxial myocardial perfusion SPECT images. J Nucl Med. 1995;36:1107–1114[Abstract/Free Full Text]

23. DePuey EG, Nicols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT. J Nucl Med. 1993;34:1871–1876[Abstract/Free Full Text]

24. Taillefer R, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69–77[Abstract]

25. Danias PG, Ahlberg AW, Clark BA III, et al. Combined assessment of myocardial perfusion and ventricular function with exercise technetium-99m sestamibi gated single-photon emission computed tomography imaging, to differentiate ischemic and nonischemic dilated cardiomyopathies. Am J Cardiol. 1998;82:1253–1258[CrossRef][Medline]

26. Gonzalez P, Massardo T, Munoz A, et al. Is the addition of ECG gating to technetium-99m sestamibi SPECT of value in the assessment of myocardial viability: an evaluation based on two-dimensional echocardiography following revascularization. Eur J Nucl Med. 1996;23:1315–1322[CrossRef][Medline]

27. Levine MG, McGill CC, Ahlberg AW, et al. Functional assessment with electrocardiographic gated single-photon emission computed tomography improves the ability of technetium-99m sestamibi myocardial perfusion imaging to predict myocardial viability in patients undergoing revascularization. Am J Cardiol. 1999;83:1–5[Medline]

28. St. John Sutton M, Pfeffer MA, Plappert T, et al. Quantitative two-dimensional echocardiographic measurements are major predictors of adverse cardiovascular events after acute myocardial infarction: the protective effects of captopril. Circulation. 1994;89:68–75[Abstract/Free Full Text]

29. Iskandrian AS, Heo J, Nguyen T, Lyons E, Paugh E. Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia. Am J Cardiol. 1990;66:807–811[CrossRef][Medline]

30. Marcassa C, Galli M, Baroffio C, Campini R, Giannuzzi P. Transient left ventricular dilation at quantitative stress-rest sestamibi tomography: clinical, electrocardiographic, and angiographic correlates. J Nucl Cardiol. 1999;6:397–405[CrossRef][Medline]

31. Parker JA, Markis JE, Royal HD. Assessment of regional wall motion and perfusion by multigated myocardial scintigraphy after intracoronary Tl-201. Radiology. 1985;154:783–786[Abstract/Free Full Text]

32. Nichols K, DePuey EG, Krasnow N, Lefkowitz D, Rozanski A. Reliability of enhanced gated SPECT in assessing wall motion of severely hypoperfused myocardium: echocardiographic validation. J Nucl Cardiol. 1998;5:387–394[CrossRef][Medline]

33. Nakajima K, Taki J, Higuchi T, et al. Gated SPECT quantification of small hearts: mathematical simulation and clinical application. Eur J Nucl Med. 2000;27:1372–1379[CrossRef][Medline]

34. Hyun IY, Kwan J, Park KS, Lee WH. Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function. J Nucl Cardiol. 2001;8:182–187[CrossRef][Medline]

35. DePuey EG, Parmett S, Ghesani M, Rozanski A, Nichols K, Salensky H. Comparison of Tc-99m sestamibi and Tl-201 gated perfusion SPECT. J Nucl Cardiol. 1999;6:278–285[CrossRef][Medline]




This article has been cited by other articles:


Home page
JNMHome page
D. Knollmann, O. H. Winz, P. T. Meyer, M. Raptis, T. Krohn, K.-C. Koch, and W. M. Schaefer
Gated Myocardial Perfusion SPECT: Algorithm-Specific Influence of Reorientation on Calculation of Left Ventricular Volumes and Ejection Fraction
J. Nucl. Med., October 1, 2008; 49(10): 1636 - 1642.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
T. W. Galema, M. L. Geleijnse, S.-C. Yap, R. T. van Domburg, E. Biagini, W. B. Vletter, and F. J. Ten Cate
Assessment of left ventricular ejection fraction after myocardial infarction using contrast echocardiography
Eur J Echocardiogr, March 1, 2008; 9(2): 250 - 254.
[Abstract] [Full Text] [PDF]


Home page
Br Med BullHome page
M. M. Henneman, J. D. Schuijf, E. E. van der Wall, and J. J. Bax
Non-invasive anatomical and functional imaging for the detection of coronary artery disease
Br. Med. Bull., January 5, 2007; (2007) ldl014v2.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J D Schuijf, L J Shaw, W Wijns, H J Lamb, D Poldermans, A de Roos, E E van der Wall, and J J Bax
Cardiac imaging in coronary artery disease: differing modalities
Heart, August 1, 2005; 91(8): 1110 - 1117.
[Full Text] [PDF]


Home page
JNMHome page
C. Akincioglu, D. S. Berman, H. Nishina, P. B. Kavanagh, P. J. Slomka, A. Abidov, S. Hayes, J. D. Friedman, and G. Germano
Assessment of Diastolic Function Using 16-Frame 99mTc-Sestamibi Gated Myocardial Perfusion SPECT: Normal Values
J. Nucl. Med., July 1, 2005; 46(7): 1102 - 1108.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Schafers, J. Stypmann, M. J. Wilhelm, L. Stegger, P. Kies, S. Hermann, C. Schmidt, G. Breithardt, H. H. Scheld, and O. Schober
Functional Changes After Partial Left Ventriculectomy and Mitral Valve Repair Assessed by Gated Perfusion SPECT
J. Nucl. Med., October 1, 2004; 45(10): 1605 - 1610.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
V. Go, M. R. Bhatt, and R. C. Hendel
The Diagnostic and Prognostic Value of ECG-Gated SPECT Myocardial Perfusion Imaging
J. Nucl. Med., May 1, 2004; 45(5): 912 - 921.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. H.J.A. Slart, J. J. Bax, R. M. de Jong, J. de Boer, H. J. Lamb, P. H. Mook, A. T.M. Willemsen, W. Vaalburg, D. J. van Veldhuisen, and P. L. Jager
Comparison of Gated PET with MRI for Evaluation of Left Ventricular Function in Patients with Coronary Artery Disease
J. Nucl. Med., February 1, 2004; 45(2): 176 - 182.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. M. Schaefer, C. S.A. Lipke, B. Nowak, H.-J. Kaiser, P. Reinartz, A. Buecker, G. A. Krombach, U. Buell, and H. P. Kuhl
Validation of QGS and 4D-MSPECT for Quantification of Left Ventricular Volumes and Ejection Fraction from Gated 18F-FDG PET: Comparison with Cardiac MRI
J. Nucl. Med., January 1, 2004; 45(1): 74 - 79.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. C. Aepfelbacher, S. B. Yeon, K. K. L. Ho, J. A. Parker, and P. G. Danias
ECG-Gated 99mTc Single-Photon Emission CT for Assessment of Right Ventricular Structure and Function: Is the Information Provided Similar to Echocardiography?
Chest, July 1, 2003; 124(1): 227 - 232.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ioannidis, J. P. A.
Right arrow Articles by Danias, P. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ioannidis, J. P. A.
Right arrow Articles by Danias, P. G.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement