cardiology careers collections past issues search home
     

J Am Coll Cardiol, 2002; 39:1706-1708
© 2002 by the American College of Cardiology Foundation
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dangas, G.
Right arrow Articles by Stone, G. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Dangas, G.
Right arrow Articles by Stone, G. W.

LETTER TO THE EDITOR

Reply

George Dangas, MD, PhDa, Roxana Mehran, MDa, Martin Fahy, MSca, Martin B. Leon, MDa and Gregg W. Stone, MDa

a Lenox Hill Heart and Vascular Institute Cardiovascular Research Foundation55 East 59th Street, 6th Floor, New York, New York 10022, USA

gdangas{at}crf.org


We read with interest the letter of Schnyder and Turi, and are not surprised that our study reporting increased complications associated with arteriotomy closure devices (ACD) has engendered such a strong and obviously heartfelt response. When a negative study is generated and subsequently published in the pursuit of academic honesty and patient well-being (our overriding motivation), one must regrettably anticipate one-sided and dogmatic reactions from parties with possible academic, professional or commercial interests at stake. Unfortunately, Schnyder and Turi have seemingly lost the "forest for the trees" in their apparent zeal to promote this subspeciality. We shall attempt to respond point by point to their critique.

The first generation ACDs were approved in the U.S. on the basis of relatively small randomized trials designed to demonstrate shorter times to hemostasis compared with manual compression in patients undergoing diagnostic and interventional procedures. None of these trials were powered to show differences in complication rates. Yet notwithstanding differing patient composition, device sizes and complication definitions, all four studies showed trends toward increased vascular complications with the ACD, despite their application in the tightly controlled environment of a clinical trial (Table 1).


View this table:
[in this window]
[in a new window]
 
Table 1 Instruction for Use of Package Inserts, Data on File, Food and Drug Administration

 
We therefore examined our experience with closure devices in patients undergoing percutaneous coronary intervention (PCI) at the Washington Hospital Center, one of the busiest interventional hospitals in the country, confirming significant increases in hematoma formation, large declines in hematocrit, and need for vascular surgical repair with ACDs (1). Contrary to Schnyder and Turi’s contention, this was not a "retrospective trial" subject to "bias in completeness and quality of information recorded in the hospital chart"; all data were prospectively collected by dedicated research nurses, all field definitions were prespecified, and all adverse events adjudicated. These quality measures far outstrip that of the usual registry based either on retrospective chart review, or physician recollection or documentation.

Schnyder and Turi are correct though in pointing out potential hidden physician prejudices; the operators in the present study were "biased" to tend to use these devices in ideal patients, explaining why procedure duration was less in patients receiving ACDs, and in whom less debulking and more stand-alone angioplasty were performed, requiring smaller sheaths (2). Nonetheless, complications were still increased with closure devices despite these predispositions favoring the ACD group. We further acknowledge that the increased activated clotting time (ACT) levels at the time of closure device insertion likely favored more bleeding in the ACD group (1). However, the ability to withdraw sheaths in the catheter laboratory in the fully anticoagulated patient, rather than waiting 4 to 6 h for sheath extraction in the in-patient telemetry unit prior to manual compression, is a purported advantage of ACDs and the standard way these devices are utilized. Certainly, Schnyder and Turi are not suggesting ACT normalization is required before using a closure device, which would obviate much of the device’s clinical desirability.

Schnyder and Turi criticize the physicians involved in this study as being "largely novices at vascular closure, having apparently failed to adopt them in routine use." The great majority of the closure procedures were performed by four senior physicians, who collectively have performed >25,000 PCI procedures and many more diagnostic angiograms. They note, however, that only ~150 ACD procedures were being done per year in the study by these physicians; this is true if only "interventional" procedures are considered—the same four operators performed approximately two- to threefold this many closure procedures annually on diagnostic patients. Furthermore, the physicians involved have been participating investigators in most of the premarket approval ACD clinical trials. Thus, while we do not profess to possess the expertise of Schnyder and Turi, the volume and experience with ACDs represented in the present report certainly would more than match the real-world qualifications of most centers experienced in both traditional and novel methods of arteriotomy closure.

Schnyder and Turi also repeatedly note that not all patients in our study had a preclosure femoral angiogram. Though we did not collect this data, we believe >90% of patients did undergo such examination, a frequency that is likely greater than at most hospitals using ACDs in the "real world." Indeed, one reason why more patients did not receive closure devices in our study was the low threshold in place to exclude patients upon the identification of disease or calcification at the access site, an excessively low puncture, or small vessel diameter. Furthermore, femoral angiography was not performed in the manual compression group, and cases unsuitable for closure devices on the basis of the angiogram were also included in the manual compression group, both factors that would favor the ACD group. Finally, to our knowledge, no prior study (whether real-world or controlled trial) has ever reported the actual frequency with which the recommended femoral angiogram was in fact performed.

Schnyder and Turi state that "multiple studies have reported far larger experiences" (2–4), taking issue with our statement that large postapproval studies with these devices were lacking. At the time of submission for publication, our analysis of 6,408 interventional procedures was indeed the only large experience with >500 ACDs investigating femoral access complications after PCI; the three referenced single-center studies were published afterward. Regardless, these subsequent experiences largely support our findings.

In the observational study by Cura et al. (2) comparing the outcomes of manual compression with ACDs in 2,918 patients, the suture-based device was associated with increased rates of vascular access site infections (0.5% vs. 0%) and need for surgery (1.0% vs. 0.4%) compared with manual compression, while both suture and collagen plug ACDs resulted in increased rates of retroperitoneal hematoma (despite the institutional requirement for femoral angiograms before device usage), and a trend toward doubling of the rate of access site–related blood transfusions. In the 3,699-patient quality control study of Carey et al. (3), compared with manual compression the collagen plug devices resulted in greater rates of major vascular complications and hospital readmission, whereas both collagen plug and suture-based ACDs increased rates of infection.

Finally, Schnyder and Turi reference the 930-patient study of Balzer et al. (4), in which a suture-based closure device was used in all patients, with no control group. Technical success was achieved in only 92% of patients, and a relatively high rate of patients (7.0%) had an access site complication, including a 4.1% incidence of large hematomas (>6 cm). They described a learning curve for technical success extending beyond 350 treated patients (although it is unclear how many operators performed these procedures, and whether or not the rate of complications decreased with experience in concert with rising device hemostasis rates). In any event, one can question the wisdom of using a costly device to replace something as simple and effective as manual compression if >350 procedures are required for mastery!

Thus, the bulk of data (not rhetoric) generated to date supports the contention that vascular closure devices may increase complications in patients undergoing percutaneous interventional procedures. Certainly, no studies exist to suggest that complications are decreased with these devices. Given the fact that ACDs are used primarily for patient comfort (or more rapid ambulation, although the potential economic gains from early discharge in this regard have not been realized owing to insurance requirements of an overnight stay after PCI for full reimbursement), and add significant capital cost to an already extended healthcare budget, we question whether closure devices should be used in most post-PCI patients prior to demonstration of their safety in an adequately powered postmarket registry study. In this regard we are concerned that Schnyder and Turi, based on no firm academic footing, "use these devices after percutaneous intervention in nearly 100% of ... cases" and feel that further recommendations "should await the results of prospective, randomized studies." While the call for randomized controlled studies can never be criticized, Schnyder and Turi are no doubt aware that such a trial, designed to show noninferiority in vascular complications between manual compression and ACDs with a relative delta of 20%, would require enrollment of >8,000 patients, and will thus never be performed. Moreover, though this is not the first time the researchers have been critical of other investigators’ work in this field (5), to our knowledge they have not reported their own patient outcomes with and without closure devices, which would be welcome.

In the final analysis, in the interest of our patients we must not succumb to the hazards of anecdotal medicine or the lure of the latest and greatest drug or device. For this reason the results of all credible large-scale postmarket studies, whether prospective, retrospective, case-controlled or registry-based, must be seriously considered by the thoughtful operator in light of the physician’s Hippokratic oath—primum non nocere—first, do no harm. A few additional hours of patient comfort or nursing convenience does not justify even a 1% increase in the rate of septic endarteritis, large hematoma, or the need for blood transfusion or vascular surgical repair. Even the Food and Drug Administration, the unconditional guardian of the public health, realizes the limitations inherent in the best intentioned premarket studies, and thus the need for vigorous postmarket surveillance (6). We remain hopeful that with increasing operator experience and technical device evolution the promise of ACDs will be realized, and we implore the collaboration of our physician–scientist, regulatory and industry partners to obtain confirmatory evidence.


    References
 Top
 References
 

  1. Dangas G, Mehran R, Kokolis S, et al. Vascular complications after percutaneous coronary interventions following hemostasis with manual compression versus arteriotomy closure devices. J Am Coll Cardiol. 2001;38:638–641[Abstract/Free Full Text]
  2. Cura FA, Kapadia SR, L’Allier PL, et al. Safety of femoral closure devices after percutaneous coronary interventions in the era of glycoprotein IIb/IIIa platelet blockade. Am J Cardiol. 2000;86:780–782[CrossRef][Medline]
  3. Carey D, Martin JR, Moore CA, Valentine MC, Nygaard TW. Complications of femoral artery closure devices. Cathet Cardiovasc Interv. 2001;52:3–7[CrossRef][Medline]
  4. Balzer JO, Scheinert D, Diebold T, Haufe M, Vogl T, Biamino G. Postinterventional transcutaneous suture of femoral artery access sites in patients with peripheral arterial occlusive disease: a study of 930 patients. Cathet Cardiovasc Interv. 2001;53:174–181[Medline]
  5. Turi ZG. It’s time to seal every artery but... comparing apples and oranges in the vascular sealing literature. Catheter Cardiovasc Interv. 2001;53:443–444[Medline]
  6. Tavris D, Gross T, Gallauresi B, Kessler L. Arteriotomy closure devices—the FDA perspective. (editorial)J Am Coll Cardiol. 2001;38:642–644[Free Full Text]



This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
H. L. Dauerman, R. J. Applegate, and D. J. Cohen
Vascular Closure Devices: The Second Decade
J. Am. Coll. Cardiol., October 23, 2007; 50(17): 1617 - 1626.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dangas, G.
Right arrow Articles by Stone, G. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Dangas, G.
Right arrow Articles by Stone, G. W.

 
  cardiology careers collections past issues search home