Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2001; 38:1668-1674
© 2001 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levenson, J.
Right arrow Articles by Simon, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levenson, J.
Right arrow Articles by Simon, A.

CLINICAL STUDY

Gender differences in wall shear–mediated brachial artery vasoconstriction and vasodilation

Jaime Levenson, MD*,a, Franco Pessana, E. ENG{dagger}, Jerome Gariepy, MDa, Ricardo Armentano, PhD{dagger} and Alain Simon, MDa

a Centre de Médecine Préventive Cardiovasculaire, Institut National de la Santé et de la Recherche Médicale (INSERM), Hôpital Broussais, Paris, France
{dagger} Favaloro University, Buenos Aires, Argentina

Manuscript received February 15, 2001; revised manuscript received July 16, 2001, accepted August 13, 2001.

* Reprint requests and correspondence: Dr. Jaime Levenson, Hôpital Broussais, 96 Rue Didot, 75674, Paris Cedex 14, France
levenso{at}worldnet.fr


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES

We sought to investigate wall shear rate (WSR) and brachial artery diameter (BAD) changes simultaneously and to determine whether any gender differences exist in arterial reactivity.

BACKGROUND

Wall shear rate/stress and arterial reactivity are rarely assessed at the same time. Furthermore, flow-mediated vasoconstriction has received less attention than flow-mediated vasodilation in humans.

METHODS

A new noninvasive evaluation of WSR in the brachial artery, using multigated, pulsed Doppler velocimeter and a double-transducer probe moved and fixed by a robotic system, was developed.

RESULTS

The validity of the system was tested in vitro with calibrated tubes and showed a high correlation (r = 0.98, p < 0.001). In 10 men and 10 women of similar age, induction of low and high shear rates by forearm occlusion produced significant vasoconstriction and vasodilation, respectively. The time lag for maximal BAD changes was 3 min for vasoconstriction and 1 min for vasodilation. A greater half-time for vasodilation (96 ± 6 for men and 86 ± 12 s for women) than for shear rate (31 ± 5 s for men and 34 ± 4 s for women) was observed after discontinuation of occlusion. Relative BAD was correlated with WSR changes, showing a significantly higher slope in women than in men (p < 0.01). Moreover, a larger normalized arterial diameter per shear rate was observed for vasoconstriction (p < 0.01) and vasodilation (p < 0.01) in women than in men.

CONCLUSIONS

Shear-mediated arterial vasodilation and vasoconstriction were more pronounced in women than in men, suggesting different gender-related sensitivity in the regulation of large-artery vascular tone.

Abbreviations and Acronyms
  BAD = brachial artery diameter
  BMI = body mass index
  DBP = diastolic blood pressure
  HR = heart rate
  SBP = systolic blood pressure
  WSR = wall shear rate


Postischemic dilation of the brachial artery was reported to be greater in premenopausal women than in men (1,2). In addition, flow-mediated vasodilation was found to be decreased in postmenopausal women and improved after estrogen supplementation (3,4). These studies were restricted to arterial changes induced by an increase in blood flow during reactive hyperemia. However, there is evidence that acute induction of low flow constricts the brachial artery (5,6). As yet, there are no studies that examine the possible gender difference in flow-induced arterial constriction during forearm occlusion.

Another important issue of flow-mediated arterial changes is that the stimuli inducing reactive constriction or dilation (i.e., shear rate/stress) are rarely measured at the same time as arterial responses. In addition, flow is not independent of diameter, because it is calculated from diameter and velocity measurements.

The development of multigated ultrasonography has made possible the transcutaneous assessment of the velocity profile (i.e., the distribution of instantaneous velocity along the vessel’s cross section), as well as assessment of the shear rate at discrete intervals during the cardiac cycle (7). In the present report, we used a multigated, pulsed Doppler velocimeter, which offers unique features to measure, in real time, a complete velocity profile and to assess wall shear rate (WSR) and brachial artery diameter (BAD) simultaneously. In addition, a robotic system was applied to select, translate and keep in place, over the course of the artery, the ultrasonic probe, thus improving the precision of the measurements.

The goals of this study were: 1) to test whether shear-induced constriction and dilation exist in the brachial artery of women and men; and 2) to determine the time course of arterial changes of low and high wall shear during and after occlusion of the forearm circulation.

In this study, we hypothesized that acute low and high shear stress would be associated with gender differences in arterial constriction and dilation.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Ultrasonic multigated velocimetry.   The multigated Doppler velocimeter (DOP1000, Signal Processing, Lausanne, Switzerland) is able to instantaneously measure velocity profiles of a peripheral large artery based on the following characteristics: emission frequency of 10 MHz; 248 selectable pulse repetition frequency; a number of gates between 10 and 224; and minimal spatial and temporal resolutions of 0.3 mm and 3 ms, respectively. The number of emissions per profile can be selected at any value between 8 and 512, and this system can be controlled by an external trigger or electrocardiographic synchronization. A previously developed double-transducer probe formed between them an angle of 120° permits adjustment of the incident angle of the ultrasonic beam at 60 ± 1° to the arterial axis (8,9).

The velocimeter records data profiles in ASCII format. Off-line signal processing was carried out using an algorithm enabling the calculation of the arterial diameter and shear rate, developed in MatLab 5.3 (Math Works Inc., Natick, Massachusetts). From the acquired instantaneous velocity profiles, a mean profile was obtained. Mean BAD was calculated from the intersection of the zero velocity line and the straight lines obtained from linear extrapolation of the first portion of the velocity profile at the anterior and posterior walls. Mean WSR was estimated from averaged peak values of the derivatives of the velocity profile at the anterior and posterior walls.

Robotic system.   The robot, a prototype called Hippocrate (SINTERS, Toulouse, France) (10), was compliant with European Community marking, intrinsically safe and approved for clinical investigation by the Ethics Committee of Henry Mondor Hospital. Practically, Hippocrate consists of a robotic arm with 6 degrees of freedom adjustment—three in translation and three in rotation by minimal steps of 0.1 mm and 0.5°, respectively. The transducer probe was attached to the robotic arm for its precise micromanipulation and positioning. The system allows movement of the probe in a step-by-step manner on the arterial target, while applying a programmable and constant force, as well as documentation of its successive spatial location. Force control is necessary to provide good and reproducible conduction of the ultrasonic signals, while preventing arterial deformation. A joystick device permits the selection, translation and rotation of the ultrasonic probe on the six axis positions.

Procedure.   First of all, the arm containing the ultrasonic probe was moved from the home position to the vicinity of the measuring zone—the brachial artery over the antecubital fossa. The desired force (60 to 100 g), the step-to-step displacement and the degree of rotation were designed on the computer. When the configuration of the procedure was stored, the robotic arm was translated perpendicularly to the plane formed by the two emitted ultrasonic beams until the apparition of a velocity profile on one transducer. Thereafter, the probe was translated in the same direction to obtain a velocity profile from the second transducer. With the rotation system, the probe was adjusted until the ultrasonic plane was parallel to the vessel’s axis. Then, the probe was translated by intervals of 0.1 or 0.2 mm from the proximal to the distal wall to place the probe at half of the vessel’s diameter. In this position, the probe was rotated around an axis perpendicular to its plane until the responses on each transducer were equal in absolute values. In this case, the ultrasonic incidence angle was 60°.

Laboratory testing.   To validate the measurements obtained with the multigated velocimeter, in vitro experiments were performed on a hydrodynamic model. For this, laminar flow (14 to 60 ml/min) of viscous fluid suspension of silicon oil particles in water (2.19 mPa · s) was imposed inside rigid, calibrated, rectilinear ducts (4, 5, 6, 7 and 8 mm) and immersed in a water tank.

Subjects and study design.   Twenty healthy volunteers (10 women [22 to 50 years old] and 10 men [23 to 45 years old]) from the hospital staff were enrolled in this study. Informed consent for the study was obtained from the subjects after they were given a detailed description of the procedure. The 10 women had regular menstrual cycles for more than three months before this study. All were in the first phase of their menstrual cycle, but no blood samples were obtained to confirm this state. All subjects were asymptomatic, normotensive and nondiabetic and were not taking any medications (except for 5 women using oral contraceptives). All subjects abstained from alcohol and caffeine for 8 h before the study. The investigation was performed with the subject in the supine position, at a controlled room temperature of 22 ± 1°C, after 15 min of rest, with the right arm fixed to restrict movement at the mid-thoracic level. After baseline measurements were obtained after 15 min, an occluding cuff placed ~8 cm distal to the site of brachial artery determination was inflated to a pressure of 250 mm Hg for 300 s. The velocity profile was determined for each probe at an interval of 60 s for 300 s during arrest of forearm circulation and at 20, 60, 90, 120, 180, 240, 300, 360, 480 and 600 s after release of arterial occlusion. Figure 1 shows an example of instantaneous velocity profiles before, during and after occlusion. Blood pressure was monitored in the left arm at the same time as the instantaneous velocity profile acquisition by use of an automated blood pressure recorder (Omron HEM 705CP, Tokyo, Japan).



View larger version (30K):
[in this window]
[in a new window]
 
Figure 1 Representative tracings of brachial artery velocity profiles for one subject assessed by Doppler multigated velocimetry at baseline (left), during forearm occlusion at 180 s (center) and after 20 s of reactive hyperemia (right). Bold lines represent the mean value of at least 200 velocity profiles at each condition.

 
Statistical analysis.   Data are expressed as the mean value ± SEM. Group differences were determined by the Student t test. Linear regression analysis was performed using the least squares method. The differences in slopes were determined by analysis of covariance. Agreement between the actual diameter of the calibrated tubes and the calculated multigated velocimetric measurement was analyzed according to the Bland-Altman approach (11). The time course differences were determined by repeated measures analysis of variance, followed by the Bonferroni post hoc test. The half-time decay (in seconds) of WSR and BAD during hyperemia was analyzed with a semi–log-plot. Multivariate regression analysis with WSR-induced dilation or constriction as the dependent variable and age, body mass index (BMI), systolic blood pressure (SBP), diastolic blood pressure (DBP) and heart rate (HR) as the independent variables were evaluated. Statistical significance was set at p < 0.05.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Laboratory and clinical testing.   A strong positive linear relationship was found between the actual diameter of the calibrated tubes and those calculated from the velocity profile algorithm (r = 0.98), with a slope of 0.99 ± 0.01 and an intercept of 0.24 ± 0.11 mm. The mean difference (ducts minus multigated velocimeter) was –0.21, with a 95% confidence interval of –0.69 to 0.27 mm (Fig. 2).



View larger version (11K):
[in this window]
[in a new window]
 
Figure 2 (Left) Measured diameter obtained by Doppler multigated velocimetry, as compared with true tube values. (Right) Difference in mean value between the measured diameter obtained by Doppler multigated velocimetry and the actual tube diameter value.

 
The intrasubject and intersubject variabilities for 200, 400 and 1,000 velocity profiles obtained at each probe in 16 subjects are depicted in Table 1. The mean average was <3% for BAD and <6% for WSR. To evaluate the reproducibility, the examination was repeated two times for each transducer at a one-week interval in nine subjects. The coefficients of variation for repeated measurements for BAD and WSR were <4% and 7% at baseline, 3% and 7% at 300-s occlusion and 2% and 6% at 20-s hyperemia, respectively (Table 1).


View this table:
[in this window]
[in a new window]
 
Table 1 Intrasubject and Intersubject Variabilities and Reproducibilities

 
Clinical study.   No differences in age, BMI, DBP, HR, WSR or blood flow were observed in women as compared with men. Systolic blood pressure (p < 0.05) and mean BAD (p < 0.01) were higher in men than in women (Table 2).


View this table:
[in this window]
[in a new window]
 
Table 2 Characteristics of Study Groups

 
Shear-mediated constriction.   Sixty seconds after arterial occlusion, WSR and blood flow decreased from 91 ± 12 to 42 ± 7 s–1 and from 42 ± 8 to 11 ± 1 ml/min (p < 0.001) in women and from 89 ± 18 to 28 ± 5 s–1 and from 51 ± 10 to 10 ± 2 ml/min (p < 0.001) in men, respectively. Although the decrease in WSR was lower in women than in men (p < 0.01), blood flow did not differ. The reduction in WSR and blood flow persisted during the 300 s of cuff occlusion and was associated with a significant reduction in the mean arterial diameter (Fig. 3). The maximal diameter reduction was observed at 180 s—from 4.18 ± 0.15 to 3.43 ± 0.17 mm in women (p < 0.001) and from 4.62 ± 0.11 to 3.86 ± 0.12 mm (p < 0.001) in men. The absolute change in diameter was not different between women and men. However, because the decrease in WSR was lower in women than in men, the percent change in BAD induced by the decrease in WSR was normalized for each subject in both groups (percent change in BAD/percent change in WSR x 100). The ratio of BAD to WSR was significantly greater in women than in men (39 ± 2.8 for women and 19 ± 1.2 for men; p < 0.01) (Fig. 4). Systolic blood pressure, DBP and HR did not change significantly during occlusion in women (108 ± 3 and 68 ± 2 mm Hg and 72 ± 3 beats/min, respectively) and men (119 ± 2 and 70 ± 3 mm Hg and 67 ± 3 beats/min, respectively).



View larger version (24K):
[in this window]
[in a new window]
 
Figure 3 Time course of the entire duration of brachial wall shear rate and diameter measurements at baseline and during occlusion and reactive hyperemia in men and women.

 


View larger version (20K):
[in this window]
[in a new window]
 
Figure 4 (Left bars) Changes in brachial diameter during arterial occlusion at 3 min, normalized for changes in wall shear rate at the same time. (Right bars) Changes in diameter after 1-min release of arterial occlusion, normalized for the maximal changes in wall shear at 20 s. {dagger}p < 0.01.

 
Shear-mediated dilation.   Twenty seconds after release of occlusion, WSR and blood flow increased to 211 ± 28 s–1 and to 132 ± 24 ml/min (p < 0.001 vs. baseline) in women and to 259 ± 33 s–1 and 163 ± 19 ml/min (p < 0.001 vs. baseline) in men, respectively. In response to the increase in WSR, maximal arterial dilation was noted at 60 s and reached 4.64 ± 0.19 mm in women (p < 0.001 vs. baseline) and 4.94 ± 0.12 mm in men (p < 0.001 vs. baseline). The absolute (0.45 ± 0.13 and 0.32 ± 0.11 mm; p < 0.05) and percent change (11 ± 4% and 7 ± 3%; p < 0.01) in BAD was significantly increased in women as compared with men. The ratio of BAD to WSR changes was significantly greater in women than in men (9.5 ± 1.2 for women and 4.5 ± 0.8 for men; p < 0.01) (Fig. 4). The return of BAD to the basal condition (86 ± 12 for women and 96 ± 19 s for men) was slower than that of WSR (34 ± 4 for women and 31 ± 5 s for men; p < 0.05) (Fig. 3). Systolic blood pressure, DBP and HR did not change significantly during release of occlusion in women (110 ± 2 and 67 ± 2 mm Hg and 72 ± 3 beats/min, respectively) and men (113 ± 1 and 64 ± 2 mm Hg and 69 ± 3 beats/min, respectively).

Multivariate and regression analyses.   On multivariate analysis of the group as a whole or in separate gender groups, shear-induced constriction or dilation was not significantly related to age, BMI, HR, SBP or DBP.

The percent changes in BAD were positively correlated with the percent changes in shear rate in women (y = 0.1842 x +0.3064; r = 0.81, p < 0.01) and men (y = 0.0734 x –3.964; r = 0.79, p < 0.01), with a regression line significantly different between groups (p < 0.01) (Fig. 5).



View larger version (18K):
[in this window]
[in a new window]
 
Figure 5 Scatterplot showing regression lines between brachial artery diameter and shear rate changes during the entire time course of the study (see Fig. 3). Each point for women and men corresponds to the mean percent change from baseline of the 5 measurements obtained during occlusion and the 10 measurements obtained after release of the occlusion. Solid circles represent men: y = 0.0734 x –3.964, r = 0.79, p < 0.01; open circles represent women: y = 0.1842 x +0.3064, r = 0.81, p < 0.01. Slope difference: p < 0.01. Note that the maximal increase in shear in men (282 ± 62%) and women (131 ± 28%) at 20 s is reached before the maximal increase in diameter. The exclusion of these points did not affect the significance of the regression.

 

    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
The main finding of this study is that women had more pronounced shear-mediated arterial vasodilation and vasoconstriction, as compared with men. A distinctive feature of our work is that the arterial diameter variations are expressed as a result of changes in WSR, because shear forces are the real effectors on the endothelial surface. The gender difference in shear-dependent modulation of BAD during ischemia and hyperemia was supported by the greater diameter per WSR changes for either vasoconstriction or vasodilation, as well as the higher slope, in women as compared with men, of a strong linear correlation between relative changes in WSR and BAD. A greater flow-mediated vasodilation has been previously documented in women as compared with men. During the normal menstrual cycle, flow-mediated vasodilation increases significantly during the follicular and luteal phases, when serum estradiol levels are high (1). In addition, reduced flow-mediated dilation with aging was reported to appear earlier in men as compared with women (2). The greater shear-mediated vasoconstriction in women, as compared with men, is an original finding of the present investigation. The effect of low flow on the arterial diameter has received less attention in clinical investigation. Previous studies have clearly demonstrated that high flow dilates and low flow constricts the brachial artery (5,6). Enhanced constriction of the brachial artery in response to acute induction of a low-flow state was described in hypercholesterolemic subjects (12), an effect that was attenuated with hepatic hydroxymethyl glutaryl coenzyme A reductase inhibitors (13).

There are several lines of evidence that endothelial vasodilator functions are modulated by estrogen. Estrogen administration improves endothelium-dependent relaxation by increasing production/release, or less degradation, of nitric oxide (3,14). Other potential mechanisms of estrogen on vasodilation include higher stimulation of endothelial potassium channels (15), reduction of superoxide anion production (16) or upregulation of superoxide dismutase (17). The mechanisms of increased shear-mediated vasoconstriction in women cannot be addressed by the present study design. Endothelium-dependent contractions were explained either by withdrawal of the effect of endothelium-derived relaxation factors or by production of endothelium-contracting factors (e.g., superoxide anions, thromboxane A2 and endothelin-1) (18).

Time course for shear-mediated arterial constriction and dilation.   Although WSR declines and rises rapidly during occlusion and release of the forearm circulation, time lags for BAD changes were observed. Shear-induced maximal vasoconstriction occurred 3 min after occlusion, whereas maximal shear-induced vasodilation appeared 1 min after release of the forearm occlusion. The latter was in line with the time delay reported for peak vasodilation in experimental and human studies (6,19), as well as the biologic half-time for flow-mediated release of endothelial relaxing factors (20). The delayed vasoconstrictor response of the brachial artery observed in the present study needs further investigation to determine whether the acute regulation of the arterial diameter requires a longer time scale for contracting factor release. Previous studies have shown that a rapid response to increased shear-related vasorelaxation was observed with nitric oxide and prostacyclin, whereas the potent vasoconstrictor endothelin-1 appears to be reduced by an increase in shear stress and released by low shear stress on a much longer time course (21).

When peak WSR declines, BAD does not immediately return completely to the predilation size. The half-time of vasodilation after discontinuation of forearm occlusion was larger than the half-time of wall shear. This result reinforces the hypothesis that the endothelium sensed wall shear stress, thus releasing vasodilating substances to restore its values to those experienced before the change in flow. The acute vasodilation of the arterial lumen by shear stress probably limits the pressure increase induced by the rise in blood flow, thus restraining mechanical energy losses. There is a possibility that changes in wall shear stress may induce a myogenic response due to transmural pressure modification. However, in our study, shear-mediated vasoconstriction or vasodilation occurred independently of changes in blood pressure.

Clinical significance.   Although flow-induced vasodilation is frequently used to characterize endothelial function, decreased flow and low shear stress are most often associated with endothelium-dependent vasoconstriction (22), intimal hyperplasia (23) and accelerated atherosclerosis (24,25). Patients with unstable angina and myocardial infarction usually have an abrupt reduction in coronary flow (26). The vasoconstriction and possible consecutive release of contracting factors induced by low shear stress may further impede coronary flow and aggravate heart disease.

The epidemiologic observation that cardiovascular disease is more frequent in men and postmenopausal women than in premenopausal women suggests vascular protective effects of women’s sex hormones (27). However, it was also reported that women who develop coronary artery disease have a poorer prognosis as compared with men, with more early deaths after acute myocardial infarction and higher in-hospital mortality rates after coronary angioplasty, atherectomy or bypass surgery (28). It was also observed that after chest pain, women are more likely than men to have normal coronary artery angiograms (29). In addition, myocardial ischemia was common during intracoronary ultrasonography in women with and without coronary artery disease (30). From the results of this study, we cannot conclude how significant is the hyper-responsiveness of the brachial artery to render women more vulnerable than men to the development of higher coronary vasoconstriction in the presence of coronary artery disease. Further studies are required to determine whether shear-dependent vasoconstriction could be related to these observations.

Study limitations.   A first possible limitation of the current study is related to the determination of BAD and WSR with the DOP1000. To remove the low frequency components generated by the movements of the vessel walls without losing the low blood flow velocities close to the wall (7), a digital second-order high-pass filter is used. This filter is set up to achieve a cut-off frequency near PRF/64, where PRF is the pulse repetition frequency of the ultrasonic emissions. This solution allows a sufficient dynamic range enabling measurement of low velocities near the walls. Because of the limited resolution due to the finite size of the sample volume (7), the mean WSR was estimated from the average peak values of the derivative of the velocity profile at the anterior and posterior walls. The association between the double-transducer probe and the robotic system serves to improve the reliability of these measurements. This was demonstrated by the low variations of WSR—namely, the arterial diameter—when 200, 400 or 1,000 velocity profiles were determined. In addition, the mean difference in diameter obtained with the calibrated tubes was <3.5%, which is much smaller than the mean difference between the baseline value and vasoconstriction and the baseline value and vasodilation, as well as the difference between men and women.

Our approach is limited by the fact that blood viscosity was not measured. Because shear stress is dependent on both shear rate and fluid viscosity, an increase or decrease in either should cause parallel changes in arterial reactivity. The expected lower blood viscosity in women (31) may still induce lower shear stress, without changing the main results observed in the study. A final limitation of our study was the lack of provocative endothelium-independent vasodilation and constriction, because gender differences of the sensitivity of the vascular smooth muscle are another possible mechanism of shear-induced release of vasoactive substances.

Conclusions.   This study provides an original method to assess WSR and arterial reactivity simultaneously in humans. Shear-mediated arterial vasodilation and vasoconstriction were more pronounced in women than in men, which suggests different gender sensitivities in the regulation of large-artery vascular tone. Further investigation in a larger sample of subjects is required to confirm the observation of higher shear-dependent vasoconstriction of the brachial artery in women and to determine the mechanism of these gender differences.


    Footnotes
 
This work was supported by ECOS-SECyT (A97S03), INSERM (CRI 4U010B) and Electricité de France.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
1. Hashimoto M, Akishita M, Eto M, et al. Modulation of endothelium-dependent flow-mediated dilatation of the brachial artery by sex and menstrual cycle. Circulation. 1995;92:3431–3435[Abstract/Free Full Text]

2. Celermajer DS, Sorensen KE, Spiegelhalter DJ, Georgakopoulos D, Robinson J, Deanfield JE. Aging is associated with endothelial dysfunction in healthy men years before the age-related decline in women. J Am Coll Cardiol. 1994;24:471–476[Abstract]

3. Kawano H, Motoyama T, Kugiyama K, et al. Gender difference in improvement of endothellium-dependent vasodilatation after estrogen supplementation. J Am Coll Cardiol. 1997;30:914–919[Abstract]

4. Gerhard M, Walsh WB, Tawakol A, et al. Estradiol therapy combined with progesterone and endothelium-dependent vasodilation in postmenopausal women. Circulation. 1998;98:1158–1163[Abstract/Free Full Text]

5. Anderson EA, Mark AL. Flow-mediated and reflex changes in large peripheral artery tone in humans. Circulation. 1989;79:93–100[Abstract/Free Full Text]

6. Sinoway LI, Hendrickson C, Davidson WR, Prophet S, Zelis R. Characteristics of flow-mediated brachial artery vasodilatation in human subjects. Circ Res. 1989;64:32–42[Abstract/Free Full Text]

7. Reneman RS, Hoeks APG. Noninvasive vascular ultrasound: an asset in vascular medicine. Cardiovasc Res. 2000;45:27–35[Free Full Text]

8. Levenson JA, Peronneau PP, Simon AC, Safar ME. Pulsed Doppler: determination of diameter blood flow velocity and volumic flow of brachial artery in man. Cardiovasc Res. 1981;15:164–170[Medline]

9. Levenson J, Simon A, Pithois Merli I. Brachial arterial changes in response to wrist occlusion in normotensive and hypertensive men. Am J Physiol. 1987;253:H217–H224[Medline]

10. Pierrot F, Dombre E, Degoulange E, et al. Hippocrate: a safe robot arm for medical applications with force feedback. Med Image Anal. 1999;3:285–300[CrossRef][Medline]

11. Bland JM, Altman DJ. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet. 1986;1:307–310[CrossRef][Medline]

12. Filitti V, Giral P, Simon A, Merli I, Del Pino M, Levenson J. Enhanced constriction of the peripheral large artery in response to acute induction of a low-flow state in human hypercholesterolemia. Arterioscler Thromb. 1991;11:161–166[Abstract/Free Full Text]

13. Megnien JL, Simon A, Andriani A, Segond P, Jeannin S, Levenson J. Cholesterol lowering therapy inhibits the low-flow mediated vasoconstriction of the brachial artery in hypercholesterolemic subjects. Br J Clin Pharmacol. 1996;42:187–193[CrossRef][Medline]

14. Huang A, Sun D, Koller A, Kaley G. Gender difference in flow-induced dilation and regulation of shear stress: role of estrogen and nitric oxide. Am J Physiol (Regulatory Integrative Comp). 1998;275:R1571–R1577

15. White RM, Rivera CO, Davison CA. Nitric oxide-dependent and -independent mechanisms account for gender differences in vasodilation to acetylcholine. J Pharmacol Exp. 2000;292:375–380

16. Mchugh NA, Merrill GF, Powell SR. Estrogen diminishes postischemic hydroxyl radical production. Am J Physiol (Heart Circ Physiol). 1998;274:H1950–H1954[Abstract/Free Full Text]

17. Ghanam K, Javellaud J, Ea-Kim L, Oudart N. The protective effect of 17ß-estradiol on vasomotor responses of aorta from cholesterol-fed rabbit is reduced by inhibitors of superoxide dismutase and catalase. Biochem Biophys Res Commun. 1998;249:858–864[CrossRef][Medline]

18. Shimokawa H, Vanhoutte PM. Endothelium and vascular injury in hypertension and atherosclerosis. Zanchetti A, Mancia G. Handbook of Hypertension. New York, NY: Elsevier Science; 1997. p. 1007–1065

19. Pohl U, Holtz J, Busse R, Basseneg E. Crucial role of endothelium in the vasodilator response to increased flow in vivo. Hypertension. 1986;8:37–44[Abstract/Free Full Text]

20. Rubanyi GM, Romero JC, Vanhoutte PM. Flow-induced release of endothelium-derived relaxing factor. Am J Physiol. 1986;231:H405–H407

21. Nollert MU, Diamond SL, McIntire LV. Hydrodynamic shear stress and mass transport modulation of endothelial cell metabolism. Biotechnol Bioeng. 1991;38:588–602[Medline]

22. Langille BL, O’Donnel F. Reductions in arterial diameter produced by chronic decreases in blood flow are endothelium-dependent. Science. 1986;231:405–407[Abstract/Free Full Text]

23. Geary RL, Kohler TR, Vergel S, Kirkman TR, Clowes AW. Time course of flow-induced smooth muscle cell proliferation and intimal thickening in endothelialized baboon vascular grafts. Circ Res. 1993;74:14–23

24. Ku DN, Giddens DP, Zarins CK, Glagov S. Pulsatile flow and atherosclerosis in the human carotid bifurcation: positive correlation between plaque location and low and oscillating shear stress. Arteriosclerosis. 1985;5:293–302[Abstract/Free Full Text]

25. Davies PF, Robotewskyj A, Griem ML, Dull RO, Polacek DC. Hemodynamic forces and vascular cell communication in arteries. Arch Pathol Lab Med. 1992;116:1301–1306[Medline]

26. Fuster V, Badimon L, Badimon JJ, Chesebro JH. The pathogenesis of coronary artery disease and the acute coronary syndromes. N Engl J Med. 1992;3126:242–250

27. Lerner DJ, Kannel WB. Patterns of coronary heart disease morbidity and mortality in the sexes: a 26-year follow-up of the Framingham population. Am Heart J. 1986;111:383–390[CrossRef][Medline]

28. Keller KB, Lemberg L. Gender differences in acute coronary events. Am J Crit Care. 2000;3:207–209

29. Davis KB, Chaitman B, Ryan T, Bittner V, Kennedy JW. Comparison of 15-year survival for men and women after initial medical or surgical treatment for coronary artery disease: a CASS Registry study. J Am Coll Cardiol. 1995;25:1000–1009[Abstract]

30. Lau KY, Wung SF, Adams MG, Zellner C, Drew BJ. Frequency of ischemia during intracoronary ultrasound in women with and without coronary artery disease. Crit Care Nurse. 1999;19:48–56[Abstract]

31. Bonithon-Kopp C, Levenson J, Scarabin PY, et al. Longitudinal associations between plasma viscosity and cardiovascular risk factors in a middle-aged French population. Atherosclerosis. 1993;104:173–182[CrossRef][Medline]




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. K. Nishiyama, D. W. Wray, and R. S. Richardson
Sex and limb-specific ischemic reperfusion and vascular reactivity
Am J Physiol Heart Circ Physiol, September 1, 2008; 295(3): H1100 - H1108.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. H. J. Thijssen, M. Kooijman, P. C. E. de Groot, M. W. P. Bleeker, P. Smits, D. J. Green, and M. T. E. Hopman
Endothelium-dependent and -independent vasodilation of the superficial femoral artery in spinal cord-injured subjects
J Appl Physiol, May 1, 2008; 104(5): 1387 - 1393.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. U. Gonzales, B. C. Thompson, J. R. Thistlethwaite, A. J. Harper, and B. W. Scheuermann
Forearm blood flow follows work rate during submaximal dynamic forearm exercise independent of sex
J Appl Physiol, December 1, 2007; 103(6): 1950 - 1957.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. A. Parker, S. L. Smithmyer, J. A. Pelberg, A. D. Mishkin, M. D. Herr, and D. N. Proctor
Sex differences in leg vasodilation during graded knee extensor exercise in young adults
J Appl Physiol, November 1, 2007; 103(5): 1583 - 1591.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. K. Nishiyama, D. Walter Wray, K. Berkstresser, M. Ramaswamy, and R. S. Richardson
Limb-specific differences in flow-mediated dilation: the role of shear rate
J Appl Physiol, September 1, 2007; 103(3): 843 - 851.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. E. Pyke and M. E. Tschakovsky
Peak vs. total reactive hyperemia: which determines the magnitude of flow-mediated dilation?
J Appl Physiol, April 1, 2007; 102(4): 1510 - 1519.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. H. J. Thijssen, P. de Groot, M. Kooijman, P. Smits, and M. T. E. Hopman
Sympathetic nervous system contributes to the age-related impairment of flow-mediated dilation of the superficial femoral artery
Am J Physiol Heart Circ Physiol, December 1, 2006; 291(6): H3122 - H3129.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
B. A. Parker, S. J. Ridout, and D. N. Proctor
Age and flow-mediated dilation: a comparison of dilatory responsiveness in the brachial and popliteal arteries
Am J Physiol Heart Circ Physiol, December 1, 2006; 291(6): H3043 - H3049.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. W. Wray, A. Uberoi, L. Lawrenson, and R. S. Richardson
Evidence of preserved endothelial function and vascular plasticity with age
Am J Physiol Heart Circ Physiol, March 1, 2006; 290(3): H1271 - H1277.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
I. Eskurza, L. A Myerburgh, Z. D Kahn, and D. R Seals
Tetrahydrobiopterin augments endothelium-dependent dilatation in sedentary but not in habitually exercising older adults
J. Physiol., November 1, 2005; 568(3): 1057 - 1065.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
K. E Pyke and M. E Tschakovsky
The relationship between shear stress and flow-mediated dilatation: implications for the assessment of endothelial function
J. Physiol., October 15, 2005; 568(2): 357 - 369.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. A. Parker and D. N. Proctor
Flow-mediated dilation
J Appl Physiol, October 1, 2005; 99(4): 1620 - 1620.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. W. P. Bleeker, P. C. E. De Groot, G. A. Rongen, J. Rittweger, D. Felsenberg, P. Smits, and M. T. E. Hopman
Vascular adaptation to deconditioning and the effect of an exercise countermeasure: results of the Berlin Bed Rest study
J Appl Physiol, October 1, 2005; 99(4): 1293 - 1300.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. W. P. Bleeker, P. C. E. De Groot, F. Poelkens, G. A. Rongen, P. Smits, and M. T. E. Hopman
Vascular adaptation to 4 wk of deconditioning by unilateral lower limb suspension
Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1747 - H1755.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. L. Bots, J. Westerink, T. J. Rabelink, and E. J.P. de Koning
Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response
Eur. Heart J., February 2, 2005; 26(4): 363 - 368.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. A. Silber, P. Ouyang, D. A. Bluemke, S. N. Gupta, T. K. Foo, and J. A. C. Lima
Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging
Am J Physiol Heart Circ Physiol, February 1, 2005; 288(2): H822 - H828.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. E. Pyke, E. M. Dwyer, and M. E. Tschakovsky
Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans
J Appl Physiol, August 1, 2004; 97(2): 499 - 508.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. C. E. de Groot, F. Poelkens, M. Kooijman, and M. T. E. Hopman
Preserved flow-mediated dilation in the inactive legs of spinal cord-injured individuals
Am J Physiol Heart Circ Physiol, July 1, 2004; 287(1): H374 - H380.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. Mueller, F.-J. Neumann, H. Roskamm, P. Buser, J. Mc. B. Hodgson, A. P. Perruchoud, and H. J. Buettner
Women do have an improved long-term outcome after non-ST-elevation acute coronary syndromes treated very early and predominantly with percutaneous coronary intervention: A prospective study in 1,450 consecutive patients
J. Am. Coll. Cardiol., July 17, 2002; 40(2): 245 - 250.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levenson, J.
Right arrow Articles by Simon, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levenson, J.
Right arrow Articles by Simon, A.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement