Correction
for
Kinnaird et al., J Am Coll Cardiol 37 (8) 2025-2030.
Corrections
Kinnaird TD, Thompson CR, Munt BI. The Deceleration Time of Pulmonary Venous Diastolic Flow Is More Accurate Than the Pulmonary Artery Occlusion Pressure in Predicting Left Atrial Pressure. J Am Coll Cardiol 2001;37:202530.
The equation on page 2027 is incorrect. The correct equation is as follows:
PLA = 53.236 (0.302DTD) + (0.000484(DTD2))
We regret this error.
|