Lack of improvement of lung diffusing capacity following fluid withdrawal by ultrafiltration in chronic heart failure
PierGiuseppe Agostoni, MD, PhDa,
Marco Guazzi, MD, PhD, FACCa,
Maurizio Bussotti, MDa,
Marco Grazi, MDa,
Pietro Palermo, MDa and
Giancarlo Marenzi, MDa
a Istituto di Cardiologia dellUniversità degli Studi, Centro Cardiologico IRCCS, Centro di Studio per le Ricerche Cardiovascolari del CNR, Milan, Italy
Manuscript received January 13, 2000;
revised manuscript received April 14, 2000,
accepted June 15, 2000.
Reprint requests and correspondence: Dr. PierGiuseppe Agostoni, Istituto di Cardiologia, Centro Cardiologico, Università di Milano, Via Parea 4, 20138 Milan, Italy. piergiuseppe.agostoni{at}cardiologicomonzino.it
 |
Abstract
|
|---|
OBJECTIVES
We sought to investigate the possibility that lung diffusing capacity reduction observed in chronic heart failure is reversible in the short term.
BACKGROUND
Mechanical properties of the lung usually ameliorate with antifailure treatment including drugs, ultrafiltration and heart transplantation, whereas lung diffusion rarely improves.
METHODS
We studied the mechanical properties of the lung (pulmonary function tests with determination of alveolar volume, extravascular lung fluids and lung tissue), lung diffusion for carbon monoxide (DLco), including membrane diffusing capacity (Dm), pulmonary capillary blood volume (Vc) and pulmonary hemodynamics, in 28 patients with stable chronic heart failure, before a single session of extracorporeal ultrafiltration (3973 ± 2200 ml) and four days thereafter. Lung mechanics and diffusion were also evaluated in 18 normal subjects.
RESULTS
Vital capacity, forced expiratory volume (1 s) and maximal voluntary ventilation were lower in patients when compared with normal subjects, and increased after ultrafiltration from 2.1 ± 0.7 to 2.5 ± 0.7(l)*, 1.7 ± 0.5 to 2.0 ± 0.6(l)* and 67 ± 25 to 79 ± 26 (l/min)*, respectively (* p < 0.02 vs. pre-ultrafiltration). Post-ultrafiltration alveolar volume was augmented, while lung tissue, body weight ( 6 kg), chest X-ray extravascular lung water score and pulmonary vascular pressure were reduced. Heart dimensions (echocardiography) remained unchanged. DLco, Dm and Vc were 29.0 ± 5.0 ml/min/mm Hg, 47.0 ± 11.0 ml/min/mm Hg, 102 ± 20 ml in normal subjects and 17.1 ± 4.0#, 24.1 ± 6.5#, 113 ± 38 and 17.0 ± 5.0#, 24.8 ± 7.9#, 100 ± 39 in patients before and after ultrafiltration, respectively (# = p < 0.01 vs. controls).
CONCLUSIONS
In chronic heart failure, ultrafiltration improves volumes and mechanical properties of the lung by reducing lung fluids. Diffusion is unaffected by ultrafiltration, suggesting that, in chronic heart failure, the alveolar-capillary membrane abnormalities are fluid-independent.
|
Abbreviations and Acronyms
| | DLco | = lung diffusion for carbon monoxide | | Dm | = alveolar-membrane diffusing capacity | | FEV1 | = forced expiratory volume in 1 s | | MVV | = maximal voluntary ventilation | | NYHA | = New York Heart Association | | Vc | = pulmonary capillary blood volume available for gas exchange | | VC | = vital capacity |
|
In heart failure patients the mechanical properties of the lung, as well as lung diffusing capacity, are frequently altered (14), and pulmonary function tests often identify a restrictive pattern (2,4). Pulmonary mechanical abnormalities can be reduced, or even resolved, with different sorts of heart failure treatment, including drugs (57), ultrafiltration (8,9) and heart transplantation (10). On the contrary, lung diffusing capacity has been shown to improve with angiotensin-converting enzyme inhibitors (57), but not with other antifailure drugs, such as diuretics (11), AT1-blockers (6,7), hydralazine (5) and beta-blockers (12). Furthermore, heart transplantation, which is probably the most effective antifailure treatment, does not affect and may even worsen lung diffusing capacity. Data on lung diffusion after ultrafiltration are lacking (1315). Raughton and Foster (16) showed that lung diffusion can be split into two subcomponents: alveolar-capillary membrane resistance and volume of pulmonary capillary blood. Indeed, 1/DLco = 1/Dm + 1/ Vc, where DLco is lung diffusion capacity for carbon monoxide, Dm is alveolar-capillary membrane resistance, is red blood cell resistance and Vc is pulmonary capillary blood volume available for gas exchange. Dm reduces as heart failure worsens (4,17), whereas Vc increases only when heart failure is severe (17). Increased Vc is seen as a partial compensatory mechanism to alveolar capillary membrane reduction (17). Lack of improvement in lung diffusing capacity after heart transplantation (1315) suggests that normalization of pulmonary capillary blood volume, following pulmonary hemodynamic improvement, is not counterbalanced by an increase of alveolar capillary membrane diffusing capacity. This supports the concept that chronic heart-failure-induced membrane damage is, at least in part, not reversible. Mettauer et al. (18) reported a correlation between duration of heart failure and alveolar-capillary membrane conductance defects. However, several factors, beyond the duration of a hemodynamic event, might influence alveolar capillary membrane diffusing capacity after heart transplant: (a) increase of lung volume due to heart size reduction (10), (b) chest wall and chest muscle damage with surgery, and (c) use, in the postsurgical period, of drugs that might alter lung diffusion. Indeed, lung diffusion is not merely ruled by pressure gradients, but also by fluid movement across the alveolar-capillary membrane, which has a relevant active component (1921). Accordingly, a correlation between lung diffusing capacity decline, after heart transplant, and cyclosporine plasma levels was noted by Casan et al. (22).
Therefore, we decided to study the behavior of pulmonary mechanics and lung diffusing capacity in heart failure before and after a therapeutic technique that induces pulmonary hemodynamic improvement without heart volume changes, and without the confounding effects of surgery or drugs possibly interfering with lung diffusion (5,22). We aimed at knowing how much impairment is due to alveolar fluid retention and how much to nonhemodynamic and possibly nonreversible membrane damage. We used extracorporeal ultrafiltration, which is known to reduce lung water content, right atrial and pulmonary vascular pressure, and to improve patients clinical condition, which includes exercise capacity as well as pulmonary mechanical properties (8,9).
 |
Methods
|
|---|
Patient population.
We studied 28 patients with severe heart failure (New York Heart Association [NYHA] class III and IV) in stable clinical condition and therapeutic regimen. All patients belonged to a cohort of heart failure subjects regularly followed at the Heart Failure Unit of the Institute of Cardiology, University of Milan. Twenty-one patients were males and seven females (mean age 66 ± 8 years). Heart failure etiology was ischemic heart disease in 15 subjects, idiopathic cardiomyopathy in 9 and valvular heart disease in 4. Exclusion criteria were: left ventricular ejection fraction (by echocardiography) >35%, primary pulmonary disease, unstable angina or recent myocardial infarction, artificial pacemakers. Drug treatment included diuretics (28 cases), angiotensin-converting enzyme inhibitors (22 cases), digoxin (19 cases), nitrates (9 cases) and amiodarone (11 cases). Therapy remained unchanged throughout the study. Eighteen control subjects were also investigated (12 men and 6 women, mean age 61 ± 7 years) for pulmonary function test measurements. The study was approved by the local Ethical Committee and all patients provided informed written consent to the study.
Echocardiographic evaluation.
Patients underwent echocardiographic measurement of left ventricle volumes and ejection fraction.
Pulmonary function tests.
Pulmonary function tests included forced expiratory volume in 1 second (FEV1), vital capacity (VC), and maximal voluntary ventilation (MVV) measurements. For MVV we used the greater between measured MVV over 12 s and FEV1 x 40 (23). Alveolar volume was obtained by methane dilution technique. We also determined DLco using the single breath constant expiratory flow technique. DLco measurement was corrected for the subjects hemoglobin concentration, according to Coats et al. (24). We also measured the DLco subcomponents Dm and Vc (16). Lung tissue was calculated by applying the Wilson formula, which considers the decay of methane, carbon monoxide and acetylene during constant expiratory flow (2527).
Chest X-ray.
Extravascular lung fluid content was assessed with a radiographic score (28).
Hemodynamic evaluation.
Hemodynamic evaluation was carried out using Swan-Ganz catheterization of the pulmonary artery (internal jugular vein approach). We measured pulmonary artery pressure, pulmonary wedge pressure, right atrial pressure and cardiac output (thermodilution, triplicate measures) after at least 30 min of complete rest.
Ultrafiltration.
A single session of ultrafiltration was performed using a previously described technique (8,9). In brief, a diafilter (D20SF Amicon) was inserted into a veno-venous extracorporeal circuit that was connected to a femoral vein through a percutaneous double-lumen Y-shaped catheter for blood withdrawal and reinfusion. Patients were treated with IV heparin. Blood was propelled by a peristaltic pump. Ultrafiltration was interrupted when right atrial pressure was reduced by 50% or red pack cell volume increased by three points.
Study design.
Patients were admitted to the hospital and their clinical condition, including stability, was assessed. Thereafter, they underwent echocardiogram, chest X-ray, pulmonary function tests, lung tissue and DLco measurements, including Dm and Vc (day 1). The next day, the first hemodynamic study was performed and was followed by a single-session ultrafiltration (day 0). Four days after, clinical evaluation, hemodynamic measurements, echocardiogram, chest X-ray and the pulmonary function tests were repeated. Normal subjects underwent only pulmonary function tests.
Statistical analysis.
Data are reported as mean ± 1 standard deviation. Comparisons were made by paired or unpaired t tests as, appropriate. When needed, because of multiple comparisons, the Bonferroni correction was applied. A value of p < 0.05 was considered statistically significant.
 |
Results
|
|---|
Ultrafiltration was safely carried out in all patients without untoward effects. The ultrafiltrate amount was 3,973 ± 2,200 ml and ranged from 1,050 to 11,000 ml. Mean body weight was 77.2 ± 13.5 kg before ultrafiltration and 71.4 ± 12.7 kg four days after the procedure (p < 0.001). At the fourth day after ultrafiltration patients clinical conditions improved and NYHA functional class reduced from 3.6 ± 0.6 to 2.8 ± 0.6 (p < 0.01). Before ultrafiltration, left ventricular ejection fraction and systolic and diastolic diameters were 25.4 ± 4.3%, 54 ± 7 mm and 65 ± 8 mm, respectively, and remained unchanged four days after the procedure. Standard pulmonary function tests are reported in Table 1. An improvement in lung mechanics in all subjects was observed after ultrafiltration. In contrast, DLco, which was significantly reduced in patients compared to normal subjects, did not increase after ultrafiltration. Lack of variations in DLco was the result of an unchanged Dm with a tendency of Vc to decrease (Table 2). Patients alveolar volume was significantly lower than normal subjects and increased by 10% four days after ultrafiltration. DLco, normalized for alveolar volume, decreased after the procedure, while Dm remained unchanged. Lung tissue was increased in patients with heart failure when compared with normal subjects by 50% and, four days after ultrafiltration, reduced from 620 ± 180 ml to 550 ± 170 ml (p < 0.02). Considering the short time interval, this reduction was likely due to a decrease in lung water content. Accordingly, chest X-ray extravascular lung water score reduced from 18.4 ± 3.5 to 11.2 ± 3.0 (p < 0.01). Hemodynamic parameters before and after ultrafiltration are reported in Table 3.
View this table:
[in this window]
[in a new window]
|
Table 1 Standard Pulmonary Function Tests in Controls (n = 18) and in Chronic Congestive Heart Failure Patients Undergoing Ultrafiltration (n = 28)
|
|
View this table:
[in this window]
[in a new window]
|
Table 2 Lung Diffusing Capacity for Carbon Monoxide (DLco), Alveolar-Capillary Membrane Diffusing Capacity for Carbon Monoxide (Dm), Capillary Volume (Vc), Alveolar Volume (Va) and Lung Tissue (Lt) in Controls (n = 18) and in Chronic Congestive Heart Failure Patients Undergoing Ultrafiltration (n = 28)
|
|
View this table:
[in this window]
[in a new window]
|
Table 3 Pulmonary Hemodynamics in 28 Chronic Congestive Heart Failure Patients Before Ultrafiltration and Four Days Thereafter
|
|
 |
Discussion
|
|---|
The major result of the present study is that, in patients with chronic congestive heart failure, mechanical properties and diffusing capacity of the lung behave differently after reduction of lung fluid content, right atrial and pulmonary venous pressures by ultrafiltration. Amelioration of mechanical properties of the lung after ultrafiltration is due to reduction of lung stiffness secondary to a lowered lung fluid content (8,29). The factors that, in chronic heart failure, determine low lung diffusing capacity are the reduction of gas surface exchange and the impairment of membrane diffusing capacity. The former is inferable from reduction of vital capacity and alveolar volume, the latter from a low Dm. Lack of Dm improvement, as well that of Dm normalized for alveolar volume after the procedure, suggests that increase in the fluid content of the alveolar capillary membrane is not the major cause of lung diffusing capacity reduction. On the other hand, membrane impairment may be due to an increase in cellularity and fibrosis. Therefore, our findings explain why Dm changes may be irreversible and not influenced by heart transplantation (13,14,18).
Ultrafiltration was safely conducted in all subjects and, as demonstrated by NYHA functional class reduction, allowed improvement of the patients clinical condition. The present report, however, is not intended to document the safety of ultrafiltration or its clinical efficacy, which have been previously reported in several papers (8,9,2932). In this study, we utilized data on lung function, from patients with severe heart failure who are undergoing ultrafiltration for clinical reasons, in order to better understand the differences in the response of lung mechanics and diffusing capacity to heart failure treatment. Remarkably, ultrafiltration has been shown to reduce lung fluid content and, as a consequence, to improve lung mechanics (29) without changing heart dimensions (31), with no surgical trauma on the chest and without utilization of drugs possibly interfering with lung diffusing properties (22). The greater reduction in body weight four days after ultrafiltration, compared to the ultrafiltrate volume (5.8 ± 3.7 Kg vs. 3973 ± 2205 ml), is not surprising in view of the ultrafiltration capability to restore diuresis and kidney response to diuretics (32).
Vital capacity and lung tissue are inversely related to each other in relation to the amount of interstitial fluids. Both showed, before and after ultrafiltration, a significant intersubject variability in patients compared with normal subjects (Tables 1 and 2). This variability may depend on individual differences in intravascular pressures, on lung fluid drainage capacity due to the unevenly enhanced fluid removal capacity of various lung fluid drainage pathways in chronic heart failure (33,34) and on heart dimension (cardiomegaly), a major cause of lung restrictive disease in heart failure (10). Accordingly, it has been shown for many years that pulmonary wedge pressure can be predicted by chest X-ray, in acute but not in chronic heart failure, when the above reported mechanisms interplay (35). However, increase of vital capacity and reduction of lung tissue observed after ultrafiltration are as one would expect after acute lung fluid reduction. A reduction in lung fluid is suggested by lower right atrial and pulmonary wedge pressures and X-ray extravascular lung score observed four days after ultrafiltration.
In chronic heart failure, DLco is impeded mainly because Dm is reduced (17). In the present study, both overall Dm and Dm normalized for alveolar volume were low and, more importantly, remained unchanged after ultrafiltration. Because ultrafiltration reduced lung fluid, an increase in Dm would be expected if augmented lung fluid were the cause of the reduced Dm. Actually, we cannot exclude the possibility that fluid movement from the alveolar-capillary membrane is a very slow process. However, this seems unlikely because, for geometrical reasons, the gas exchange surface is highly protected by fluid overload (36) and, in all likelihood, is the first site to be fluid-free when lung fluids are reduced. Furthermore, our post-ultrafiltration study was carried out four days after the procedure, an interval that is more than enough to readjust fluid distribution in the lungs. On the other hand, while ultrafiltration-induced effects on pulmonary hemodynamics and lung fluid were appreciable, Dm remained unchanged. This suggests that, in chronic congestive heart failure, Dm reduction is not likely due to fluid accumulation but to other causes, such as fibrosis or an increase in cellularity of the alveolar-capillary membrane. This finding explains why mechanical properties and diffusing capacity of the lung behave differently after heart failure treatment, which includes drugs and heart transplantation. Furthermore, the findings of the present study are in agreement with the recently developed concept that fluid transport across the alveolar-capillary membrane is, at least in part, an active (pump-mediated) phenomenon (1921) and that some antifailure drugs may act directly on the membrane diffusing activity (5).
 |
Footnotes
|
|---|
Funded by research grants from the Istituto di Cardiologia, Centro Cardiologico, IRCCS, Università di Milano and Centro di Studio per le Ricerche Cardiovascolari del CNR.
 |
References
|
|---|
1. Snashall PD, Chung KF. Airway obstruction and bronchial hyperresponsiveness in left ventricular failure and mitral stenosis. Am Rev Respir Dis. 1991;144:945956[Medline]
2. Naum CC, Sciurba FC, Rogers RM. Pulmonary function abnormalities in chronic severe cardiomyopathy preceding cardiac transplantation. Am Rev Respir Dis. 1992;145:13341338[Medline]
3. Wright RS, Levine MS, Bellamy PE, et al. Ventilatory and diffusion abnormalities in potential heart transplant recipients. Chest. 1990;98:816820[Abstract/Free Full Text]
4. Chua TP, Coats AJS. The lungs in chronic heart failure. Eur Heart J. 1995;16:882887[Free Full Text]
5. Guazzi M, Marenzi GC, Alimento M, Contini M, Agostoni PG. Improvement of alveolar capillary membrane diffusing capacity with enalapril in chronic heart failure and counteracting effect of aspirin. Circulation. 1997;95:19301936[Abstract/Free Full Text]
6. Guazzi M, Melzi G, Agostoni PG. Comparison of change in respiratory function and exercise oxygen uptake with losartan vs. enalapril in congestive heart failure secondary to ischemic or idiopathic cardiomyopathy. Am J Cardiol. 1997;80:15721576[CrossRef][Medline]
7. Guazzi M, Palermo P, Pontone G, Susini F, Agostoni PG. Synergistic efficacy of enalapril and losartan on exercise performance and oxygen consumption at peak exercise in congestive heart failure. Am J Cardiol. 1999;84:10381043[CrossRef][Medline]
8. Agostoni P, Marenzi GC, Pepi M, et al. Isolated ultrafiltration in moderate heart failure. J Am Coll Cardiol. 1993;21:424431[Abstract]
9. Agostoni P, Marenzi G, Lauri G, et al. Sustained improvement in functional capacity after removal of body fluid with isolated ultrafiltration in chronic cardiac insufficiency. Failure of furosemide to provide the same result. Am J Med. 1994;96:191196[CrossRef][Medline]
10. Hosenpud JD, Stibolt TA, Atwal K, Shelley D. Abnormal pulmonary function specifically related to congestive heart failure: comparison of patients before and after cardiac transplantation. Am J Med. 1990;88:493496[CrossRef][Medline]
11. Hanel B, Clifford PS, Secher NH. Restricted postexercise pulmonary diffusion capacity does not impair maximal transport for O2. J Appl Physiol. 1994;77:24082412[Abstract/Free Full Text]
12. Guazzi M, Agostoni P, Matturri M, Pontone G, Guazzi MD. Pulmonary function, cardiac function, and exercise capacity in a follow-up of patients with congestive heart failure treated with carvedilol. Am Heart J. 1999;138:460467[CrossRef][Medline]
13. Ravenscraft SA, Gross CR, Kubo SH, et al. Pulmonary function after successful heart transplantation. Chest. 1993;103:5458
14. Ohar J, Osterloh J, Ahmed N, Miller L. Diffusing capacity decreases after heart transplantation. Chest. 1993;103:857861[Abstract/Free Full Text]
15. Bussières LM, Pflugfelder PW, Ahmad D, Taylor AW, Kostuk WJ. Evolution of resting lung function in the first year after cardiac transplantation. Eur Respir J. 1995;8:959962[Abstract]
16. Roughton FJW, Forster RE. Relative importance of diffusion and chemical reaction rates in determining rate of exchange of gases in the human lung, with special reference to true diffusing capacity of pulmonary membrane and volume of blood in the lung capillaries. J Appl Physiol. 1957;2:290302
17. Puri S, Baker BL, Dutka DP, Oakley CM, Hughes JMB, Cleland JGF. Reduced alveolar-capillary membrane diffusing capacity in chronic heart failure. Circulation. 1995;91:27692774[Abstract/Free Full Text]
18. Mettauer B, Lampert E, Charloux A, et al. Lung membrane diffusing capacity, heart failure, and heart transplantation. Am J Cardiol. 1999;83:6267[CrossRef][Medline]
19. Wangensteen D, Bartlett M. D- and L- glucose transport across the pulmonary epitelium. J Appl Physiol. 1984;57:17221730[Abstract/Free Full Text]
20. Chrone C, Saumon G, Basset G. News from the alveoli. News Physiol Sci. 1990;5:5053[Abstract/Free Full Text]
21. Guazzi M, Agostoni P, Bussotti M, Guazzi MD. Impeded alveolar-capillary gas transfer with saline infusion in heart failure. Hypertension. 1999;34:12021207[Abstract/Free Full Text]
22. Casan P, Sanchis J, Cladellas M, Amergual MJ, Caralps JM. Diffusing lung capacity and cyclosporine. Ann Rev Med. 1986;37:215224[CrossRef][Medline]
23. Hansen JE, Sue DY, Wasserman K. Predicted value for clinical exercise testing. Am Rev Respir Dis. 1984;129:S49S55[Medline]
24. Cotes JA, Dabbs JM, Elwood PC, Hall AM, Mc Donald A, Sauders MJ. Iron deficiency anemia: its effects on transfer factors for the lung (diffusing capacity) and ventilation and cardiac frequency during submaximal exercise. Clin Sci. 1972;42:325335[Medline]
25. Matoren TB, Wilson AF. Theoretical basis of single breath gas absorption tests. J Math Biol. 1982;14:203220[CrossRef][Medline]
26. Cander L, Forster RE. Determination of pulmonary parenchymal tissue volume and pulmonary capillary blood flow in man. J Appl Physiol. 1959;14:451551[Free Full Text]
27. Galuse FL, Wilson AF. Pulmonary parenchymal tissue volume in normal subjects. The effects of age and sex. Chest. 1977;72:207211[Abstract/Free Full Text]
28. Pistolesi M, Giuntini C. Assessment of extravascular lung water. Radiol Clin North Am. 1978;16:551574[Medline]
29. Agostoni PG, Marenzi GC, Sganzerla P, et al. Lung-heart interaction as a substrate for the improvement in exercise capacity following body fluid volume depletion in moderate heart failure. Am J Cardiol. 1995;76:793798[CrossRef][Medline]
30. Silverstein ME, Ford CA, Lysaght MJ, Henderson LW. Treatment of severe fluid overload by ultrafiltration. N Engl J Med. 1974;291:747751[Medline]
31. Pepi M, Marenzi GC, Agostoni PG, et al. Sustained cardiac diastolic changes elicited by ultrafiltration in patients with moderate congestive heart failure: pathophysiological correlates. Br Heart J. 1993;70:135140[Abstract/Free Full Text]
32. Marenzi GC, Grazi S, Giraldi F, et al. Interrelation of humoral factors, hemodynamics and fluid and salt metabolism in congestive heart failure. Am J Med. 1993;94:4956[CrossRef][Medline]
33. Matthay M. Lung and pleural fluid and protein balance. Butler J. The Bronchial Circulation. New York, Basel, Hong Kong: Marcel Dekker; 1992. p. 389415
34. Staub N. Pulmonary edema. Physiol Rev. 1974;54:678810[Free Full Text]
35. Dash H, Lipton MJ, Chatterjee K, Parmely WW. Estimation of pulmonary artery wedge pressure from chest radiography in patients with chronic congestive cardiopulmonary and ischemic cardiomyopathy. Br Heart J. 1980;44:322329[Abstract/Free Full Text]
36. Albert RK. Sites of leakage in pulmonary edema. Said SI. The Pulmonary Circulation in Acute Lung Injury. Mount Kisco, NY: Futura Publishing; 1985. p. 189207
This article has been cited by other articles:

|
 |

|
 |
 
B. A. Bart
Treatment of Congestion in Congestive Heart Failure: Ultrafiltration Is the Only Rational Initial Treatment of Volume Overload in Decompensated Heart Failure
Circ Heart Fail,
September 1, 2009;
2(5):
499 - 504.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Pecchiari, T. Anagnostakos, E. D'Angelo, C. Roussos, S. Nanas, and A. Koutsoukou
Effect of heliox breathing on flow limitation in chronic heart failure patients
Eur. Respir. J.,
June 1, 2009;
33(6):
1367 - 1373.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Magri, M. Brioschi, C. Banfi, J. P. Schmid, P. Palermo, M. Contini, A. Apostolo, M. Bussotti, E. Tremoli, S. Sciomer, et al.
Circulating Plasma Surfactant Protein Type B as Biological Marker of Alveolar-Capillary Barrier Damage in Chronic Heart Failure
Circ Heart Fail,
May 1, 2009;
2(3):
175 - 180.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. Agostoni, M. Bussotti, G. Cattadori, E. Margutti, M. Contini, M. Muratori, G. Marenzi, and C. Fiorentini
Gas diffusion and alveolar-capillary unit in chronic heart failure
Eur. Heart J.,
November 1, 2006;
27(21):
2538 - 2543.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. F. Voelkel, R. A. Quaife, L. A. Leinwand, R. J. Barst, M. D. McGoon, D. R. Meldrum, J. Dupuis, C. S. Long, L. J. Rubin, F. W. Smart, et al.
Right Ventricular Function and Failure: Report of a National Heart, Lung, and Blood Institute Working Group on Cellular and Molecular Mechanisms of Right Heart Failure
Circulation,
October 24, 2006;
114(17):
1883 - 1891.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Guazzi, G. Reina, G. Tumminello, and M. D. Guazzi
Alveolar-capillary membrane conductance is the best pulmonary function correlate of exercise ventilation efficiency in heart failure patients
Eur J Heart Fail,
October 1, 2005;
7(6):
1017 - 1022.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. Agostoni, A. Magini, D. Andreini, M. Contini, A. Apostolo, M. Bussotti, G. Cattadori, and P. Palermo
Spironolactone improves lung diffusion in chronic heart failure
Eur. Heart J.,
January 2, 2005;
26(2):
159 - 164.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. T. Robertson, R. Pellegrino, D. Pini, J. Oreglia, S. DeVita, V. Brusasco, and P. Agostoni
Exercise response after rapid intravenous infusion of saline in healthy humans
J Appl Physiol,
August 1, 2004;
97(2):
697 - 703.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Bussotti, D. Andreini, and P. Agostoni
Exercise-induced changes in exhaled nitric oxide in heart failure
Eur J Heart Fail,
August 1, 2004;
6(5):
551 - 554.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Guazzi
Alveolar-Capillary Membrane Dysfunction in Heart Failure: Evidence of a Pathophysiologic Role
Chest,
September 1, 2003;
124(3):
1090 - 1102.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M Guazzi, G Pontone, R Brambilla, P Agostoni, and G Reina
Alveolar-capillary membrane gas conductance: a novel prognostic indicator in chronic heart failure
Eur. Heart J.,
March 2, 2002;
23(6):
467 - 476.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Marenzi, G. Lauri, M. Grazi, E. Assanelli, J. Campodonico, and P. Agostoni
Circulatory response to fluid overload removal by extracorporeal ultrafiltration in refractory congestive heart failure
J. Am. Coll. Cardiol.,
October 1, 2001;
38(4):
963 - 968.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|