JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 2000; 35:1485-1492
© 2000 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Narayan, S. M.
Right arrow Articles by Smith, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Narayan, S. M.
Right arrow Articles by Smith, J. M.

CLINICAL STUDIES

Exploiting rate-related hysteresis in repolarization alternans to improve risk stratification for ventricular tachycardia

Sanjiv M. Narayan, MB, MD, MRCPa and Joseph M. Smith, MD, PhD, FACCa

a Division of Cardiology/Electrophysiology, Washington University School of Medicine, St. Louis, Missouri, USA

Manuscript received March 19, 1999; revised manuscript received October 20, 1999, accepted January 20, 2000.

Reprint requests and correspondence: Dr. Sanjiv M. Narayan, Division of Cardiology/Electrophysiology, Washington University School of Medicine, Box 8086, 660 South Euclid Avenue, St. Louis, Missouri 63110
snarayan{at}im.wustl.edu


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES

We sought to study the effect of heart rate acceleration and deceleration on the ability of repolarization alternans (RPA) to stratify ventricular tachycardia (VT) risk.

BACKGROUND

Heart rate fluctuations alter arrhythmic propensity, yet it is unclear whether fluctuations, as well as absolute rate, dynamically increase VT risk. We hypothesized that repolarization heterogeneity reflected by RPA would exhibit hysteresis during rising and falling heart rate, which may reflect arrhythmic propensity.

METHODS

The RPA magnitude (absolute voltage of alternation [Valt] and T-wave alternans ratio [TWAR]) and temporal distribution were determined from the electrocardiogram (ECG) in 60 patients during paced heart rate acceleration from 100 to 150 beats/min, then deceleration to 100 beats/min at electrophysiologic study (EPS). The Valt and TWAR thresholds were varied prospectively to generate receiver-operating characteristics (ROC) for the prediction of inducible VT at EPS.

RESULTS

Thirty-six patients were induced into VT and 24 were not. Hysteresis of RPA was seen. The Valt reached steady-state within 60 beats of each rate transition and was higher in deceleration than in acceleration at matched heart rates. In induced patients, Valt rose then fell with heart rate. In noninduced patients, Valt was insensitive to acceleration, but rose on initial deceleration. The RPA distributed later within repolarization in induced patients but, on deceleration, moved earlier in both groups. By ROC analysis, Valt = 2.6 µV in late repolarization at 120 beats/min provided optimal sensitivity and specificity for VT in acceleration (87.5% and 88.7%, respectively) versus deceleration (80% and 62.5%, respectively; p = 0.004, chi-square test).

CONCLUSIONS

1) Physiologic fluctuations in heart rate may affect the clinical utility of RPA for VT risk stratification; and 2) repolarization dispersion measured by RPA is more exaggerated during deceleration than acceleration at matched heart rates (rate hysteresis).

Abbreviations and Acronyms
  APD = action potential duration
  CL = cycle length
  DI = diastolic interval
  EPS = electrophysiologic study
  PES = programmed electrical stimulation (of the ventricle)
  ROC = receiver-operating characteristics
  RPA = repolarization alternans
  TWAR = T-wave alternans ratio
  VT = ventricular tachycardia
  Valt = absolute voltage of alternation (in µV)


Sudden cardiac death predominantly follows ventricular tachycardia (VT) and ventricular fibrillation (1) and affects one or two individuals per thousand in the United States annually (2). Ventricular arrhythmias themselves are sensitive to heart rate and may be precipitated by tachycardia (3), bradycardia (particularly in the long QT syndrome [4]) or fast–slow heart rate sequences (5). However, the manner in which such heart rate fluctuations modulate underlying arrhythmic substrates, such as the dispersion of repolarization, remains unclear.

We sought to determine whether dispersion of ventricular repolarization, as measured by the magnitude and temporal distribution of repolarization alternans (RPA), is affected by fluctuations in heart rate as well as absolute rate, and how this dynamic behavior relates to the inducibility of VT. Repolarization alternans represents microvolt-level, alternate-beat fluctuations in the electrocardiographic (ECG) JT segment, and these fluctuations have been shown to reflect temporospatial dispersion of repolarization in several experimental models (6–8) and to predict ventricular arrhythmias (9,10). Heart rate acceleration (11–13) and deceleration (12,14) may both exaggerate repolarization dispersion. During acceleration, RPA increases with repolarization dispersion to the point of onset of ventricular arrhythmias (7,9). However, this link is less clear during deceleration. Furthermore, the arrhythmic significance of repolarization dispersion varies with its timing within repolarization. Dispersion late, versus early, in repolarization may reflect a transmural repolarization gradient critical to re-entrant arrhythmogenesis (15), explaining the improved specificity for VT reported for RPA (16) and QT dispersion (17,18) measured in late repolarization. However, whether acceleration and deceleration may differentially alter the timing of repolarization dispersion or alter its association with VT has yet to be explored.

We hypothesized that progressive changes in heart rate may produce hysteresis in RPA, with higher magnitudes and earlier temporal redistribution within the T wave on deceleration than on acceleration. We also sought to define the optimal heart rate dynamics for applying RPA to risk stratification for inducible VT. We tested this hypothesis in patients undergoing programmed electrical stimulation (PES) of the ventricle.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Patient recruitment and clinical ECG collection.   Studies were approved by the Human Subjects Committee of the Washington University School of Medicine. Sixty consecutive consenting patients undergoing PES for evaluation of unexplained syncope or VT were recruited (the first 40 of whom were previously studied [16]), and antiarrhythmic medications were withheld for at least two days. Patients were lightly sedated using intravenous midazolam, then 6F quadripolar catheters were placed into the right atrium and right ventricle. Before PES, experimental pacing was performed simultaneously from the atrium and ventricle to maintain a constant heart rate while preventing atrial activation from contaminating late repolarization. Pacing was performed for 2 to 5 min as tolerated, at stepped cycle lengths (CLs) of 600 to 400 to 600 ms (50-ms steps). Pacing was truncated to 2 min if automated blood pressure readings (taken after 30 to 60 s of pacing at each CL and requiring 30 s) revealed hypotension. No patient experienced angina pectoris or other symptoms during pacing. Surface ECG leads I, aVF and V1 were recorded using a 16-channel analog amplifier (Bloom & Associates, Reading, Pennsylvania) with a surface ECG bandpass of 0.04 to 100 Hz. Data were sampled at 1 kHz to 12-bit resolution using an analog-to-digital board (National Instruments, Austin, Texas), then transferred to a UNIX workstation (Sun Computer, Palo Alto, California) for off-line analysis.

Spectral computation of RPA.   Analysis was performed using a suite of graphic software written by the authors in C and Labview (National Instruments), as previously described (19). Sequences of 64 contiguous beats were selected to exclude ectopic depolarizations, fusion complexes or other spurious events that impair the computation of RPA. The temporal decay of RPA was analyzed using overlapping 64-beat sequences starting from the first then every fifth beat after the onset of each paced CL. Sequences were grouped into 1) immediate (commencing with beats 0, 5, 10 and 15); 2) early (beats 20 to 35); 3) middle (beats 40 to 55); 4) late (beats 60 to 75) and 5) steady-state (beats 80 to 95) epochs.

Beats were baseline-corrected then QRS-aligned to their maximal normalized dot products. Repolarization alternans was computed on each aligned beat array using multidimensional spectral analysis (9) over the entire JT segment (R, defined without knowledge of the clinical data), then using intervals of half its duration early (RE), middle (RM) and late (RL) within the JT segment (Figure 1, left panel). Each series was represented as a two-dimensional matrix R (n, s), where n indicates the beat number (0 ≤ n ≤ 63) and s its time sample (in milliseconds). A fast Fourier transform was used to compute power spectra columnwise across all rows (arrow-wise in Fig. 1).



View larger version (22K):
[in this window]
[in a new window]
 
Figure 1 Spectral computation of RPA. Left panel, The first two QRS-aligned and baseline-corrected beats from a series of 64 beats at 120 beats/min (500 ms CL pacing). JT alternation is computed from interbeat power spectra at successive time points within 1) the entire JT interval (R); and windows of half of this duration in 2) early (RE); 3) middle (RM); and 4) late (RL) repolarization. Right panel, Summation of spectra at each time point reveals RPA as the magnitude at 0.5 cycles/beat, {Sigma}T. {Sigma}T is related to noise (0.33 to 0.48 cycles/beat) as TWAR, where TWAR ≥3 is significant (TWAR = 67.6 here for R). The mean voltage of JT alternation was Valt = 7.67 µV.

 
The RPA is represented by the 0.5-cycles/beat peak from the summated power spectra, {Sigma} T (in µV2), distinct from respiratory modulation of the ECG (0.1 cycles/beat in Fig. 1). The RPA was quantified relative to spectral noise, defined over 10 preceding spectral points (0.33 to 0.48 cycles/beat), using the dimensionless T-wave alternans ratio (TWAR):

where TWAR >0 indicates RPA detectable above noise; TWAR ≥3 predicts inducible VT (9); and µnoise and {sigma}noise are mean and standard deviation of noise, respectively (µV2). The mean absolute voltage difference of alternation (Valt) over the series (Fig. 1A) was also estimated as:

Protocol for PES and outcome comparisons.   Programmed electrical stimulation was performed by pacing at the right ventricular apex at CL 600 then 400 ms. A train-of-eight S1 stimuli were presented, followed by single, double or triple premature extrastimuli, as required, to induce sustained monomorphic VT. If unsuccessful, this process was repeated at a second right ventricular site. Accordingly, each patient (n = 60) was labeled "inducible" or "noninducible." The RPA data for surface ECG leads I, aVF and V1 were combined into a vector resultant using Pythagoras’ theorem. For each JT region in each patient, RPA was considered significant (RPA-positive) or not (RPA-negative) according to whether TWAR and Valt exceeded discriminants varying within ranges that encompass previously applied criteria (2 ≤ TWAR ≤ 6 and 1 ≤ Valt ≤ 4 µV). These data were compared with PES outcomes to generate receiver-operating characteristic (ROC) plots of specificity versus sensitivity of Valt and TWAR for inducible VT.

Statistical analysis.   Continuous data are presented as the mean value ± SD. The unpaired two-tailed t test was used to compare TWAR and Valt between groups, applying the Bonferroni correction for multiple comparisons. The chi-square test was applied to contingency tables of sensitivity and specificity. A probability level of 5% (p < 0.05) was considered statistically significant.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Thirty-six patients were induced into VT, whereas 24 were not. Induced patients had worse systolic function and a higher incidence of structural heart disease and previous MI. Of patients with structural heart disease, there was a trend for more cases to be ischemic in the inducible group versus the noninducible group (p = 0.11, chi-square test). The demographic data of both groups are shown in Table 1.


View this table:
[in this window]
[in a new window]
 
Table 1 Clinical Demographic Data of Inducible Versus Noninducible VT

 
Magnitude of RPA and heart rate.   The magnitude of RPA was greater in inducible than in noninducible patients at all CLs (Fig. 2), with a distinct rate hysteresis in each group. In inducible patients on acceleration, mean Valt (throughout repolarization, R) increased from 3.63 ± 1.32 (n = 25) to 4.54 ± 2.14 (n = 26; p = 0.036, t test) and then to 8.03 ± 5.43 µV (n = 28; p = 0.001) at 100, 120 and 150 beats/min (CLs of 600, 500 and 400 ms, respectively). Deceleration to 120 beats/min caused a slight fall in mean Valt to 7.74 ± 4.41 µV (n = 14; p = NS), then a significant reduction to 3.49 ± 2.61 µV at 100 beats/min (n = 10; p = 0.004). Notably, RPA magnitude was significantly greater (p = 0.015) at 120 beats/min during deceleration (Valt = 7.74 ± 4.41 µV) than on acceleration (Valt = 4.54 ± 2.14 µV). Relations were similar for TWAR.



View larger version (19K):
[in this window]
[in a new window]
 
Figure 2 The Valt changes asymmetrically with heart rate acceleration then deceleration, showing hysteresis on either side of the heart rate symmetry line (400 ms CL pacing). A, Inducible patients showed significant increases in Valt as the pacing rate increased from 100 beats/min (600 ms CL) to 120 beats/min (500 ms CL) to 150 beats/min (400 ms CL) for all regions of repolarization. Valt was significantly greater during deceleration than acceleration at 120 beats/min (R; p = 0.015), with redistribution from RL toward RE and RM (RM > RL; p = 0.045). Valt resumed baseline at 100 beats/min. B, Noninducible patients showed different hysteresis without an acceleration-related increase in Valt, but then an increase on deceleration to 120 beats/min (p = 0.004) and to 100 beats/min (p = 0.049) with earlier redistribution of RPA (RM > RL, p = 0.048; RM > RE, p = 0.041).

 
In noninducible patients, Valt and TWAR (throughout repolarization, R) increased very little and nonsignificantly on acceleration from 100 beats/min (2.33 ± 1.67 µV; n = 15) to 120 beats/min (2.33 ± 3.43 µV; n = 24) to 150 beats/min (2.96 ± 2.98 µV; n = 18) during pacing (p = NS for all comparisons) (Fig. 2B). However, on deceleration to 120 beats/min, Valt increased to 6.43 ± 3.81 µV (n = 14; p = 0.004) before falling to 4.21 ± 3.02 µV at 100 beats/min (n = 14; p = 0.049 vs. 120 beats/min). The Valt was greater during deceleration than acceleration at 120 beats/min (p = 0.002) and 100 beats/min (p = 0.049), as shown in Figure 2B (comparing RPA magnitudes for matched CLs on either side of the vertical line). Similar results were found for TWAR.

Temporal decay of RPA after step changes in CL.   After CL transitions in inducible patients, RPA was maximal, then decayed over the next 60 beats (three epochs). Figure 3 shows that on acceleration to 500 ms CL, the mean TWAR fell from 34.77 (immediate) to 22.34 (early; p < 0.03, t test). Statistically, immediate TWAR exceeded that in the early (p < 0.02, Wilcoxon signed-rank) and middle (p < 0.01) phases, and exceeded the all-epoch mean (p < 0.005). Similar results were seen after deceleration for all transitions. In noninducible patients, TWAR was more uniform within sequences at each CL and did not decay after either acceleration or deceleration (e.g., decelerating to 500 ms CL; p = NS for immediate vs. early, early vs. middle and middle vs. late).



View larger version (47K):
[in this window]
[in a new window]
 
Figure 3 The RPA decays rapidly after heart rate acceleration, in this case from CL 600 to 500 ms CL (120 beats/min), with TWAR for overlapping analyses commencing with beats 0, 5, 10 and 15 (epoch 1; immediate) being significantly larger than that for epoch 2 (early; p < 0.02) or epoch 3 (middle; p < 0.01). Solid bars = inducible patients; hatched bars = noninducible patients.

 
Temporal distribution of RPA during acceleration versus deceleration.   Repolarization alternans became redistributed within repolarization with changes in heart rate. In inducible patients, the RPA magnitude rose in concert for all regions during acceleration (Fig. 2A). However, deceleration caused a redistribution in RPA from late toward early (RE) and middle (RM) repolarization. On deceleration from 150 to 120 beats/min, RL fell (Valt = 6.03 ± 1.20 µV; p = 0.007) and RE rose (Valt = 7.76 ± 1.67 µV). On further deceleration to 100 beats/min, RPA fell in all regions (RE to Valt = 7.76 ± 1.67 µV, p = 0.001; RL to Valt = 6.03 ± 1.20 µV, p = 0.003). These trends were seen in all inducible patients.

In noninducible patients, the RE, RM and RL magnitudes changed to differing extents with heart rate (Fig. 2B). The RPA was insensitive to acceleration in all regions. However, on deceleration from 150 to 120 beats/min, RE, RM and RL increased significantly in tandem (p = 0.009, p = 0.003 and p = 0.026, respectively), then, on further deceleration to 100 beats/min, reduced in tandem (p = 0.049, p = 0.050 and p = NS, respectively). There was a redistribution of RPA toward mid-repolarization, with RM being greater than RE (p = 0.041) and RL (p = 0.048) at 120 beats/min (p = 0.048).

Sensitivity and specificity of RPA in late versus whole repolarization with heart rate.   Clinical sensitivity and specificity of RPA for inducible VT varied asymmetrically with heart rate between acceleration and deceleration at matched heart rates. As shown in Table 2, for the discriminant Valt = 1.9 µV (20), the best sensitivity and specificity resulted when late RPA was examined at 120 beats/min (CL 500 ms) during acceleration versus deceleration. Similar results were found for TWAR ≥3 (9).


View this table:
[in this window]
[in a new window]
 
Table 2 Acceleration- and Deceleration-Dependent Sensitivity and Specificity of Valt ≥1.9 µV in Late Versus Throughout Repolarization for VT

 
Receiver-operating characteristics of Valt and TWAR for VT.   The ROC relation at 120 beats/min (CL 500 ms pacing) is represented in Figure 4 during (A) acceleration and (B) deceleration for Valt in the range 1 ≤ Valt ≤ 4 µV and TWAR in the range 2 ≤ 6 applied over late (RL) or the entire (R) repolarization interval.



View larger version (18K):
[in this window]
[in a new window]
 
Figure 4 Receiver-operating characteristics of Valt and TWAR (discriminant levels indicated on curves) for VT at 120 beats/min, showing markedly superior specificity of (A) acceleration over (B) deceleration. Improved specificity and specificity (curves upward and to the right) follow the use of Valt over TWAR, late over whole JT segment analysis and acceleration over deceleration sequences at 500 ms CL pacing. Similar trends were evident at other CLs.

 
The optimal discriminant in this study was Valt = 2.6 µV examined in late repolarization during acceleration, providing 85.7% sensitivity and 86.3% specificity for inducible VT (Fig. 4). The ROC plots were more favorable (curves displaced upward and to the right) for Valt versus TWAR, for late versus whole repolarization and for acceleration (Fig. 4A) versus deceleration (Fig 4B). Raising the discriminant threshold increased specificity and reduced sensitivity.


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
To our knowledge, this study is the first to examine the contributions of heart rate deceleration and acceleration, as well as absolute rate, to the repolarization dynamics that may predispose to VT. In inducible patients, repolarization dispersion measured by RPA rose and fell with heart rate, whereas in noninducible patients, RPA rose during deceleration. In both groups, RPA exhibited rate-related hysteresis of magnitude, as well as distribution within the T wave. This hysteresis significantly altered the sensitivity and specificity of RPA for VT and best separated inducible from noninducible patients when analyzed in late repolarization during heart rate acceleration to 120 beats/min.

Pathophysiologic bases of RPA.   The term "repolarization alternans" acknowledges that alternation may be seen in the ST segment (9,10), T wave and U wave (21), all of which have been included in descriptions of "T-wave" alternans. Two competing mechanisms may underly RPA, reflecting the primacy of either repolarization or conduction (9,20). First, intrinsic dispersion of refractoriness may prevent complete depolarization of myocytes with the longest recovery times or alter their action potential morphology (8), producing 2:1 depolarization. This may be facilitated by the steep restitution of ventricular myocardium, wherein small differences in the diastolic interval produce widely disparate action potential durations (APDs) (22), which has been demonstrated under nonischemic conditions. The second mechanism invokes 2:1 conduction from tissue heterogeneity—triggered or automatic mechanisms that again lead to the discordant generation of action potentials. This has been demonstrated during ischemia (23). In either case, the resulting dispersion of repolarization may result in evanescent barriers to propagation, wave front fractionation and a predisposition to re-entry (8,24). The extent to which RPA reflects different mechanisms and, therefore, different arrhythmic predispositions under ischemic (6,23) versus nonischemic (8,25) conditions remains unresolved.

Hysteresis of RPA magnitude versus heart rate differs between patient subsets.   Repolarization alternans demonstrated distinct hysteresis between patients with and those without the substrates for inducible VT.

Inducible patients
The rise and fall in RPA magnitude, in concert with heart rate, is consistent in studies of human (26) as well as hypothermic (9) and ischemic (7,11) canine ventricles and may reflect an increased dispersion of repolarization, or repolarization effects secondary to CL-related changes in activation (which follow CL alterations of 70 to 78 ms [27]). The relative contribution of these mechanisms has important implications and requires further study.

Although the RPA magnitude fell on rate deceleration, it remained significantly higher on acceleration at matched heart rates (120 beats/min) (p = 0.018 for Valt). This may represent persistence from intervening shorter CL pacing (13) or the actual deceleration process; our analyses suggest that this effect dissipates before steady-state (60 beats; Fig. 3). Deceleration-related alternans in these patients may reflect restitution, wherein APD lengthening from deceleration causes a shorter diastolic interval (DI, phase 4 duration), resulting in a reciprocally shorter DI and APD in the next beat, and so on (28).

Noninducible patients
The RPA hysteresis in noninducible patients was quite different from that in inducible patients. First, RPA at a steady-state rate was insensitive to heart rate acceleration (as noted previously [16,26]), which may, speculatively, reflect a less easily perturbed physiologic dispersion of repolarization. Second, deceleration from 150 to 120 beats/min markedly increased the RPA magnitude (p = 0.004 for Valt) (Fig. 2B). Clearly, this RPA augmentation directly follows deceleration. Such deceleration-induced alternans has been reported in APD (in similar patients [12]) and in the refractory period (in canine hearts [14]). Prolonging a single cycle (a postmature stimulus) can also induce alternans in APD (in canine [29] and feline [25] myocytes) and in the refractory period (in canine hearts [29]). Conduction alterations may contribute less to RPA in deceleration, because QRS morphology is less sensitive to CL lengthening than shortening (27). Furthermore, the observation that RPA was augmented to a lesser extent immediately after abrupt CL changes hints that restitution kinetics may be less operative in noninducible patients.

Redistribution of RPA within the T wave.   Repolarization alternans became dynamically redistributed from late to early repolarization with heart rate deceleration in both patient groups (Fig. 2). Because RPA was markedly less specific for VT during deceleration (Fig. 4), such dispersion of early repolarization may be less indicative of arrhythmic substrates. Studies have recently emphasized the late T wave in re-entrant arrhythmogenesis, representing, as it does, a transmural gradient between full repolarization of the epicardium (T-wave peak), M cells (T-wave offset) and endocardium (T-wave descent) (15,30). This explains recent reports of a relationship between late QT dispersion, post–myocardial infarction survival (18) and arrhythmic tendency (in the rabbit heart [17]), and between late RPA and VT (16). In contrast, the significance of early RPA remains unclear. Under ischemic conditions, alternans in early repolarization (ST segment) may portend ventricular fibrillation (7,31,32). However, our study patients did not exhibit active ischemia, and early RPA predominated in noninducible patients (see Fig. 2 and our previous observations [16]), in whom subclinical ischemia would be particularly unlikely (Table 1).

Implications for VT risk stratification.   This study demonstrates that RPA is sensitive to heart rate and its preceding rate dynamics, both of which significantly alter its sensitivity and specificity for VT. The optimal discriminant in our study was Valt ≥2.6 µV measured in late repolarization after acceleration to a paced heart rate of 120 beats/min, providing a sensitivity of 85.7% and a specificity of 86.3% for inducible VT. However, Bayesian principles require that risk-screening algorithms be tailored to pretest likelihood. Therefore, in lower risk populations, a more specific discriminant (a higher level of Valt) may be required to minimize the detection of false positive results (Fig. 4A).

Although the patients in this study differ from those comprising a typical screening population, our findings may extend previously described RPA discriminants for VT risk stratification. The earliest clinical RPA studies (9,10) suggest that TWAR ≥2.5 to 3.0 effectively separated patients with and those without VT. However, the TWAR calculation is greatly influenced by spectral noise, explaining the enhanced ROC of Valt versus TWAR in our study (Fig. 4). Recent reports using Valt ≥1.9 µV and TWAR ≥2.5 (sequences ≥1 min duration; heart rate ≥110 beats/min [20]) have not examined alternative discriminants and may not be optimal.

More fundamentally, however, rate threshold criteria effectively ignore the very heart rate variations that so significantly affect the predictive value of RPA for VT at any heart rate. From this study of repolarization dynamics, fixed-rate pacing during progressive acceleration may provide one strategy for better applying RPA to detect the substrates for VT. Studies of this nature may effectively calibrate the effects of rate fluctuations on RPA magnitude, thereby enhancing the interpretation of RPA measured during physiologic nonfixed heart rates.

Study limitations.   Our use of simultaneous atrial and ventricular pacing precludes direct comparisons with studies by other investigators. Ventricular pacing may permit ventricular repolarization to be examined in isolation from the distinct response of Purkinje cells (13), whereas simultaneous atrial pacing permits the analysis of late repolarization, which may otherwise be distorted by atrial activity that may be dissociated or even cause artifactual alternans through retrograde conduction (33).

A notable issue relates to whether RPA co-migrates with other cardiac pathologic mechanisms, and therefore whether the mechanisms underlying RPA may vary as a function of substrate. Inducible patients in our study had worse cardiac systolic function and a higher incidence of previous myocardial infarction than did noninducible patients (Table 1). Although one previous study failed to correlate RPA with the presence of organic heart disease (10), structural disease can theoretically contribute to ventricular arrhythmias through infarct-related scar, repolarization effects of myocardial stretch (34) or slippage (35) and neurohumoral effects (7). The direct impact of myocardial pathology on RPA is being explored further in large observational studies currently under way (36).

Finally, we acknowledge that this is a small study, and its conclusions must be considered in this perspective. Additional studies in larger patient populations are required to validate our results.

Conclusions.   The magnitude and temporal distribution of repolarization dispersion are sensitive to the direction of heart rate change as well as to absolute rate. Deceleration-related repolarization heterogeneity is timed earlier within repolarization, which may explain its less clear association with VT, as compared with acceleration-related changes. In this group, optimal separation of inducible from noninducible patients was found for Valt ≥2.6 µV in late repolarization during acceleration to 120 beats/min.


    Acknowledgments
 
We thank Drs. Mitchell N. Faddis, Marye J. Gleva and Bruce D. Lindsay for their help in facilitating recordings for these studies, Mr. Ethan J. Korngold for his help in data analysis, and Dr. Benico Barzilai for reviewing the manuscript.


    Footnotes
 
This work was supported by Washington University research funds.


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 

  1. Bayes de Luna A, Coumel P, Leclerq JF. Ambulatory sudden cardiac death: mechanisms of production of fatal arrhythmia on the basis of data from 157 cases. Am Heart J. 1989;117:151–159[CrossRef][Medline]
  2. Kligfield P, Levy D, Devereaux RB, Savage DD. Arrhythmias and sudden death in mitral valve prolapse. Am Heart J. 1987;113:1298–1307[CrossRef][Medline]
  3. Brugada P, Green M, Abdollah H, Wellens HJJ. Significance of ventricular arrhythmias initiated by programmed ventricular stimulation: the importance of the type of ventricular arrhythmia induced and the number of premature stimuli required. Circulation. 1984;69:87–92[Abstract/Free Full Text]
  4. Priori SG, Barhanin J, Hauer RNW, et al. Genetic and molecular basis of cardiac arrhythmias: impact on clinical management—parts I and II. Circulation. 1999;99:518–528[Abstract/Free Full Text]
  5. El-Sherif N, Gough WB, Restivo M. Re-entrant ventricular arrhythmias in the late myocardial infarction period: mechanisms by which a short-long-short cardiac sequence facilitates the induction of re-entry. Circulation. 1991;83:268–278[Abstract/Free Full Text]
  6. Carson DL, Cardinal R, Savard P, Vermeulen M. Characterisation of unipolar waveform alternation in acutely ischaemic porcine myocardium. Cardiovasc Res. 1986;20:521–527[Medline]
  7. Nearing BD, Huang AH, Verrier RL. Dynamic tracking of cardiac vulnerability by complex demodulation of the T-wave. Science. 1991;252:437–440[Abstract/Free Full Text]
  8. Pastore JM, Girouard SD, Laurita KR, et al. Mechanism linking T-wave alternans to the genesis of cardiac fibrillation. Circulation. 1999;99:1385–1394[Abstract/Free Full Text]
  9. Smith JM, Clancy E, Valeri C, et al. Electrical alternans and cardiac electrical instability. Circulation. 1988;77:110–121[Abstract/Free Full Text]
  10. Rosenbaum DS, Jackson LE, Smith JM, et al. Electrical alternans and vulnerability to ventricular arrhythmias. N Engl J Med. 1994;330:235–291[Abstract/Free Full Text]
  11. Hashimoto H, Asano M, Nakashima M. Alternation in refractoriness and in conduction delay in the ischemic myocardium associated with the alternation in the ST-T complex during acute coronary occlusion in anesthetized dogs. J Electrocardiol. 1986;19:77–84[Medline]
  12. Franz MR, Swedlow CD, Liem LB, et al. Cycle length dependence of human action potential duration in vivo: effects of single extrastimuli, sudden sustained rate acceleration and deceleration, and different steady-state frequencies. J Clin Invest. 1988;82:972–979[Medline]
  13. Saitoh H, Bailey JC, Surawicz B. Alternans of action potential duration after abrupt shortening of cycle length: differences between dog Purkinje and ventricular muscle fibers. Circ Res. 1988;62:1027–1040[Abstract/Free Full Text]
  14. Janse MJ, van der Steen AB, van Dan RT. Refractory period of the dog’s ventricular myocardium following sudden changes in frequency. Circ Res. 1969;24:251–262[Abstract/Free Full Text]
  15. Yan G-X, Antzelevitch C. Cellular basis for the normal T-wave and the electrocardiographic manifestations of the long-QT syndrome. Circulation. 1998;98:1928–1936[Abstract/Free Full Text]
  16. Narayan SM, Smith JM. Differing rate dependence and temporal distribution of repolarization alternans in patients with and without ventricular tachycardia. J Cardiovasc Electrophysiol. 1999;10:61–71[Medline]
  17. Zabel M, Portnoy S, Franz MR. Electrocardiographic indexes of dispersion of ventricular repolarization: an isolated heart validation study. J Am Coll Cardiol. 1995;25:746–752[Abstract]
  18. Bruggemann T, Eisenreich S, Behrens S, et al. T-wave analysis in Holter monitoring: predictive value of repolarization in post–myocardial infarction patients. (abstr)Eur Heart J. 1996;17(Suppl):281[Abstract/Free Full Text]
  19. Narayan SM, Smith JM. Spectral analysis of periodic fluctuations in ECG repolarization. IEEE Trans Biomed Eng. 1999;46:203–212[CrossRef][Medline]
  20. Rosenbaum DS, Albrecht P, Cohen RJ. Predicting sudden cardiac death from T wave alternans of the surface electrocardiogram: promise and pitfalls. (review)J Cardiovasc Electrophysiol. 1996;7:1095–1111[Medline]
  21. Habbab MA, el-Sherif N. TU alternans, long QTU, and torsade de pointes: clinical and experimental observations. Pacing Clin Electrophysiol. 1992;15:916–931[CrossRef][Medline]
  22. Kobayashi Y, Cotoh M, Mandel WJ, Karagueuzian HS. Increased temporospatial dispersion of repolarization during double premature stimulation in the intact ventricle. Pacing Clin Electrophysiol. 1992;15:2194–2199[CrossRef][Medline]
  23. Priori SG, Mantica M, Napolitano C, Schwartz PJ. Early afterdepolarizations induced in vivo by reperfusion of ischemic myocardium. Circulation. 1990;81:1911–1920[Abstract/Free Full Text]
  24. Kuo C-S, Munakata K, Reddy CP, Surawicz B. Characteristics and possible mechanism of ventricular arrhythmia dependent on the dispersion of action potential durations. Circulation. 1983;67:1356–1367[Abstract/Free Full Text]
  25. Rubenstein DS, Lipsius SL. Premature beats elicit a phase reversal of mechanoelectrical alternans in cat ventricular myocytes: a possible mechanism for reentrant arrhythmias. Circulation. 1995;91:201–214[Abstract/Free Full Text]
  26. Kavesh NG, Shorofsky SR, Sarang SE, Gold MR. Effect of heart rate on T-wave alternans. J Cardiovasc Electrophysiol. 1998;9:703–708[Medline]
  27. Goyal R, Harvey M, Daoud EG, et al. Effect of coupling interval and pacing cycle length on morphology of paced ventricular complexes: implications for pace mapping. Circulation. 1996;94:2843–2849[Abstract/Free Full Text]
  28. Chinushi M, Restivo M, Caref EB, El-Sherif N. Electrophysiological basis of arrhythmogenicity of QT/T alternans in the long QT syndrome: tridimensional analysis of the kinetics of cardiac repolarization. Circ Res. 1998;83:614–628[Abstract/Free Full Text]
  29. Burgess M, Pollard AE, Spitzer KW, Yang L. Effects of premature beats on repolarization of postextrasystolic beats. Circulation. 1995;92:1969–1980[Abstract/Free Full Text]
  30. Lubinski A, Lewicka-Nowak E, Kempa M, et al. New insight into repolarization abnormalities in patients with congenital long QT syndrome: the increased transmural dispersion of repolarization. Pacing Clin Electrophysiol. 1998;21(Pt II):172–175[CrossRef][Medline]
  31. Konta T, Ikeda K, Yamaki M, et al. Significance of discordant ST alternans in ventricular fibrillation. Circulation. 1990;82:2185–2189[Abstract/Free Full Text]
  32. Tachibana H, Kubota I, Yamaki M, et al. Discordant S-T alternans contributes to formation of reentry—a possible mechanism of reperfusion arrhythmia. Am J Physiol. 1998;275:H116–H121
  33. Vora AM, Dalvi B, Joshi M, et al. Ventricular tachycardia with retrograde 2:1 atrial activation masquerading as T-wave alternans. Am Heart J. 1993;124:1197–1199[CrossRef]
  34. Katz AM. Cellular mechanisms in congestive heart failure. Am J Cardiol. 1988;62:3A–8A[CrossRef][Medline]
  35. Zaman AG, Morris JL, Smyllie JH, Cowan JC. Late potentials and ventricular enlargement after myocardial infarction. Circulation. 1993;88:905–914[Abstract/Free Full Text]
  36. Grimm W, Glaveris C, Hoffmann J, et al. Noninvasive arrhythmia risk stratification in idiopathic dilated cardiomyopathy—design and first results of the Marbug Cardiomyopathy Study. Pacing Clin Electrophysiol. 1998;21(Pt. 2):2551–2556[CrossRef][Medline]



This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. M. Narayan, D. D. Drinan, R. P. Lackey, and C. F. Edman
Acute volume overload elevates T-wave alternans magnitude
J Appl Physiol, April 1, 2007; 102(4): 1462 - 1468.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. M. Narayan
T-Wave Alternans and the Susceptibility to Ventricular Arrhythmias
J. Am. Coll. Cardiol., January 17, 2006; 47(2): 269 - 281.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. M. Narayan, A. Hassankhani, G. K. Feld, and V. Bhargava
Separating non-isthmus- from isthmus-dependent atrial flutter using wavefront variability
J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1269 - 1279.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. L. Walker, X. Wan, G. E. Kirsch, and D. S. Rosenbaum
Hysteresis Effect Implicates Calcium Cycling as a Mechanism of Repolarization Alternans
Circulation, November 25, 2003; 108(21): 2704 - 2709.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
M. L Walker and D. S Rosenbaum
Repolarization alternans: implications for the mechanism and prevention of sudden cardiac death
Cardiovasc Res, March 1, 2003; 57(3): 599 - 614.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. M. Narayan, F. Bode, P. L. Karasik, and M. R. Franz
Alternans of Atrial Action Potentials During Atrial Flutter as a Precursor to Atrial Fibrillation
Circulation, October 8, 2002; 106(15): 1968 - 1973.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Narayan, S. M.
Right arrow Articles by Smith, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Narayan, S. M.
Right arrow Articles by Smith, J. M.


HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK