cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1999; 34:468-475
© 1999 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Webb, J. G.
Right arrow Articles by Oesterle, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Webb, J. G.
Right arrow Articles by Oesterle, S.

CLINICAL STUDIES

Retrieval and analysis of particulate debris after saphenous vein graft intervention

John G. Webb, MD, FACC* ||,1, Ronald G. Carere, MD, FACC* ||, Renu Virmani, MD{dagger} ||, Donald Baim, MD, FACC{ddagger} ||,2, Paul S. Teirstein, MD, FACC§ ||, Patrick Whitlow, MD, FACC|| ¶, Colleen McQueen, RN|| #,2, Frank D. Kolodgie, PhD{dagger} ||, Elizabeth Buller, RN* ||, Arthur Dodek, MD, FACC* ||, G. B. John Mancini, MD, FACC** || and Stephen Oesterle, MD, FACC|| {dagger}{dagger}

* St. Paul’s Hospital, University of British Columbia, Vancouver, Canada
{dagger} Armed Forces Institute of Pathology, Washington, DC, USA
{ddagger} Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
§ Scripps Clinic, La Jolla, California, USA
|| Oschner Medical Clinic, New Orleans, Louisiana, USA
Cleveland Clinic Foundation, Cleveland, Ohio, USA
# PercuSurge, Sunnyvale, California, USA
** Vancouver Hospital and Health Sciences Centre, Vancouver, Canada
{dagger}{dagger} Stanford University Medical Center, Stanford, California, USA

Manuscript received July 14, 1998; revised manuscript received January 25, 1999, accepted April 9, 1999.

Reprint requests and correspondence: Dr. John Webb, Director of Interventional Cardiology, St. Paul’s Hospital, 502-1160 Burrard Street, Vancouver, British Columbia, Canada V6Z 2E8
johnwebb{at}bc.sympatico.ca


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES

This study was designed to evaluate the composition and quantity of particulate debris resulting from vein graft intervention.

BACKGROUND

Distal embolization and "no reflow" are frequent and important complications resulting from angioplasty of diseased saphenous vein grafts. Little is known about the composition and quantity of embolic particulate debris associated with vein graft intervention, and no intervention has been shown to protect against its clinical consequences.

METHODS

A catheter system, designed to contain, retrieve and protect against distal embolization of this material, was evaluated during 27 percutaneous interventional saphenous vein graft procedures. Clinical, angiographic and pathologic analyses were performed.

RESULTS

The duration of distal graft occlusion required to allow intervention and subsequent debris removal was 150 ± 54 s, decreasing as experience was gained. Thrombolysis in Myocardial Infarction trial (TIMI) flow grade increased from 2.6 ± 0.8 to 3.0 ± 0.0. Creatine kinase (CK) rose above normal in three patients (11.1%) exceeding 3x normal in one (3.7%) resulting in the diagnosis of non-Q-myocardial infarction. Particulate material was identified following 21 of 23 procedures suitable for analysis. Particle size was 204 ± 57 µm in the major axis and 83 ± 22 µm in the minor axis. Particles consisted predominantly of soft acellular atheromatous material, such as that typically found under a fibrous cap. Semiquantitative analysis suggested that the quantity of particulate material was less following stenting than following balloon dilation.

CONCLUSIONS

Particulate matter is commonly present following routine angioplasty and stenting of saphenous vein grafts. Containment, retrieval and analysis of this particulate debris are all feasible. Comparison to prior clinical experience is limited by small sample size. However, to the extent that these particles may contribute to distal embolization, no-reflow and infarction, such a system may contribute to the reduction of complications following vein graft intervention.

Abbreviations and Acronyms
  CK = creatine kinase
  ECG = electrocardiogram
  TIMI = Thrombolysis in Myocardial Infarction trial


A limitation of coronary bypass surgery has been the relatively rapid progression of atheromatous disease in aortocoronary saphenous vein grafts (1). More than one-half of such grafts have failed by 10 years, and the risk of repeat surgery is significantly greater than that of the initial procedure (2,3).

Interventional management of saphenous vein graft disease is limited by distal embolization (4,5) and "no-reflow" (6–10), which may arise from disruption of soft, friable atherosclerotic plaque and adherent thrombus (11,12). The reported incidence of distal embolization following balloon angioplasty ranges from 2% to 42%, contributing to substantial morbidity (4,6,13–17). Recognized predictors of distal embolization and infarction include the presence of diffuse disease, plaque volume, and thrombus (17). Little information is available about the composition of this particulate material, and no method has been shown to prevent distal embolization. We describe a catheter system designed to contain and retrieve this particulate material, the clinical and angiographic outcome following application of this system and analysis of the composition of this particulate material.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Experimental protocol.   Between July 1997 and April 1998, a total of 22 consecutive eligible patients underwent 27 vein graft angioplasty procedures utilizing a device (PercuSurge, Sunnyvale, California) designed to contain and retrieve potentially embolic particulate material. Patients were considered eligible if they were between 35 and 85 years of age with evidence of ischemia and had a >70% diameter stenosis <30 mm in length, with TIMI flow grade ≥1 in a saphenous vein graft 3.5 to 5 mm in diameter. Exclusion criteria included myocardial infarction <72 h before the procedure, uncontrolled heart failure, cardiogenic shock, coagulation disorders or a contraindication to heparin. Informed consent was obtained, and the protocol was approved by the appropriate investigational review committees.

Device description.   The particulate containment and retrieval system consists of several components, as shown in Figure 1. The 210-cm angioplasty wire is constructed of 0.014 in. nitinol hypotube with a 35-mm radiopaque, shapeable, steerable tip. Incorporated in the distal wire is a 5.5-mm-long elastomeric balloon with a 0.41 to 0.43 in. crossing profile and available inflated diameters of 3.5 to 5.0 mm (Fig. 2). A detachable inflation adapter accesses the hypotube lumen by displacing a small seal, allowing inflation of the balloon. An aspiration catheter (Export, PercuSurge, Sunnyvale, California) with an internal lumen diameter of 0.040 in. allows removal of particulate debris before deflation of the occlusive balloon. The 135-cm-long aspiration catheter has a 35-cm-long distal monorail wire lumen and an external diameter of 0.072 in.



View larger version (29K):
[in this window]
[in a new window]
 
Figure 1 Schematic of the particulate retrieval system.

 


View larger version (69K):
[in this window]
[in a new window]
 
Figure 2 Photograph of distal occlusion balloon and aspiration catheter.

 
The occlusion balloon was advanced through the graft and distal to the stenosis. The inflation adapter was temporarily attached and the distal occlusion balloon inflated. Following removal of the inflation adapter, intervention was performed in a standard manner utilizing the hypotube as the angioplasty guide wire (Fig. 3). After removal of the interventional device, the aspiration catheter was advanced over the wire to the occlusion balloon. A 20-ml locking syringe was attached to the aspiration catheter to generate a vacuum and to serve as the collection chamber. Following manual aspiration, the inflation adapter was again attached and the distal occlusion balloon deflated, thus allowing coronary flow to resume.



View larger version (47K):
[in this window]
[in a new window]
 
Figure 3 Diagrammatic representation of the mechanism of particulate containment and retrieval.

 
Angioplasty procedure.   Angioplasty was performed utilizing 8F guides with an internal lumen of 0.086 in. and monorail balloon catheters (Boston Scientific, Galway, Ireland). Initial patients underwent balloon predilation prior to stent deployment. Subsequent patients later underwent primary stenting without predilation. Nir (Boston Scientific, Jerusalem, Israel), biliary Palmaz-Schatz (Johnson & Johnson Interventional Systems, Warren, New Jersey), Multilink (Guidant, Temecula, California), and BeStent (Medtronic Instent, Haifa, Israel) stents measuring 9 mm to 35 mm in length were implanted. Stents were dilated utilizing the initial deployment balloon inflated to at least 12 atmospheres with a goal balloon-to-reference segment ratio of >1.1:1.

Patients were pretreated with aspirin 325 mg daily. Ticlopidine 500 mg daily was initiated following the procedure and continued for two weeks. Heparin was administered to achieve an activated clotting time exceeding 300 s and routinely discontinued immediately on completion. Abciximab was utilized in four patients. Dextran, dipyridamole, warfarin, thrombolytics, calcium channel blockade and nitroglycerin were not routinely utilized.

Angiographic assessment.   Angiograms, performed in orthogonal views at baseline and after the intervention, were quantitatively analyzed at an independent core laboratory (Vancouver General Hospital). Thrombus was judged to be present if contrast angiography demonstrated an intraluminal filling defect or an abrupt vessel cutoff. "No-reflow" was defined as a new, severe reduction in coronary flow to TIMI grade 0 or 1 not due to local thrombus, spasm or dissection, implying obstruction at the level of the distal small vessels (18). Distal embolization was diagnosed when there was a filling defect, no reflow, or an abrupt cutoff in a distal coronary artery branch.

Pathologic assessment.   Vein graft aspirate was collected in glass tubes containing EDTA-citrate buffer and transported on ice. Samples were centrifuged, the plasma removed and the pellet resuspended in incomplete Hank’s Balanced Salt Solution without calcium and magnesium. Erythrocytes were lysed with 1% saponin. The reaction was stopped by calcium gluconate, and samples were then centrifuged, resuspended and the lysis step repeated. The remaining material was fixed in 10% neutral buffered formalin or glutaraldehyde and processed for light microscopy and scanning electron microscopy.

Semiquantitative analysis was performed on 4-µm-thick paraffin-embedded sections stained with hematoxylin and eosin. Samples were considered to have maximal tissue if some atherosclerotic material was present in every high power field of the section of the precipitate, moderate if every other field showed some atherosclerotic material, and minimal when only sparse material was evident. Particle size was measured from scanning electron micrographs containing a calibrated bar. The major and minor lengths and area of each particle were determined using computer software (IP Labs, Signal Analytics, Vienna, Virginia).

Clinical outcomes.   Total creatine kinase (CK) and creatine kinase, MB fraction (CK-MB) were measured before angioplasty, 8 h, and 16 h postangioplasty. An electrocardiogram (ECG) was obtained before angioplasty, immediately following angioplasty, if chest discomfort recurred and the following morning. Myocardial infarction was defined as an elevation of CK to >3x normal associated with elevation of CK-MB (19). Q-wave infarction was diagnosed in the presence of new Q waves in two contiguous leads. Clinical follow-up was obtained prospectively, by chart review and by telephone.

Statistical analysis.   Results are reported as mean ± SEM. Comparisons between angiographic measurements were made with a paired t tests. Group comparisons were performed by factorial ANOVA (STATVIEW 4.5, Abacus Concepts, San Francisco, California) and analyzed simultaneously with post hoc testing by the Scheffé procedure. Statistical significance was defined as p < 0.05.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Between July 1997 and April 1998, a total of 27 vein graft interventions were performed utilizing an emboli containment device (Table 1). Patient age was 64 ± 10 years and graft age 8.7 ± 5 years (range 2 to 12 years). Procedure time was 65 ± 25 min and fluoroscopy time 18 ± 10 min. Distal graft occlusion averaged 150 ± 54 s, decreased as experience was gained and was well tolerated. Occlusion balloon inflation volume was 1.1 ± 0.02 ml. Mean aspirate volume was 19.1 ± 5.3 ml.


View this table:
[in this window]
[in a new window]
 
Table 1 Baseline Clinical Characteristics

 
Clinical outcome.   All 27 procedures were technically successful, as shown in Figure 4. A total of 37 lesions were treated with implantation of 36 stents. No patient developed new Q waves, required cardiac surgery, or died. Creatine kinase remained normal (<260 U/liter) following 24 of 27 procedures and rose above normal following 3 procedures (11.1%). In one of these patients (CK 492 U/liter) a large visible thrombus was dislodged prior to distal occlusion with the GuardWire (PercuSurge Inc., Sunnyvale, California). In a second patient (CK 285 U/liter) operator error resulted in premature deflation of the occlusion balloon prior to aspiration. In a third patient (CK 1201 U/liter) with a large, bulky thrombus, no-reflow was evident despite protection, presumably due to incomplete thrombus aspiration. In this patient CK exceeded 3x normal, resulting in the diagnosis of non-Q myocardial infarction (3.7%). At 6 ± 3 months, no patient had died, suffered late infarction or undergone cardiac surgery, whereas target lesion reintervention was undertaken in three patients.



View larger version (61K):
[in this window]
[in a new window]
 
Figure 4 (A) Angiogram demonstrates ulcerated stenosis in a 10-year-old graft to a circumflex coronary artery. (B) During angioplasty the occlusive distal balloon prevents graft outflow. Before deflation of the distal occlusion balloon, particulate debris is aspirated and removed. (C) The graft is widely patent with normal flow.

 
Angiographic results.   Qualitative and quantitative angiographic results are presented in Table 2. In no patient was the occlusion balloon associated with visible damage to the distal vessel. Follow-up angiography performed in nine patients at 5 ± 3 months found restenosis (stenosis >50%) in four grafts, TIMI flow grade 2.9 ± 0.4 and no evidence of new disease at the site of distal occlusion.


View this table:
[in this window]
[in a new window]
 
Table 2 Angiographic Outcome After 27 Procedures

 
Pathologic assessment.   A total of 49 aspirations were suitable for analysis. Particulate material was retrieved from 21 of 23 procedures. Light microscopy revealed that the particles consisted predominantly of necrotic core with cholesterol clefts, lipid-rich macrophages and fibrin material (Fig. 5). Fibrous caps and smooth muscle cells were identified, but these appeared relatively sparse. This suggested the material consisted primarily of the soft acellular atheromatous material typically found under the fibrous cap (Table 3). Scanning electron microscopy found a particle size of 204 ± 57 µm (range 8 to 3,427 µm) in the major axis and 83 ± 22 µm in the minor axis (Fig. 6).



View larger version (89K):
[in this window]
[in a new window]
 
Figure 5 Representative micrographs of plaque material from vein graft aspirates. (A) Fibrous cap (FC) overlying a lipid-rich necrotic core (NC) containing numerous cholesterol clefts (arrows, Movat Pentachrome, x200). (B) Section stained using the monoclonal antibody CD68/KP-1 (Dako Inc., Carpinteria, California) for recognition of resident macrophages (dark brown reaction product, x200). (C) Immunostaining of aspirate material with the antibody HHF-35 (Enzo Inc., Farmingdale, New York) for recognition of smooth muscle cells (brown reaction product); note the paucity of staining (x100). (D) Necrotic core with plaque hemorrhage (red cells and fibrin, x200). (E) Aspirate material showing strands of collagen (arrow, H&E stain, x200). (F) Lipid-rich core area with cholesterol clefts (arrows, H&E stain, x200).

 

View this table:
[in this window]
[in a new window]
 
Table 3 Semiquantitative Analysis of Plaque Material in Vein Graft Aspirates

 


View larger version (167K):
[in this window]
[in a new window]
 
Figure 6 Representative scanning electron micrographs of vein graft aspirate. (A) Shows tissue resembling a fibrous cap; the sample possibly rolled during removal or processing (scale = 20 µm). (B) Fragment of plaque material containing numerous cholesterol-laden macrophages; the rod-shaped fragment in the upper left is a cholesterol crystal (arrow, scale = 50 µm). (C) Particle showing a cluster of macrophages (scale = 10 µm). (D) Macrophages interspersed in a fragment of atherosclerotic plaque (scale = 20 µm).

 
Semiquantitative analysis of aspirates, as shown in Table 3, found both balloon angioplasty and stenting were associated with recovery of particulate debris. However, particulate material was significantly greater following balloon predilation than subsequent stenting (p = 0.43). Direct stenting without balloon predilation was associated with less particulate material than seen with balloon predilation alone and less than that associated with the combination of balloon predilation and subsequent stenting. Although suggestive, numbers were small and not statistically significant.


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Study findings and implications.   The principal finding of our study is that embolic atherothrombotic particulate matter is commonly liberated during angioplasty and stenting of saphenous vein grafts. This particulate matter may play a role in the pathogenesis of distal embolization, no-reflow and infarction following vein graft intervention.

Particulate retrieval procedure.   The GuardWire system is compatible with routine angioplasty procedures and is capable of containing and then retrieving particulate debris. Event rates, including CK elevation (11.1%) and non-Q-wave myocardial infarction (3.7%), were lower than generally reported following vein graft angioplasty without such protection (17,19–21). In no case was vessel damage seen as a result of inflation of the distal occlusive balloon, and late development of a stenosis at the site of distal occlusion was not apparent.

Ischemic times required for distal occlusion and aspiration during angioplasty were well tolerated, averaging 2.5 min. Initial patients in this series underwent a staged procedure with graft aspiration and deflation of the distal occlusion balloon following predilation and stent deployment. Because these brief periods of graft occlusion were well tolerated in early cases, a single-stage approach subsequently proved feasible and desirable.

Stenting of vein grafts.   All patients in this series underwent stent implantation. Initial studies of the Palmaz-Schatz stent in focal vein graft stenoses reported transient no-reflow in approximately 10% of procedures (22) and a 10% to 12% incidence of non-Q-wave myocardial infarction (22–26). The Saphenous Vein De Novo Trial (27) compared the Palmaz-Schatz stent to balloon angioplasty and found a trend toward less non-Q-wave infarction (2% vs. 7%, p = 0.1). In one series, the Palmaz-Schatz biliary stent was associated with distal embolization in 23% of patients and non-Q-wave infarction in 44% (28). De Jaegere (29) reported a 11% incidence of in-hospital infarction, urgent surgery or death in a group of patients primarily treated with the Wallstent. Limited experience has been reported with the Wallstent (29–31), Wiktor (32), and Gianturco-Roubin stents (33) and covered stents (34).

Cardiac enzymes.   Cardiac enzymes rise in 5% to 20% of patients following percutaneous coronary interventions in native vessels (19). The reported frequency of enzyme elevation following vein graft intervention is generally higher (17,19–21,34,35) in contrast to the 11.1% incidence of CK elevation and 3.7% incidence of non-Q-wave infarction (CK >3x normal) in this study. There is some debate as to a cause–effect relationship between elevations of CK, CK-MB, and adverse late clinical outcome (19).

Comparison to alternative strategies.   Direct aspiration has been reported of angiographically visible thrombus from vein grafts utilizing standard angioplasty guiding catheters (36–38) and specially constructed thrombo-suction devices (39,40). Experience with directional atherectomy, laser and rotablator in vein grafts has been disappointing (41–45). Transluminal extractional atherectomy (InterVentional Technologies, Bellevue, Washington) may reduce cardiac enzyme release following graft intervention; however, experience has been variable, and distal embolization remains a concern (13,46–50).

Fibrinolytic drugs have been advocated as adjuncts to vein graft intervention, and local fibrinolysis has been utilized to debulk intragraft thrombus. However, reduced embolic complications have not been demonstrated (51,52). Glycoprotein IIb/IIIa inhibition may be desirable (53,54). In the EPIC trial, abciximab was associated with a reduction in distal embolization and a nonsignificant trend (14% vs. 5%) toward reduced infarction in the subgroup of patients undergoing vein graft intervention (55). However, when results of both the EPIC and EPILOG trials were combined, no benefit was found in patients undergoing vein graft intervention (53). Although secondary platelet activation by particulate matter is possible, the large amount of particulate atheroembolic material demonstrated in our study suggests a limited role for antiplatelet therapies in the prevention of distal embolization in saphenous grafts.

Implications for stenting.   The quantity of particulate debris retrieved after balloon predilation was greater than that retrieved after subsequent stent deployment (Table 3). This supports conjecture that the screen-like configuration of stents may entrap friable material, reducing the likelihood of dislodgment and embolization (27,50). An antiembolic role for stents may have implications for optimal stent design. Greater surface coverage might be desirable for stents designed for use in vein grafts.

The quantity of particulate matter retrieved in patients who underwent balloon predilation and subsequent stenting may be greater than that retrieved in patients undergoing direct stenting without predilation. This finding suggests that balloon predilation before stenting may increase embolic debris (50) and that direct stent implantation without predilation may be desirable where possible. However, all interventions were associated with the recovery of particulate debris.

Study limitations.   This single-center study is limited by small size, by limited angiographic follow-up, semi-quantitative analysis of particulate material and the lack of a randomized control group. Comparison with prior studies must be made with caution. The possibility that some of the aspirated debris might have been removed directly from the graft wall, as opposed to the lumen, cannot be excluded, although the direct effect of the aspiration catheter on the vein graft wall would be comparable to passage of other catheters commonly used during coronary interventions. There remains the potential risk for graft embolization during passage of the device before distal occlusion or to incomplete removal of debris. Further clinical trials will require direct comparison with routine vein graft intervention.

Finally, embolic atherothrombotic particulate matter is commonly present within saphenous vein grafts following routine angioplasty and stenting. Containment and retrieval of embolic particulate matter is feasible, and further trials of protection devices appear warranted. This particulate matter may play a role in the pathogenesis of distal embolization, no-reflow and infarction following vein graft intervention.


    Footnotes
 
This study was funded by the St. Paul’s Hospital Cardiology Research Fund and by PercuSurge, Sunnyvale, California.

1 Drs. Baim and Webb have, in the past, acted as consultants to the manufacturer of the device utilized in this study. Back

2 Colleen McQueen, RN, is an employee of the manufacturer of the device utilized in this study. Back


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 

  1. Bourassa M, Fisher L, Campeau L, Gillespi M, McConey M, Lesperance J. Long-term fate of bypass grafts: the Coronary Artery Surgery Study (CASS) and Montreal Heart Institute experiences. Circulation. 1985;72:V71–V77
  2. Campeau L, Enjalbert M, Lesperance J, et al. The relation of risk factors to the development of atherosclerosis in saphenous vein bypass grafts and the progression of disease in the native circulation. N Engl J Med. 1984;311:1329–1332[Abstract]
  3. Hamm C, Reimers J, Ischinger T, Rupprecht H, Berger J, Bleifeld W. A randomized study of coronary angioplasty compared with bypass surgery in patients with multivessel disease. N Engl J Med. 1994;:1037–1041
  4. Trono R, Sutton C, Hollman J, Suit P, Ratliff N. Multiple myocardial infarctions associated with atheromatous emboli after PTCA of saphenous vein grafts. Cleve Clin J Med. 1989;56:581–584[Medline]
  5. Waller B, Rothbaum D, Gorfinkel H, Ulbright T, Linnemeier T, Berger S. Morphologic observations after percutaneous transluminal balloon angioplasty of early and late aortocoronary saphenous vein grafts. J Am Coll Cardiol. 1984;4:784–792[Abstract]
  6. Kaplan B, Benzuly K, Kinn J, et al. Treatment of no-reflow in degenerated saphenous vein graft interventions: comparison of intracoronary verapamil and nitroglycerin. Cathet Cardiovasc Diagn. 1996;39:113–118[CrossRef][Medline]
  7. Baim D, Carrozza JJ. Understanding the "no-reflow" problem. Cathet Cardiovasc Diagn. 1996;1:7–8
  8. Piana R, Paik G, Moscucci M, et al. Incidence and treatment of "no-reflow" after percutaneous coronary interventions. Circulation. 1994;89:2514–2518[Abstract/Free Full Text]
  9. Abbo K, Dooris M, Glazier S, et al. Features and outcome of no-reflow after percutaneous coronary intervention. Am J Cardiol. 1995;89:778–782
  10. Morishima I, Sone T, Mokuno S, et al. Clinical significance of no-reflow phenomenon observed on angiography after successful treatment of acute myocardial infarction with percutaneous transluminal coronary angioplasty. Am Heart J. 1995;2:239–243
  11. Walts A, Fishbein M, Sustaite H, Matloff J. Ruptured atheromatous plaques in saphenous vein coronary bypass grafts: a mechanism of acute, thrombotic, late graft occlusion. Circulation. 1982;65:197–201[Abstract/Free Full Text]
  12. Mautner S, Mautner G, Hunsberger S, Roberts W. Comparison of atherosclerotic plaques in saphenous veins used as aortocoronary bypass conduits with plaques in native coronary artery in the same men. Am J Cardiol. 1992;70:1380–1387[CrossRef][Medline]
  13. Hong M, Popma J, Pichard A, et al. Clinical significance of distal embolization after transluminal extraction atherectomy in diffusely diseased saphenous vein bypass grafts. Am Heart J. 1994;127:1496–1503[CrossRef][Medline]
  14. Altmann D, Racz M, Battleman D, et al. Reduction in angioplasty complications after the introduction of coronary stents: results from a consecutive series of 2,242 patients. Am Heart J. 1996;132:503–507[CrossRef][Medline]
  15. Webb J, Myler R, Shaw R, et al. Coronary angioplasty after coronary bypass surgery: initial results and late outcome in 422 patients. J Am Coll Cardiol. 1990;116:812–820
  16. Platko W, Hollman J, Whitlow P, Franco I. Percutaneous transluminal coronary angioplasty of saphenous vein graft stenosis: long-term follow-up. J Am Coll Cardiol. 1989;14:1645–1650[Abstract]
  17. Liu M, Douglas JJ, Lembo N, et al. Angiographic predictors of a rise in serum creatine kinase (distal embolization) after balloon angioplasty of saphenous vein coronary angioplasty. Am J Cardiol. 1993;72:514–517[CrossRef][Medline]
  18. TIMI Study Group. The Thombolysis in Myocardial Infarction (TIMI) trial: phase I findings. N Engl J Med. 1995;312:932–936
  19. Califf R, Abdelmeguid A, Kuntz R, et al. Myonecrosis after revascularization procedures. J Am Coll Cardiol. 1998;31:241–251[Abstract/Free Full Text]
  20. Tardiff B, Mabe B, Wildermann N, et al. Predictors of myocardial infarction (MI) with percutaneous revascularization in a large multicenter population (abstr). J Am Coll Cardiol. 1997;88:I-277A
  21. Moscucci M, Cohen D, Kugelmass A, et al. Should small (non-Q wave) myocardial infarctions be considered "major" or "minor" complications after otherwise successful stenting or atherectomy? (abstr)Circulation. 1993;88:I-548
  22. Friedrich S, Davis S, Kuntz R, Carrozza JJ, Baim D. Investigational use of the Palmaz-Schatz biliary stent in large saphenous vein grafts. Am J Cardiol. 1993;71:439–441[CrossRef][Medline]
  23. White C, Ramee S, Collins T, Escobar A, Jain S. Placement of "biliary" stents in saphenous vein coronary bypass grafts. Cathet Cardiovasc Diagn. 1993;30:91–95[Medline]
  24. Palmaz-Schatz Stent Study GroupSavage M, Fischman D, Schatz R. Long-term angiographic and clinical outcome after implantation of balloon-expandable stents in the native coronary circulation. J Am Coll Cardiol. 1994;24:1207–1212[Abstract]
  25. Fenton S, Fischman D, Savage M, et al. Long-term angiographic and clinical outcome after implantation of balloon-expandable stents in aortocoronary saphenous vein grafts. Am J Cardiol. 1994;74:1187–1191[CrossRef][Medline]
  26. Plana R, Moscucci M, Cohen D, et al. Palmaz-Schatz stenting for treatment of focal vein graft stenosis: immediate results and long-term outcome. J Am Coll Cardiol. 1994;23:1296–1304[Abstract]
  27. Savage M, Douglas JJ, Fischman D, et al. Stent placement compared with balloon angioplasty for obstructed coronary bypass grafts. N Engl J Med. 1997;337:740–747[Abstract/Free Full Text]
  28. Kramer B. Optimal therapy for degenerated saphenous vein graft disease. J Invasive Cardiol. 1995;7:14–20
  29. de Jaegere P, van Domburg R, Feyter P, et al. Long-term clinical outcome after stent implantation in saphenous vein grafts. J Am Coll Cardiol. 1996;28:89–96[Abstract]
  30. Itoh A, Hall P, Maiello L, et al. Implantation of the peripheral Wallstent for diffuse lesions in coronary arteries and grafts. Cathet Cardiovasc Diagn. 1996;37:322–330[CrossRef][Medline]
  31. Eeckhout E, Goy J, Stauffer J, Vogt P, Kappenberger L. Endoluminal stenting of narrowed saphenous vein grafts: long-term clinical and angiographic follow-up. Cathet Cardiovasc Diagn. 1994;33:139–146[Medline]
  32. Vaishnav S, Aziz S, Layton C. Clinical experience with the Wiktor stent in native arteries and coronary bypass grafts. Br Heart J. 1994;72:288–293[Abstract/Free Full Text]
  33. Dorros G, Bates M, Iyer S, et al. The use of Gianturco-Roubin flexible metallic coronary stents in old saphenous vein grafts: in-hospital outcome and 7-day angiographic patency. Eur Heart J. 1994;11:1456–1462
  34. Reifart N, Storger H, Schwartz F, Rabe A. PTCA of degenerated vein grafts: experience of two periods (1992–3 and 1996–7) in 780 patients. Indian Heart J. 1998;50:62–66[Medline]
  35. Altmann D, Popma J, Hong M, et al. CPK-MB elevation after angioplasty of saphenous vein grafts (abstr). J Am Coll Cardiol. 1993;21:232A
  36. Cunningham J, Ling F. Transcatheter aspiration of atheroma through saphenous vein graft stents. Cathet Cardiovasc Diagn. 1996;39:258–261[CrossRef][Medline]
  37. Dooris M, Grines C. Successful reversal of cardiogenic shock precipitated by saphenous vein graft distal embolization using aspiration thrombectomy. Cathet Cardiovasc Diagn. 1994;33:267–271[Medline]
  38. Khoury A, Donohue T, Kern M. Aspiration of coronary thrombus during angioplasty for postmyocardial infarction ischemia. Cathet Cardiovasc Diagn. 1995;35:132–135[Medline]
  39. van den Boss A, van Ommen V, Corbeij H. A new thrombosuction catheter for coronary use: initial results with clinical and angiographic follow-up in seven patients. Cathet Cardiovasc Diagn. 1997;40:192–197[CrossRef][Medline]
  40. Drasler W, Jenson M, Wilson G, et al. Rheolytic catheter for percutaneous removal of thrombus. Radiology. 1992;182:263–267[Abstract/Free Full Text]
  41. Bittl J, Sanborn T, Yardley D, et al. Predictors of outcome of percutaneous excimer laser coronary angioplasty of saphenous vein bypass graft lesions: the Percutaneous Excimer Laser Coronary Angioplasty Registry. Am J Cardiol. 1994;74:144–148[CrossRef][Medline]
  42. Cowley M, DiSciascio G. Directional coronary atherectomy for saphenous vein graft disease. Cathet Cardiovasc Diagn. 1993;(Suppl 1):10–16
  43. Pomerantz R, Kuntz R, Carrozza J. Acute and long-term outcome of narrowed saphenous venous grafts treated by endo-luminal stenting and directional atherectomy. Am J Cardiol. 1992;70:161–167[CrossRef][Medline]
  44. Kaufman U, Garratt K, Vliestra R, Holmes D. Transluminal atherectomy of saphenous vein aortocoronary bypass grafts. Am J Cardiol. 1990;65:1430–1433[CrossRef][Medline]
  45. Holmes DJ, Topol E, Califf R, et al. A multicenter, randomized trial of coronary angioplasty versus directional atherectomy for patients with saphenous vein bypass grafts. Circulation. 1995;91:1966–1974[Abstract/Free Full Text]
  46. Misumi K, Matthews R, Sun G, Mayeda G, Burstein S, Shook T. Reduced distal embolization with transluminal extraction atherectomy compared with balloon angioplasty for saphenous vein graft disease. Cathet Cardiovasc Diagn. 1996;39:246–251[CrossRef][Medline]
  47. Safian R, Grines D, May M, et al. Clinical and angiographic results of transluminal extraction atherectomy in saphenous vein bypass grafts. Circulation. 1994;89:302–312[Abstract/Free Full Text]
  48. Meany T, Leon T, Kramer B, et al. Transluminal extraction catheter for the treatment of diseased saphenous vein grafts: a multicenter experience. Cathet Cardiovasc Diagn. 1995;34:112–120[Medline]
  49. Twidale N, Barth C, Kipperman R, Bowles M, Galichia J. Acute results and long-term outcome of transluminal extraction catheter atherectomy for saphenous vein graft stenoses. Cathet Cardiovasc Diagn. 1994;31:187–191[Medline]
  50. Braden G, Xenopoulos N, Young T, Utley L, Kutcher M, Applegate R. Transluminal extraction catheter atherectomy followed by immediate stenting in treatment of saphenous vein grafts. J Am Coll Cardiol. 1997;30:657–663[Abstract]
  51. Glazier J, Kiernan F, Bauer H, et al. Treatment of thrombotic saphenous vein bypass grafts using local infusion therapy with the Dispatch catheter. Cathet Cardiovasc Diagn. 1997;41:261–267[CrossRef][Medline]
  52. Hartmann J, McKeever L, Statmatao N, et al. Recanalization of chronically occluded aortocoronary saphenous vein bypass grafts with long-term, low-dose direct infusion of urokinase (ROBUST): a serial trial. J Am Coll Cardiol. 1996;27:60–66[Abstract]
  53. Tcheng J. Glycoprotein IIb/IIIa receptor inhibitors: putting the EPIC, IMPACT II, RESTORE, and EPILOG trials into perspective. Am J Cardiol. 1996;78:35–40[Medline]
  54. van de Werf F. More evidence for a beneficial effect of platelet glycoprotein IIb/IIIa blockade during coronary interventions: latest results from the EPILOG and CAPTURE trials. Eur Heart J. 1996;17:325–326[Free Full Text]
  55. Mak K, Challapalli R, Eisenberg M, et al. Effect of platelet glycoprotein IIb/IIIa receptor inhibition on distal embolization during percutaneous revascularization of aortocoronary saphenous vein grafts. Am J Cardiol. 1997;80:985–988[CrossRef][Medline]



This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
D. J. Kereiakes, M. A. Turco, J. Breall, N. Z. Farhat, R. L. Feldman, B. McLaurin, J. J. Popma, L. Mauri, P. Zimetbaum, J. Massaro, et al.
A Novel Filter-Based Distal Embolic Protection Device for Percutaneous Intervention of Saphenous Vein Graft Lesions: Results of the AMEthyst Randomized Controlled Trial
J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 248 - 257.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. A. Bittl
Damage Control for Renal Artery Stenting
Circulation, May 27, 2008; 117(21): 2724 - 2726.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Cuisset, M. Hamilos, N. Melikian, E. Wyffels, J. Sarma, G. Sarno, E. Barbato, J. Bartunek, W. Wijns, and B. De Bruyne
Direct stenting for stable angina pectoris is associated with reduced periprocedural microcirculatory injury compared with stenting after pre-dilation.
J. Am. Coll. Cardiol., March 18, 2008; 51(11): 1060 - 1065.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Coolong, D. S. Baim, R. E. Kuntz, A. J. O'Malley, S. Marulkar, D. E. Cutlip, J. J. Popma, and L. Mauri
Saphenous Vein Graft Stenting and Major Adverse Cardiac Events: A Predictive Model Derived From a Pooled Analysis of 3958 Patients
Circulation, February 12, 2008; 117(6): 790 - 797.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
J. M. Wilson and J. T. Willerson
Myocardial Revascularization with Percutaneous Devices
Card. Surg. Adult, January 1, 2008; 3(2008): 573 - 598.
[Full Text]


Home page
Eur Heart JHome page
M. Jonas, G. W. Stone, R. Mehran, J. Hermiller, R. Feldman, H. C. Herrmann, D. A. Cox, R. E. Kuntz, J. J. Popma, C. Rogers, et al.
Platelet glycoprotein IIb/IIIa receptor inhibition as adjunctive treatment during saphenous vein graft stenting: differential effects after randomization to occlusion or filter-based embolic protection
Eur. Heart J., April 2, 2006; 27(8): 920 - 928.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Herrmann
Peri-procedural myocardial injury: 2005 update
Eur. Heart J., December 1, 2005; 26(23): 2493 - 2519.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. P. Carrozza Jr, M. Mumma, J. A. Breall, A. Fernandez, E. Heyman, C. Metzger, and for the PRIDE Study Investigators
Randomized Evaluation of the TriActiv Balloon-Protection Flush and Extraction System for the Treatment of Saphenous Vein Graft Disease
J. Am. Coll. Cardiol., November 1, 2005; 46(9): 1677 - 1683.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. Mizote, Y. Ueda, T. Ohtani, M. Shimizu, Y. Takeda, T. Oka, M. Tsujimoto, A. Hirayama, M. Hori, and K. Kodama
Distal Protection Improved Reperfusion and Reduced Left Ventricular Dysfunction in Patients With Acute Myocardial Infarction Who Had Angioscopically Defined Ruptured Plaque
Circulation, August 16, 2005; 112(7): 1001 - 1007.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
N. M. Malyar, L. O. Lerman, M. Gossl, P. E. Beighley, and E. L. Ritman
Relation of Nonperfused Myocardial Volume and Surface Area to Left Ventricular Performance in Coronary Microembolization
Circulation, October 5, 2004; 110(14): 1946 - 1952.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Angelini, P. Rubartelli, F. Mistrorigo, M. Della Barbera, F. Abbadessa, M. Vischi, G. Thiene, and S. Chierchia
Distal Protection With a Filter Device During Coronary Stenting in Patients With Stable and Unstable Angina
Circulation, August 3, 2004; 110(5): 515 - 521.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Sato, H. Iida, A. Tanaka, H. Tanaka, S. Shimodouzono, E. Uchida, T. Kawarabayashi, and J. Yoshikawa
The decrease of plaque volume during percutaneous coronary intervention has a negative impact on coronary flow in acute myocardial infarction: A major role of percutaneous coronary intervention-induced embolization
J. Am. Coll. Cardiol., July 21, 2004; 44(2): 300 - 304.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. V. Kaplan, D. S. Baim, J. J. Smith, D. A. Feigal, M. Simons, D. Jefferys, T. J. Fogarty, R. E. Kuntz, and M. B. Leon
Medical Device Development: From Prototype to Regulatory Approval
Circulation, June 29, 2004; 109(25): 3068 - 3072.
[Full Text] [PDF]


Home page
CirculationHome page
C. Rogers, R. Huynh, P. A. Seifert, B. Chevalier, J. Schofer, E. R. Edelman, G. Toegel, A. Kuchela, A. Woupio, R. E. Kuntz, et al.
Embolic Protection With Filtering or Occlusion Balloons During Saphenous Vein Graft Stenting Retrieves Identical Volumes and Sizes of Particulate Debris
Circulation, April 13, 2004; 109(14): 1735 - 1740.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. E. Scoble
Do protection devices have a role in renal angioplasty and stent placement?
Nephrol. Dial. Transplant., September 1, 2003; 18(9): 1700 - 1703.
[Full Text] [PDF]


Home page
HeartHome page
G Sangiorgi and A Colombo
Embolic protection devices
Heart, September 1, 2003; 89(9): 990 - 992.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. T. Ashby, G. Dangas, E. A. Aymong, I. Iakovou, F. Kuepper, R. Mehran, G. W. Stone, M. B. Leon, and J. W. Moses
Effect of percutaneous coronary interventions for in-stent restenosis in degenerated saphenous vein grafts without distal embolic protection
J. Am. Coll. Cardiol., March 5, 2003; 41(5): 749 - 752.
[Abstract] [Full Text] [PDF]


Home page