J Am Coll Cardiol, 1999; 34:33-39 © 1999 by the American College of Cardiology Foundation |
a Medical Clinic I, RWTH University Hospital, Aachen, Germany
Manuscript received September 10, 1998; revised manuscript received February 5, 1999, accepted March 15, 1999.
Reprint requests and correspondence: Dr. Peter W. Radke, Medical Clinic I, RWTH University Hospital, Pauwelsstrasse 30, D-52057, Aachen, Germany
prad{at}pcserver.mk1.rwth-aachen.de
| Abstract |
|---|
|
|
|---|
This quantitative angiographic and intravascular ultrasound study determined the mechanisms of acute lumen enlargement and recurrent restenosis after rotational atherectomy (RA) with adjunct percutaneous transluminal coronary angioplasty in the treatment of diffuse in-stent restenosis (ISR).
BACKGROUND
In-stent restenosis remains a significant clinical problem for which optimal treatment is under debate. Rotational atherectomy has become an alternative therapeutic approach for the treatment of diffuse ISR based on the concept of "tissue-debulking."
METHODS
Rotational atherectomy with adjunct angioplasty of ISR was used in 45 patients with diffuse lesions. Quantitative coronary angiographic (QCA) analysis and sequential intravascular ultrasound (IVUS) measurements were performed in all patients. Forty patients (89%) underwent angiographic six-month follow-up.
RESULTS
Rotational atherectomy lead to a decrease in maximal area of stenosis from 80 ± 32% before intervention to 54 ± 21% after RA (p < 0.0001) as a result of a significant decrease in intimal hyperplasia cross-sectional area (CSA). The minimal lumen diameter after RA remained 15 ± 4% smaller than the burr diameter used, indicating acute neointimal recoil. Additional angioplasty led to a further decrease in area of stenosis to 38 ± 12% due to a significant increase in stent CSA. At six-month angiographic follow-up, recurrent restenosis rate was 45%. Lesion and stent length, preinterventional diameter stenosis and amount of acute neointimal recoil were associated with a higher rate of recurrent restenosis.
CONCLUSIONS
Rotational atherectomy of ISR leads to acute lumen gain by effective plaque removal. Adjunct angioplasty results in additional lumen gain by further stent expansion and tissue extrusion. Stent and lesion length, severity of ISR and acute neointimal recoil are predictors of recurrent restenosis.
| ||||||||||||||||||
Rotational atherectomy (RA) has primarily been designed for "differential cutting," the treatment of heavily calcified lesions in native coronary arteries (9,10). Previous intravascular ultrasound (IVUS) studies, however, have shown that RA also effectively ablates noncalcified plaque (11), implicating a potential role for this technique in the treatment of ISR.
The purpose of the present study was to use serial intravascular ultrasound analysis as well as quantitative coronary angiography (QCA) to assess the mechanisms of acute lumen gain after RA with additional angioplasty in the treatment of diffuse ISR. In addition, systematic angiographic follow-up was performed to identify clinical, procedural, angiographic and IVUS predictors of recurrent restenosis.
| Methods |
|---|
|
|
|---|
Rotational atherectomy was performed 7.3 ± 1.0 months after primary stent implantation. Measurements of creatine kinase were performed at baseline, and 6 and 12 h postprocedure. Follow-up angiography was obtained in 40/45 patients (89%) at 5.8 ± 1.5 months after repeat intervention. Clinical follow-up for the remaining five patients was completed by telephone contact.
Patients were prospectively studied with a protocol that had been approved by the institutional ethics committee and patients gave written informed consent before participation.
Rotational atherectomy with adjunct angioplasty procedure. Details of the rotablator technique have been described elsewhere (9,10). In contrast to RA in native coronary arteries, the system (Rotablator system, Scimed, Redmond, Washington) was adjusted to a submaximal rotational speed between 150,000 and 170,000 rounds per minute, taking great care to avoid drops >5,000 rounds. Advancement distal to the stenosis into the previously untreated and unstented vessel segment was carefully avoided. Intracoronary nitroglycerin was given liberally in 0.2-mg bolus doses before and after each passage. A step approach with increasing burr sizes and 2.3 ± 1.0 burrs/lesion (range 1 to 4) with a mean burr size of 1.9 ± 0.5 mm (range 1.25 to 2.38 mm) and a final burr size of 2.05 ± 0.5 mm was performed. The final burr/artery (stent) ratio by IVUS measured 0.8 ± 0.4. Adjunct balloon angioplasty (maximum pressure: 7 ± 1 atm) was performed with a mean balloon size of 3.0 ± 0.6 mm (balloon/artery ratio: 1.3 ± 0.3).
Quantitative coronary angiography analysis: procedural success and recurrent restenosis. Quantitative coronary angiography analysis was performed off-line with an automated edge-detection algorithm (CAAS II System, PieMedical, Maastricht, The Netherlands) with the outer diameter of the contrast-filled catheter used as the calibration standard. The following measurements were obtained: reference diameter, minimal lumen diameter (MLD) within the lesion (mm), mean (overall) luminal diameter of the total stent length (mm) and percent diameter stenosis before intervention, after RA, after angioplasty and at follow-up in multiple projections. The results from the worst view were analyzed. The lesion length was measured as the distance from shoulder to shoulder in all available projections. The longest lesion length was recorded to avoid effects of foreshortening. Due to the complexity and length of many of the lesions with involvement of adjacent segments proximal and distal, a user-defined reference luminal diameter of a proximal and distal angiographically normal appearing segment was chosen.
Procedural success was defined as a final diameter stenosis <50% without major in-hospital complications (death, bypass surgery, additional angioplasty or Q-wave myocardial infarction). Recurrent restenosis after RA at follow-up angiography was defined as
50% diameter stenosis.
Intravascular ultrasound imaging protocol. Studies were performed using a single-element 30-MHz transducer within either a 2.9-F long monorail/common distal lumen imaging sheath or within a 3.2-F short monorail imaging sheath (Boston Scientific Corp.) and an automated pullback with a speed of 0.5 mm/s to obtain a complete and homogeneous image sequence.
Intravascular ultrasound imaging was started 2 min after intracoronary administration of 0.2 mg nitroglycerin. The ultrasound catheter was advanced beyond the target lesion and an imaging run was performed to the aorto-ostial junction. Image quality was adjusted to the relatively low echogenic in-stent neointima during catheter advancement to ensure optimal visualization. Studies were recorded during transducer pullback on high resolution S-VHS tape for off-line analysis.
Quantitative IVUS measurements. The method of IVUS measurements has been validated in vivo and in vitro (1214). In-stent restenosis length was defined as the axial length of the stent (in millimeters) before intervention in which intimal hyperplasia (IH) cross-sectional area (CSA) occupied >75% stent CSA. The off-line planar IVUS measurements (in mm2) were traced in 1-mm increments and included: 1) lumen CSA; 2) stent CSA, and 3) external elastic membrane (EEM) CSA. The IH CSA was defined as the stent CSA minus lumen CSA, and peristent plaque was defined as EEM CSA minus stent CSA. The minimal and the mean lumen CSA within the stent were obtained for calculations of the pre- and postprocedural maximal and mean area stenosis. The lumen, stent, IH, peristent plaque and EEM CSA of the whole stent length were averaged per patient and compared before intervention versus after RA (maximal burr size), after RA versus after angioplasty and preintervention versus after angioplasty (postintervention). In addition, serial analysis (before intervention, after RA, after angioplasty) was performed to separate the contribution of 1) tissue ablation, 2) stent expansion and 3) tissue extrusion to the overall periprocedural lumen gain.
The MLD was defined as the smallest lumen diameter over the whole stent length and was used for calculations of acute neointimal recoil after RA. Recoil was defined as a burr size (diameter in mm)/MLD (mm) ratio >1. When the plaque encompassed the IVUS imaging catheter, the lumen diameter and CSA were assumed to be the size of the catheter. The reference segments selected were the most normal appearing cross sections within 10 mm proximal and distal of the stented segment.
Statistical analysis. Statistical analysis was performed using SPSS for Windows 7.5 (SPSS, Chicago, Illinois) and SAS (Statistical Analysis System, Cary, North Carolina). Continuous data are presented as mean ± SD. Comparisons between groups were performed by use of paired or unpaired t tests or analysis of variance for repeated measures with post hoc analysis for continuous variables. Qualitative data are presented as frequencies and comparison between quantitative data was performed with chi-square statistics. Initially, simple linear regression analysis was performed to evaluate the relationship between the minimal lumen diameter obtained by IVUS and QCA. Furthermore, the limits of agreement between pairs of measurements were determined according to the method described by Bland and Altman (15). The mean difference between the methods investigated is the systematic error (bias) and two standard deviations are defined as limits of agreement (95% confidence interval). Predictors of restenosis were calculated by univariate and multivariate logistic regression analysis. A p value <0.05 was considered statistically significant.
| Results |
|---|
|
|
|---|
|
After adjunct angioplasty the minimal lumen CSA increased significantly as a result of an increase in stent CSA and a decrease in IH CSA. Conversely, the maximal area of stenosis decreased from 54 ± 21% to 38 ± 12%. Both the peristent plaque CSA and the EEM CSA increased also from after RA to after angioplasty.
The contribution of plaque removal, stent expansion and plaque extrusion to the overall periprocedural lumen gain was as follows: 1) plaque removal (during RA), 37 ± 11%; 2) further stent expansion, 49 ± 15%; 3) plaque extrusion 14 ± 10 (during adjunct angioplasty).
Angiographic six-month follow-up and predictors for recurrent restenosis. Angiographic follow-up was available in 40/45 (89%) patients. Recurrent restenosis was observed in 18/40 patients (45%). Clinical follow-up after 6.6 ± 2.5 months was available for all patients and revealed a rate of recurrent revascularization of 38% (17/45). Four variables were identified as predictors of recurrent restenosis at six-month angiographic follow-up: percent diameter stenosis before intervention (83 ± 22% vs. 72 ± 17%, p < 0.01), stent length (40.5 ± 21.3 mm vs. 21.5 ± 14.1 mm, p < 0.001), total lesion length (35.1 ± 20.2 mm vs. 15.2 ± 14.1 mm, p < 0.001) and the amount of neointimal recoil after RA (23.2 ± 13.6% vs. 8.9 ± 8.3%, p < 0.001). The only independent predictor by multivariate analysis, however, was neointimal recoil (p < 0.01, r2 = 0.44). Other clinical (age, gender, diabetes, lesion location, stent type), procedural (burr/artery ratio), angiographic (vessel size, diameter stenosis) or IVUS variables (amount of plaque ablation, intimal hyperplasia) were statistically not associated with recurrent angiographic restenosis.
Comparison of MLD measurements obtained by IVUS and QCA analysis. All lesions with an angiographic MLD less than the IVUS catheter (<1 mm) had to be excluded; therefore, a subset of 18 lesions were included with regard to preinterventional diameters. For comparative measurements after RA and after adjunct angioplasty, the minimal lumen diameters of all 49 lesions were available for analysis (Fig. 1). Simple linear regression analysis showed low correlation coefficients between the two methods throughout the whole procedure (r value: 0.39 to 0.57). The IVUS values before intervention and after RA were systematically higher than the corresponding angiographic values (Fig. 1 A and B). In contrast, there was no systematic bias between QCA and IVUS after adjunct angioplasty despite a low correlation coefficient (r = 0.39, Fig. 1 C).
|
| Discussion |
|---|
|
|
|---|
Mechanisms of "tissue-debulking" by rotablation for in-stent restenosis. In the present study, planar IVUS measurements revealed that RA effectively ablates in-stent neointimal tissue and contributes 37 ± 11% to the overall procedural lumen gain when adjunct angioplasty is performed. An example of the complex clinical situation is shown in Figure 2. Neointima tissue usually is inhomogeneously distributed and the rotablator only removes those portions of the plaque that are occlusive enough to be accessible for the device (focal plaque ablation). Large sections of the stent will not be effectively treated by the burr, although there is significant plaque burden.
|
Similar phenomena have also been described for nonstented, noncalcified lesions treated by RA (11,16). This is in contrast to fibrotic and calcified lesions, in which effective plaque removal without elastic recoil has been demonstrated by IVUS (10). The differences between noncalcified and calcified coronary lesions in their response to high speed rotational atherectomy may be explained in part by the principle of "differential cutting" by which the rotablator is thought to act.
Adjunct angioplasty after RA. Adjunct angioplasty after RA contributes 63 ± 16% to the overall procedural lumen gain mainly by further stent expansion (77 ± 14%) and, to a smaller degree, by tissue extrusion through the stent struts (23 ± 11%). The residual mean and maximal area stenosis after adjunct low pressure angioplasty are 30 ± 19% and 38 ± 12% respectively. The relatively high residual area stenosis may be caused by the inflation pressure (7 ± 1 atm) used in this series of patients. This relatively low inflation pressure was intended to reduce additional vessel trauma with potentially beneficial long-term effects (recurrent restenosis rates). Adjunct high pressure angioplasty (>15 atm) might result in favorable acute angiographic results; however, the postprocedural lesion diameter was not a predictor of recurrent restenosis at six-month angiographic follow-up.
Comparison with DCA and ELCA as alternative debulking techniques. Directional coronary atherectomy (DCA) provides the only technique that may be able to completely remove in-stent neointima; however, aggressive debulking utilizing this device may be associated with stent destruction (17,18). In contrast, RA did not result in stent destruction or migration. Excimer laser coronary angioplasty (ELCA) for in-stent restenosis results in a lower overall target vessel revascularization rate compared with angioplasty alone, supporting the concept of tissue debulking (19). The mechanisms of ELCA for the treatment of in-stent restenosis have recently been described in detail with 29 ± 15% of the procedural lumen gain contributable to atheroablation (19), compared with 37 ± 11% when RA is used for debulking as demonstrated in this study. Preliminary comparative data also indicated that RA leads to a greater decrease in IH volume than ELCA (20).
Treatment of in-stent restenosis by angioplasty alone. When angioplasty is used as a stand-alone procedure in the treatment of in-stent restenosis, further stent expansion quantitatively accounts for more than half of the total lumen enlargement as compared with the decrease in neointimal tissue burden (56 ± 28% vs. 44 ± 28%) (21). The amount of tissue extrusion or compression induced by adjunct angioplasty was smaller in the present series as RA induced significant tissue ablation and therefore reduced the volume of in-stent tissue available for extrusion/compression. In addition, the maximal pressure used for adjunct angioplasty in this study was lower (7 ± 1 atm) than for angioplasty alone (>10 atm) and the balloon size for adjunct angioplasty after RA was the same as for primary stent implantation.
The restenosis rate after angioplasty of focal lesions is reported to be as low as 22% (6). In lesions of intermediate length (length: 8.93 ± 7.30 mm), target vessel revascularization rates are significantly higher (38%) (19). Rotational atherectomy with adjunct angioplasty results in an improved long-term clinical outcome compared with angioplasty alone in the setting of diffuse ISR (clinical recurrence 25% vs. 47% at six months) as reported in the first comparative study (22). Additionally, in diffuse lesions treated by angioplasty alone, recurrent restenosis rates may be as high as 80% (8). In light of the latter results, a restenosis rate of 45% in long lesions (22.4 ± 20.2 mm) appears to be favorable; however, additional antiproliferative pharmacotherapy or intravascular brachytherapy may further improve long-term outcome after treatment of ISR.
Predictors of recurrent restenosis. Based on the quantitative analysis of the angiographic follow-up, stent and lesion length and preinterventional diameter stenosis were identified as predictors of recurrent restenosis after six months. The predictive value of serial stent implantation, and thereby lesion length, on restenosis rates has been described for primary stent implantation (23) and turns out to be a risk factor in the clinical setting of RA for in-stent restenosis as well.
Most interestingly, the amount of acute neointimal plaque recoil was also identified as a predictor of restenosis after rotablation. Recoil after RA as an instantaneous "restenosis" mechanism obviously reflects an unfavorable lesion response to the rotablator for unknown reasons.
However, a high burr/artery ratio or the absolute amount of tissue debulking, as suggested by Sharma et al. (24), could not be proven to have beneficial effects on restenosis rates in our small series of patients.
Study limitations.
Conclusions. Rotational atherectomy of in-stent restenosis leads to significant atheroma ablation of neointima supporting the concept of "tissue-debulking." Angiographic restenosis is observed in 45% of patients with diffuse lesions. Stent and lesion length, preinterventional diameter stenosis and acute neointimal recoil are predictors of angiographic restenosis. Differences between angioplasty as a stand-alone procedure compared with RA with adjunct angioplasty and other debulking techniques in the treatment of diffuse in-stent restenosis are yet unknown. Several randomized trials have been initiated to provide insight into the acute and long-term effects of the different treatment modalities.
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
P. W Radke, S. Kobella, A. Kaiser, A. Franke, D. Schubert, E. Grube, P. Hanrath, and R. Hoffmann Treatment of in-stent restenosis using a paclitaxel-eluting stent: acute results and long-term follow-up of a matched-pair comparison with intracoronary {beta}-radiation therapy Eur. Heart J., June 1, 2004; 25(11): 920 - 925. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Bhatia, R Bhatia, and M Dhindsa Drug-eluting stents: new era and new concerns Postgrad. Med. J., January 1, 2004; 80(939): 13 - 18. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. E. Ajani, R. Waksman, E. Cheneau, D.-H. Cha, S. McGlynn, M. Castagna, R. C. Chan, L. F. Satler, K. M. Kent, A. D. Pichard, et al. The outcome of percutaneous coronary intervention in patients with In-Stentrestenosis who failed intracoronary radiation therapy J. Am. Coll. Cardiol., February 19, 2003; 41(4): 551 - 556. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.W Radke, A Kaiser, C Frost, and U Sigwart Outcome after treatment of coronary in-stent restenosis: Results from a systematic review using meta-analysis techniques Eur. Heart J., February 1, 2003; 24(3): 266 - 273. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Spanos, G. Stankovic, J. Tobis, and A. Colombo The challenge of in-stent restenosis: insights from intravascular ultrasound Eur. Heart J., January 2, 2003; 24(2): 138 - 150. [Full Text] [PDF] |
||||
![]() |
J. vom Dahl, U. Dietz, P. K. Haager, S. Silber, L. Niccoli, H. J. Buettner, F. Schiele, M. Thomas, P. Commeau, D. R. Ramsdale, et al. Rotational Atherectomy Does Not Reduce Recurrent In-Stent Restenosis: Results of the Angioplasty Versus Rotational Atherectomy for Treatment of Diffuse In-Stent Restenosis Trial (ARTIST) Circulation, February 5, 2002; 105(5): 583 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Adamian, A. Colombo, C. Briguori, T. Nishida, F. Marsico, C. Di Mario, R. Albiero, I. Moussa, and J. W. Moses Cutting balloon angioplasty for the treatment of in-stent restenosis: a matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty J. Am. Coll. Cardiol., September 1, 2001; 38(3): 672 - 679. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Leon, P. S. Teirstein, J. W. Moses, P. Tripuraneni, A. J. Lansky, S. Jani, S. C. Wong, D. Fish, S. Ellis, D. R. Holmes, et al. Localized Intracoronary Gamma-Radiation Therapy to Inhibit the Recurrence of Restenosis after Stenting N. Engl. J. Med., January 25, 2001; 344(4): 250 - 256. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hoffmann and G.S. Mintz Coronary in-stent restenosis--predictors, treatment and prevention Eur. Heart J., November 1, 2000; 21(21): 1739 - 1749. [PDF] |
||||
![]() |
C Di Mario, F Marsico, M Adamian, E Karvouni, R Albiero, and A Colombo New recipes for in-stent restenosis: cut, grate, roast, or sandwich the neointima? Heart, November 1, 2000; 84(5): 471 - 475. [Full Text] |
||||
![]() |
R. Koster, J. Kahler, W. Terres, J. Reimers, S. Baldus, D. Hartig, J.u. Berger, T. Meinertz, and C. W. Hamm Six-month clinical and angiographic outcome after successful excimer laser angioplasty for in-stent restenosis J. Am. Coll. Cardiol., July 1, 2000; 36(1): 69 - 74. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Carrozza Jr. In-stent restenosis: should an old device treat a new problem? J. Am. Coll. Cardiol., May 1, 2000; 35(6): 1577 - 1579. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |