J Am Coll Cardiol, 1999; 33:1903-1908
© 1999 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, J. M.
Right arrow Articles by Oz, M. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, J. M.
Right arrow Articles by Oz, M. C.

CLINICAL STUDIES

Improved survival rates support left ventricular assist device implantation early after myocardial infarction

Jonathan M. Chen, MDa, Joseph J. DeRose, MDa, James P. Slater, MDa, Talia B. Spanier, MDa, Todd M. Dewey, MDa, Katherine A. Catanese, MSNa, Margaret A. Flannery, RNa and Mehmet C. Oz, MD, FACCa

a Department of Surgery, Division of Cardiothoracic Surgery, Columbia-Presbyterian Medical Center, New York, New York, USA

Manuscript received May 21, 1998; revised manuscript received January 8, 1999, accepted February 25, 1999.

Reprint requests and correspondence: Dr. Jonathan M. Chen, Department of Surgery, Presbyterian Hospital #295, 622 West 168th Street, New York, New York 10032
jmc23{at}columbia.edu


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
OBJECTIVES

Implantation of left ventricular assist devices (LVADs) early after acute myocardial infarction (MI) has traditionally been thought to be associated with high mortality rates due to technical limitations and severe end-organ dysfunction. At some experienced centers, doctors have refrained from earlier operation after MI to allow for a period of hemodynamic and end-organ stabilization.

METHODS

We retrospectively investigated the effect of preoperative MI on the survival rates of 25 patients who received a Thermocardiosystems Incorporated LVAD either <2 weeks (Early) (n = 15) or >2 weeks (Late) (n = 10) after MI. Outcome variables included perioperative right ventricular assistance (and right-sided circulatory failure), hemodynamic indexes, percent transplanted or explanted, and mortality.

RESULTS

No statistically significant differences were demonstrated between demographic, perioperative or hemodynamic variables between the Early and Late groups. Patients in the Early group demonstrated a lower rate of perioperative mechanical right ventricular assistance, but had a higher rate of perioperative inhaled nitric oxide use. In addition, 67% of patients in the Early group survived to transplantation and 7% to explantation, findings comparable to those in the Late group (60% and 0% respectively).

CONCLUSIONS

This clinical experience suggests that patients may have comparable outcomes whether implanted early or late after acute MI. These data therefore support the early identification and timely application of this modality in post-MI LVAD candidates, as this strategy may also reveal a subgroup of patients for whom post-MI temporary LVAD insertion may allow for full ventricular recovery.

Abbreviations and Acronyms
  CABG = coronary artery bypass graft proc
  IABP = intra-aortic balloon pump
  LVAD = left ventricular assist device
  MI = myocardial infarction
  MSOF = multisystem organ failure
  RVAD = right ventricular assist device
  TCI = Thermocardiosystems Incorporated


Implantation of left ventricular assist devices (LVADs) early after acute myocardial infarction (MI) has traditionally been thought to be associated with mortality rates as high as 75% (1–8). Although initially indicated for both postcardiotomy shock and failure to wean from cardiopulmonary bypass (conditions often associated with a preoperative MI), LVAD insertion after MI has sometimes been delayed at experienced centers to allow for hemodynamic and end-organ stabilization before LVAD insertion. Although this strategy affords the possibility of ventricular recovery without the need for operation, the concomitant risks of ventricular decompensation and the development of malignant arrhythmias remain high (9).

As experience with the perioperative management of device recipients has grown, recent interest has focused both on the prompt implantation of LVADs soon after the development of cardiogenic shock, as well as on the use of LVADs as a so-called "bridge to recovery." With this has come a renewed emphasis on the timely implantation of LVADs early after MI to allow for the possible salvage of viable myocardium that may benefit from temporary ventricular decompression and mechanical circulatory assistance, thereby ultimately allowing for LVAD removal and full ventricular recovery.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Between March 1991 and January 1998, 168 patients underwent insertion of a Thermocardiosystems (TCI) (Thermocardiosystems, Woburn, Massachusetts) LVAD at the Columbia-Presbyterian Medical Center in New York City. Of this entire cohort, 25 patients had an acute MI less than three months before LVAD insertion. Myocardial infarction was defined by clinical history, serial electrocardiographic analysis, cardiac enzymatic evidence (isoenzymes of creatine phosphokinase) and echocardiography. These patients were divided on the basis of the interval from MI to LVAD insertion into cohorts of those who experience a MI less than two weeks (Early) or great than two weeks (Late) after MI. Patients with a MI more than three months before LVAD insertion were excluded from analysis.

Demographic/outcome variables.   Demographic variables analyzed included age, gender, type of LVAD inserted (pneumatic or vented electric), preoperative assistance with an intra-aortic balloon pump (IABP) or temporary ventricular assist device, and presenting hemodynamics (central venous pressure, pulmonary artery pressure, pulmonary capillary wedge pressure and cardiac output). Perioperative outcome variables included the need for a right ventricular assist device (RVAD), the use of perioperative inhaled nitric oxide and overall perioperative hemodynamics (see above). Long-term outcome variables included number transplanted, number explanted, overall mortality and perioperative complications.

The TCI device.   The TCI LVAD is a pusher-plate device with a maximal stroke volume of approximately 85 cc. It is implanted through a median sternotomy with the inflow graft and Teflon sewing cuff inserted into the left ventricular apex, and the Dacron outflow graft anastomosed to the ascending aorta after the institution of standard cardiopulmonary bypass (Fig. 1). The inflow and outflow conduits have 25-mm porcine valves to ensure unidirectional flow. The inflow cuff is sewn directly to the left ventricular apex, after removal of a "core" of apical tissue; in the postinfarction setting, particular attention is paid to placing large full-thickness, pledgeted bites in the ventricular myocardium through the infarct zone. The outflow graft is then anastomosed to the right lateral portion of the ascending aorta. A properitoneal pocket is created for the device in the left upper quadrant, before heparinization if possible. The device itself, when implanted in the left upper quadrant properitoneal pocket, allows for both the drive line and vent line also to exit the abdominal wall in the left lower quadrant.



View larger version (51K):
[in this window]
[in a new window]
 
Figure 1 Illustration demonstrating the implantable Thermocardiosystems Incorporated vented electric left ventricular assist device (LVAD).

 
The device is normally operated in the automatic mode, which programs ejection when the device is 95% full. The device may be actuated by a power source that is either pneumatically or electrically driven.

Statistics.   All results were recorded as the mean plus or minus the standard deviation. Demographic and outcome variables were compared between the two cohorts by Fischer exact test for 2 x 2 tables. Statistical significance was defined as a p value less than 0.05.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Of the 25 patients who had experienced an acute MI before LVAD insertion, 15 (60%) patients made up the Early cohort (less than two weeks after MI) and 10 (40%) patients made up the Late cohort (greater than two weeks after MI). Four (25%) of the patients in the Early cohort and one (10%) of the patients in the Late cohort underwent LVAD insertion in the setting of postcardiotomy cardiogenic shock after failed coronary artery bypass graft (CABG) revascularization. Where available, peri-MI creatine phosphokinase values were 2,499.3 ± 1,945.5 in the Early cohort, and 1,758.5 ± 173.2 in the Late group; q waves on electrocardiogram were present in nine (60%) Early and six (60%) Late patients.

Demographic variables for the two cohorts are displayed in Table 1. There were no significant differences between Early and Late cohorts on the basis of initial demographic profiles. Patients in the Early cohort underwent device implantation 5.1 ± 5.1 days after MI (range 0 to 14 days); patients in the late cohort underwent device implantation 22.7 ± 8.0 days after MI (range 16 to 43 days). Patients in the Early group more often underwent LVAD insertion in the setting of postcardiotomy cardiogenic shock after failed CABG revascularization (26% vs. 10%) when compared with the Late cohort.


View this table:
[in this window]
[in a new window]
 
Table 1 Patient Demographics in the Early and Late Cohorts

 
Patients in both cohorts had comparable preoperative support with IABPs, and two patients in the Early cohort underwent temporary LVAD support with either a BioMedicus (Medtronics BioMedicus, Eden Prarie, Minnesota) or ABIOMED (ABIOMED Cardiovascular, Danvers, Massachusetts) LVAD. Preoperative hemodynamic profiles were not significantly different between the two cohorts, as reflected by pulmonary capillary wedge pressure (28 ± 5.0 vs. 29 ± 6.0 mm Hg, Early vs. Late) or by cardiac index (2 ± 0.5 vs. 1.8 ± 0.4 liters/min/m2, Early vs. Late).

Patients in the Early cohort utilized fewer RVADs in the perioperative period (7% vs. 20%), but notably were administered inhaled nitric oxide (30%) more often than patients in the Late cohort (0%) for perioperative right-sided circulatory failure. Patients in the Early cohort were supported with mechanical left ventricular assistance for a mean of 90.3 ± 106.3 days (range 3 to 412 days); those in the Late cohort were supported for 97.1 ± 92.2 days (range 6 to 304 days).

Ventricular tachycardia and ventricular fibrillation afflicted four patients in both Early and Late cohorts. One patient in the Early cohort experienced cardiac arrest preoperatively secondary to ventricular fibrillation. The six other patients all experienced ventricular tachycardia and ventricular fibrillation in the immediate postoperative period after LVAD implantation; in all patients ventricular fibrillation was ultimately controlled with electrical cardioversion and medical management while on device support.

Patients were followed until the point of transplantation, explantation or death; mortality analysis was based on these three censor criteria. The leading cause of death in both cohorts was multisystem organ failure (MSOF), most often related to sepsis. One patient in the early group died of MSOF four days after LVAD insertion, and another died of a pulmonary embolus three days after LVAD insertion. One additional patient in the Early group, who underwent a CABG procedure one day after MI, and an LVAD implantation seven days later, was successfully weaned from device support and underwent device removal 101 days after device support. At 24 months after explantation, he was noted to have a 50% estimated ejection fraction by nuclear ventriculography multigated acquisition scan; the patient ultimately died of a presumed (unwitnessed) fatal arrhythmia approximately 26 months after his LVAD removal.


    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Despite advances in the timely medical management of the syndrome and its sequelae, cardiogenic shock associated with acute MI remains a diagnosis associated with a mortality rate between 65% and 80% (10). In addition, the use of IABP counterpulsation as a temporizing measure while awaiting ventricular recovery continues to have a 30% to 75% mortality rate in the setting of acute MI, an outcome comparable to that associated with medical therapy alone (11–13). Although the success of both LVAD support for postcardiotomy cardiogenic shock and LVADs as a bridge to transplantation has been well established, their use for post-MI cardiogenic shock, either postcardiotomy or after medical management has failed, remains to be defined fully (14).

Since the first description of mechanical left ventricular assistance for acute MI in 1957, the application of LVADs and biventricular assist devices for this indication has continued to expand despite variable results (1–8). Early experience with LVAD insertion for acute MI revealed survival rates between 10% and 60%, a finding that discouraged the early application of mechanical ventricular assistance for this indication. However, later studies documenting both the beneficial influence of ventricular assistance on end-organ function, as well as the possibility of ventricular decompression allowing for full or partial myocardial recovery have led investigators to revisit the notion of early LVAD insertion for acute MI (15).

Experienced centers have sometimes refrained from earlier operation in this setting to allow for hemodynamic and end-organ stabilization before LVAD insertion. For these potential assist device recipients, the concomitant risks of infarction extension and malignant arrhythmia must be weighed carefully against those of the operation itself. Although in the early years of device support these risks were comparable, recent improvement in survival statistics for LVAD implantation has rendered the risks of the operation considerably less. Ventricular decompression and the restoration of blood flow to the myocardium have been demonstrated to limit infarct size and expansion, a finding supportive of early LVAD insertion not only as a bridge to transplantation, but also as a bridge to recovery (16,17). In addition, the development of malignant arrhythmias due to infarction extension may be exacerbated further by medical management itself (which may also reduce ventricular function), and we and others have described successful long-term LVAD support for patients with active ventricular arrhythmias (17–20).

Several advances in surgical implant technique have also substantially improved LVAD recipient survival postinfarction. We have in recent years placed importance during implantation on the use of pericardial pledgeted sutures for the inflow cannula, with particular emphasis on the use of large, full-thickness bites of ventricular myocardium through the infarct zone. The short inflow cannula of the TCI device used is also advantageous in such patients, in that its shorter, wider inflow substantially reduces the residual left ventricular pressure, ultimately leading to fewer bleeding complications. Finally, our increasing use of therapeutic adjuncts, including inhaled nitric oxide and low dose intravenous arginine vasopressin, has undoubtedly dramatically improved the morbidity of this difficult patient population (21,22).

Our experience described herein is notable for a series of observations. First, patients in the Early cohort had a substantially decreased mortality (26%) when compared with those in the Late cohort (40%) (p > 0.05). Patients were more likely to have had an LVAD implanted early after acute MI in recent years, owing to a programmatic change in our sensibility over time; this change is reflected in the greater proportion of more recent vented electric LVADs implanted in the Early group. Although this tendency may, to some extent, have biased the data described, both groups notably comprised patients distributed throughout the time period studied. Furthermore, the overall survival rate to transplantation or explantation in the Early cohort (74%) is comparable to that described by us in previous reviews of our experience with the electric TCI LVAD, suggesting that this cohort of patients with ischemic cardiomyopathy is not at a significant survival disadvantage owing to the etiology of their heart failure (22).

Second, right-sided circulatory failure (defined as the need for either an RVAD, or the use of inhaled nitric oxide) remains a substantial source of morbidity for acute MI patients in the immediate post-LVAD setting, afflicting nearly one third of patients in both cohorts combined. The Early cohort enjoyed an increased use of nitric oxide (30%), and decreased use of RVADs (7%), when compared with the Late cohort (0% and 20% respectively), a fact that again likely reflects their more recent dates of implantation. We have previously reported the efficacy of inhaled nitric oxide in LVAD recipients for perioperative right-sided circulatory failure, and have noted a substantial decrease in our institutional use of RVADs as a result (23,24). The trends we report herein also parallel previous data reported from our institutional experience with the TCI device in 1990 through 1997, in which 27% of an overall cohort of 85 patients experienced intraoperative right-sided circulatory failure; 4/16 pneumatic device recipients, and 2/8 electric device recipients required RVAD insertion (compared with 3/16 and 6/8 requiring nitric oxide therapy respectively) (22). Moreover, these data refute the notion that biventricular failure may account for the discrepancy in survival between cohorts, as the overall use of therapeutic adjuncts for right-sided circulatory failure was in fact higher in the Early group.

Third, we demonstrated a 30% to 40% rate of malignant ventricular arrhythmias that developed within both cohorts (one of which accounted for a preoperative cardiac arrest in a patient in the Early group), suggesting that the risk of this occurrence in the perioperative period for LVAD patients after acute MI remains substantial. This finding is consistent with other published reports that document an incidence of post-MI ventricular tachyarrhythmias of as high as 65% (9). All patients who experienced ventricular fibrillation perioperatively underwent electrical cardioversion and subsequent medical management with antiarrhythmic medications. These patients tolerated their ventricular arrhythmias, and all eight patients survived to transplantation or explantation of their device.

Finally, the primary cause of death in the Early cohort was MSOF, most often due to overwhelming sepsis. It remains controvertible whether early implantation may not allow for scrutiny of all potential negative determinants of post-LVAD outcome (e.g., infection), as has been suggested by others (24). Arguably, those with "long-standing" (>2 weeks) ischemic cardiomyopathy should be at an increased risk of infectious and end-organ postoperative complications owing to prolonged hypoperfusion and in-hospital associated risks; however, these observations require a large prospective randomized analysis for confirmation.

Limitations.   Several limitations are important to note with regard to these data. First, these results represent the findings of a retrospective clinical experience, rather than a prospective randomized trial. Second, although unexpectedly favorable outcomes are described for patients implanted early after MI, undoubtedly certain outcomes (e.g., the rate of survival to transplantation) may have been tempered in part both by the patients’ clinical status, as well as by the prevailing practice patterns in transplantation; these results must therefore must be viewed with caution. Despite this, the inherent characteristics of a presumably sicker cohort (those early after MI) should have biased these data against describing comparable outcome results; the lack of appreciable differences in preoperative characteristics in both cohorts argues against egregious differences in patient selection. The selection criteria (LVAD "screening scale") on which we have based our decision for implantation have been described previously (26). Clearly, the time interval since a prior MI, although an important factor, is but one of many contributing demographic characteristics affecting overall outcome. Although these data do not promote the implantation of LVADs early after MI for all patients, they do suggest its feasibility and furthermore refute its position as either an absolute or relative contraindication.

Conclusions.   These data support the early implantation of LVADs for acute myocardial infarction either postcardiotomy, or in the setting of decompensation despite maximal medical management. The comparable rates of survival to transplantation or explantation refute the notion of a two-week "recovery period," particularly in light of recent trends toward the use of mechanical ventricular assistance for myocardial recovery. Many of the patients in the Early cohort while receiving temporary IABP support were transferred to our institution for either LVAD insertion, or for weaning from IABP. We contend that for these patients, the aggressive implantation of IABPs or temporary assist devices—and the rapid referral to tertiary care centers for more long-term mechanical support—will allow for a greater percentage of patients who may be weaned completely after intermediate-term LVAD support, end-organ and hemodynamic stabilization, and partial or full ventricular recovery. Taken together, these findings support the notion of a seamless "bridge to recovery" program in which smaller hospitals with temporary device programs may refer patients (such as those who undergo temporary device insertion early after acute MI) to larger centers for longer term device support as a bridge to transplantation, destination or recovery (25).


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 

  1. Stuckey JH, Newman MM, Dennis C, et al. The use of the heart-lung machine in selected cases of acute myocardial infarction. Surg Forum. 1957;8:342–344[Medline]
  2. Pae WE, Pierce WS. Temporary left ventricular assistance in acute myocardial infarction and cardiogenic shock. Chest. 1981;79:692–695[Abstract/Free Full Text]
  3. Pennington DG, McBride LR, Kanter KR, et al. Effect of postoperative myocardial infarction on survival of postcardiotomy patients supported with ventricular-assist devices. Circulation. 1988;78(Suppl III):110–115
  4. Sapirstein JS, Pae WE, Aufiero TX, Boehmer JP, Pierce WS. Long-term left ventricular assist device use before transplantation. ASAIO J. 1995;41:M530–M534[Medline]
  5. Farrar DJ, Lawson LH, Litwak P, Cederwall G. Thoratec VAD system as a bridge to heart transplantation. J Heart Transplant. 1990;9:415–423[Medline]
  6. Takano H, Nakatani T, Noda H, et al. Clinical consideration of a left ventricular assist system for acute myocardial infarction with cardiogenic shock. Trans Am Soc Artif Intern Organs. 1986;32:467–473
  7. Noda H, Takano H, Taenaka Y. Treatment of acute myocardial infarction with cardiogenic shock using left ventricular assist device. Int J Artif Organs. 1989;12:75–79[Medline]
  8. Moritz A, Wolner E. Circulatory support with shock due to acute myocardial infarction. Ann Thorac Surg. 1993;55:238–244[Abstract]
  9. Maggioni AP, Zuanetti G, Franzosi MG, et al. Prevalence and prognostic significance of ventricular arrhythmias after acute myocardial infarction in the fibrinolytic era, GISSI-2 results. Circulation. 1993;87:312–322[Abstract/Free Full Text]
  10. Hands ME, Rutherford JD, Muller JE, et al. The in-hospital development of cardiogenic shock after myocardial infarction: incidence, predictors of occurrence, outcome and prognostic factors. J Am Coll Cardiol. 1989;14:40–46[Abstract]
  11. Pi K, Block PC, Warner MG, Diethrich EB. Major determinants of survival and nonsurvival of intraaortic balloon pumping. Am Heart J. 1995;130:849–853[CrossRef][Medline]
  12. Torchiana DF, Hirsch G, Buckley MJ, et al. Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995. J Thorac Cardiovasc Surg. 1997;113:758–769[Abstract/Free Full Text]
  13. Lee L, Bates ER, Pitt WR, Walton JA, Laufer N, O’Neill WW. PTCA improves survival. Circulation. 1988;78:1345–1351[Abstract/Free Full Text]
  14. DeRose JJ, Umana JP, Argenziano M, et al. Improved results for postcardiotomy cardiogenic shock with the use of implantable left ventricular assist devices. Ann Thorac Surg. 1997;64:1757–1763[Abstract/Free Full Text]
  15. Levin HR, Burkhoff D, Oz MC, Chen JM, Rose EA, Packer M. Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading. Circulation. 1995;91:2717–2720[Abstract/Free Full Text]
  16. Nakatani T, Takano H, Noda H, et al. Therapeutic effect of a left ventricular assist device on acute myocardial infarction evaluated by magnetic resonance imaging. Trans Am Soc Artif Intern Organs. 1986;32:201–206
  17. Loisance D, Deleuze M, Hillion ML, et al. The real impact of mechanical bridge strategy in patients with severe acute infarction. ASAIO Trans. 1990;36:M135–M137[Medline]
  18. Lewis CT, Graham TR, Marrinan MT. The use of an implantable left ventricular assist device following irreversible ventricular fibrillation secondary to massive myocardial infarction. J Thorac Cardiovasc Surg. 1979;78:626–632[Abstract]
  19. Oz MC, Rose EA, Slater J, Kuiper JJ, Catanese KA, Levin HR. Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices. J Am Coll Cardiol. 1994;24:1688–1691[Abstract]
  20. Holman WL, Roye GD, Bourge RC, McGiffin DC, Iyer SS, Kirklin JK. Circulatory support for myocardial infarction with ventricular arrhythmias. Ann Thorac Surg. 1995;59:1230–1231[Abstract/Free Full Text]
  21. Argenziano M, Choudhri AF, Oz MC, Rose EA, Smith CR, Landry DW. A prospective randomized trial of arginine vasopressin in the treatment of vasodilatory shock after left ventricular assist device placement. Circulation. 1997;96(Suppl 9):II-286–II-290
  22. DeRose JJ, Argenziano M, Sun BC, Reemtsma K, Oz MC, Rose EA. Implantable left ventricular assist devices: an evolving long-term cardiac replacement therapy. Ann Surg. 1997;226:461–468[CrossRef][Medline]
  23. Argenziano M, Choudhri AF, Moazami N, et al. A randomized, placebo-controlled trial of inhaled nitric oxide in LVAD recipients with pulmonary hypertension. Ann Thorac Surg. 1998;65:340–345[Abstract/Free Full Text]
  24. Chen JM, Levin HR, Rose EA, et al. Experience with right ventricular assist devices for perioperative right sided circulatory failure. Ann Thorac Surg. 1996;61:305–310[Abstract/Free Full Text]
  25. Loisance D, Dubois Rande JL, Deleuze PH, et al. Pharmacological bridge to cardiac transplantation. Eur J Cardiothorac Surg. 1989;3:196–202[Abstract]
  26. Oz MC, Goldstein DJ, Pepino P, et al. Screening scale predicts patients successfully receiving long-term implantable left ventricular assist devices. Circulation. 1995;92(Suppl 9):II169–II173



This article has been cited by other articles:


Home page
Card Surg AdultHome page
I. George and M. C. Oz
Myocardial Revascularization after Acute Myocardial Infarction
Card. Surg. Adult, January 1, 2008; 3(2008): 669 - 696.
[Full Text]


Home page
Card Surg AdultHome page
S. Aggarwal, F. Cheema, M. C. Oz, and Y. Naka
Long-Term Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 1609 - 1628.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
B. G. Leshnower, T. G. Gleason, M. L. O'Hara, A. Pochettino, Y. J. Woo, R. J. Morris, T. J. Gardner, and M. A. Acker
Safety and Efficacy of Left Ventricular Assist Device Support in Postmyocardial Infarction Cardiogenic Shock
Ann. Thorac. Surg., April 1, 2006; 81(4): 1365 - 1371.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. C. Dang, V. K. Topkara, M. Leacche, R. John, J. G. Byrne, and Y. Naka
Left ventricular assist device implantation after acute anterior wall myocardial infarction and cardiogenic shock: A two-center study
J. Thorac. Cardiovasc. Surg., September 1, 2005; 130(3): 693 - 698.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. C. Lee, M. C. Oz, A. D. Weinberg, and W. Ting
Appropriate timing of surgical intervention after transmural acute myocardial infarction
J. Thorac. Cardiovasc. Surg., January 1, 2003; 125(1): 115 - 120.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
D. C. Lee, W. Ting, and M. C. Oz
Myocardial Revascularization after Acute Myocardial Infarction
Card. Surg. Adult, January 1, 2003; 2(2003): 639 - 658.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
D. C. Lee, M. C. Oz, A. D. Weinberg, S. X. Lin, and W. Ting
Optimal timing of revascularization: transmural versus nontransmural acute myocardial infarction
Ann. Thorac. Surg., April 1, 2001; 71(4): 1198 - 1204.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. W. Stevenson and R. L. Kormos
Mechanical cardiac support 2000: current applications and future trial design: June 15-16, 2000 Bethesda, Maryland
J. Am. Coll. Cardiol., January 1, 2001; 37(1): 340 - 370.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. J. Park, D. Q. Nguyen, A. J. Bank, S. Ormaza, and R. M. Bolman III
Left ventricular assist device bridge therapy for acute myocardial infarction
Ann. Thorac. Surg., April 1, 2000; 69(4): 1146 - 1151.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, J. M.
Right arrow Articles by Oz, M. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, J. M.
Right arrow Articles by Oz, M. C.


HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK