cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1999; 33:311-316
© 1999 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Victor, F.
Right arrow Articles by Daubert, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Victor, F.
Right arrow Articles by Daubert, C.

CLINICAL STUDIES

Optimal right ventricular pacing site in chronically implanted patients

A prospective randomized crossover comparison of apical and outflow tract pacing

Frederic Victor, MDa, Christophe Leclercq, MDa, Philippe Mabo, MDa, Dominique Pavin, MDa, Anne Deviller, MD{dagger}, Christian de Place, MDa, Philippe Pezard, MD*, Jacques Victor, MD* and Claude Daubert, MD, FESCa

a Department of Cardiology, University Hospital of Rennes, Rennes, France
* Department of Cardiology, University Hospital of Angers, Angers, France
{dagger} Department of Nuclear Medicine, University Hospital of Rennes, Rennes, France

Manuscript received April 29, 1998; revised manuscript received August 17, 1998, accepted October 6, 1998.

Reprint requests and correspondence: Dr. Claude Daubert, Département de Cardiologie & Maladies Vasculaires, Centre Cardio-Pneumologique, Pontchaillou CHRU, 2, rue Henri le Guilloux, 35033 Rennes Cedex 09, France


    Abstract
 Top
 Abstract
 Patients and methods
 Results
 Discussion
 References
 
Objectives

To evaluate the long-term functional and hemodynamic effects of right ventricular outflow tract (RVOT) pacing by comparison with right ventricular apical (RVA) pacing.

Background

Acute studies have suggested that RVOT pacing could significantly improve cardiac performance in comparison with RVA pacing but no data are available in chronically implanted patients.

Methods

Sixteen patients with chronic atrial tachyarrhythmia and complete AV block were included. Left ventricular ejection fraction (LVEF) was ≥40% in ten and <40% in six. Patients were implanted with a standard DDDR pacemaker connected to two ventricular leads. A screw-in lead was placed at the RVOT and connected to the atrial port. A second lead was positioned at the RVA and connected to the ventricular port. Right ventricular outflow tract and RVA pacing was achieved by programming either the AAIR or the VVIR mode respectively. Four months later patients were randomized so as to undergo either RVOT or RVA pacing for three months according to a blind crossover protocol. Apart from the pacing mode, programming remained unchanged throughout the study. At the end of each period, NYHA class, LVEF, exercise time and maximal oxygen uptake were assessed.

Results

No significant difference was observed between the two modes for all the parameters analyzed. These identical results were observed in all patients globally, in patients with LVEF ≥40% as in those with LVEF <40%.

Conclusions

Within the limits of this study, no symptomatic improvement or hemodynamic benefit was noted after three months of RVOT pacing, by comparison with RVA pacing.

Abbreviations and Acronyms
  AV = atrioventricular
  CO = cardiac output
  LVEF = left ventricular ejection fraction
  NYHA = New York Heart Association
  RVA = right ventricular apex
  RVOT = right ventricular outflow tract
  VVIR-RVA pacing = single site right ventricular apical pacing
  VVIR-RVOT pacing = single site right ventricular outflow tract pacing


One of the main objectives of modern cardiac pacing is to optimize, or at least to stabilize, cardiac performance which is dependent on three main parameters: chronotropic function, quality of AV synchrony when applicable and ventricular activation sequence in relation to the site selected for implanting the ventricular lead. For 35 years, the right ventricular apex (RVA) has been the elective pacing site (1). Experimental (2,3) and clinical studies (4,5), however,

suggest that this site is not optimal in terms of cardiac function. Other sites have recently been proposed for right ventricular implantation: right ventricular outflow tract (RVOT), either septal (6) or in the right ventricular free wall (7,8), and the His-bundle area (9,10). Among these alternative sites, only RVOT was evaluated for feasibility and safety using chronically implanted screw-in leads (11).

Results of acute hemodynamic studies, although controversial (12), have shown increased cardiac output as a result of RVOT pacing, relatively to RVA pacing (7,8). Some authors therefore have hypothesized that RVOT could become the elective site for ventricular pacing (13), subject to obtaining positive results from chronic comparative assessments.

The aim of this study was to evaluate the long-term effects of RVOT pacing and of RVA pacing on symptoms, exercise tolerance and left ventricular function in an intra-patient comparison.


    Patients and methods
 Top
 Abstract
 Patients and methods
 Results
 Discussion
 References
 
The inclusion criteria were: first, the existence of a chronic atrial tachyarrhythmia, to rule out any potential hemodynamic influence of the atrial systole and any further need to optimize AV delay in case of dual chamber pacing. Second, the existence of a complete AV block, either spontaneous or induced by radiofrequency ablation of the AV junction, to ensure permanent and complete ventricular capture during pacing. Third, the possibility for each patient to perform an exercise test. All patients gave their informed consent and the study protocol was approved by the local ethics committee.

Pacing configuration.   Two ventricular leads were implanted in each patient. A passive lead (any commercially available lead could be used) was conventionally placed at the RVA. A screw-in lead (any commercially available screw-in lead could be used) was implanted at the RVOT free wall, as shown in Figure 1. The positions of the leads were controlled by fluoroscopy and surface ECG confirmed QRS axis normalization (0 to 90°) during RVOT pacing. The two ventricular leads were connected to a conventional DDDR pacemaker (Medtronic Elite or Thera DR, Medtronic Inc, Minneapolis, Minnesota). The RVA lead was connected to the ventricular port and the RVOT lead to the atrial port. Single site right ventricular apical programming thus provided single site VVIR pacing at the apex and AAIR programming ensured single site VVIR pacing at the RVOT. DDDR programming with the shortest programmable AV delay value (30 ms) provided dual site right ventricular and almost simultaneous pacing. The lower and upper rate limits were individually programmed depending on the estimated needs in each patient. The lower rate limit was set between 60 and 75 bpm and the upper rate limit from 120 to 140 bpm. However, the programmed values of lower and upper rate limits remained unchanged all along the study. The activity response curve (sensor) was programmed and set at "7" in all patients. Finally the sensitivity on the atrial channel (connected to the RVOT lead) was set at a low value (2 mV) in order to prevent the potential risk of cross-talk and of pacemaker mediated tachycardia, during the "wash-in" period with the pacemaker programmed in the DDDR mode with a short AV delay.



View larger version (64K):
[in this window]
[in a new window]
 
Figure 1 Chest X ray, (A) frontal and (B) sagittal projections showing the position of the two ventricular leads: the passive lead at the right ventricular apex and the screw-in lead at the RVOT free wall.

 
Study design.   Because all patients presented with chronic atrial tachyarrhythmia at inclusion and because ventricular rate control was achieved by AV junction ablation, the crossover study only started four months later to rule out any hemodynamic improvement that could potentially be due to the regression of a tachycardia-induced cardiomyopathy. During the first four months, the pacemaker was programmed in the DDDR mode. This "wash-in" period was used to clear any carry-on effect of the pacing site during the crossover study. The crossover study included two periods of three months each, randomized as single site VVIR-RVA or single site VVIR-RVOT mode. Throughout the crossover study, the pacing parameters remained unchanged, resting and maximal heart rate and sensor programming in particular. Patients were their own control. The physicians performing the different tests were unwise to the current programming or to the results of the preceding assessment. Pharmacological treatment remained unchanged throughout the study, especially ACE inhibitors in patients with LVEF <40%. Antiarrhythmic therapy by amiodarone was continued in only one patient because of nonsustained ventricular tachycardia.

Analyzed parameters.   At the end of each three months period spent, either in VVIR-RVA or VVIR-RVOT mode, the pacing system was verified as working well before evaluation. Lead impedence and pacing threshold were measured via telemetry on the two ventricular leads. Permanent ventricular pacing (100% paced cycles) was confirmed by pacemaker data (rate histogram) interrogation. Symptoms were evaluated by history according to the NYHA classification. QRS axis and duration were measured from a standard 12 leads surface ECG recording. Cardiac output (CO) was determined by Doppler ultrasonography (Hewlett Packard, Sonos 1000, Boston, Massachusetts, 2.5 MHz probes) (14). Left ventricular ejection fraction (LVEF) was measured at rest by radionuclide angiography (Sopha medical, DSX rectangular camera). Cardiac output and LVEF were measured at rest and at the same heart rate for each evaluation. Exercise test with oxygen consumption measurement (Eos Sprint Jaeger and Oxycon) was carried out for study requirements according to the same standardized protocol within symptom limitations, using the same equipment and under similar conditions for each evaluation. After the "wash-in" period, a run-in test in the DDDR mode was designed to familiarize the patients with the equipment and the whole procedure. Measuring oxygen consumption ensured that the test was actually maximal. Continuous ECG recording controlled that pacing was permanent with a full ventricular capture.

Statistical analysis used a nonparametric comparison. Results are expressed as mean ± standard deviation. A Kruskall and Wallis analysis of variance was performed to compare the distribution of either treatment group. When significant differences were found, a Wilcoxon signed rank test compared each pacing configuration. Each patient being their own control, a value of p < 0.05 was considered significant. Finally a Spearman rank test evaluated the correlation between the different results according to the treatment regimen.


    Results
 Top
 Abstract
 Patients and methods
 Results
 Discussion
 References
 
Patients.   Sixteen patients aged 53 to 80 (mean age 69 ± 7.5 years) were included in the study. Baseline clinical characteristics are reported in Table 1. At the end of the "wash-in" period in DDDR mode (before starting the crossover study) ten patients were in New York Heart Association (NYHA) class I, three in class II and three in class III. The mean LVEF was ≥40% in ten patients and <40% in six. Patients with LVEF <40% were significantly older and their cardiac output was significantly lower than in patients with LVEF ≥40%. Atrial fibrillation was present in 15 patients and atrial flutter was found in only one. Intrinsic ventricular conduction, as documented on the last ECG recorded before implantation, could be considered as normal in 12 patients (QRS duration ≤120 ms). Four patients had a right bundle branch block. No left bundle branch block was observed.


View this table:
[in this window]
[in a new window]
 
Table 1 Patients’ Characteristics Before Randomization

 
Implantation procedure and pacing system.   Atrioventricular junction ablation was performed in 15 patients. One patient had spontaneous complete heart block and was already implanted with a standard VVIR pacemaker. The additional RVOT lead was implanted at the time of elective pacemaker replacement. No complication linked to the pacing system was noted at implantation and throughout a mean follow-up duration of 10.4 ± 3.6 months. In particular, there was no dislodgement of RVOT leads. Chronic pacing thresholds did not differ significantly between RVA and RVOT leads (1.19 ± 1.00 V vs. 1.33 ± 1.01 V, pulse width 0.5 ms).

Analyzed parameters.   No significant difference between dual site right ventricular pacing and single site RVOT pacing was observed for the mean QRS axis (69.3 ± 38.5° vs. 85.3 ± 8.3°, p = NS) and for the paced QRS duration (163.3 ± 21.9 ms vs. 164.0 ± 18.8 ms, p = NS). However, the paced QRS morphology was clearly different in the two pacing modes, reflecting modifications in the ventricular activation sequence. Arguments concordant with a pseudofusion phenomenon due to very short (<30 ms) spontaneous conduction time from the outflow tract to the apex and resulting in effective RVOT pacing only were never observed during dual site right ventricular pacing. As could be expected, the QRS axis was significantly different during RVA pacing (–68.0 ± 16.1°, p < 0.00001). Although it was slightly longer during RVA pacing (172.0 ± 22.7 ms, p = NS), the paced QRS duration did not significantly differ.

With regard to symptoms, each patient retained their initial NYHA functional status in both pacing configurations.

Global results concerning the effects of RVA and RVOT pacing on LVEF, CO, exercise time and peak oxygen consumption are shown in Table 2. Individual changes for LVEF and CO are shown in Figures 2 and 3, respectively. Considering the patient population as a whole, no significant differences in the various parameters were noted between the two pacing configurations. Subgroup analysis produced the same results in the ten patients whose cardiac function was normal or slightly impaired, as defined by an LVEF ≥40% before the crossover study. In the patients whose LVEF was <40% before the crossover study, there was no difference either in LVEF, CO, exercise time and peak oxygen consumption, regardless of the pacing site, either RVA or RVOT.


View this table:
[in this window]
[in a new window]
 
Table 2 Results for the Principal Analyzed Parameters

 


View larger version (20K):
[in this window]
[in a new window]
 
Figure 2 Individual patient evolution for LVEF.

 


View larger version (18K):
[in this window]
[in a new window]
 
Figure 3 Individual patient evolution for cardiac output.

 

    Discussion
 Top
 Abstract
 Patients and methods
 Results
 Discussion
 References
 
This study did not elicit any difference between chronic RVA pacing and RVOT pacing in terms of NYHA classification, LVEF, cardiac output, exercise time and peak oxygen consumption. Nonetheless, the effectiveness and safety of RVOT pacing at ten months were confirmed.

Hemodynamic effects of RVA pacing.   The right ventricular apex remains the elective site for implanting permanent ventricular leads. However, by modifying the normal activation and contraction sequence, RVA pacing has been demonstrated to alter both systolic and diastolic cardiac function. In patients with normal intrinsic conduction and without structural heart disease, the effects of pacing on cardiac performance have been assessed by Rosenqvist et al. (4) and Leclercq et al. (5). In these studies atrial pacing produced a significant improvement in systolic left ventricular function as compared with atrioventricular pacing at the optimal AV delay in each patient. This benefit was observed for global and regional LVEF by radionuclide angiography (4,5), and for hemodynamics both at rest and during exercise (5). The effects on diastolic function were studied by Bedotto et al. (15) who showed significant alteration during RVA pacing in patients with low LVEF.

In patients with severe left ventricular systolic dysfunction and without conventional indication for pacing, permanent short-AV delay DDD pacing with the ventricular lead placed at the right ventricular apex was proposed as an adjunctive treatment for advanced heart failure (16,17). The clinical value of this new therapeutic approach was not confirmed in a controlled study (6). There is, however, a strong presumption of short and long term efficacy in some subgroups of patients, in particular in patients with long PR interval in spontaneous sinus rhythm (18). The results of the acute hemodynamic study by Nishimura et al. (18) clearly show that a positive response from short AV delay DDD pacing resulted from optimization in left ventricular filling by correction for mechanical AV dyssynchrony in the left heart. At that time the general view was that the potential detrimental effects of ventricular pacing at the right ventricular apex on the left ventricular function were largely counterbalanced by the benefits of extended filling time (17) in that particular subgroup of responder patients. Further studies assessed the potential interest of improving both the AV synchrony and the activation of the paced ventricle. A first attempt in this way consisted in pacing the right ventricle at alternative sites, especially the RVOT or the septal wall. Multisite biventricular pacing (19,20) and single site left ventricular pacing (21) were recently introduced and provided encouraging results during acute studies with temporary pacing. These new pacing techniques are now under evaluation.

Technical aspects: feasibility and safety of RVOT lead implantations.   Right ventricular outflow tract implantations were previously evaluated by Barin et al. in a randomized study (11). The implantation time was the same for RVA or RVOT leads. Pacing thresholds at one month did not differ between RVA and RVOT implantations. No lead dysfunction was noted although one lead was dislodged in the RVOT group, in a patient who presented with a "pacemaker twiddler" syndrome. In that series, as in the present series, no difference in chronic thresholds was found between RVA and RVOT after a mean follow up of 73 months. Taking Barin’s experience into account, we used screw-in leads and all implantations were successful. However, because the mechanical stresses imposed on the leads in RVOT position may be greater, a longer follow-up period will provide a better assessment of the very long-term reliability of that configuration. This also may limit the choice of other right ventricular alternative sites, for example His area pacing, in terms of safety for the patients.

QRS axis and duration.   Although it was slightly greater during RVA pacing than during RVOT pacing, QRS duration was not significantly different between the two configurations. Only the QRS axis was different between the two pacing modes. These findings are consistent with those reported by Giudici et al. (7) where RVOT pacing was sited on the free wall of the RVOT. In the series of Gold et al. (6) RVOT pacing was sited on the septal wall of the RVOT and the mean paced QRS duration was 151 ± 44 msec. In that study, although RVOT pacing was not compared with RVA pacing, it was suggested that the exact position of RVOT leads influences the QRS duration. In the studies of Buckingham et al. (12), the QRS duration was identical in RVA and RVOT pacing. Only dual site synchronous pacing (i.e., simultaneous RVA and RVOT pacing), provided thinner QRS complexes (12).

Left ventricular ejection fraction.   At the end of each crossover period no difference was found between RVA or RVOT pacing. At inclusion all patients presented with chronic atrial tachyarrhythmia. There was therefore the possibility that a "tachycardia induced cardiomyopathy" could alter cardiac performance. The "wash-in" period of dual site RVA and RVOT synchronous pacing which preceded the crossover study was thus designed to permit potential restoration of cardiac systolic function (22). In addition, if a left ventricular systolic dysfunction induced by tachycardia had persisted beyond the three months of synchronous pacing, the latest configuration studied (RVA or RVOT) would have been systematically favored. This hypothesis is unlikely because: first, there was no difference in LVEF between simultaneous stimulation, RVA and RVOT; second, the crossover was randomized and ten patients were first studied in RVA and six in RVOT. Last, the first crossover evaluations started four months after the time of ablation which appears sufficient to correct a systolic dysfunction potentially induced by tachycardia (22).

Cardiac output.   No difference was observed according to the pacing configuration in the population studied overall. The baseline LVEF did not influence that parameter in subgroup analysis. Four acute studies explored cardiac output during RVOT pacing with controversial results. In the series of Giudici et al. (7), RVOT pacing at the free wall was significantly better than RVA pacing in terms of cardiac output. That study was not randomized and it is not specified whether the physician who performed the tests was aware of the pacing mode. In any case, that study constituted the most comprehensive experiment in that field, involving 89 patients. De Cock et al. in a randomized blind acute study observed higher cardiac indexes during RVOT pacing than in RVA pacing at 85, 100 and 120 bpm in patients without structural heart disease (8). In contrast, in five out of eight patients with LVEF ≤50% or significant coronary artery disease, RVOT pacing at 120 bpm decreased cardiac index. Gold et al. compared cardiac output during RVOT DDD septal pacing in relation to intrinsic heart rate in patients whose LVEF was <30% (6). The randomized study design partially made up for the restricted number of patients. In addition, the tests were carried out without knowing the pacing mode used. In that study, no difference was noted between RVOT pacing and intrinsic heart rate. Buckingham’s study (12), which assessed cardiac output under RVA, RVOT and dual site (RVA + RVOT) pacing modes only elicited a trend in favor of simultaneous dual site right ventricular pacing.

All these studies were conducted acutely and mainly differed from ours because all patients had normal sinus rhythm or were placed in the atrium. Evaluation was conducted during ventricular asynchronous pacing (7,8), or during atrioventricular synchronous pacing with fixed (12) or variable AV delay (i.e., 100 ms to 175 ms) (6). Cowell et al. (23) noted the need for a shorter AV delay for septal right ventricular DDD pacing to be optimal as compared with apical right ventricular DDD pacing. With this optimized programming, septal short AV delay VDD pacing provided higher cardiac output as compared with spontaneous rhythm and RVA VDD pacing.

In our study, all patients presented with chronic atrial tachyarrhythmia which rules out any potential influence of the atrial systole on cardiac output and the necessity for atrioventricular optimization depending on the ventricular pacing site. Our observations therefore only apply to a purely ventricular output and should be limited to these particular patients. Nonetheless, in the present series, changing the QRS axis implicating inverted ventricular contraction sequences without modification of the QRS width did not modify cardiac performance at rest and during exercise.

Limitations of the study.   These results are to be interpreted in consideration of the small population of patients although, under the methods used, each patient was his or her own control. The pacing mode selection was randomized and the tests were conducted without knowing the programmed mode and in awareness of the results from the previous evaluation (RVA or RVOT). This small number of patients was, however, considered as relevant on the basis of a Spearman rank correlation test (r' ranging from 0.75 to 0.91).

Conclusions.   This study confirmed the reliability and safety of chronic RVOT pacing with screw-in leads, but no significant improvement in symptoms and exercise tolerance or hemodynamic benefit was noted after three months of permanent RVOT pacing, compared with RVA pacing in patients with chronic atrial tachyarrhythmia and complete heart block. The study did not bring about any fact to encourage changing the usual pacing site on the right ventricle. Finding alternative ventricular pacing sites or other configurations to optimize cardiac performance may therefore require further investigations.


    References
 Top
 Abstract
 Patients and methods
 Results
 Discussion
 References
 

  1. Furman S, Schwedel JB. An intracardiac pacemaker for Stokes-Adams seizure. N Eng J Med. 1959;261:943–948[Medline]
  2. Tyers GFO. Optimal electrode implantation site for asynchronous bipolar cardiac pacing. Ann Surg. 1968;167:168–179[Medline]
  3. Grover M, Glantz SA. Endocardial pacing site affects left ventricular end-diastolic volume and performance in the intact anesthetized dog. Circ Res. 1983;53:72–85[Abstract/Free Full Text]
  4. Rosenqvist M, Isaaz K, Botvinick EH, et al. Relative importance of activation sequence compared to atrioventricular synchrony in left ventricular function. Am J Cardiol. 1991;67:148–156[CrossRef][Medline]
  5. Leclercq C, Gras D, Le Helloco A, Nicol L, Mabo P, Daubert C. Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing. Am Heart J. 1995;129:1133–1141[CrossRef][Medline]
  6. Gold MR, Shorofsky SR, Metcalf MD, Feliciano Z, Fisher ML, Gottlieb SS. The acute hemodynamic effects of right ventricular septal pacing in patients with congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy. Am J Cardiol. 1997;79:679–681[CrossRef][Medline]
  7. Giudici M, Thornburg GA, Buck DL, et al. Comparison of right ventricular outflow tract and apical lead permanent pacing on cardiac output. Am J Cardiol. 1997;79:209–212[CrossRef][Medline]
  8. De Cock CC, Meyer A, Kamp O, Visser CA. Hemodynamic benefits of right ventricular outflow tract pacing: Comparison with right ventricular apex pacing. PACE. 1998;21:536–541
  9. Mabo P, Scherlag BJ, Munsif A, Otomo K, Lazzara R. A technique for stable His-bundle recording and pacing: electrophysiological and hemodynamic correlates. PACE. 1995;18:1894–1901
  10. Karpawich PP, Justice CD, Chang CH, Gause CY, Kuhns LR. Septal ventricular pacing in the immature canine heart: a new perspective. Am Heart J. 1991;121:827–833[CrossRef][Medline]
  11. Barin ES, Jones SM, Ward DE, Camm AJ, Nathan AW. The right ventricular outflow tract as an alternative permanent pacing site: long-term follow-up. PACE. 1991;14:3–6
  12. Buckingham TA, Candinas R, Schlapfer J, et al. Acute hemodynamic effects of atrioventricular pacing at differing sites in the right ventricle individually and simultaneously. Pace. 1997;20:909–915
  13. Sutton R. Right ventricular outflow tract pacing. Eur J C P E. 1996;6:6–7
  14. Ilhen H, Amlie JP, Dale J, et al. Determination of cardiac output by Doppler echocardiography. Br Heart. 1984;51:54–60
  15. Brignole M, Gianfranchi L, Meozzi C, et al. Influence of atrioventricular junction radiofrequency ablation in patients with chronic atrial fibrillation and flutter on quality of life and cardiac performance. Am J Cardiol. 1994;74:242–246[CrossRef][Medline]
  16. Cowell R, Morris-Thurgood J, Ilsley C, Paul V. Septal short atrioventricular delay pacing: additional hemodynamic improvements in heart failure. Pacing Clin Electrophysiol. 1994;17:1980–1983[CrossRef][Medline]
  17. Bedotto JB, Grayburn PA, Black WH, et al. Alterations in left ventricular relaxation during atrioventricular pacing in humans. J Am Coll Cardiol. 1990;15:658–664[Abstract]
  18. Hochleitner M, Hortnagl H, Choi-Keung Ng, Hortnagl M, Gschnittzer F, Zechmann W. Usefulness of physiologic dual-chamber pacing in drug resistant idiopathic dilated cardiomyopathy. Am J Cardiol. 1990;66:198–202[CrossRef][Medline]
  19. Brecker SJ, Xiao HB, Sparrow J, Gibson DJ. Effects of dual-chamber pacing with short atrioventricular delay in dilated cardiomyopathy. Lancet. 1992;340:1308–1311[CrossRef][Medline]
  20. Nishimura RA, Hayes DL, Holmes DR Jr, Tajik AJ. Mechanism of hemodynamic improvement by dual-chamber pacing for severe left ventricular dysfunction: an acute Doppler and catheterization study. J Am Coll Cardiol. 1995;25:281–288[Abstract]
  21. Cazeau S, Ritter P, Lazarus A, et al. Four-chamber pacing in dilated cardiomyopathy. PACE. 1996;19:1748–1757
  22. Leclercq C, Le Breton H, Pavin D, Victor F, Mabo P, Daubert C. Acute hemodynamic response to biventricular pacing in patients with severe congestive heart failure and without conventional indication for permanent pacemaker [abstract]. Circulation. 1997;97:I-95
  23. Blanc JJ, Etienne Y, Gilard M, et al. Evaluation of different ventricular pacing sites in patients with severe heart failure. Circulation. 1997;96:3273–3277[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
ANGIOLOGYHome page
A. S. Manolis, D. Sakellariou, and G. K. Andrikopoulos
Alternate Site Pacing in Patients at Risk for Heart Failure
Angiology, August 1, 2008; 59(2_suppl): 97S - 102S.
[Abstract] [PDF]


Home page
EuropaceHome page
A. Kypta, C. Steinwender, J. Kammler, F. Leisch, and R. Hofmann
Long-term outcomes in patients with atrioventricular block undergoing septal ventricular lead implantation compared with standard apical pacing
Europace, May 1, 2008; 10(5): 574 - 579.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Europace, October 1, 2007; 9(10): 959 - 998.
[Full Text] [PDF]


Home page
Eur Heart JHome page
Authors/Task Force Members, P. E. Vardas, A. Auricchio, J.-J. Blanc, J.-C. Daubert, H. Drexler, H. Ector, M. Gasparini, C. Linde, F. B. Morgado, et al.
Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm Association
Eur. Heart J., September 2, 2007; 28(18): 2256 - 2295.
[Full Text] [PDF]


Home page
EuropaceHome page
P. Dilaveris, A. Pantazis, G. Giannopoulos, A. Synetos, J. Gialafos, and C. Stefanadis
Upgrade to biventricular pacing in patients with pacing-induced heart failure: can resynchronization do the trick?
Europace, January 1, 2006; 8(5): 352 - 357.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Takemoto, H. Yoshimura, Y. Ohba, Y. Matsumoto, U. Yamamoto, M. Mohri, H. Yamamoto, and H. Origuchi
Radiofrequency catheter ablation of premature ventricular complexes from right ventricular outflow tract improves left ventricular dilation and clinical status in patients without structural heart disease
J. Am. Coll. Cardiol., April 19, 2005; 45(8): 1259 - 1265.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J.-B. Thambo, P. Bordachar, S. Garrigue, S. Lafitte, P. Sanders, S. Reuter, R. Girardot, D. Crepin, P. Reant, R. Roudaut, et al.
Detrimental Ventricular Remodeling in Patients With Congenital Complete Heart Block and Chronic Right Ventricular Apical Pacing
Circulation, December 21, 2004; 110(25): 3766 - 3772.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. C. Nielsen, L. Kristensen, H. R. Andersen, P. T. Mortensen, O. L. Pedersen, and A. K. Pedersen
A randomized comparison ofatrial and dual-chamber pacing in177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome
J. Am. Coll. Cardiol., August 20, 2003; 42(4): 614 - 623.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Peschar, H. de Swart, K. J. Michels, R. S. Reneman, and F. W. Prinzen
Left ventricular septal and apex pacing for optimal pump function in canine hearts
J. Am. Coll. Cardiol., April 2, 2003; 41(7): 1218 - 1226.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. C. de Cock, M. C. Giudici, and J. W. Twisk
Comparison of the haemodynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing: A quantitative review
Europace, January 1, 2003; 5(3): 275 - 278.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. Cazeau, C. Alonso, G. Jauvert, A. Lazarus, and P. Ritter
Cardiac resynchronization therapy
Europace, January 1, 2003; 5(s1): S42 - S48.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H.-F. Tse, C. Yu, K.-K. Wong, V. Tsang, Y.-L. Leung, W.-Y. Ho, and C.-P. Lau
Functional abnormalities in patients with permanent right ventricular pacing: The effect of sites of electrical stimulation
J. Am. Coll. Cardiol., October 16, 2002; 40(8): 1451 - 1458.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. Leclercq and D. A. Kass
Retiming the failing heart: principles and current clinical status of cardiac resynchronization
J. Am. Coll. Cardiol., January 16, 2002; 39(2): 194 - 201.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M. R Gold
ELECTROPHYSIOLOGY: Permanent pacing: new indications
Heart, September 1, 2001; 86(3): 355 - 360.
[Full Text] [PDF]


Home page
HeartHome page
C LECLERCQ and J-C DAUBERT
Why biventricular pacing might be of value in refractory heart failure?
Heart, August 1, 2000; 84(2): 125 - 126.
[Full Text] [PDF]


Home page
CirculationHome page
P. Deshmukh, D. A. Casavant, M. Romanyshyn, and K. Anderson
Permanent, Direct His-Bundle Pacing : A Novel Approach to Cardiac Pacing in Patients With Normal His-Purkinje Activation
Circulation, February 29, 2000; 101(8): 869 - 877.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
T. M. Kolettis, Z. S. Kyriakides, D. Tsiapras, T. Popov, I. A. Paraskevaides, and D. Th. Kremastinos
Improved Left Ventricular Relaxation During Short-term Right Ventricular Outflow Tract Compared to Apical Pacing*
Chest, January 1, 2000; 117(1): 60 - 64.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Z.I. Harris and M.D. Gammage
Alternative right ventricular pacing sites -- where are we going?
Europace, January 1, 2000; 2(2): 93 - 98.
[PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Victor, F.
Right arrow Articles by Daubert, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Victor, F.
Right arrow Articles by Daubert, C.

 
  cardiology careers collections past issues search home