J Am Coll Cardiol, 1998; 32:746-752
© 1998 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, J. L.
Right arrow Articles by Bruns, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, J. L.
Right arrow Articles by Bruns, D. E.

CLINICAL STUDIES

Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent

Results of a phase III multicenter trial1

Jerald L. Cohen, MD, FACC*, Jorge Cheirif, MD, FACC{dagger}, Douglas S. Segar, MD, FACC{ddagger}, Linda D. Gillam, MD, FACC§, John S. Gottdiener, MD, FACC||, Eva Hausnerova, MD|| and Denise E. Bruns, BS

* New Jersey VA Medical Center, East Orange, New Jersey, USA
{dagger} Ochsner Clinic, New Orleans, Louisiana, USA
{ddagger} Krannert Institute of Cardiology, Indianapolis, Indiana, USA
§ Hartford Hospital, Hartford, Connecticut, USA
|| Georgetown University Medical Center, Washington, D.C., USA
Molecular Biosystems, Inc., San Diego, California, USA

Manuscript received November 26, 1997; revised manuscript received April 30, 1998, accepted May 15, 1998.

Address for correspondence: Jerald L. Cohen, MD, Cardiology Section, New Jersey VA Medical Center, 385 Tremont Avenue, East Orange, New Jersey 07018


    Abstract
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Objectives. The echocardiographic contrast-enhancing effects and safety profile of ALBUNEX (a suspension of air-filled albumin microspheres) were compared with the new contrast agent OPTISON (formerly FS069: a suspension of albumin microspheres containing the gas perfluoropropane) in 203 patients with inadequate noncontrast echocardiograms.

Background. The efficacy of ALBUNEX has been limited by its short duration of action. By using perfluoropropane instead of air within the microsphere, its duration of action is increased.

Methods. Each patient received ALBUNEX (0.8 and 0.22 mL/kg) and OPTISON (0.2, 0.5, 3.0, and 5.0 mL) on separate days a minimum of 48 hours apart. Echocardiograms were evaluated for increase in left ventricular (LV) endocardial border length, degree of LV opacification, number of LV endocardial border segments visualized, conversion from a nondiagnostic to a diagnostic echocardiogram, and duration of contrast enhancement. A thorough safety evaluation was conducted.

Results. Compared with ALBUNEX, OPTISON more significantly improved every measure of contrast enhancement. OPTISON increased well-visualized LV endocardial border length by 6.0 ± 5.1, 6.9 ± 5.4, 7.5 ± 4.7, and 7.6 ± 4.8 cm, respectively, for each of the four doses, compared with only 2.2 ± 4.5 and 3.4 ± 4.6 cm, respectively, for the two ALBUNEX doses (p < 0.001). 100% LV opacification was achieved in 61%, 73%, 87%, and 87% of the patients with the four doses of OPTISON, but in only 16% and 36% of the patients with the two ALBUNEX doses (p < 0.001). Conversion of nondiagnostic to diagnostic echocardiograms with contrast occurred in 74% of patients with the optimal dose of OPTISON (3.0 mL) compared with only 26% with the optimal dose of ALBUNEX (0.22 mL/kg) (p < 0.001). The duration of contrast effect was also significantly greater with OPTISON than with ALBUNEX. In a subset of patients with potentially poor transpulmonary transit of contrast (patients with chronic lung disease or dilated cardiomyopathy), OPTISON more significantly improved the same measures of contrast enhancement compared with ALBUNEX and did so to the same extent as in the overall population. Side effects were similar and transient with the two agents.

Conclusion. OPTISON appears to be a safe, well-tolerated echocardiographic contrast agent that is superior to ALBUNEX.

Abbreviations and Acronyms
  ECG = electrocardiogram
  LV = left ventricular


Since its introduction, ALBUNEX has had only partial success as an echocardiographic contrast agent (1–5). Unfortunately, when given intravenously, its power to enhance left ventricular (LV) structures has been limited by its relatively short duration of action. ALBUNEX consists of microspheres prepared by the sonication of human albumin2 in the presence of air. OPTISON, formerly known as FS069, was developed to stabilize these microspheres and prolong their duration of action. To achieve this, a 1% solution of human albumin is sonicated in the presence of an inert gas, perfluoropropane. Like ALBUNEX, the product is fully manufactured and is ready for injection after simple resuspension. Preliminary studies have demonstrated the improved contrast effect and increased duration of OPTISON (6,7). We report here the first multicenter clinical trial of OPTISON. Its efficacy and safety are compared with ALBUNEX in patients with suboptimal routine echocardiograms.


    Methods
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Study design.   This study was a prospective, multicenter comparison of two intravenous echocardiographic contrast agents, ALBUNEX and OPTISON. The principal objectives of the study were to compare the contrast-induced increase in LV endocardial border delineation, degree of LV chamber opacification, number of LV endocardial border segments visualized, conversion from a nondiagnostic to diagnostic echocardiogram, and duration of contrast effect of the two agents in patients with poorly defined noncontrast echocardiograms. The safety and tolerability of the two agents were also compared.

Patient selection.   Patients were selected from those undergoing routine diagnostic echocardiography at 14 investigative sites. To be included, patients had to have poor LV endocardial border delineation, i.e., at least two of six endocardial segments in the apical four-chamber view not adequately visualized. The study was approved by the human subjects review committee at the participating institutions. Signed informed consent was obtained for each patient prior to enrollment in the study. For female patients of child-bearing potential, a negative serum pregnancy test within 24 h of testing was required. Exclusion criteria were: known or suspected hypersensitivity to blood, blood products or albumin; pregnancy or lactation; recent cerebrovascular event or transient ischemic attack within the previous 6 months; confinement to an intensive care unit or on a mechanical ventilator; New York Heart Association class IV congestive heart failure; LV ejection fraction <20%; or severe liver disease.

From this study population, a subgroup of patients was identified who had dilated cardiomyopathy or chronic pulmonary disease, conditions known to impair the transpulmonary transit of echo contrast agents. The study design required that 25% of the patients enrolled fall into this subgroup. Patients in this impaired function group were those with an LV ejection fraction of 20–40% or a history of clinically significant asthma, chronic bronchitis, emphysema, bronchiectasis, or pulmonary hypertension. The demonstration of safety of new contrast agents is important in this population. There are theoretical concerns about pulmonary microcirculatory compromise with echo contrast agents in these patients.

Contrast agents.   ALBUNEX is a suspension of air-filled microspheres with a mean concentration of 3.0–5.0 x 108 microspheres/mL and a mean diameter of 3.0–5.0 µm. OPTISON is a suspension of perfluoropropane-filled albumin microspheres with a mean concentration of 5.0–8.0 x 108 microspheres/mL and a mean diameter of 2.0–4.5 µm. Like ALBUNEX, OPTISON is completely manufactured and is prepared for injection by rotating the vial for a few seconds. Each patient received ALBUNEX and OPTISON on separate days at least 48 h apart. The sequence of contrast administration was randomized: half of the patients received ALBUNEX and half received OPTISON on the first test session.

Two-dimensional echocardiography.   Standard, continuous, fundamental, two-dimensional echocardiography was used. Prior to baseline imaging, ultrasound settings for each patient were optimized for the apical four-chamber view with the assistance of a grey-scale phantom (ATS Laboratories, Inc.). Once the clearest image of the phantom was obtained, the ultrasound settings for each patient were maintained throughout the testing sessions. For ALBUNEX, the apical four-chamber view was utilized. If feasible, the apical two-chamber and parasternal short axis and long axis views were also obtained after contrast injection. For OPTISON, the apical four-chamber, apical two-chamber, and parasternal short and long axis views were used throughout. All imaging was recorded on videotape (Fig. 1).



View larger version (67K):
[in this window]
[in a new window]
 
Figure 1 Apical four-chamber views (end-diastole on left, end-systole on right) from a single patient. Top, Before contrast, there is poor LV endocardial border definition. Middle, After injection of 0.22 mg/kg of ALBUNEX, there is minimal improvement in LV endocardial border delineation and faint LV chamber opacification in diastole. In systole, there is almost no contrast effect. Bottom, After injection of 0.5 mL of OPTISON, there is 100% LV chamber opacification and almost complete endocardial border delineation in both diastole and systole.

 
Image analysis.   Echocardiograms were reviewed by a central core laboratory (Georgetown University Medical Center) blinded to patient history, contrast agent, and dose. All observations were made at baseline and after each dose of OPTISON and ALBUNEX following clearance of attenuation. LV endocardial border length, endocardial border delineation by segment, LV opacification, and diagnostic yield were the parameters assessed in a blinded manner by the core lab and are reported below. With the exception of LV endocardial border length and diagnostic yield, each observation was also made by the individual investigators in an unblinded manner for comparison purposes. The duration of contrast effect was assessed by the investigators only and is reported below.

LV endocardial border length
The apical four-chamber view was digitized off-line by a commercially available imaging system (Nova Microsonics Image Vue). Endocardial length was obtained by measuring and summing those segments that were well visualized. The increase in well-visualized endocardial border length due to each agent dose compared with noncontrast was calculated for systole and diastole.

LV endocardial border delineation by segment
The apical four-chamber view was divided into six segments. Each segment was graded visually from the videotape. A qualitative scale was used as follows: A = not well delineated; B = average delineation; C = good delineation; and D = excellent delineation. The proportion of patients whose endocardial delineation improved ≥1 segment at end-diastole (from grade A to grade B, C or D) was calculated for each agent dose.

LV chamber opacification
Visual assessment from the videotape images of LV peak filling was graded according to the following qualitative scale: 0 = none (0% LV filling); 1 = faint contrast (33% LV filling); 2 = intermediate filling (67% LV filling); and 3 = full LV chamber opacification (100% LV filling). The proportion of patients with each grade of LV filling was calculated for each agent and dose, at systole, and diastole.

Duration of contrast
From the imaging protocol, each investigator was asked to calculate the duration of clinically useful contrast effect for each agent dose.

Diagnostic yield
The rate of conversion from a nondiagnostic to a diagnostic echocardiogram with contrast was assessed. Patients were considered to have a nondiagnostic noncontrast echocardiogram if the apical four-chamber view had a minimum of four of six segments graded as "A" (not well visualized) at end-diastole. Studies were determined to have become diagnostic after contrast if they improved to five or six segments judged as visualized (graded as B, C, or D).

Safety and tolerability.   At the time of enrollment into the study, a detailed clinical history was obtained from each patient. A physical examination, 12-lead electrocardiogram (ECG), vital signs, urinalysis, creatine phosphokinase isoenzymes, chemistry panel, complete blood count, prothrombin, and partial thromboplastin times were also obtained. These parameters, along with symptom notation, were repeated after each set of contrast agent administrations and again at 48 h poststudy. Throughout each testing session, oxygen saturation, vital signs, and ECG rhythm recordings were made. The onset, severity, duration of adverse events, and their possible relationship to each agent were noted.

Statistical analysis.   LV endocardial border length was analyzed as a two-way ANOVA with factors of protocol and agent/dose level. Tukey-adjusted contrasts on comparisons between the two ALBUNEX doses and all four OPTISON doses were performed. Proportion of patients converting from nondiagnostic to diagnostic, improving in one or more segments, with >67% filling and with >100% LV filling were all analyzed by Chi-square test. Since these were all highly statistically significant (p < 0.001 for all), pair-wise comparisons between the two ALBUNEX doses and all four OPTISON doses were made with Fisher’s exact tests and a Bonferroni correction. For each parameter reported, the sample size varied slightly. This occurred because either the baseline or contrast image could not be read due to poor image quality or technical errors in image acquisition. Data are reported as mean ± standard deviation or number and percent of patients, and represent the core lab analysis unless otherwise stated.


    Results
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
Patient population.   A total of 203 patients were enrolled in the study (Table 1). Of these, 74 (37%) had either dilated cardiomyopathy or chronic lung disease (impaired function group). Seven patients received only one contrast agent. Three patients received OPTISON on the first day but did not return for ALBUNEX on the second day: one for bad weather conditions, another withdrew without a reason, and one withdrew on the advice of a family member. Four patients received ALBUNEX on the first day but did not return for OPTISON on the second day: one for intravenous access problems, one for chest pain the evening after ALBUNEX injection, one for pneumonia complicating chronic lung disease 48 h after receiving ALBUNEX, and another for emergency coronary bypass surgery 5 d after ALBUNEX administration. None of these problems were considered related to ALBUNEX by the investigators.


View this table:
[in this window]
[in a new window]
 
Table 1 Patient Characteristics (n = 203)

 
LV endocardial border length.   For all patients, the increase in LV endocardial border length at end-diastole (Fig. 2A) was greater with each dose of OPTISON (6.0 ± 5.1, 6.9 ± 5.4, 7.5 ± 4.7, 7.6 ± 4.8 cm) than with each dose of ALBUNEX (2.2 ± 4.5, 3.4 ± 4.6 cm), p < 0.001. Similarly, in the impaired function group, end-diastolic LV endocardial border length increased more with each OPTISON dose (6.2 ± 5.4, 6.6 ± 6.7, 7.8 ± 5.4, 8.0 ± 5.4 cm) than with each ALBUNEX dose (1.2 ± 4.5, 2.8 ± 4.4 cm), p < 0.001. End-systolic increases in LV endocardial border length for all patients (Fig. 2B) were also greater with each dose of OPTISON (3.5 ± 4.6, 4.5 ± 4.9, 4.8 ± 4.6, 5.4 ± 4.6 cm) than for each dose of ALBUNEX (0.8 ± 3.8, 1.4 ± 3.8), p < 0.001. Again, in the impaired function group, end-systolic LV endocardial border length increased more with OPTISON (3.8 ± 5.0, 5.2 ± 5.8, 5.1 ± 5.2, 6.7 ± 4.7 cm) than with ALBUNEX (0.5 ± 3.9, 1.6 ± 4.0 cm) p < 0.001.



View larger version (33K):
[in this window]
[in a new window]
 
Figure 2 A, Increase in LV endocardial border length at end-diastole after the two doses of ALBUNEX (ALB) and the four doses of OPTISON (OPT). Open bars, all patients; filled bars, impaired function group. Doses of ALBUNEX in mL/kg, OPTISON in mL. *p < 0.001 for each dose of OPTISON versus each dose of ALBUNEX. B, Increase in LV endocardial border length at end-systole. Abbreviations and symbols as in A.

 
LV endocardial delineation by segment.   When endocardial delineation was evaluated by segment, the percentage of all patients improving by ≥1 segment was higher for each dose of OPTISON (81% [154/191], 90% [172/192], 93% [177/190], 94% [174/186]) than for either dose of ALBUNEX (64% [124/195], 74% [142/193]), p < 0.001. In the impaired function group, improvement in segment delineation was noted in more OPTISON patients (74% [51/69], 87% [61/70], 94% [65/69], 94% [62/66]) than in ALBUNEX patients (59% [41/70], 77% [54/70]), p < 0.001 for each comparison except for ALBUNEX 0.08 mL/kg versus OPTISON 0.2 mL, p < 0.01; ALBUNEX 0.22 mL/kg versus OPTISON 0.2 mL, p = NS; ALBUNEX 0.22 mL/kg versus OPTISON 0.5 mL, p < 0.01.

LV opacification of 100%.   Full LV opacification at end-diastole (Fig. 3A) was achieved by a greater percentage of all patients with each of the four doses of OPTISON (61% [112/183], 73% [133/181], 87% [158/181], 87% [89/102]) than with each of the two doses of ALBUNEX (16% [16/100], 36% [68/187]), p < 0.001. Similarly, in the impaired function group, a higher proportion of patients with OPTISON (58% [40/69], 71% [46/65], 87% [59/68], 83% [30/36]) attained complete LV opacification compared with ALBUNEX (5% [2/37], 20% [14/71]), p < 0.001. At end-systole (Fig. 3B), OPTISON again produced full LV opacification in a higher percentage of all patients (48% [87/183], 59% [107/181], 69% [125/181], 75% [77/102]) than did ALBUNEX (7% [7/100], 9% [16/187]), p < 0.001. In the impaired function group, OPTISON also achieved complete LV opacification in more patients (46% [32/69], 62% [40/65], 79% [54/68], 75% [27/36]) than did ALBUNEX (3% [1/37], 4% [3/71]), p < 0.001.



View larger version (33K):
[in this window]
[in a new window]
 
Figure 3 A, 100% LV opacification at end-diastole. Pts, Patients. Other abbreviations and symbols as in Figure 2A. B, 100% LV opacification at end-systole. Abbreviations and symbols as in Figures 2A and 3A.

 
LV opacification of ≥67%.   This level of LV opacification at end-diastole (Fig. 4A) was achieved in a higher percentage of all patients with each of the four doses of OPTISON (81% [148/183], 90% [163/181], 94% [171/181], 95% [97/102]) than with either of the two doses of ALBUNEX (41% [41/100], 56% [104/187]), p < 0.001. Similarly, in the impaired function group, a higher proportion of patients with OPTISON (72% [50/69], 85% [55/65], 94% [64/68], 94% [34/36]) attained this degree of LV opacification compared with ALBUNEX (27% [10/37], 35% [25/71]), p < 0.001. At end-systole (Fig. 4B), OPTISON produced this level of LV opacification in a higher percentage of all patients (60% [110/183], 73% [133/181], 81% [147/181], 83% [85/102]) than did ALBUNEX (10% [10/100], 14% [26/187]), p < 0.001. In the impaired function group, OPTISON attained this degree of LV opacification in more patients (58% [40/69], 74% [48/65], 85% [58/68], 81% [29/36]) than did ALBUNEX (5% [2/37], 7% [5/71]), p < 0.001.



View larger version (36K):
[in this window]
[in a new window]
 
Figure 4 A, ≥67% LV opacification at end-diastole. Abbreviations and symbols as in Figure 2A and 3A. B, ≥67% LV opacification at end-systole. Abbreviations and symbols as in Figure 2A and 3A.

 
Diagnostic yield.   The rate of conversion from a nondiagnostic to a diagnostic echocardiogram was evaluated with each dose of contrast agent judged to be the most efficacious (3.0 mL with OPTISON and 0.22 mL/kg with ALBUNEX) based on the endocardial border length and LV opacification analyses. The core laboratory identified 85 OPTISON patients and 85 ALBUNEX patients who were considered to have nondiagnostic baseline studies. Among all patients, a higher percentage of the OPTISON studies (74%, 63/85) converted to diagnostic echocardiograms compared with ALBUNEX (26%, 22/85), p < 0.001. Similarly, in the impaired function patients, there were more conversions with OPTISON (75%, 30/40) than with ALBUNEX (12%, 5/41), p < 0.001.

Duration of contrast.   The duration of clinically useful contrast effect was greater for all patients with each dose of OPTISON (1.7 ± 1.3, 2.4 ± 1.8, 4.3 ± 2.5, and 5.2 ± 3.3 min) than with each dose of ALBUNEX (0.6 ± 0.6 and 0.8 ± 0.7 min), p < 0.001.

Investigators’ assessments.   Left ventricular opacification and LV endocardial delineation by segment were evaluated by the investigators as well as the core lab. The investigators’ assessments related closely to those of the core lab. In response to the questionnaire regarding diagnostic confidence, investigators thought ALBUNEX produced a diagnostic study in 45% (92/203) of patients, whereas OPTISON was thought to produce a diagnostic study in 87% (176/203). Overall, investigators preferred OPTISON over ALBUNEX in 97% (184/203) of patients.

Side effects.   Among all patients, there were no clinically significant changes in physical examination, vital signs, or ECG with either OPTISON or ALBUNEX. In particular, there were no significant changes in the heart rate, blood pressure, or oxygen saturation in the impaired function group. Five patients had mild decreases in oxygen saturation (mean decrease 8.0 ± 0.7%): four with OPTISON and one with ALBUNEX. These episodes were asymptomatic, transient, and resolved spontaneously. Side effects believed to be related to each agent are shown in Table 2. There were no significant differences in side effects between the two agents. None required treatment.


View this table:
[in this window]
[in a new window]
 
Table 2 Side Effects Considered to Be Agent Related

 

    Discussion
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
This is the first multicenter clinical trial of OPTISON, a new generation echocardiographic contrast agent. Its superiority over ALBUNEX was demonstrated with continuous, fundamental imaging.

Characteristics of OPTISON.   While ALBUNEX has achieved some success as an ultrasound contrast agent (1–5), its clinical usefulness has been limited by its relatively short duration of contrast effect. ALBUNEX consists of albumin microspheres filled with air, which in turn consists mainly of oxygen and nitrogen. Graham’s Law states that the rate of diffusion of gases is inversely proportional to the square root of their molecular weights (8). Because oxygen and nitrogen have low molecular weights (32 and 28 g/mol, respectively), they easily diffuse out of the albumin microspheres. They are also readily soluble in blood, another factor causing them to escape from the microspheres. As the gases escape, the microspheres become smaller. As particle size is the principal determinant of ultrasound backscatter (9), the contrast effect diminishes as microsphere size decreases. To obviate this, gases with less diffusivity and less solubility in blood have been explored for use with contrast agents (10,11). OPTISON is produced by the sonication of a 1% solution of human albumin in the presence of perfluoropropane, an inert gas approved by the FDA for use in ophthalmologic surgery (12). Its high molecular weight (188 g/mol) makes it less diffusable than air. It is also less soluble in blood. This significantly stabilizes microsphere size. As a result, more microspheres survive the transit through the pulmonary circulation for delivery to the left heart. In addition, higher concentrations of microspheres in itself is protective against destruction by ultrasound (13–15). The higher concentration of microspheres reaching the left heart is responsible for the increased contrast effect of OPTISON.

Efficacy.   For all patients, OPTISON was significantly superior to ALBUNEX in all measures of contrast enhancement, including increase in LV endocardial border length, LV opacification, endocardial segment delineation, diagnostic yield, and duration of contrast. It should be emphasized that the patients in this study had incomplete endocardial depiction on their routine echocardiograms. Despite selecting only patients with technically difficult images, OPTISON was able to improve LV opacification such that 87% of patients had 100% LV opacification at end-diastole. This degree of LV filling with OPTISON occurred in over three times the number of patients compared with ALBUNEX. As a result of improved endocardial border delineation and LV opacification, the investigators reported a greater sense of diagnostic confidence with OPTISON than with ALBUNEX.

Impaired function group.   It has been shown previously that patients with reduced forward cardiac output, such as those with LV systolic dysfunction or pulmonary hypertension, have diminished LV opacification with ALBUNEX (16,17). It has been proposed that the reduced cardiac output causes a delay in the transpulmonary transit of contrast. This causes prolonged exposure of the microspheres to ultrasound and ultrasound-induced microsphere destruction as well as more time for diffusion of gas out of the microspheres with consequent microsphere shrinkage (16,17).

In the present study, 74 patients had chronic lung disease or dilated cardiomyopathy. As expected, there was decreased contrast effect with ALBUNEX in these patients. OPTISON, however, maintained its contrast effect in this subgroup. In fact, there was a trend toward increased LV endocardial border delineation and opacification, especially in systole, with OPTISON in this group compared with all patients (Figs. 2–4). Therefore, the greatest effects of OPTISON were in those patients in whom contrast echocardiography would have benefited the most. These patients typically have the poorest quality echocardiograms. One may surmise that the preservation of bubble size and concentration due to perfluoropropane in OPTISON resists the destruction of microspheres by ultrasound energy in these patients.

Systole versus diastole.   It is well known that the contrast effects of ALBUNEX are significantly reduced during systole (18). This was observed in the present study (Figs. 2–4). While this phenomenon has been actively investigated, the precise mechanism has not been clearly defined. Microsphere destruction or compression during the high LV pressures of systole have been implicated (18–20). The contrast effect of OPTISON did decrease somewhat during systole in the present trial but to a much lesser extent than ALBUNEX (Figs. 2–4). The higher concentration of microspheres delivered to the left ventricle must in some way counteract the effects of systolic pressures (14).

Side effects.   The side effects of ALBUNEX have been well studied (2–5). Altered taste sensation has been the most common symptom. Similar side effects were noted with ALBUNEX in the present study. In this and in previous studies, side effects were mild, transient, and required no treatment (2–5). The absence of significant side effects with ALBUNEX may be due, in part, to its lack of hemodynamic alterations. In several studies, ALBUNEX did not change right- and left-sided cardiac pressures, LV contractility, or blood gases (13,17,21).

In the present investigation, the side effects observed with OPTISON were similar and occurred with the same frequency as with ALBUNEX. All were mild and resolved spontaneously. OPTISON was also well tolerated in another study of patients with coronary artery disease (6). As with ALBUNEX, OPTISON has been shown not to alter pulmonary and left heart pressures, LV contractility, myocardial blood flow, and blood gases (7,21,22). In the subgroup of patients in our study with pulmonary and/or cardiac dysfunction, the frequency of side effects was low. This observation is particularly important because of the theoretical concern that these patients are prone to pulmonary microcirculatory embarrassment after injection of microspheres. In fact, some studies of ultrasound contrast agents under development have specifically avoided patients with pulmonary disease (23). We conclude that the safety profile of OPTISON is excellent and equivalent to that of ALBUNEX.

Limitations of study.   The true duration of OPTISON was underestimated in this study. Investigators were not specifically asked to determine its actual duration. When protocol imaging was complete, no further evaluations were made, even though OPTISON was still present on the echocardiogram. Neither harmonic nor intermittent imaging was employed. These techniques have been shown to enhance the contrast effects of ultrasound contrast agents and have great promise for the future (24,25).

Conclusions.   OPTISON is an excellent contrast agent that is superior to ALBUNEX for LV endocardial border delineation and opacification. The safety profile of OPTISON is equal to that of ALBUNEX in both a general population of patients and in those with cardiac and/or pulmonary dysfunction.


    Acknowledgments
 
We are indebted to Mrs. Tracy Banks for her secretarial assistance.


    Footnotes
 
This work was supported by Molecular Biosystems, Inc., San Diego, California.

1 Principal Investigators for the OPTISON Multicenter Trial: David S. Bach, MD, University of Michigan Medical Center, Ann Arbor, MI; Jorge Cheirif, MD, Ochsner Heart and Vascular Institute, New Orleans, LA; Jerald L. Cohen, MD, New Jersey VA Medical Center, East Orange, NJ; Linda J. Crouse, MD, Mid-America Cardiology Associates, Kansas City, MO; John Dent, MD, University of Virginia Medical Center, Charlottesville, VA; Candace Dick, MD, Hennipin County Medical Center, Minneapolis, MN; Samer Ellahham, MD, Back

2 Washington Hospital Center, Washington, DC; Steven Feinstein, MD, University of Illinois at Chicago, Chicago, IL; Linda D. Gillam, MD, Hartford Hospital, Hartford, CT; Michael H. Picard, MD, Massachusetts General Hospital, Boston, MA; Gary D. Plotnick, MD, University of Maryland Hospital, Baltimore, MD; Charles Pollick, MD, The Heart Institute, Good Samaritan Hospital, Los Angeles, CA; Douglas Segar, MD, Krannert Institute of Cardiology, Indianapolis, IN; Miguel Zabalgoitia, MD, University of Texas Health Science Center at San Antonio, San Antonio, TX; Echocardiography Core Laboratory: John S. Gottdiener, MD, and Eva Hausnerova, MD, Georgetown University Medical Center, Washington, D.C. Back


    References
 Top
 Abstract
 Methods
 Results
 Discussion
 References
 
1. Christiansen C, Kryvi H, Sontum PC, Skotland TL. Physical and biochemical characterization of Albunex, a new ultrasound contrast agent consisting of air-filled albumin microspheres suspended in a solution of human albumin. Biotechnol Appl Biochem. 1994;19:307–320

2. Crouse LJ, Cheirif J, Hanly DE, et al. Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the phase III Albunex multicenter trial. J Am Coll Cardiol. 1993;22:1494–1500[Abstract]

3. Feinstein SB, Cheirif J, Ten Cate FJ, et al. Safety and efficacy of a new transpulmonary ultrasound contrast agent: initial multicenter clinical results. J Am Coll Cardiol. 1990;16:316–324[Abstract]

4. Geny B, Mettauer B, Muan B, et al. Safety and efficacy of a new transpulmonary echo contrast agent in echocardiographic studies in patients. J Am Coll Cardiol. 1990;22:1193–1198

5. Keller MW, Glasheen W, Kaul S. Albunex: a safe and effective commercially produced agent for myocardial contrast echocardiography. J Am Soc Echocardiogr. 1989;2:48–52[Medline]

6. Al-Mansour HA, Pumper GM, Foley DA, Kukuzke JA, Mulvagh SL. Is harmonic contrast echocardiography the procedure of choice for optimal endocardial border definition [abstr]? J Am Soc Echocardiogr. 1998;11:527

7. Meza M, Greener Y, Hunt R, et al. Myocardial contrast echocardiography: reliable, safe and efficacious myocardial perfusion assessment after intravenous injection of a new echocardiographic contrast agent. Am Heart J. 1996;132:871–881[CrossRef][Medline]

8. Nebergall WH, Schmidt FC, Holtzclaw HF. College Chemistry with Quantitative Analysis. Lexington, MA: DC Heath; 1976. p. 706

9. Albers VM. Underwater Acoustic Handbook. Hershey, PA: Pennsylvania State University Press; 1960.

10. Swanson DP. Enhancement agents for ultrasound: fundamentals. Swanson DP, Chilton HM, Thrall JH. Pharmaceuticals in Medical Imaging. New York, NY: Macmillan Publishing Co; 1990. p. 682–687

11. Mattrey RF. The potential role of perfluorochemicals (PFC’s) in diagnostic imaging. Art Cells Blood Subs Immob Biotech. 1994;22:295–313[Medline]

12. Wong RF, Thompson JT. Prediction of the kinetics of disappearance of sulfur hexafluoride and perfluoropropane intraocular gas bubbles. Ophthalmology. 1988;95:609–613[Medline]

13. Walker R, Wiencek JG, Aronson S, et al. The influence of intravenous ALBUNEX® injections on pulmonary arterial pressure, gas exchange and left ventricular peak intensity. J Am Soc Echocardiogr. 1992;5:463–470[Medline]

14. Wiencek JG, Feinstein SB, Walker R, Aronson S. Pitfalls in quantitative contrast echocardiography: the steps to quantitation of perfusion. J Am Soc Echocardiogr. 1993;6:395–416[Medline]

15. Ota T, Hillman ND, Craig D, Kisslo J, Smith PK. Contrast echocardiography: influence of ultrasonic machine settings, mixing condition and pressurization on pixel intensity and microsphere size of Albunex solutions in vitro. J Am Soc Echocardiogr. 1997;10:31–40[CrossRef][Medline]

16. Gandhok NK, Block R, Ostoic T, et al. Reduced forward output states affect the left ventricular opacification of intravenously administered ALBUNEX®. J Am Soc Echocardiogr. 1997;10:25–30[CrossRef][Medline]

17. Zotz RJ, Genth S, Mitrovic V, et al. The influence of Albunex on the pulmonary circulation in patients with pulmonary hypertension or left heart failure. Eur Heart J. 1996;17:302–307[Abstract/Free Full Text]

18. Tiukinhoy S, Bhoopalam S, Winkelmann JW, et al. Loss of contrast intensity during systole in the left ventricular cavity with the use of the contrast agent ALBUNEX®: an analysis of its correlation’s with pressure and velocity. Invest Radiology. 1996;31:415–422[CrossRef]

19. Mor-Avi V, Shroff SG, Robinson KA, et al. Effects of left ventricular pressure on sonicated albumin microbubbles: evaluation using an isolated rabbit heart model. J Am Coll Cardiol. 1994;24:1779–1785[Abstract]

20. Vuille C, Nidorf M, Morissey RL, Newell JB, Weyman AE, Picard MH. Effect of static pressure on the disappearance rate of specific echocardiographic contrast agents. J Am Soc Echocardiogr. 1994;7:347–354[Medline]

21. Mor-Avi V, Shroff SG, Robinson KA, Cholley BP, Ng AF, Lang RM. Echocardiographic contrast agents and left ventricular contractility: evaluation using an isolated rabbit heart model. J Am Soc Echocardiogr. 1996;9:452–461[CrossRef][Medline]

22. Skyba DM, Camarano G, Goodman NC, et al. Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection. J Am Coll Cardiol. 1996;28:1292–1300[Abstract]

23. Hundley WG, Kizilbash A, Afridi I, Franco F, Peshock RM, Grayburn PA. Intravenous dodecafluoropentane improves determination of left ventricular function during transthoracic echocardiography. J Am Coll Cardiol. 1997;29:520 (Abstr)

24. Burns PN. Harmonic imaging with ultrasound contrast agents. Clin Radiol. 1996;51(Suppl 1):50–55[Medline]

25. Wei K, Skyba DM, Firschke C, et al. Interactions between microbubbles and ultrasound: in vitro and in vivo observations. J Am Coll Cardiol. 1997;29:1081–1088[Abstract]




This article has been cited by other articles:


Home page
ODR CardiologyHome page
G. Y. H. Lip, H.-F. Tse, and A. J. Stewart Coats
Echocardiography
ODR Cardiology, January 1, 2011; 1(1): med-9780199568093-div1-00 - med-9780199568093-div1-00.
[Full Text]


Home page
J Am Coll Cardiol ImgHome page
N. S. Chahal and R. Senior
Clinical Applications of Left Ventricular Opacification
J. Am. Coll. Cardiol. Img., February 1, 2010; 3(2): 188 - 196.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S A Mollema, G Nucifora, and J J Bax
Prognostic value of echocardiography after acute myocardial infarction
Heart, November 1, 2009; 95(21): 1732 - 1745.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
S. S. Abdelmoneim, M. Bernier, C. G. Scott, A. Dhoble, S. A. C. Ness, M. E. Hagen, S. Moir, R. B. McCully, P. A. Pellikka, and S. L. Mulvagh
Safety of Contrast Agent Use During Stress Echocardiography: A 4-Year Experience From a Single-Center Cohort Study of 26,774 Patients
J. Am. Coll. Cardiol. Img., September 1, 2009; 2(9): 1048 - 1056.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
R. Senior, H. Becher, M. Monaghan, L. Agati, J. Zamorano, J. L. Vanoverschelde, and P. Nihoyannopoulos
Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography
Eur Heart J Cardiovasc Imaging, March 1, 2009; 10(2): 194 - 212.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. S. Dolan, S. S. Gala, S. Dodla, S. S. Abdelmoneim, F. Xie, D. Cloutier, M. Bierig, S. L. Mulvagh, T. R. Porter, and A. J. Labovitz
Safety and Efficacy of Commercially Available Ultrasound Contrast Agents for Rest and Stress Echocardiography: A Multicenter Experience
J. Am. Coll. Cardiol., January 6, 2009; 53(1): 32 - 38.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. L. Main, J. H. Goldman, and P. A. Grayburn
Thinking Outside the "Box" The Ultrasound Contrast Controversy
J. Am. Coll. Cardiol., December 18, 2007; 50(25): 2434 - 2437.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
R. Olszewski, J. Timperley, S. Cezary, M. Monaghan, P. Nihoyannopoulis, R. Senior, and H. Becher
The clinical applications of contrast echocardiography
Eur Heart J Cardiovasc Imaging, June 1, 2007; 8(3): s13 - s23.
[Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
T. Geisler, H.C. Rost, P.S. Wild, and R. Zotz
Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565
Eur Heart J Cardiovasc Imaging, January 1, 2007; 8(1): 19 - 29.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
G. A. Whalley, G. D. Gamble, H. J. Walsh, N. Sharpe, and R. N. Doughty
Quantitative evaluation of regional endocardial visualisation with second harmonic imaging and contrast left ventricular opacification in heart failure patients
Eur Heart J Cardiovasc Imaging, March 1, 2005; 6(2): 134 - 143.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
H Becher, J Chambers, K Fox, R Jones, G J Leech, N Masani, M Monaghan, R More, P Nihoyannopoulos, H Rimington, et al.
BSE procedure guidelines for the clinical application of stress echocardiography, recommendations for performance and interpretation of stress echocardiography: A report of the British Society of Echocardiography Policy Committee
Heart, December 1, 2004; 90(suppl_6): vi23 - vi30.
[Full Text] [PDF]


Home page
RadiologyHome page
Y. Kono, S. P. Pinnell, C. B. Sirlin, S. R. Sparks, B. Georgy, W. Wong, and R. F. Mattrey
Carotid Arteries: Contrast-enhanced US Angiography--Preliminary Clinical Experience
Radiology, February 1, 2004; 230(2): 561 - 568.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
G. A. Whalley, G. D. Gamble, H. J. Walsh, S. P. Wright, S. Agewall, N. Sharpe, and R. N. Doughty
Effect of tissue harmonic imaging and contrast upon between observer and test-retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure
Eur J Heart Fail, January 1, 2004; 6(1): 85 - 93.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
J. A. Fox, V. Formanek, A. Friedrich, and S. K. Shernan
Intraoperative Echocardiography
Card. Surg. Adult, January 1, 2003; 2(2003): 283 - 314.
[Full Text]


Home page
J Ultrasound MedHome page
J. F. Zachary, S. A. Hartleben, L. A. Frizzell, and W. D. O'Brien Jr
Arrhythmias in Rat Hearts Exposed to Pulsed Ultrasound After Intravenous Injection of a Contrast Agent
J. Ultrasound Med., December 1, 2002; 21(12): 1347 - 1356.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
H. Becher, K. Tiemann, S. Kuntz-Hehner, H. Omran, and T. Schlosser
Diagnostic impact of contrast echocardiography for assessment of left ventricular function and myocardial perfusion in patients with coronary artery disease
Eur. Heart J. Suppl., March 1, 2002; 4(suppl_C): C12 - C21.
[Abstract] [PDF]


Home page
ChestHome page
T. T. Nguyen, M. R. Dhond, R. Sabapathy, and W. J. Bommer
Contrast Microbubbles Improve Diagnostic Yield in ICU Patients With Poor Echocardiographic Windows
Chest, October 1, 2001; 120(4): 1287 - 1292.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. L. Thomson, A.-J. Basmadjian, A. J. Rainbird, M. Razavi, J.-F. Avierinos, P. A. Pellikka, K. R. Bailey, J. F. Breen, and M. Enriquez-Sarano
Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurements: A prospective, randomly assigned, blinded study
J. Am. Coll. Cardiol., September 1, 2001; 38(3): 867 - 875.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Kuntz-Hehner, J. Goenechea, C. Pohl, T. Schlosser, C. Veltmann, C. Lentz, S. Lohmaier, A. Ehlgen, H. Omran, H. Becher, et al.
Continuous-Infusion Contrast-enhanced US: In Vitro Studies of Infusion Techniques with Different Contrast Agents
Radiology, September 1, 2001; 220(3): 647 - 654.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
V. Mor-Avi, E. G. Caiani, K. A. Collins, C. E. Korcarz, J. E. Bednarz, and R. M. Lang
Combined Assessment of Myocardial Perfusion and Regional Left Ventricular Function by Analysis of Contrast-Enhanced Power Modulation Images
Circulation, July 17, 2001; 104(3): 352 - 357.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
M. J K Blomley, J. C Cooke, E. C Unger, M. J Monaghan, and D. O Cosgrove
Science, medicine, and the future: Microbubble contrast agents: a new era in ultrasound
BMJ, May 19, 2001; 322(7296): 1222 - 1225.
[Full Text]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. Suehiro, S. Takuma, C. Cardinale, T. Hozumi, J. Shimizu, H. Yano, M. R. Di Tullio, J. Wang, C. R. Smith, D. Burkhoff, et al.
Assessment of segmental wall motion abnormalities using contrast two-dimensional echocardiography in awake mice
Am J Physiol Heart Circ Physiol, April 1, 2001; 280(4): H1729 - H1735.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. Poldermans, J. J. Bax, A. Elhendy, F. Sozzi, E. Boersma, I. R. Thomson, and L. J. Jordaens
Long-term Prognostic Value of Dobutamine Stress Echocardiography in Patients With Atrial Fibrillation
Chest, January 1, 2001; 119(1): 144 - 149.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
G. Mychaskiw II, A. E. Badr, R. Tibbs, B. R. Clower, and J. H. Zhang
Optison (FS069) Disrupts the Blood-Brain Barrier in Rats
Anesth. Analg., October 1, 2000; 91(4): 798 - 803.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. K. Heinle, J. Noblin, P. Goree-Best, A. Mello, G. Ravad, S. Mull, P. Mammen, and P. A. Grayburn
Assessment of Myocardial Perfusion by Harmonic Power Doppler Imaging at Rest and During Adenosine Stress : Comparison With 99mTc-Sestamibi SPECT Imaging
Circulation, July 4, 2000; 102(1): 55 - 60.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
S. M. Bierig, J. V. Chapman, C. Newman, and V. Zuck
Contrast Echocardiography in Clinical Practice: Integration of Contrast Echocardiography
Journal of Diagnostic Medical Sonography, May 1, 2000; 16(3): 97 - 102.
[Abstract] [PDF]


Home page
CirculationHome page
W. A. Zoghbi and E. Barasch
Dobutamine MRI: : A Serious Contender in Pharmacological Stress Imaging?
Circulation, February 16, 1999; 99(6): 730 - 732.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, J. L.
Right arrow Articles by Bruns, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, J. L.
Right arrow Articles by Bruns, D. E.

 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement