Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 2008; 52:446-449, doi:10.1016/j.jacc.2008.04.038
© 2008 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (18)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sugeng, L.
Right arrow Articles by Lang, R. M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Sugeng, L.
Right arrow Articles by Lang, R. M.

Live 3-Dimensional Transesophageal Echocardiography

Initial Experience Using the Fully-Sampled Matrix Array Probe

Lissa Sugeng, MD, MPH*,*, Stanton K. Shernan, MD{dagger}, Ivan S. Salgo, MD, MS{ddagger}, Lynn Weinert, BS*, Doug Shook, MD{dagger}, Jai Raman, MD, PhD*, Valluvan Jeevanandam, MD*, Frank DuPont, MD*, Scott Settlemier, BS{ddagger}, Bernard Savord, MS{ddagger}, John Fox, MD{dagger}, Victor Mor-Avi, PhD* and Roberto M. Lang, MD*

* Departments of Medicine (Section of Cardiology), Cardiac Surgery, and Anesthesia and Critical Care, University of Chicago, Chicago, Illinois
{dagger} Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
{ddagger} Philips Medical Systems, Andover, Massachusetts.


Figure 1
View larger version (112K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1 Volume-Rendered 3D-MTEE Views of Mitral and Aortic Valves

Example of systolic (left) and diastolic (right) still frames of 3D-MTEE real-time volume renderings of the MV from the left atrial perspective (A and B) and the aortic valves (C and D) from the ascending aorta. AV = atrioventricular valve; MV = mitral valve; 3D-MTEE = 3-dimensional matrix array transesophageal echocardiography.

 

Figure 2
View larger version (108K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2 Volume-Rendered 3D-MTEE Views of Different Cardiac Structures

Examples of the left atrial appendage (LAA) visualized en-face (A) and in the long-axis view (B) showing the ridge separating the LAA from left upper pulmonary vein (LUPV); (C) interatrial septum (IAS) from the left atrial perspective showing the foramen ovale (FO); (D) tricuspid valve displayed from the right atrial perspective showing the septal (S), anterior (A), and posterior (P) leaflets. 3D-MTEE = 3-dimensional matrix array transesophageal echocardiography.

 




 