J Am Coll Cardiol, 2003; 41:73-80
© 2003 by the American College of Cardiology Foundation
This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ellenbogen, K. A.
Right arrow Articles by Verness, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ellenbogen, K. A.
Right arrow Articles by Verness, D.

Detection and management of animplantable cardioverter defibrillator lead failure

Incidence and clinical implications

Kenneth A. Ellenbogen, MD, FACC*,*, Mark A. Wood, MD, FACC*, Richard K. Shepard, MD*, Henry F. Clemo, MD, PhD, FACC*, Tim Vaughn, BS{dagger}, Keith Holloman, BA{dagger}, Marlene Dow, RN{dagger}, Jeanne Leffler, RN*, Athula Abeyratne, PhD{dagger} and Dave Verness, BS, PE, CQE{dagger}

* Division of Cardiology, Medical College of Virginia/Virginia Commonwealth University, Richmond, Virginia, USA
{dagger} Medtronic, Inc., Minneapolis, Minnesota, USA



View larger version (61K):

[in a new window]
 
Figure 1 Schematic diagram of Medtronic 6936 coaxial tripolar implantable cardioverter defibrillator lead. HVB = high voltage distal coil; P/S = pace/sense.

 


View larger version (26K):

[in a new window]
 
Figure 2 Flow chart for all patients undergoing implantation of the Medtronic 6936 implantable cardioverter defibrillator (ICD) lead. Current clinical status for all ICD leads is summarized. DFT = defibrillation threshold; EGM = electrograms.

 


View larger version (102K):

[in a new window]
 
Figure 3 Stored intracardiac electrograms from a patient presenting with sustained monomorphic ventricular tachycardia (rate, 200 beats/min) associated with lightheadedness and dizziness. The patient received an appropriate shock for ventricular tachycardia, which terminated this arrhythmia, then received a total of five additional inappropriate shocks due to oversensing during sinus rhythm immediately after appropriate therapy was delivered.

 


View larger version (35K):

[in a new window]
 
Figure 4 Kaplan-Meier survival curve for the Medtronic 6936 implantable cardioverter defibrillator lead.

 


View larger version (43K):

[in a new window]
 
Figure 5 Two graphs demonstrating examples of patients with measurement of implantable cardioverter defibrillator (ICD) ring-to-coil impedance with translation software. (A) A drop in lead impedance (down arrow) precedes an inappropriate detection (up arrow) by a period of over 20 weeks. (B) A drop in lead impedance (down arrow) preceded ICD lead failure and need for lead extraction by almost one year. Lead extraction was performed in this patient before delivery of inappropriate shocks. Both of these patients underwent microscopic examination of the leads confirming the presence of metal ion oxidation breaching. VF = ventricular fibrillation.

 