CLINICAL RESEARCH: CONGENITAL HEART DISEASE
Interventional Atrial Septal Defect Closure Using a Totally Bioresorbable Occluder Matrix
Development and Preclinical Evaluation of the BioSTAR Device
Christian Jux, MD*,*,
Harald Bertram, MD ,
Peter Wohlsein, DVM ,
Michael Bruegmann, DVM and
Thomas Paul, MD, FACC*
* Departments of Pediatric Cardiology and Pediatric Intensive Care Medicine, Georg-August University, Goettingen, Germany
Hannover Medical School, Hannover, Germany
Institute of Pathology, School of Veterinary Medicine, Hannover, Germany
Manuscript received October 17, 2005;
revised manuscript received February 9, 2006,
accepted February 14, 2006.
* Reprint requests and correspondence: Dr. Christian Jux, Department of Pediatric Cardiology and Pediatric Intensive Care Medicine, Georg-August University, Robert Koch Strasse 40, D-37099 Goettingen, Germany
(Email: Dr.C.Jux{at}medizin.uni-goettingen.de).
OBJECTIVES: We sought to test the hypothesis that interventional atrial septal defect (ASD) closure can be performed safely and effectively using a bioresorbable occluder matrix.
BACKGROUND: The ideal septal occluder scaffold should promote the healthiest and most complete healing response while eventually facilitating the full resorption of the material and leaving "native" tissue behind, thus minimizing the potential for future complications from chronic foreign body and maintaining the possibility for later unobstructed transseptal access to the left atrium.
METHODS: The STARFlex occluders (NMT Medical Inc., Boston, Massachusetts) were modified by substituting the conventional polyester fabric for a bioengineered, acellular type-I collagen matrix derived from porcine submucosa with a heparin-coated surface (BioSTAR occluder, NMT Medical Inc.). Comparative transcatheter closure of ASDs was performed in young sheep (n = 36). Gross pathology and histopathology were obtained after follow-up periods ranging from 7 days to 2 years.
RESULTS: The STARFlex (control) devices were encapsulated time-dependently by ingrown fibrous tissue. Histology showed a mild but chronically persisting foreign body reaction. By contrast, BioSTAR devices exhibited a mild-to-moderate transient cellular immune response. Heparin coating of the BioSTAR surface improved the biocompatibility of the device by reducing surface thrombogencity. A remodeling process of the collagen scaffold, starting after 30 days in vivo, resulted in the full replacement of the matrix by host tissue after 2 years of follow-up.
CONCLUSIONS: The BioSTAR device is the first septal occluder with a totally bioresorbable matrix that is fully replaced by host tissue during the healing process. The promising results of this study support testing of the BioSTAR device in clinical trials.
|
Abbreviations and Acronyms
| | ASD = atrial septal defect | | ICE = intracardiac echocardiography | | ICL = intestinal collagen layer |
|
This article has been cited by other articles:

|
 |

|
 |
 
M. Cikirikcioglu, S. Cherian, R. Lerch, M.-J. Licker, M. Roffi, R. F. Bonvini, and A. Kalangos
Late Tamponade Secondary to Aortic Root Perforation by BioSTAR Septal Closure Device
Ann. Thorac. Surg.,
February 1, 2011;
91(2):
604 - 606.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. J. Van den Branden, M. C. Post, H. W. Plokker, J. M. ten Berg, and M. J. Suttorp
Patent Foramen Ovale Closure Using a Bioabsorbable Closure Device: Safety and Efficacy at 6-Month Follow-Up
J. Am. Coll. Cardiol. Intv.,
September 1, 2010;
3(9):
968 - 973.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. S. Schwartz, D. R. Holmes, R. A. Van Tassel, R. Hauser, T. D. Henry, M. Mooney, R. Matthews, S. Doshi, R. M. Jones, and R. Virmani
Left Atrial Appendage Obliteration: Mechanisms of Healing and Intracardiac Integration
J. Am. Coll. Cardiol. Intv.,
August 1, 2010;
3(8):
870 - 877.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Hara, T. K. Jones, E. R. Ladich, R. Virmani, D. C. Auth, J. E. Eichinger, R. J. Sommer, R. A. Van Tassel, and R. S. Schwartz
Patent Foramen Ovale Closure by Radiofrequency Thermal Coaptation: First Experience in the Porcine Model and Healing Mechanisms Over Time
Circulation,
August 7, 2007;
116(6):
648 - 653.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. N. DeMaria, O. Ben-Yehuda, G. K. Feld, G. S. Ginsburg, B. H. Greenberg, W. Y.W. Lew, J. A.C. Lima, A. S. Maisel, J. Narula, D. J. Sahn, et al.
Highlights of the Year in JACC 2006
J. Am. Coll. Cardiol.,
January 30, 2007;
49(4):
509 - 527.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. J. Mullen, D. Hildick-Smith, J. V. De Giovanni, C. Duke, W. S. Hillis, W. L. Morrison, and C. Jux
BioSTAR Evaluation STudy (BEST): A Prospective, Multicenter, Phase I Clinical Trial to Evaluate the Feasibility, Efficacy, and Safety of the BioSTAR Bioabsorbable Septal Repair Implant for the Closure of Atrial-Level Shunts
Circulation,
October 31, 2006;
114(18):
1962 - 1967.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|