Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1987; 9:1349-1356
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gabry, M.
Right arrow Articles by Furman, S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gabry, M.
Right arrow Articles by Furman, S

Automatic implantable cardioverter-defibrillator: patient survival, battery longevity and shock delivery analysis

MD Gabry, R Brodman, D Johnston, R Frame, SG Kim, LE Waspe, JD Fisher, and S Furman

The automatic implantable cardioverter-defibrillator (AICD) has been shown to reduce the mortality rate of patients with malignant ventricular tachyarrhythmias. This report describes experience with implantation of 36 automatic implantable cardioverter-defibrillators (AID-B and AID-BR models) in 22 persons over a 44 month patient follow-up period (mean 19.6 months). There were five deaths: two patients died suddenly 22 and 29 months, respectively, after their second implant, one died of congestive heart failure, one died of respiratory failure and one died of catheter sepsis. Although 11 (50%) of the 22 patients never received a countershock for a ventricular tachyarrhythmia and are still alive, the other 11 received one or more spontaneous countershocks. Nine patients (41%) experienced spurious shocks during the follow-up period. Assuming that the first shock for presumed ventricular tachyarrhythmia prevented death, the hypothetical cumulative survival of patients at 42 months would have been 34 +/- 14.1% in the absence of an automatic implantable cardioverter defibrillator rather than the actual survival rate of 59 +/- 16.8%. The cumulative device survival of the 36 AID-B units was 92 +/- 5.62% at 15 months but diminished to 37 +/- 14.4% by 20 months. No unit lasted longer than 22 months. There were 12 battery depletions. The number of shocks emitted did not influence unit longevity. The manufacturer's elective replacement indicator is of uncertain validity. Six units remained active 7 to 17 months after surpassing their replacement indicator. The automatic implantable cardioverter-defibrillator prolongs the life of many patients with otherwise intractable arrhythmias.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
EuropaceHome page
S.-C. Seow, C. S. Tolentino, J. Zhao, and T.-W. Lim
Azygous vein coil lowers defibrillation threshold in patients with high defibrillation threshold
Europace, June 1, 2011; 13(6): 825 - 828.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. M. McCarthy
Ventricular aneurysms, shock, and late follow-up in patients with heart failure
J. Thorac. Cardiovasc. Surg., August 1, 2003; 126(2): 323 - 325.
[Full Text] [PDF]


Home page
ANN INTERN MEDHome page
G. D. Sanders, M. A. Hlatky, N. R. Every, K. M. McDonald, P. A. Heidenreich, L. S. Parsons, and D. K. Owens
Potential Cost-Effectiveness of Prophylactic Use of the Implantable Cardioverter Defibrillator or Amiodarone after Myocardial Infarction
Ann Intern Med, November 20, 2001; 135(10): 870 - 883.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J P Bourke, A Loaiza, G Parry, C Hilton, S Furniss, J Dark, and J Forty
Role of orthotopic heart transplantation in the management of patients with recurrent ventricular tachyarrhythmias following myocardial infarction
Heart, November 1, 1998; 80(5): 473 - 478.
[Abstract] [Full Text]


Home page
CirculationHome page
Y. Yamanouchi, K. A. Mowrey, M. J. Niebauer, P. J. Tchou, and B. L. Wilkoff
Additional Lead Improves Defibrillation Efficacy With an Abdominal `Hot Can' Electrode System
Circulation, December 16, 1997; 96(12): 4400 - 4407.
[Abstract] [Full Text]


Home page
CirculationHome page
G. Gioia, B. Bagheri, C. D. Gottlieb, D. S. Schwartzman, D. J. Callans, F. E. Marchlinski, J. Heo, and A. E. Iskandrian
Prediction of Outcome of Patients With Life-Threatening Ventricular Arrhythmias Treated With Automatic Implantable Cardioverter-Defibrillators Using SPECT Perfusion Imaging
Circulation, January 21, 1997; 95(2): 390 - 394.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
L. A. Robinson, J. R. Windle, and A. R. Easley
Options in managing the patient with high defibrillation thresholds
Ann. Thorac. Surg., May 1, 1994; 57(5): 1184 - 1192.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
T. J. Cohen, P. R. Reid, M. M. Mower, M. Mirowski, D. Aarons, J. Juanteguy, and E. P. Veltri
The Automatic Implantable Cardioverter-Defibrillator: Long-term Clinical Experience and Outcome at a Hospital Without an Open-Heart Surgery Program
Arch Intern Med, January 1, 1992; 152(1): 65 - 69.
[Abstract] [PDF]


Home page
ANN INTERN MEDHome page
M. Akhtar, H. Garan, M. H. Lehmann, and P. J. Troup
Sudden Cardiac Death: Management of High-Risk Patients
Ann Intern Med, March 15, 1991; 114(6): 499 - 512.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
E. S. Yee
Automatic Implantable Cardioverter Defibrillators: Surgical Approaches for Optimal Function
Vascular and Endovascular Surgery, November 1, 1989; 23(6): 458 - 463.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
S. Saksena, N. G. Tullo, R. B. Krol, and A. M. Mauro
Initial Clinical Experience With Endocardial Defibrillation Using an Implantable Cardioverter/Defibrillator With a Triple-Electrode System
Arch Intern Med, October 1, 1989; 149(10): 2333 - 2339.
[Abstract] [PDF]


Home page
JAMAHome page
A. S. Manolis, H. Rastegar, and N. A. M. Estes III
Automatic Implantable Cardioverter Defibrillator: Current Status
JAMA, September 8, 1989; 262(10): 1362 - 1368.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. F. O. Tyers
Reply
Ann. Thorac. Surg., March 1, 1989; 47(3): 485 - 485.
[PDF]


Home page
ANN INTERN MEDHome page
P. J. Tchou, N. Kadri, J. Anderson, J. A. Caceres, M. Jazayeri, and M. Akhtar
Automatic Implantable Cardioverter Defibrillators and Survival of Patients with Left Ventricular Dysfunction and Malignant Ventricular Arrhythmias
Ann Intern Med, October 1, 1988; 109(7): 529 - 534.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement