JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1987; 9:1306-1310
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sprecher, D.
Right arrow Articles by Kisslo, J
Right arrow Search for Related Content
PubMed
Right arrow Articles by Sprecher, D.
Right arrow Articles by Kisslo, J

In vitro color flow, pulsed and continuous wave Doppler ultrasound masking of flow by prosthetic valves

DL Sprecher, R Adamick, D Adams, and J Kisslo

On the hypothesis that Doppler ultrasound fails to penetrate prosthetic valves, an in vitro flow simulation system was constructed in a large water tank. Conventional pulsed, continuous wave and Doppler color flow systems were used to detect flow in tubing placed diagonally within the water and maintained by a continuous pump. After control periods of flow detection within the tubing, six different prosthetic valves were interposed on a stage between the transducer and the tubing. In comparison with control measurements, detection of flow within the tubing was impossible when the Doppler beam traversed the central occluding ball of the Starr-Edwards Silastic prosthesis by any modality. Marked reduction in the detection of the Doppler signal was noted for the Starr-Edwards stellite prosthesis with only slight improvement in the ability to detect the flow signals through the central occluding discs of the Bjork-Shiley, Hall-Kastor and St. Jude valves. In distinction to the other valves, the ability of Doppler ultrasound to detect flow behind the cusps of the Carpentier-Edwards heterograft was similar to that during the control period. An understanding of flow masking should improve the clinical utility of Doppler methods for investigating prosthetic valve dysfunction.


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
E.G. Cape, W. Jaarsma, and A.P. Yoganathan
Echo Doppler principles, techniques and applications for the cardiac surgeon
Eur. J. Cardiothorac. Surg., January 1, 1992; 6(suppl_1): S2 - S12.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1987 by the American College of Cardiology Foundation.