|
|
||||||||||
|
J Am Coll Cardiol, 1987; 9:655-660 © 1987 by the American College of Cardiology Foundation |
Percutaneous balloon dilation of the aortic valve has recently been proposed as a palliative procedure for treating nonsurgical candidates with calcific aortic stenosis. To assess the safety, efficacy and mechanisms of successful balloon valvuloplasty, postmortem (n = 33) and intraoperative (n = 6) balloon aortic valvuloplasty was performed in the hearts of 39 elderly patients with calcific aortic stenosis. The cause of aortic stenosis was degenerative nodular calcification in 28 cases, calcific bicuspid aortic stenosis in 8 cases and rheumatic heart disease in 3 cases. Balloon dilation was performed with 15 to 25 mm balloons in the postmortem specimens, and with 18 to 20 mm balloons in the operating room immediately before aortic valve replacement. After balloon dilation, valve orifice dimensions and leaflet mobility increased in all patients. The mechanisms of successful dilation included fracture of calcified nodules in 16 aortic valves, separation of fused commissures in 5 valves, both in 6 valves and grossly inapparent microfractures in 12 valves. Valve leaflet avulsion occurred in one heart after inflation with a clearly oversized balloon. Liberation of calcific debris, valve ring disruption or midleaflet tears did not occur in any heart. In conclusion, there are at least three mechanisms of successful aortic valvuloplasty, depending on the origin of valvular stenosis. Embolic phenomena and acute valvular regurgitation do not appear to be likely events associated with this procedure.
This article has been cited by other articles:
![]() |
N. D. Desai and G. T. Christakis Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894. [Full Text] |
||||
![]() |
R. O. Bonow, B. A. Carabello, K. Chatterjee, A. C. de Leon Jr, D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, et al. ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Developed in Collaboration With the Society of Cardiovascular Anesthesiologists Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons J. Am. Coll. Cardiol., August 1, 2006; 48(3): e1 - e148. [Full Text] [PDF] |
||||
![]() |
N. D. Desai and G. T. Christakis Stented Mechanical/Bioprosthetic Aortic Valve Replacement Card. Surg. Adult, January 1, 2003; 2(2003): 825 - 856. [Full Text] |
||||
![]() |
R. H. Plack, G. M. Hutchins, and J. A. Brinker Conduction System Injury After Aortic Valve Dilation in the Dog Single- Versus Double-Balloon Catheters Angiology, November 1, 1990; 41(11): 929 - 935. [Abstract] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |