JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1987; 9:647-654
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miura, T
Right arrow Articles by Downey, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miura, T
Right arrow Articles by Downey, J.

Determinants of infarct size during permanent occlusion of a coronary artery in the closed chest dog

T Miura, DM Yellon, DJ Hearse, and JM Downey

One hundred nine dogs subjected to experienced experimental coronary occlusion were retrospectively examined in an attempt to identify factors influencing infarct size. A coronary artery was occluded by an embolus. The field of the occluded artery (zone at risk) was determined by subsequent autoradiography of 141-cerium-labeled microspheres that were injected into the left ventricle 2 minutes after embolization. Fifty-eight dogs were analyzed after 24 hours of embolization and 51 after 48 hours. Infarct size (assessed by tetrazolium staining) was directly proportional to the size of the zone at risk in both groups. The percent of the risk zone that developed infarction was independent of risk zone size in both the 24 and 48 hour groups. No differences were seen between male and female animals or between the dogs with left circumflex or left anterior descending artery occlusion. Infarct size was also independent of the heart rate-systolic pressure product at the time of coronary occlusion, and of the time of year. Eighty percent of the variability in the portion of the risk zone that infarcted in this population could be explained by the level of collateral flow in the risk zone 2 minutes after embolization. The linear regression between the percent of the risk zone that developed infarction and collateral flow was the same in slope and intercept between the 24 and 48 hour groups. The correlation between infarct size and collateral flow was slightly better when collateral flow was expressed as a percent of flow in the nonischemic zone than when it was expressed in absolute terms.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Sharony, E. Porat, Y. Nishimura, B. Meyns, S. Ozaki, R. Racz, W. Flameng, and G. Uretzky
THE INTRA-AORTIC CANNULA PUMP: A NOVEL ASSIST DEVICE FOR THE ACUTELY FAILING HEART
J. Thorac. Cardiovasc. Surg., November 1, 1999; 118(5): 924 - 929.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1987 by the American College of Cardiology Foundation.