cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1987; 9:599-607
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Garabedian, H.
Right arrow Articles by Collen, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Garabedian, H.
Right arrow Articles by Collen, D

Comparative properties of two clinical preparations of recombinant human tissue-type plasminogen activator in patients with acute myocardial infarction

HD Garabedian, HK Gold, RC Leinbach, JA Johns, T Yasuda, M Kanke, and D Collen

The biologic properties of two clinical preparations of recombinant human tissue-type plasminogen activator were studied in 52 patients with acute myocardial infarction. The first preparation (G11021) has been used in all clinical trials reported to date, whereas the second preparation (G11035) is now produced for future clinical use. When both preparations were infused intravenously for 90 minutes at rates of 4 to 11 micrograms/kg per min, plateau levels of the drug in plasma ranged from 0.52 +/- 0.15 to 1.8 +/- 0.4 micrograms/ml and were linearly correlated with the infusion rate. However, G11035 yielded plasma levels that were approximately 35% lower than those obtained with G11021 (p less than 0.025). The postinfusion disappearance rate of the drug from plasma could be described by a two compartment disposition model with the following pharmacokinetic variables. For G11021, an alpha half-life of 4.1 to 6.3 minutes, a beta half-life of 41 to 50 minutes, a central compartment volume of 3.5 to 5.4 liters, a total distribution volume of 28 to 44 liters and a plasma clearance of 450 to 640 ml/min. For G11035 these variables were 3.6 to 4.6 minutes, 39 to 53 minutes, 3.8 to 6.6 liters, 27 to 40 liters and 520 to 1,000 ml/min, respectively, indicating that G11035 is cleared more rapidly from the circulation. G11021 at 4 micrograms/kg per min and G11035 at 7 micrograms/kg per min did not effectively produce thrombolysis. A coronary reperfusion rate of 81% (13 of 16 patients) was obtained with 5.3 micrograms/kg per min of G11021 and a rate of 86% (6 of 7 patients) was obtained with 9.4 micrograms/kg per min of G11035.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
D. E. Vaughan, J.-L. Rouleau, P. M. Ridker, J. M. O. Arnold, F. J. Menapace, and M. A. Pfeffer
Effects of Ramipril on Plasma Fibrinolytic Balance in Patients With Acute Anterior Myocardial Infarction
Circulation, July 15, 1997; 96(2): 442 - 447.
[Abstract] [Full Text]


Home page
Journal of Pharmacy PracticeHome page
J. Buchanan, H. B. Lee, and R. D. Lauper
Recombinant DNA Technology
Journal of Pharmacy Practice, January 1, 1991; 4(2): 87 - 93.
[PDF]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
E. J. Harris JR and J. M. Porter
Thrombolytic Therapy and Modern Vascular Surgery: An Overview
Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1989; 2(2): 40 - 63.
[PDF]


Home page
Arch NeurolHome page
S. E. Carlson, M. S. Aldrich, H. S. Greenberg, and E. J. Topol
Intracerebral Hemorrhage Complicating Intravenous Tissue Plasminogen Activator Treatment
Arch Neurol, October 1, 1988; 45(10): 1070 - 1073.
[Abstract] [PDF]



 
  cardiology careers collections past issues search home