JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1987; 9:127-135
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnston, D.
Right arrow Articles by Okada, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnston, D.
Right arrow Articles by Okada, R.

In vivo detection of reperfused myocardium by nuclear magnetic resonance imaging

DL Johnston, P Liu, BR Rosen, RA Levine, PA Beaulieu, TJ Brady, and RD Okada

To assess the potential of in vivo nuclear magnetic resonance imaging for the detection of reperfused myocardium, in vivo T2-weighted spin echo images were obtained of dogs at 0.15 tesla. Imaging was done during 3 hours of coronary occlusion (group I), and during 3 hours of coronary occlusion followed by 1 hour of reperfusion (group II). On sacrifice, the hearts were drained of blood and imaged in situ to determine the effect of in vivo imaging on myocardial signal intensity. The hearts were then excised and imaged at 1.4 tesla to compare the effect of high resolution imaging on image quality. Of the six hearts in group I and the eight hearts in group II with a myocardial infarction and suitable image quality, four of the former hearts and six of the latter demonstrated a small but visible increase in infarct signal intensity at 3 hours of occlusion on the time to echo [TE] = 60 ms, single echo images. The T2 (transverse) relaxation time of the infarct (measured in vitro by spectrometer) increased by 13% when compared with normal tissue. In contrast, the reperfused infarct was more easily visualized, with signal intensity increasing by 31 +/- 17% and infarct T2 increasing by 20%. Imaged at 1.4 tesla, the excised hearts showed the infarct to be subendocardial during occlusion and extending transmurally with reperfusion. It is concluded that, although visualized, the increase in infarct signal intensity at 3 hours of coronary occlusion is small and this is consistent with the small increase in infarct signal intensity and T2 relaxation.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
E. E. van der Wall, H. W. Vliegen, A. de Roos, and A. V.G. Bruschke
Magnetic Resonance Imaging in Coronary Artery Disease
Circulation, November 1, 1995; 92(9): 2723 - 2739.
[Abstract] [Full Text]


Home page
J Intensive Care MedHome page
R. C. Becker
Reperfusion of Nonviable Myocardium: Lessons from Thrombolytic Therapy
J Intensive Care Med, January 1, 1990; 5(1): 1 - 2.
[PDF]


Home page
J Intensive Care MedHome page
D. D. Miller
Analytic Reviews : Detection of Viable Myocardium after Myocardial Infarction
J Intensive Care Med, January 1, 1990; 5(1): 7 - 22.
[PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1987 by the American College of Cardiology Foundation.