JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1987; 9:101-107
© 1987 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Geschwind, H.
Right arrow Articles by Kennedy, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Geschwind, H.
Right arrow Articles by Kennedy, H.

Development and experimental application of contact probe catheter for laser angioplasty

HJ Geschwind, JD Blair, D Mongkolsmai, MJ Kern, J Stern, U Deligonul, and HL Kennedy

A sapphire contact probe laser catheter was developed to increase the dimensions of tunnels created by laser angioplasty. The device consisted of a round sapphire probe (2.2 mm diameter) attached to an 8F catheter into which a 0.2 mm optical fiber was inserted with a tip maintained at 3 mm from the sapphire. The fiber was connected to a continuous wave neodymium yttrium aluminum garnet (Nd-YAG) laser. A saline perfusate was circulated through the catheter during laser emissions to prevent excessive heating of the fiber tip. The system was used in vitro on 16 sections of atherosclerotic calcified human cadaver aortic walls, using diluted blood as a medium, at powers ranging from 10 to 40 W and exposure times from 1 to 4 seconds. Six craters were created at each energy level. The system was also used on six human cadaver, agar-embedded, obstructed iliac and femoral arteries, using 40 W and 2 second laser emissions. Dimensions of probe-created craters were compared with those obtained using bare fibers. The shape of the probe craters was that of a truncated cone with the entry hole wider than the exit, as opposed to the cylindrical shape created with unmodified bare fibers. At 120 J (seconds X watts), areas of entry and exit probe-formed holes were greater than those created with the bare fibers (6.7 +/- 0.5 and 3.4 +/- 0.6 versus 0.2 +/- 0.01 mm2, respectively, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
ANGIOLOGYHome page
S. Ashley, S. G. Brooks, A. A. Gehani, R. C. Kester, and M. R. Rees
Experimental Analysis of Sapphire Contact Probes for ND-YAG Laser Angioplasty
Angiology, June 1, 1990; 41(6): 453 - 462.
[Abstract] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
E. B. Diethrich, E. Timbadia, I. Bahadir, S. Carroll, S. Zenzen, and K. Coburn
Intraoperative Coronary Laser Recanalization: Evaluation of Safety in Ten Patients
Vascular and Endovascular Surgery, September 1, 1988; 22(5): 335 - 343.
[Abstract] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1987 by the American College of Cardiology Foundation.