JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 8:1455-1460
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jang, I.
Right arrow Articles by Van de Werf, F
Right arrow Search for Related Content
PubMed
Right arrow Articles by Jang, I.
Right arrow Articles by Van de Werf, F

Coronary thrombolysis with recombinant tissue-type plasminogen activator: patency rate and regional wall motion after 3 months

IK Jang, J Vanhaecke, H De Geest, M Verstraete, D Collen, and F Van de Werf

In a double-blind, placebo-controlled, randomized trial the long-term (+/- 3 months) effects of intravenous administration of recombinant tissue-type plasminogen activator (rt-PA) versus placebo were compared in relation to left ventricular function, coronary patency rate and antigenicity in 28 patients with a first myocardial infarction. Patency rate of the infarct-related coronary artery at the end of the rt-PA/placebo infusion and after 3 months of medical treatment (including oral anticoagulant agents) was 86 and 71%, respectively, in the rt-PA group, and 21 and 58%, respectively, in the placebo group. Regional wall motion of the infarct-related area was quantitated with digital subtraction angiography. Intrapatient comparisons revealed significant improvement in regional wall motion after 3 months in both the rt-PA and placebo groups. The improvement in the rt-PA group was not significantly greater than that in the placebo group. Thirteen patients (10 with rt-PA and 3 with placebo) with persistent patency (both early and late) of the infarct-related coronary artery showed a significant improvement of both global and regional left ventricular function, while 8 patients (2 with rt-PA and 6 with placebo) with persistent occlusion showed no changes. Antibodies against rt-PA were not detected in serum 2 weeks after the infusion, which is indicative of the lack of antigenicity of rt-PA and allows for its repeated administration.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.