cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1986; 8:791-799
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chou, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chou, T.

When is the vectorcardiogram superior to the scalar electrocardiogram?

TC Chou

The clinical usefulness of the vectorcardiogram is well documented by the numerous reports published in the last 3 decades. It has been found more reliable than the electrocardiogram for the diagnosis of atrial enlargement and right ventricular hypertrophy. It is more sensitive than the electrocardiogram in the recognition of myocardial infarction, especially if the infarction is inferior or if it occurs in the presence of left bundle branch block or left anterior hemiblock. It is helpful in the diagnosis of ventricular pre-excitation and in the localization of the bypass tract. Some repolarization abnormalities are more clearly demonstrated by the vector display. However, some information, such as that on cardiac chamber size and myocardial damage, can also be obtained by other noninvasive tests that are often performed on the same patients. With the increasing awareness of cost-effectiveness of various laboratory procedures in medicine, the vectorcardiogram should no longer be considered a routine cardiac test and should be requested only for a specific clinical purpose. When properly utilized, vectorcardiography should remain a valuable diagnostic as well as teaching tool.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
I. R. Henkens, K. T. B. Mouchaers, H. W. Vliegen, W. J. van der Laarse, C. A. Swenne, A. C. Maan, H. H. M. Draisma, I. Schalij, E. E. van der Wall, M. J. Schalij, et al.
Early changes in rat hearts with developing pulmonary arterial hypertension can be detected with three-dimensional electrocardiography
Am J Physiol Heart Circ Physiol, August 1, 2007; 293(2): H1300 - H1307.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
S. Kawahito, H. Kitahata, K. Tanaka, J. Nozaki, and S. Oshita
Dynamic QRS-complex and ST-segment monitoring by continuous vectorcardiography during carotid endarterectomy
Br. J. Anaesth., February 1, 2003; 90(2): 142 - 147.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
J. Morikawa, Y. Habuchi, M. Nishio, T. Yamamoto, H. Tanaka, and K. Kashima
Delineation of Premature P Waves on Four-Dimensional Electrocardiography, a New Display of Electrical Forces by Computer Techniques
Angiology, November 1, 1996; 47(11): 1101 - 1106.
[Abstract] [PDF]



 
  cardiology careers collections past issues search home