JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 8:221-224
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, P.
Right arrow Articles by Chan, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, P.
Right arrow Articles by Chan, T.

Combined use of warfarin and adjusted subcutaneous heparin during pregnancy in patients with an artificial heart valve

PK Lee, RY Wang, JS Chow, KL Cheung, VC Wong, and TK Chan

Adjusted subcutaneous heparin was used for thromboembolism prophylaxis during 18 pregnancies in 16 women with an artificial heart valve. Oral warfarin was replaced by subcutaneous heparin as soon as pregnancy was confirmed. The dosage of heparin was adjusted to maintain a partial thromboplastin time at 1.5 times the control value and treatment was administered during the first trimester and the last 3 weeks of gestation. Warfarin was used between the 13th and 37th week. There were no maternal thromboembolic complications and none of the live-born infants showed congenital malformations, indicating that this regimen is effective. However, there were nine spontaneous abortions, including five that occurred in the first 12 weeks. The early abortions were probably related to warfarin exposure at the beginning of pregnancy. The preconception replacement of warfarin by heparin in these patients may be indicated.


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
A. J Khamooshi, F. Kashfi, S. Hoseini, M. B Tabatabaei, H. Javadpour, and F. Noohi
Anticoagulation for Prosthetic Heart Valves in Pregnancy. Is There an Answer?
Asian Cardiovasc Thorac Ann, December 1, 2007; 15(6): 493 - 496.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
A. N. Inyang, M. Jackson, A. Kumar, A. Nychka, G. Leyvi, I. Zhuravlev, K. Plestis, and J. Wasnick
A Report of a Case: Anesthetic Management of a Parturient with Severe Thrombotic Stenosis of a Mechanical Aortic Valve--An Exercise in Coordination of Subspecialties
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2005; 9(3): 261 - 263.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. A.M. Al-Lawati, M. Venkitraman, T. Al-Delaime, and J. Valliathu
Pregnancy and mechanical heart valves replacement; dilemma of anticoagulation
Eur. J. Cardiothorac. Surg., August 1, 2002; 22(2): 223 - 227.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
W. S. Chan, S. Anand, and J. S. Ginsberg
Anticoagulation of Pregnant Women With Mechanical Heart Valves: A Systematic Review of the Literature
Arch Intern Med, January 24, 2000; 160(2): 191 - 196.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S S Meschengieser, C G Fondevila, M T Santarelli, and M A Lazzari
Anticoagulation in pregnant women with mechanical heart valve prostheses
Heart, July 1, 1999; 82(1): 23 - 26.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.