JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 7:1286-1294
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Windle,
Right arrow Articles by Prystowsky, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Windle, , JR
Right arrow Articles by Prystowsky, E.

Determination of the earliest site of ventricular activation in Wolff-Parkinson-White syndrome: application of digital continuous loop two-dimensional echocardiography

Windle JR, WF Armstrong, H Feigenbaum, WM Miles, and EN Prystowsky

Surgical and transcatheter ablation of accessory atrioventricular (AV) connections (Wolff-Parkinson-White syndrome) requires accurate localization of the accessory pathway. In a canine model of endocardial pacing, a continuous loop two-dimensional echocardiographic technique was developed for determining the earliest site of ventricular activation. This technique was then used to localize accessory AV connections in patients. Echocardiographic images were acquired on videotape and converted to a digital continuous loop format, from which the earliest site of systolic motion was determined. In six dogs, using six distinct endocardial sites, two blinded observers accurately identified the earliest site of ventricular activation in 31 (86%) of 36 and 32 (89%) of 36 locations. Determination of the earliest site of ventricular activation with the continuous loop digital technique was superior to standard analog analysis in overall accuracy (p less than 0.02) and in intraobserver variability (p less than 0.004). After validation of this technique, 21 patients with 22 accessory AV connections with anterograde conduction were studied. The earliest site of mechanical activity was determined during sinus (10 patients) or atrial paced (11 patients) rhythms by two blinded observers and compared with electrophysiologic mapping and surface electrocardiograms. Digitally processed echocardiograms correctly localized the earliest site of ventricular activation in 18 of 22 connections and predicted an adjacent location in the remaining 4.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
M. D. Cheitlin, J. S. Alpert, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, T. W. Davidson, J. L. Davis, P. S. Douglas, L. D. Gillam, et al.
ACC/AHA Guidelines for the Clinical Application of Echocardiography : A Report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (Committee on Clinical Application of Echocardiography) Developed in Collaboration With the American Society of Echocardiography
Circulation, March 18, 1997; 95(6): 1686 - 1744.
[Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.