JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 7:909-915
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shelton, M.
Right arrow Articles by Friesinger, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shelton, M.
Right arrow Articles by Friesinger, G.

A new model to study quantitative effects of laser angioplasty on human atherosclerotic plaque

ME Shelton, B Hoxworth, JA Shelton, R Virmani, and GC Friesinger

A new model for analyzing the major effects of the use of any laser angioplasty system is described. Changes in any of the six major determinants of effect (energy, duration, wavelength, medium, absorption, geometry) can be evaluated. In this report a neodymium: yttrium aluminum garnet (Nd:YAG) laser was used to make 408 laser exposures in vitro on segments of human cadaveric atherosclerotic aorta. Energy, medium (air, human blood, perfluorochemical and saline), geometry and duration were varied. The depth and width of the resultant plaque craters were measured. A large amount of exposure to exposure variability was found in all groups of experiments, even when conditions were held as constant as possible in this rigidly controlled laboratory setting. This variability is attributable to differences in energy absorption by the plaque. Changes in media and fiber optic tip to plaque distance also markedly altered exposure outcome. For example, the average depth of the hole created by a 15 W, 2 second blast with the fiber tip adjacent to the plaque in blood was 1.7 +/- 0.1 mm (n = 27), but the range was between 0.5 and 2.7 mm. Under the same conditions, except with the fiber tip 1 mm away from the plaque, the average hole depth was 0.4 +/- 0.1 mm (n = 12) and the range was 0.0 to 1.7 mm. The use of this model to analyze the major determinants of lasing effects in different laser angioplasty systems should help to select the best conditions for lasing and allow assessment of the variability of outcome.


This article has been cited by other articles:


Home page
CirculationHome page
R. Mehran, G. Dangas, G. S. Mintz, R. Waksman, A. Abizaid, L. F. Satler, A. D. Pichard, K. M. Kent, A. J. Lansky, G. W. Stone, et al.
Treatment of In-Stent Restenosis With Excimer Laser Coronary Angioplasty Versus Rotational Atherectomy : Comparative Mechanisms and Results
Circulation, May 30, 2000; 101(21): 2484 - 2489.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Mehran, G. S. Mintz, L. F. Satler, A. D. Pichard, K. M. Kent, T. A. Bucher, J. J. Popma, and M. B. Leon
Treatment of In-Stent Restenosis With Excimer Laser Coronary Angioplasty : Mechanisms and Results Compared With PTCA Alone
Circulation, October 7, 1997; 96(7): 2183 - 2189.
[Abstract] [Full Text]


Home page
CirculationHome page
G. S. Mintz, J. A. Kovach, S. P. Javier, A. D. Pichard, K. M. Kent, J. J. Popma, L. F. Salter, and M. B. Leon
Mechanisms of Lumen Enlargement After Excimer Laser Coronary Angioplasty : An Intravascular Ultrasound Study
Circulation, December 15, 1995; 92(12): 3408 - 3414.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.