JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 7:843-849
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pflugfelder, P.
Right arrow Articles by Carroll, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pflugfelder, P.
Right arrow Articles by Carroll, S.

Serial imaging of canine myocardial infarction by in vivo nuclear magnetic resonance

PW Pflugfelder, G Wisenberg, FS Prato, KL Turner, and SE Carroll

Anterior infarction was produced in eight dogs to characterize serial changes in nuclear magnetic resonance signal intensity within the infarct zone. Magnetic resonance imaging was done on the day of infarction, on day 4, 5 or 6, on day 13 and day 20 using a 0.15 tesla (6.25 MHz) resistive imager. Electrocardiographically triggered spin echo (30, 45 and 60 ms echo times) and inversion recovery (400 to 500 ms inversion time) pulse sequences were employed to obtain single slice images. On day 20, the excised hearts were sectioned and examined to determine infarct location and extent. In the spin echo images, signal intensity within the ischemic zone was visibly increased in seven of the eight dogs on the day of infarction, and in all dogs by days 4 to 6. Signal intensity remained elevated in all but two dogs at day 20. With inversion recovery imaging, changes in the infarct zone were highly variable; both ill defined increases and decreases in signal intensity were noted. With a 30 ms echo time, signal intensity in the infarct zone was increased on average 29.8 +/- 24.1% above that in normal myocardium on the day of infarction. The relative signal intensity increased to 62.4 +/- 23.5% during the first 2 weeks after infarction (p less than 0.05), then decreased to 12.0 +/- 18.5% by day 20 (p less than 0.05). Similar changes were detected in the images using the 45 and 60 ms echo times. Nuclear magnetic resonance imaging therefore is able to detect regions of myocardial infarction and follow evolutionary changes in signal intensity within the infarct zone with healing.


This article has been cited by other articles:


Home page
RadiologyHome page
J. W. Goldfarb, S. Arnold, and J. Han
Recent Myocardial Infarction: Assessment with Unenhanced T1-weighted MR Imaging
Radiology, October 1, 2007; 245(1): 245 - 250.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. H. Aletras, G. S. Tilak, A. Natanzon, L.-Y. Hsu, F. M. Gonzalez, R. F. Hoyt Jr, and A. E. Arai
Retrospective Determination of the Area at Risk for Reperfused Acute Myocardial Infarction With T2-Weighted Cardiac Magnetic Resonance Imaging: Histopathological and Displacement Encoding With Stimulated Echoes (DENSE) Functional Validations
Circulation, April 18, 2006; 113(15): 1865 - 1870.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. W. Hsu, R. Xue, A. Holmes, and J. R. Forder
Delayed reduction of tissue water diffusion after myocardial ischemia
Am J Physiol Heart Circ Physiol, August 1, 1998; 275(2): H697 - H702.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. E. van der Wall, H. W. Vliegen, A. de Roos, and A. V.G. Bruschke
Magnetic Resonance Imaging in Coronary Artery Disease
Circulation, November 1, 1995; 92(9): 2723 - 2739.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.