JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1986; 7:590-594
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klementowicz, P.
Right arrow Articles by Furman, S
Right arrow Search for Related Content
PubMed
Right arrow Articles by Klementowicz, P.
Right arrow Articles by Furman, S

Selective atrial sensing in dual chamber pacemakers eliminates endless loop tachycardia

PT Klementowicz and S Furman

With the introduction of dual chamber pacemakers that have multiple atrial amplitude sensing values, selective P wave sensing is possible. Five consecutive patients were studied who had 1) retrograde atrioventricular conduction, 2) anterograde atrial signals that were at least 1.4 times larger than their corresponding retrograde atrial signals, and 3) dual chamber pulse generators that are capable of discriminating this difference in atrial amplitude. In each patient the pacemaker was programmed in the DDD mode and the postventricular atrial refractory interval was at least 100 ms shorter than the individual's minimal retrograde conduction time. Two atrial sensitivity settings were evaluated in each patient: a high setting to ensure sensing of both anterograde and retrograde P waves, and a lower setting to allow sensing of anterograde P waves only. Ambulatory electrocardiographic monitoring demonstrated that with a high sensitivity setting, each patient sustained endless loop tachycardia (mean number of episodes 41, range 6 to 143) and that a low atrial sensitivity setting eliminated the tachycardia. With the lower atrial sensitivity setting, there was only sporadic atrial undersensing (1.5 episodes for each 1,000 P waves). This study demonstrates that atrial signals having different amplitudes can be selectively sensed. Additionally, dual chamber pulse generators with multiple atrial amplitude sensitivity values can discriminate anterograde from retrograde P waves, ensure anterograde sensing, reject retrograde P waves and eliminate endless loop tachycardia.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1986 by the American College of Cardiology Foundation.