Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1986; 7:509-517
© 1986 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Otto, C.
Right arrow Articles by Huntsman, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Otto, C.
Right arrow Articles by Huntsman, L.

Determination of the stenotic aortic valve area in adults using Doppler echocardiography

CM Otto, AS Pearlman, KA Comess, RP Reamer, CL Janko, and LL Huntsman

The severity of aortic stenosis was evaluated by Doppler echocardiography in 48 adults (mean age 67 years) undergoing cardiac catheterization. Maximal Doppler systolic gradient correlated with peak to peak pressure gradient (r = 0.79, y = 0.63x + 25.2 mm Hg) and mean Doppler gradient correlated with mean pressure gradient (r = 0.77, y = 0.59x + 10.0 mm Hg) by manometry. The transvalvular pressure gradient is flow dependent, however, and associated left ventricular dysfunction was common in our patients (33%). Thus, of the 32 patients with an aortic valve area less than or equal to 1.0 cm2 at catheterization, 6 (19%) had a peak Doppler gradient less than 50 mm Hg. To take into account the influence of volume flow, aortic valve area was calculated as stroke volume, measured simultaneously by thermodilution, divided by the Doppler systolic velocity integral in the aortic jet. Aortic valve areas calculated by this method were compared with results at catheterization in the total group (r = 0.71). Significant aortic insufficiency was present in 71% of the population. In the subgroup without significant coexisting aortic insufficiency, closer agreement of valve area with catheterization was noted (n = 14, r = 0.91, y = 0.83x + 0.24 cm2). Transaortic stroke volume can be determined noninvasively by Doppler echocardiographic measures in the left ventricular outflow tract, just proximal to the stenotic valve. Aortic valve area can then be calculated as left ventricular outflow tract cross-sectional area times the systolic velocity integral of outflow tract flow, divided by the systolic velocity integral in the aortic jet.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Am Coll Cardiol ImgHome page
M.-A. Clavel, J. Rodes-Cabau, E. Dumont, R. Bagur, S. Bergeron, R. De Larochelliere, D. Doyle, E. Larose, J. G. Dumesnil, and P. Pibarot
Validation and Characterization of Transcatheter Aortic Valve Effective Orifice Area Measured by Doppler Echocardiography
J. Am. Coll. Cardiol. Img., October 1, 2011; 4(10): 1053 - 1062.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
W. J. Stewart and L. L. Rodriguez
Avoiding Patient-Prosthesis Mismatch: Is TAVI a New Solution?
J. Am. Coll. Cardiol. Img., October 1, 2011; 4(10): 1063 - 1066.
[Full Text] [PDF]


Home page
The EAE Textbook of EchocardiographyHome page
R. Rosenhek, R. Feneck, and F. Guarracino
Chapter 14a Aortic valve disease
The EAE Textbook of Echocardiography, March 1, 2011; 1(1): med-9780199599639-chapter - med-9780199599639-chapter.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
M. A. Sherif, M. Abdel-Wahab, B. Stocker, V. Geist, D. Richardt, R. Tolg, and G. Richardt
Anatomic and Procedural Predictors of Paravalvular Aortic Regurgitation After Implantation of the Medtronic CoreValve Bioprosthesis
J. Am. Coll. Cardiol., November 9, 2010; 56(20): 1623 - 1629.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Rosenhek, R. Zilberszac, M. Schemper, M. Czerny, G. Mundigler, S. Graf, J. Bergler-Klein, M. Grimm, H. Gabriel, and G. Maurer
Natural History of Very Severe Aortic Stenosis
Circulation, January 5, 2010; 121(1): 151 - 156.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
P. Cattaneo, M. Baravelli, A. Rossi, G. Mariscalco, M. Romano, D. Imperiale, A. Bregasi, and C. Anza
Ejection Fraction/Velocity Ratio Identifies Prosthesis-Patient Mismatches in Patients With Aortic Bioprosthetic Valves and Left Ventricular Dysfunction
J. Ultrasound Med., September 1, 2009; 28(9): 1167 - 1174.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. J. Halpern, R. Mallya, M. Sewell, M. Shulman, and D. R. Zwas
Differences in Aortic Valve Area Measured with CT Planimetry and Echocardiography (Continuity Equation) Are Related to Divergent Estimates of Left Ventricular Outflow Tract Area
Am. J. Roentgenol., June 1, 2009; 192(6): 1668 - 1673.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
S. M. Stevens, R. Farzaneh-Far, B. Na, M. A. Whooley, and N. B. Schiller
Development of an echocardiographic risk-stratification index to predict heart failure in patients with stable coronary artery disease: the Heart and Soul study.
J. Am. Coll. Cardiol. Img., January 1, 2009; 2(1): 11 - 20.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
D. Oxorn
The Intraoperative Quantification of Aortic Stenosis
Anesth. Analg., January 1, 2009; 108(1): 10 - 12.
[Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
H. Baumgartner, J. Hung, J. Bermejo, J. B. Chambers, A. Evangelista, B. P. Griffin, B. Iung, C. M. Otto, P. A. Pellikka, and M. Quinones
Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice
Eur Heart J Cardiovasc Imaging, January 1, 2009; 10(1): 1 - 25.
[Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
G. Leurent, E. Donal, C. de Place, C. Chabanne, R. Gervais, C. Fougerou, A. le Helloco, J.-C. Daubert, P. Mabo, and M. Laurent
Argument for a Doppler echocardiography during exercise in assessing asymptomatic patients with severe aortic stenosis
Eur Heart J Cardiovasc Imaging, January 1, 2009; 10(1): 69 - 73.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
K. K. Poh, R. A. Levine, J. Solis, L. Shen, M. Flaherty, Y.-J. Kang, J. L. Guerrero, and J. Hung
Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography
Eur. Heart J., October 2, 2008; 29(20): 2526 - 2535.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
A. Evangelista, F. Flachskampf, P. Lancellotti, L. Badano, R. Aguilar, M. Monaghan, J. Zamorano, P. Nihoyannopoulos, and on behalf of the European Association of Echocardi
European Association of Echocardiography recommendations for standardization of performance, digital storage and reporting of echocardiographic studies
Eur Heart J Cardiovasc Imaging, July 1, 2008; 9(4): 438 - 448.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
J.-P. Verhoye, I. Abouliatim, B. Lelong, A. Ingels, X. Roques, J. Pierre Villemot, T. Langanay, and A. Leguerrier
Edwards Mira bileaflet prosthesis in aortic position: midterm results of a prospective multi-centre study
Interact CardioVasc Thorac Surg, August 1, 2007; 6(4): 458 - 461.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. H Little, K.-L. Chan, and I. G Burwash
Impact of blood pressure on the Doppler echocardiographic assessment of severity of aortic stenosis
Heart, July 1, 2007; 93(7): 848 - 855.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
K. K. Stout and C. M. Otto
Indications for Aortic Valve Replacement in Aortic Stenosis
J Intensive Care Med, January 1, 2007; 22(1): 14 - 25.
[Abstract] [PDF]


Home page
HeartHome page
E Rydberg, P Gudmundsson, L Kennedy, L Erhardt, and R Willenheimer
Left atrioventricular plane displacement but not left ventricular ejection fraction is influenced by the degree of aortic stenosis
Heart, October 1, 2004; 90(10): 1151 - 1155.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. E. Richards, D. Deserranno, E. Donal, N. L. Greenberg, J. D. Thomas, and M. J. Garcia
Influence of structural geometry on the severity of bicuspid aortic stenosis
Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H1410 - H1416.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J Cardiovasc ImagingHome page
R. Moreno, J. Zamorano, C. Almeria, J. A. Perez-Gonzalez, L. Mataix, J. L. Rodrigo, D. Herrera, A. Aubele, L. Perez de Isla, E. De Marco, et al.
Isovolumic Contraction Time by Pulsed-Wave Doppler Tissue Imaging in Aortic Stenosis
Eur Heart J Cardiovasc Imaging, December 1, 2003; 4(4): 279 - 285.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. D. Caruthers, S. J. Lin, P. Brown, M. P. Watkins, T. A. Williams, K. A. Lehr, and S. A. Wickline
Practical Value of Cardiac Magnetic Resonance Imaging for Clinical Quantification of Aortic Valve Stenosis: Comparison With Echocardiography
Circulation, November 4, 2003; 108(18): 2236 - 2243.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. L. Gerber, R. A.H. Stewart, M. E. Legget, T. M. West, R. L. French, T. M. Sutton, T. G. Yandle, J. K. French, A. M. Richards, and H. D. White
Increased Plasma Natriuretic Peptide Levels Reflect Symptom Onset in Aortic Stenosis
Circulation, April 15, 2003; 107(14): 1884 - 1890.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. Garcia, J. G. Dumesnil, L.-G. Durand, L. Kadem, and P. Pibarot
Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon: practical implications with regard to quantification of aortic stenosis severity
J. Am. Coll. Cardiol., February 5, 2003; 41(3): 435 - 442.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. A. Levine and E. Schwammenthal
Stenosis is in the eye of the observer: impact of pressure recovery on assessing aortic valve area
J. Am. Coll. Cardiol., February 5, 2003; 41(3): 443 - 445.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Gelsomino, R. Frassani, P. Da Col, G. Morocutti, G. Masullo, L. Spedicato, and U. Livi
A long-term experience with the cabrol root replacement technique for the management of ascending aortic aneurysms and dissections
Ann. Thorac. Surg., January 1, 2003; 75(1): 126 - 131.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Gelsomino, G. Morocutti, R. Frassani, P. Da Col, R. Carella, and U. Livi
Usefulness of the cryolife o'brien stentless suprannular aortic valve to prevent prosthesis-patient mismatch in the small aortic root
J. Am. Coll. Cardiol., June 5, 2002; 39(11): 1845 - 1851.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Gelsomino, G. Morocutti, P. Da Col, R. Frassani, R. Carella, G. Minen, and U. Livi
Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results
Ann. Thorac. Surg., June 1, 2002; 73(6): 1830 - 1836.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J.-L. Monin, M. Monchi, V. Gest, A.-M. Duval-Moulin, J.-L. Dubois-Rande, and P. Gueret
Aortic stenosis with severe left ventricular dysfunction and low transvalvular pressure gradients: Risk stratification by low-dose dobutamine echocardiography
J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2101 - 2107.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
D. E. Powell, P. A. Tunick, B. P. Rosenzweig, R. S. Freedberg, E. S. Katz, R. M. Applebaum, J. L. Perez, and I. Kronzon
Aortic Valve Replacement in Patients With Aortic Stenosis and Severe Left Ventricular Dysfunction
Arch Intern Med, May 8, 2000; 160(9): 1337 - 1341.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. S. Khan, R. J. Siegel, M. A. DeRobertis, C. E. Blanche, R. M. Kass, W. Cheng, G. P. Fontana, and A. Trento
Regression of hypertrophy after Carpentier-Edwards pericardial aortic valve replacement
Ann. Thorac. Surg., February 1, 2000; 69(2): 531 - 535.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Bernal, R. Martin-Duran, J. M. Rabasa, and J. M. Revuelta
The CarboMedics "Top-Hat" supraannular prosthesis
Ann. Thorac. Surg., May 1, 1999; 67(5): 1299 - 1303.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
S. P. Patsilinakos, I. P. Antonelis, G. Filippatos, I. K. Houssianakou, N. I. Zamanis, E. Sioras, T. Tsiotika, F. Kardaras, L. P. Anthopoulos, and A. Kranidis
Detection of Coronary Artery Disease in Patients with Severe Aortic Stenosis with Noninvasive Methods
Angiology, April 1, 1999; 50(4): 309 - 317.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
M. Arsenault, N. Masani, G. Magni, J. Yao, L. Deras, and N. Pandian
Variation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry: comparison with traditional Doppler data
J. Am. Coll. Cardiol., December 1, 1998; 32(7): 1931 - 1937.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. M. Otto, I. G. Burwash, M. E. Legget, B. I. Munt, M. Fujioka, N. L. Healy, C. D. Kraft, C. Y. Miyake-Hull, and R. G. Schwaegler
Prospective Study of Asymptomatic Valvular Aortic Stenosis : Clinical, Echocardiographic, and Exercise Predictors of Outcome
Circulation, May 6, 1997; 95(9): 2262 - 2270.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
T.-M. Lee, S.-F. Su, M.-F. Chen, C.-S. Liau, and Y.-T. Lee
Percutaneous Transvenous Mitral Balloon Valvuloplasty Alone in Patients with Combined Aortic and Mitral Stenosis
Angiology, May 1, 1997; 48(5): 445 - 450.
[Abstract] [PDF]


Home page
CirculationHome page
E. G. Cape, M. Jones, I. Yamada, M. D. VanAuker, and L. M. Valdes-Cruz
Turbulent/Viscous Interactions Control Doppler/Catheter Pressure Discrepancies in Aortic Stenosis: The Role of the Reynolds Number
Circulation, December 1, 1996; 94(11): 2975 - 2981.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. B. Izzat, I. Birdi, P. Wilde, A. J. Bryan, and G. D. Angelini
COMPARISON OF HEMODYNAMIC PERFORMANCES OF ST. JUDE MEDICAL AND CARBOMEDICS 21 MM AORTIC PROSTHESES BY MEANS OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY
J. Thorac. Cardiovasc. Surg., February 1, 1996; 111(2): 408 - 415.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. B. Izzat, I. Birdi, P. Wilde, A. J. Bryan, and G. D. Angelini
Evaluation of the hemodynamic performance of small carbomedics aortic prosthesis using dobutamine-stress doppler echocardiography
Ann. Thorac. Surg., October 1, 1995; 60(4): 1048 - 1052.
[Abstract] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
A. D. Waggoner, B. Barzilai, and J. E. Perez
Two-Dimensional Doppler Echocardiographic Derived Aortic Valve Area in Aortic Stenosis
Journal of Diagnostic Medical Sonography, March 1, 1991; 7(2): 64 - 72.
[Abstract] [PDF]


Home page
Arch Intern MedHome page
C. M. Otto and A. S. Pearlman
Doppler Echocardiography in Adults With Symptomatic Aortic Stenosis: Diagnostic Utility and Cost-effectiveness
Arch Intern Med, December 1, 1988; 148(12): 2553 - 2560.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement